BrandMicromeritics
OriginUSA
ModelAutoChem III
Instrument TypeChemisorption Analyzer
Measurement PrincipleGas-solid surface reaction kinetics and thermal desorption analysis
Number of Gas Inlets18
Temperature RangeAmbient to 1200 °C
Heating RateUp to 100 °C/min from –100 °C to 800 °C
Core FunctionsPulse chemisorption, Temperature-Programmed Reduction (TPR), Single-point BET surface area estimation
Cooling SystemIntegrated air-cooled AutoCool™ (no liquid nitrogen or external chiller required)
Sample Tube InterfacePatented KwikConnect™ one-piece sealed sample tube assembly (US Pat. No. 11,105,825 B2)
Water Removal TechnologyAutoTrap™ integrated condensate management for TPR (US Pat. No. 10,487,954 B)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelChemiSorb Auto
Instrument TypeChemisorption Analyzer
Measurement PrincipleFlow Method
Gas Inlet Ports8
Maximum Heating Temperature1000 °C
Heating Rate1–50 °C/min
Analytical CapabilitiesTPR, TPO, TPD, Pulse Chemisorption
Optional CryoCooler Range−100 °C to 1000 °C
Carrier Gas Ports4
Loop Gas Ports4
DetectorThermal Conductivity Detector (TCD), optional Mass Spectrometer (MS) integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Model3Flex Series
Instrument TypePhysical & Chemical Sorption Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Gas Inlet Ports16
High-Temperature Furnace RangeUp to 1100 °C
Pressure RangeP/P₀ down to 10⁻⁹
Core Functional CapabilitiesHigh-Precision TPR, TPO, and TPD Analysis
Sensor Resolution29-bit A/D Conversion
Manifold ArchitectureIndependently temperature-controlled (45 °C)歧管, P₀ tube, and analysis stations
Vacuum ControlServo-Valve-Actuated Automated Gas Dosing & Evacuation
Sealing Standard316 Stainless Steel VCR Fittings
Optional ModulesSteam Sorption (H₂O & Organic Vapors), Kr Adsorption for Low-Surface-Area Materials, TCD-Based Chemisorption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2020 Plus Series
Gas Inlet Ports12
Heating Temperature RangeAmbient to 1100 °C
Pressure Range0–1000 mmHg
Analytical FunctionsTPD, TPR
Optional ConfigurationsSteam Adsorption, Micropore Analysis (0.1 mmHg sensor + high-vacuum pump), Corrosion-Resistant Stainless Steel Manifold, Cryogenic Cooling Access
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelBTA
Instrument TypePhysical/Chemical Adsorption Analyzer
Measurement PrincipleDynamic Breakthrough Adsorption
Gas Inlet Ports6
Maximum Heating Temperature1,050 °C
Isothermal Stability RangeUp to 200 °C
Pressure RangeUp to 30 bar
Key FunctionalityCompetitive Adsorption, Multi-component Transient Adsorption Profiling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelChemiSorb HTP
PrincipleStatic Volumetric Method
Gas Inlet Ports12
Analysis Stations6
Temperature RangeAmbient +10 °C to 700 °C
Sample ReactorQuartz with Overflow Channel Design
Automation LevelFully Automated
Software InterfaceWindows-Based Control & Reporting Platform