BrandMicromeritics
OriginUSA
ManufacturerMicromeritics Instrument Corporation
ModelASAP 2050
Measurement PrincipleVolumetric (Manometric) High-Pressure Adsorption
Temperature Range20–120 °C (operational analysis range)
Pressure Range10⁻⁶ Torr to 10 atm (1.013 MPa)
Ultimate Vacuum<1×10⁻⁶ Torr
Sample Tube MaterialStainless Steel (straight-walled, rated to 150 psi)
Degassing ControlIndependent dual-station programmable heating (temperature ramp rate & hold time user-defined)
Optional CoolingLiquid nitrogen or argon cryogenic Dewar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2460 Series
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Gas Adsorption (Volumetric Method)
Number of Analysis Stations2–6 (Modular Expansion)
Pore Size Range0.35–500 nm
Pressure Range0–1000 mmHg (absolute)
Analytical TheoryGas Adsorption Isotherm Analysis (N₂, Ar, CO₂, H₂, Kr)
Optional ConfigurationsLow-Surface-Area (Kr), Micropore-Optimized (1 mmHg Transducer)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelAutoChem III
Instrument TypeChemisorption Analyzer
Measurement PrincipleGas-solid surface reaction kinetics and thermal desorption analysis
Number of Gas Inlets18
Temperature RangeAmbient to 1200 °C
Heating RateUp to 100 °C/min from –100 °C to 800 °C
Core FunctionsPulse chemisorption, Temperature-Programmed Reduction (TPR), Single-point BET surface area estimation
Cooling SystemIntegrated air-cooled AutoCool™ (no liquid nitrogen or external chiller required)
Sample Tube InterfacePatented KwikConnect™ one-piece sealed sample tube assembly (US Pat. No. 11,105,825 B2)
Water Removal TechnologyAutoTrap™ integrated condensate management for TPR (US Pat. No. 10,487,954 B)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2020 Plus HD88 Series
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Method
Analysis Stations1 adsorption station
Degassing Stations2 independent stations
Pressure Range0–1000 mmHg
Applicable Pore TypesMicropores, Mesopores, Low Surface Area Materials
TheoryBET, Langmuir, BJH, DFT, NLDFT, t-plot, αs-method
Repeatability<1% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelChemiSorb Auto
Instrument TypeChemisorption Analyzer
Measurement PrincipleFlow Method
Gas Inlet Ports8
Maximum Heating Temperature1000 °C
Heating Rate1–50 °C/min
Analytical CapabilitiesTPR, TPO, TPD, Pulse Chemisorption
Optional CryoCooler Range−100 °C to 1000 °C
Carrier Gas Ports4
Loop Gas Ports4
DetectorThermal Conductivity Detector (TCD), optional Mass Spectrometer (MS) integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelTriStar II Plus 3030
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations3
Specific Surface Area Range0.001 m²/g to unlimited
Pressure Range0–1000 mmHg
Theoretical BasisGas Adsorption Analysis
ConstructionCorrosion-Resistant Stainless Steel Manifold
Cryogenic Duration>40 hours with optimized Dewar design
Software PlatformMicroActive v4.x with Python scripting support
Compliance ReadyASTM D3663, ISO 9277, ISO 15901-2, USP <846>, IUPAC 2015 recommendations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Model3Flex
Analysis Stations3
Measurement PrincipleStatic Volumetric Method
Analyte GasesN₂, Ar, Kr, CO₂, H₂, CH₄, and optional vapors (e.g., H₂O, ethanol)
Minimum Relative Pressure (P/P₀)1×10⁻⁹
Pressure ResolutionDown to 10⁻⁶ mmHg
Sample CompatibilityMicroporous, mesoporous, and macroporous solids including MOFs, zeolites, activated carbons, catalysts, and metal oxides
SoftwareMicroActive™ v4.x with NLDFT/QSDFT kernel, Python API support, 21 CFR Part 11-compliant audit trail option
ComplianceASTM D3663, ISO 9277, ISO 15901-2, USP <846>, GLP/GMP-ready configuration available
Data ExportCSV, PDF, XML, HDF5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelGemini VII 2390 Series
Analysis PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations1
Specific Surface Area Range≥0.01 m²/g (no upper limit)
Pressure Range0–1000 mmHg
Adsorptive GasN₂ (optimized for liquid nitrogen bath), He, Ar, O₂, CO₂, CH₄, C₄H₁₀
Relative Pressure (P/P₀) Range0–1.0 (adsorption only)
P/P₀ Resolution<10⁻⁴
Pressure Resolution<0.1 mmHg
Sensor Accuracy & Linearity±0.5% of full scale
Operating Temperature10–35 °C
Relative Humidity20–80% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Model3Flex Series
Instrument TypePhysical & Chemical Sorption Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Gas Inlet Ports16
High-Temperature Furnace RangeUp to 1100 °C
Pressure RangeP/P₀ down to 10⁻⁹
Core Functional CapabilitiesHigh-Precision TPR, TPO, and TPD Analysis
Sensor Resolution29-bit A/D Conversion
Manifold ArchitectureIndependently temperature-controlled (45 °C)歧管, P₀ tube, and analysis stations
Vacuum ControlServo-Valve-Actuated Automated Gas Dosing & Evacuation
Sealing Standard316 Stainless Steel VCR Fittings
Optional ModulesSteam Sorption (H₂O & Organic Vapors), Kr Adsorption for Low-Surface-Area Materials, TCD-Based Chemisorption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2425
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Gas Adsorption (Volumetric Method)
Number of Analysis Stations6
Pore Size Range0.35–500 nm
Pressure Range0–950 mmHg
Adsorption TheoryBrunauer-Emmett-Teller (BET), t-plot, Langmuir, DFT, NLDFT
Sample Preparation Stations12 independent, temperature-controlled (ambient to 450 °C)
Optional ConfigurationsLow-surface-area mode (Kr adsorption, 10 mmHg transducer), Micropore-enhanced mode (1 mmHg transducer)
SoftwareMicroActive v5.x with ASTM/ISO-compliant reporting, FDA 21 CFR Part 11 audit trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2020 Plus Series
Gas Inlet Ports12
Heating Temperature RangeAmbient to 1100 °C
Pressure Range0–1000 mmHg
Analytical FunctionsTPD, TPR
Optional ConfigurationsSteam Adsorption, Micropore Analysis (0.1 mmHg sensor + high-vacuum pump), Corrosion-Resistant Stainless Steel Manifold, Cryogenic Cooling Access
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2460
ConfigurationDual-Station Base Module (Expandable to 4- or 6-Station)
Gas DosingServo-Valve Controlled Quantitative Gas Injection & Evacuation
Gas Inlets5 Total (Including Dedicated Free-Space Measurement Inlet)
Analysis Duration Without RefillUp to 60 h
BET Surface Area Throughput6 Samples in ≤30 min (with Two Expansion Modules)
Software PlatformMicroActive v4.x
Theoretical Models SupportedBET, Langmuir, t-Plot, DFT, NLDFT
Optional ConfigurationsLow-Surface-Area (Kr) Mode (10 mmHg Transducer), Micropore Mode (1 mmHg Transducer, Enhanced Low-Pressure Resolution, Compatible with N₂, Ar, CO₂, H₂)
Compliance FrameworkDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelAccuPore
Measurement PrincipleCapillary Flow Porometry (CFP)
Standard ComplianceASTM F316
Pore Size Range0.013–500 µm (fluid-dependent)
Maximum Pressure500 psi (35 bar)
Gas Flow Rate RangeUp to 200 L/min
Sample Diameters Supported13 mm, 25 mm, 47 mm
Data Resolution>1000 data points per run
Sampling Rate20 Hz
Operating GasesAir or Nitrogen
Measurement ModesBubble Point, Wet/Dry, Wet/Calculated-Dry, Wet/Dry Flow Curve Analysis
Sample Prep Time<30 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2020 PLUS
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption
Analysis Stations1
Pore Size Range0.35–500 nm
Relative Pressure RangeP/P₀ ≥ 10⁻⁸
Theoretical BasisGas Adsorption Isotherm Analysis (BET, BJH, DFT, NLDFT, t-plot, αₛ-plot)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelHPVA-II
Measurement PrincipleStatic Volumetric Method (High-Pressure Capacity Technique)
Temperature Range30 K to 500 °C
Pressure RangeUltra-High Vacuum (≤1×10⁻⁹ Torr) to 200 bar
Vacuum Level<1×10⁻⁹ Torr
Compatible GasesH₂, CH₄, CO₂, N₂, Ar, and other non-corrosive gases
Sample RequirementAs low as 5–50 mg
Sample TypesMOFs, Zeolites, Activated Carbons, Porous Polymers, Metal Hydrides, Catalyst Supports
Thermal Control OptionsLiquid Cryogen Dewar (4 L stainless steel), External Circulating Bath, Resistive Heating Furnace, Closed-Cycle Cryocooler Integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelGemini VII 2390 Series
Analysis PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations1
Specific Surface Area Range0.01 m²/g to unlimited
Pressure Range0–1000 mmHg
Measurement TheoryGas Adsorption (BET, Langmuir, t-Plot, HK, BJH)
Software OptionsKeypad Embedded Firmware, Gemini Windows Software, FDA 21 CFR Part 11-Compliant Confirm Software
Dual-Mode OperationStandalone Keypad or PC-Controlled
ComplianceASTM D3663, ISO 9277, USP <846>, GLP/GMP-ready audit trail (Confirm version)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelBTA
Instrument TypePhysical/Chemical Adsorption Analyzer
Measurement PrincipleDynamic Breakthrough Adsorption
Gas Inlet Ports6
Maximum Heating Temperature1,050 °C
Isothermal Stability RangeUp to 200 °C
Pressure RangeUp to 30 bar
Key FunctionalityCompetitive Adsorption, Multi-component Transient Adsorption Profiling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelTriStar II Plus
Analysis Stations3 (independent)
Measurable Surface Area≥0.01 m²/g (N₂), ≥0.001 m²/g (Kr)
Pore Volume Detection Limit≥4 × 10⁻⁶ cm³/g
Dewar Capacity2.75 L (optional 4 L)
Continuous Operation Timeup to 40 h
Gas CompatibilityN₂, Ar, CO₂, C₄H₁₀, CH₄, and other non-corrosive gases
P₀ Measurementcontinuous, manual, or in-situ
Data Points per Isothermup to 1000
SoftwareWindows-based with SPC reporting, DFT modeling, t-plot, αₛ-plot, isosteric heat calculation, and thickness model integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelChemiSorb HTP
PrincipleStatic Volumetric Method
Gas Inlet Ports12
Analysis Stations6
Temperature RangeAmbient +10 °C to 700 °C
Sample ReactorQuartz with Overflow Channel Design
Automation LevelFully Automated
Software InterfaceWindows-Based Control & Reporting Platform
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelTriStar II Plus Series
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations3
Surface Area Range0.001 m²/g to unlimited
Pressure Range0–1000 mmHg
Theoretical BasisGas Adsorption Method
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelAutoPore V Series
Pore Size Range3 nm – 1100 µm
Pressure Range0.2 – 50 psia
Intrusion/Extrusion Volume Precision< 0.1 µL
ComplianceASTM D4284, D4404, D6761