Empowering Scientific Discovery

Micromeritics Instrument (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelGeoPyc 1365
Instrument TypeBenchtop Envelope Density Analyzer
Sample FormSolids (powders, granules, irregular solids, tablets, foams)
Measurement PrincipleSolid displacement using Dry Flo™ quasi-fluid medium
Envelope Volume Range0.3–25 cm³ (via interchangeable sample cups)
Density Accuracy<0.15% deviation vs. ASTM D1895, D6342, D7481
Operating Temperature15–35 °C
Minimum Sample Requirement≥25% of selected cup volume
ComplianceASTM D1895 (Type A), D6342, D7481, ISO 697, USP <699>, FDA 21 CFR Part 11 (with optional audit trail module)
Optional T.A.P. Density ModuleProgrammable consolidation force (0.5–10 N), stepwise compression cycles, real-time force & displacement monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUnited Kingdom
ModelFT4
Instrument TypeMultifunctional Powder Flowability Tester
Measurable Powder ParametersFlow Function, Flow Energy, Aeration Energy, Consolidation Energy, Compressibility, Permeability, Wall Friction Angle
Maximum Sample Vessel Capacity160 mL
Minimum Sample Volume1 mL (with optional mini shear cell) / 10 mL (standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
ModelBlue Label and Red Label variants
Particle Size Range0.3 nm – 15 µm
Size Reproducibility±2%
Temperature Control Range10–35 °C
Temperature Stability±0.1 °C
Zeta Potential RangeNo effective limit
Measurement Time3–5 min
Molecular Weight Range980 Da – 20 MDa
Concentration Range0.1 mg/mL – 40% w/v
Minimum Sample Volume3 µL
Particle Sizing MethodNon-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®)
Zeta Potential MethodM3-PALS (Phase Analysis Light Scattering) with Constant Current Mode
Software ComplianceFDA 21 CFR Part 11, GLP/GMP-ready audit trail
Optional AccessoriesMPT-3 Auto-Titrator, Polarization/Fluorescence Filter Wheel, Disposable Capillary Cells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ManufacturerMicromeritics Instrument Corporation
ModelASAP 2050
Measurement PrincipleVolumetric (Manometric) High-Pressure Adsorption
Temperature Range20–120 °C (operational analysis range)
Pressure Range10⁻⁶ Torr to 10 atm (1.013 MPa)
Ultimate Vacuum<1×10⁻⁶ Torr
Sample Tube MaterialStainless Steel (straight-walled, rated to 150 psi)
Degassing ControlIndependent dual-station programmable heating (temperature ramp rate & hold time user-defined)
Optional CoolingLiquid nitrogen or argon cryogenic Dewar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Model3Flex
Gas Adsorption CapabilityPhysisorption & Chemisorption (optional)
Tri-Station OperationIndependent simultaneous analysis
Pressure RangeDown to 1×10⁻⁹ P/P₀
Detection LimitUltra-micropore resolution (≤ 0.7 nm)
Vapor CompatibilityIntegrated thermostatted manifold (45 °C ±0.05 °C), optional heated vapor dosing
SoftwareMicroActive™ with customizable reporting, ASTM/ISO-compliant data processing
Sample PreparationIn-situ tube heater for degassing under vacuum or inert gas
Sealing SystemMetal-sealed, hard-stop valves with corrosion-resistant manifold
P₀ MeasurementDedicated P₀ sensor with continuous saturation pressure monitoring
Fluid Library>80 pre-loaded adsorbates (N₂, Ar, CO₂, H₂, Kr, H₂O, alcohols, hydrocarbons, etc.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2460 Series
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Gas Adsorption (Volumetric Method)
Number of Analysis Stations2–6 (Modular Expansion)
Pore Size Range0.35–500 nm
Pressure Range0–1000 mmHg (absolute)
Analytical TheoryGas Adsorption Isotherm Analysis (N₂, Ar, CO₂, H₂, Kr)
Optional ConfigurationsLow-Surface-Area (Kr), Micropore-Optimized (1 mmHg Transducer)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelAccuPyc III 1350
Instrument TypeTrue Density Analyzer
ConfigurationBenchtop Laboratory System
Sample FormSolid Powders, Granules, Monoliths
Measurement PrincipleGas Displacement (Helium/Nitrogen/Air)
Density Range0.1–100 cm³ (Sample Volume Capacity)
Accuracy±0.02%
Repeatability±0.01%
Temperature Control Range4 °C to 60 °C
Temperature Stability±0.025 °C
Minimum Sample Volume0.1 cm³
ComplianceASTM D5550, ISO 12154, USP <699>, GLP/GMP-ready audit trail support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelAutoChem III
Instrument TypeChemisorption Analyzer
Measurement PrincipleGas-solid surface reaction kinetics and thermal desorption analysis
Number of Gas Inlets18
Temperature RangeAmbient to 1200 °C
Heating RateUp to 100 °C/min from –100 °C to 800 °C
Core FunctionsPulse chemisorption, Temperature-Programmed Reduction (TPR), Single-point BET surface area estimation
Cooling SystemIntegrated air-cooled AutoCool™ (no liquid nitrogen or external chiller required)
Sample Tube InterfacePatented KwikConnect™ one-piece sealed sample tube assembly (US Pat. No. 11,105,825 B2)
Water Removal TechnologyAutoTrap™ integrated condensate management for TPR (US Pat. No. 10,487,954 B)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2020 Plus HD88 Series
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Method
Analysis Stations1 adsorption station
Degassing Stations2 independent stations
Pressure Range0–1000 mmHg
Applicable Pore TypesMicropores, Mesopores, Low Surface Area Materials
TheoryBET, Langmuir, BJH, DFT, NLDFT, t-plot, αs-method
Repeatability<1% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelChemiSorb Auto
Instrument TypeChemisorption Analyzer
Measurement PrincipleFlow Method
Gas Inlet Ports8
Maximum Heating Temperature1000 °C
Heating Rate1–50 °C/min
Analytical CapabilitiesTPR, TPO, TPD, Pulse Chemisorption
Optional CryoCooler Range−100 °C to 1000 °C
Carrier Gas Ports4
Loop Gas Ports4
DetectorThermal Conductivity Detector (TCD), optional Mass Spectrometer (MS) integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelICCS
QuotationUpon Request
Operating PressureUp to 20 bar(g)
Valve Box Temperature RangeUp to 180 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelSAS II 5800
Measurement Range0.2–75 µm
Repeatability±1% RSD
Porosity Range0.2–0.9
ComplianceASTM B330-12, ASTM C721-14
DisplayIntegrated Touchscreen Interface
Control SoftwareSAS Control Suite v5.x
Dimensions (H×W×L)55 × 50 × 38 cm
Weight28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelTriStar II Plus 3030
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations3
Specific Surface Area Range0.001 m²/g to unlimited
Pressure Range0–1000 mmHg
Theoretical BasisGas Adsorption Analysis
ConstructionCorrosion-Resistant Stainless Steel Manifold
Cryogenic Duration>40 hours with optimized Dewar design
Software PlatformMicroActive v4.x with Python scripting support
Compliance ReadyASTM D3663, ISO 9277, ISO 15901-2, USP <846>, IUPAC 2015 recommendations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Model3Flex
Analysis Stations3
Measurement PrincipleStatic Volumetric Method
Analyte GasesN₂, Ar, Kr, CO₂, H₂, CH₄, and optional vapors (e.g., H₂O, ethanol)
Minimum Relative Pressure (P/P₀)1×10⁻⁹
Pressure ResolutionDown to 10⁻⁶ mmHg
Sample CompatibilityMicroporous, mesoporous, and macroporous solids including MOFs, zeolites, activated carbons, catalysts, and metal oxides
SoftwareMicroActive™ v4.x with NLDFT/QSDFT kernel, Python API support, 21 CFR Part 11-compliant audit trail option
ComplianceASTM D3663, ISO 9277, ISO 15901-2, USP <846>, GLP/GMP-ready configuration available
Data ExportCSV, PDF, XML, HDF5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelGemini VII 2390 Series
Analysis PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations1
Specific Surface Area Range≥0.01 m²/g (no upper limit)
Pressure Range0–1000 mmHg
Adsorptive GasN₂ (optimized for liquid nitrogen bath), He, Ar, O₂, CO₂, CH₄, C₄H₁₀
Relative Pressure (P/P₀) Range0–1.0 (adsorption only)
P/P₀ Resolution<10⁻⁴
Pressure Resolution<0.1 mmHg
Sensor Accuracy & Linearity±0.5% of full scale
Operating Temperature10–35 °C
Relative Humidity20–80% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
Model3Flex Series
Instrument TypePhysical & Chemical Sorption Analyzer
Measurement PrincipleStatic Volumetric Method
Number of Gas Inlet Ports16
High-Temperature Furnace RangeUp to 1100 °C
Pressure RangeP/P₀ down to 10⁻⁹
Core Functional CapabilitiesHigh-Precision TPR, TPO, and TPD Analysis
Sensor Resolution29-bit A/D Conversion
Manifold ArchitectureIndependently temperature-controlled (45 °C)歧管, P₀ tube, and analysis stations
Vacuum ControlServo-Valve-Actuated Automated Gas Dosing & Evacuation
Sealing Standard316 Stainless Steel VCR Fittings
Optional ModulesSteam Sorption (H₂O & Organic Vapors), Kr Adsorption for Low-Surface-Area Materials, TCD-Based Chemisorption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginNetherlands
ModelEmpyrean
Instrument TypePowder X-ray Diffractometer
ConfigurationFloor-standing
Power Consumption0.0001 kW
Core TechnologyMultiCore Optics (iCore/dCore)
Detector TechnologyHybrid Pixel Array (PIXcel3D / GaliPIX3D)
Sample FlexibilityPowder, Thin Film, Nanomaterials, Bulk Solids
Compliance FrameworkGLP-ready, PreFIX modular architecture, ISO/IEC 17025-compatible workflow support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2425
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Gas Adsorption (Volumetric Method)
Number of Analysis Stations6
Pore Size Range0.35–500 nm
Pressure Range0–950 mmHg
Adsorption TheoryBrunauer-Emmett-Teller (BET), t-plot, Langmuir, DFT, NLDFT
Sample Preparation Stations12 independent, temperature-controlled (ambient to 450 °C)
Optional ConfigurationsLow-surface-area mode (Kr adsorption, 10 mmHg transducer), Micropore-enhanced mode (1 mmHg transducer)
SoftwareMicroActive v5.x with ASTM/ISO-compliant reporting, FDA 21 CFR Part 11 audit trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2020 Plus Series
Gas Inlet Ports12
Heating Temperature RangeAmbient to 1100 °C
Pressure Range0–1000 mmHg
Analytical FunctionsTPD, TPR
Optional ConfigurationsSteam Adsorption, Micropore Analysis (0.1 mmHg sensor + high-vacuum pump), Corrosion-Resistant Stainless Steel Manifold, Cryogenic Cooling Access
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginSpain
ModelFR-50, FR-100, FR-200
Construction MaterialStainless Steel (316 SS)
Operating Pressure RangeAmbient to 100 bar or 200 bar (model-dependent)
Temperature RangeAmbient to 1000 °C
Number of Gas InletsUp to 6
Mass Flow ControllersUp to 6 integrated MFCs
Phase SeparationIntegrated low-dead-volume gas–liquid or gas–liquid–liquid separator (US Pat. 7895891 B2
Pressure Control Accuracy±0.1 bar (US Pat. 8740181 B2)
Safety SystemRedundant pressure/temperature monitoring, automated shutdown, audible/visual alarms, fail-safe valve actuation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2460
ConfigurationDual-Station Base Module (Expandable to 4- or 6-Station)
Gas DosingServo-Valve Controlled Quantitative Gas Injection & Evacuation
Gas Inlets5 Total (Including Dedicated Free-Space Measurement Inlet)
Analysis Duration Without RefillUp to 60 h
BET Surface Area Throughput6 Samples in ≤30 min (with Two Expansion Modules)
Software PlatformMicroActive v4.x
Theoretical Models SupportedBET, Langmuir, t-Plot, DFT, NLDFT
Optional ConfigurationsLow-Surface-Area (Kr) Mode (10 mmHg Transducer), Micropore Mode (1 mmHg Transducer, Enhanced Low-Pressure Resolution, Compatible with N₂, Ar, CO₂, H₂)
Compliance FrameworkDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelAccuPore
Measurement PrincipleCapillary Flow Porometry (CFP)
Standard ComplianceASTM F316
Pore Size Range0.013–500 µm (fluid-dependent)
Maximum Pressure500 psi (35 bar)
Gas Flow Rate RangeUp to 200 L/min
Sample Diameters Supported13 mm, 25 mm, 47 mm
Data Resolution>1000 data points per run
Sampling Rate20 Hz
Operating GasesAir or Nitrogen
Measurement ModesBubble Point, Wet/Dry, Wet/Calculated-Dry, Wet/Dry Flow Curve Analysis
Sample Prep Time<30 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelASAP 2020 PLUS
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption
Analysis Stations1
Pore Size Range0.35–500 nm
Relative Pressure RangeP/P₀ ≥ 10⁻⁸
Theoretical BasisGas Adsorption Isotherm Analysis (BET, BJH, DFT, NLDFT, t-plot, αₛ-plot)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
ModelMastersizer 3000+
Dispersion MethodDry & Wet
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.01–3500 µm
Repeatability<1% RSD
Measurement Time<10 s
Show next