- All
- Favorite
- Popular
- Most rated
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PCH-1 / PCH-2 |
| Temperature Range | −10 °C to 100 °C |
| Stability | ±0.2 °C |
| Uniformity | ±0.5 °C |
| Heating Rate | >10 °C/min |
| Cooling Rate | >2 °C/min |
| Capacity | PCH-1 — 12 × 1.5 mL + 20 × 0.5 mL tubes |
| Dimensions (W×D×H) | 225 × 195 × 161 mm |
| Input Voltage | 220 V AC |
| Input Current | 0.5 A |
| Brand | Grant Instruments (UK) |
|---|---|
| Origin | United Kingdom |
| Model | TC120 Series |
| Temperature Range | −20 °C to +100 °C |
| Stability | ±0.05 °C (DIN 12876 @ 70 °C) |
| Uniformity | ±0.1 °C (DIN 12876 @ 70 °C) |
| Setpoint Resolution | 0.1 °C |
| Built-in Circulation Pump | Max. 16 L/min, 210 mbar |
| Heating Power | 1.3 kW (230 V), 1.4 kW (120 V) |
| Safety Features | Adjustable overtemperature cut-off, low-level float switch, audible/visual alarm |
| Programming | 4 preset temperatures (1 active + 3 stored) |
| Display | 4-digit LED |
| Calibration | Two-point user calibration |
| Optional Accessories | ST-series stainless steel baths (5–38 L), P-series polypropylene baths (5–18 L), removable insulated lid, external probe interfaces (TXPEP/TXSEP) |
| Brand | Techne |
|---|---|
| Origin | United Kingdom |
| Model | RB-5A |
| Temperature Range | −20 °C to 100 °C |
| Minimum Achievable Temperature (at 20 °C ambient) | −20 °C |
| Cooling Power at 20 °C | 145 W |
| Cooling Power at 0 °C | 145 W |
| Cooling Power at −10 °C | 110 W |
| External Dimensions (L×W×H) | 430×250×566 mm |
| Internal Dimensions (L×W×H) | 192×151×200 mm |
| Max Liquid Level to Top | 65 mm |
| Working Height Range | 180/135 mm |
| Max/Min Working Volume | 7.0/5.5 L |
| Flow Rate (Pressure) | 20 L/min |
| Flow Rate (Suction) | 15 L/min |
| Shipping Weight | 31 kg |
| Controller Included | Yes |
| Fluid Compatibility | Water/glycol/alcohol mixtures (e.g., 40/40/20 v/v/v for −35 °C operation) |
| Brand | Grant Instruments (Cambridge, UK) |
|---|---|
| Origin | United Kingdom |
| Model | TX150 Series |
| Temperature Range | –50 °C to +150 °C |
| Stability (DIN 12876 @ 70 °C) | ±0.01 °C |
| Uniformity (DIN 12876 @ 70 °C) | ±0.05 °C |
| Heating Power | 1.9 kW (230 V) |
| Max. Flow Rate | 17 L/min |
| Max. Pressure | 270 mbar |
| Language Options | English, French, German, Spanish, Italian |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | BT5D |
| Temperature Range | Ambient +10 to 400 °C |
| Display | LED |
| Temperature Resolution | 1 °C |
| Stability | ±0.5 °C up to 300 °C |
| Uniformity | ±2 °C at 200 °C, ±3 °C at 300 °C, ±4 °C at 400 °C |
| Heating Rate Control | 0.1 °C/min adjustable |
| Timer Range | 1–999 minutes |
| Power | 750 W |
| Voltage | 230 V AC |
| Dimensions (W×D×H) | 410 × 205 × 150 mm |
| Block Material | Anodized Aluminum |
| Safety | Adjustable Over-Temperature Protection |
| Compliance | CE, UKCA, RoHS |
| Brand | Grant |
|---|---|
| Origin | UK |
| Model | JB Aqua Plus |
| Temperature Range | Ambient +5°C to 98°C |
| Stability | ±1.0°C |
| Setpoint Resolution | 0.1°C |
| Control Type | Analog Dial |
| Heating Power | 0.13–2.1 kW (model-dependent) |
| Chamber Volume | 2–34 L (single) or 5+12 L (dual) |
| Construction | Stainless Steel Interior & Exterior |
| Safety Features | Adjustable Over-Temperature Cut-Off, Dry-Run Protection |
| Standard Accessories | Polycarbonate Dome Lid, Insulated Base |
| Drain Valve | Optional on JB Aqua 12 Plus, 18 Plus, 26 Plus, 34 Plus, and Dual Plus models |
| Compliance | CE-marked, designed per IEC 61010-1 for laboratory use |
| Brand | Grant |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTD |
| Price | Upon Request |
| Temperature Range | Ambient +5°C to 100°C |
| Setpoint Range | 25°C to 100°C |
| Stability @37°C | ±0.1°C |
| Uniformity @37°C | ±0.2°C |
| Heating Time (25°C → 100°C) | 16 min |
| External Dimensions (W×D×H) | 210 × 230 × 110 mm |
| Block Diameter/Depth | 130 × 45 mm |
| Power Rating | 200 W |
| Timer Range | 1 min – 96 h |
| Over-Temperature Protection | Thermal Cut-Out Fuse |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TX150 R |
| Temperature Range | −47 °C to +100 °C |
| Stability | ±0.1 °C (DIN 12876, water @ 10 °C) |
| Max Flow Rate | 18 L/min (adjustable) |
| Max Pressure | 310 mbar |
| Display | QVGA TFT color touchscreen |
| Programmability | 30-step program, USB & RS232 interface |
| Compliance | DIN 12876, CE, RoHS, Class B EMC |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | SAP12 |
| Bath Volume | 12 L |
| Temperature Range | Ambient +5 °C to 99 °C |
| Temperature Stability | ±0.2 °C @ 37 °C (per DIN 12876) |
| Control Type | Digital, Heating-Only |
| Circulation | Non-Circulating |
| Voltage Options | 120 V or 230 V AC |
| Power Rating | 0.77 kW (230 V) / 0.77 kW (120 V) |
| Over-Temperature Protection | Adjustable Cut-Off |
| Safety Certification | CSA Approved |
| Display | 3-digit LED |
| Preset Programs | 3 |
| Drain Valve | Yes |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | SBH130D, SBH200D, SBH130D/3, SBH200D/3 |
| Quotation | Available Upon Request |
| Control Method | Digital PID Temperature Control |
| Temperature Range | Ambient +8°C to 130°C (SBH130D/SBH130D/3) or Ambient +8°C to 200°C (SBH200D/SBH200D/3) |
| Temperature Stability at 37°C | ±0.1°C |
| Temperature Uniformity at 37°C | ±0.1°C |
| Temperature Uniformity at 130°C | ±1.0°C (SBH130D/SBH200D) or ±0.1°C (SBH130D/3/SBH200D/3) |
| Display | High-Brightness LED with 0.1°C Resolution |
| Weight | 2.3 kg (2-block models) or 3.2 kg (3-block models) |
| Dimensions (W×D×H) | 235 × 280 × 115 mm (2-block) or 310 × 280 × 115 mm (3-block) |
| Electrical Supply | 230 V AC, 50 Hz |
| Power Rating | 300 W (SBH130D, SBH200D, SBH130D/3) or 450 W (SBH200D/3) |
| Heating Blocks Supported | 2 or 3 interchangeable aluminum blocks (user-selectable well configurations) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | TXF200 R |
| Temperature Range | –47 °C to +100 °C (refrigerated mode) |
| Stability | ±0.1 °C (DIN 12876, water @ 10 °C) |
| Uniformity | ±0.1 °C (DIN 12876, water @ 10 °C) |
| Max Flow Rate | 23 L/min (adjustable) |
| Max Pressure | 530 mbar |
| Display | QVGA TFT color screen |
| Calibration | Dual-point user recalibration (TXPEP/TXSEP probes) |
| Interface | USB & RS232 |
| Programming Capacity | 10 programs, up to 100 stages each |
| Safety Features | Adjustable overtemperature cutoff, low-level float switch protection, audible/visual high/low temperature alarms |
| Fluid Compatibility | Water, 50% water/50% ethylene glycol, and other non-corrosive heat transfer fluids |
| Compliance | DIN 12876-1:2018 (laboratory thermostats), CE, UKCA, RoHS, EMC Class B |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | T100 Series |
| Temperature Range | 0 °C to 100 °C |
| Stability (DIN 12876 @ 70 °C) | ±0.05 °C |
| Uniformity (DIN 12876 @ 70 °C) | ±0.1 °C |
| Setpoint Resolution | 0.1 °C |
| Heating Power (230 V) | 1.3 kW |
| Built-in Circulation Pump | Yes (max. 16 L/min, 210 mbar) |
| Bath Compatibility | ST-series (stainless steel, 5–38 L) and P-series (polypropylene, 5–18 L) |
| Safety Features | Over-temperature cut-off, low-level float switch, audible/visual alarm |
| Interface | 4-digit LED display, rotary knob + two function keys |
| Programmability | 4 preset temperatures, simple manual setup |
| Optional Accessories | Labwise™ PC software, external probes (TXPEP/TXSEP), VTP high-pressure pumps, immersion chillers (C1G/C2G), heat-exchange coils (CW5), bath covers, sample racks (VR/QR series) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SBB AQUA 5/12/18/26 PLUS |
| Temperature Range | Ambient +5 °C to 100 °C |
| Power Supply | 220–240 V AC |
| Heating Power | 1.5 kW (SBB AQUA 5 & 12 PLUS), 2.0 kW (SBB AQUA 18 & 26 PLUS) |
| Capacity | 5 L / 12 L / 18 L / 26 L |
| Working Chamber Dimensions (L×W×D) | 270×215×385 mm / 270×390×385 mm / 270×570×385 mm / 300×570×385 mm |
| Safety Feature | Adjustable Over-Temperature Cut-Off Protection |
| Control Type | Analog Temperature Regulation |
| Standard Lid | Drip-Resistant Polycarbonate Cover |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | QBD1 |
| Temperature Range | Ambient +5°C to 130°C |
| Temperature Accuracy | ±0.1°C @ 37°C |
| Temperature Uniformity (within module) | ±0.1°C @ 37°C |
| Set Resolution | 0.1°C |
| Heating Time (25°C → 100°C) | 15 min |
| Power Consumption | 150 W |
| Input Voltage | 120 V or 230 V AC, 50/60 Hz |
| Safety Features | Over-temperature cut-off fuse, adjustable high/low temperature alarm (±0.5°C from setpoint), fault indicator display |
| Programmability | Up to 3 user-defined temperature/time segments, audible end-of-timer alert, timer extension up to 72 h |
| Calibration | Dual-point calibration support (internal and external probe) |
| Module Dimensions (H × D × W) | 100 mm × 230 mm × 200 mm |
| Brand | Grant Instruments (UK) |
|---|---|
| Origin | United Kingdom |
| Model | GLS Aqua 12 Plus / GLS Aqua 18 Plus |
| Temperature Range | Ambient +5°C to 99°C |
| Temperature Stability | ±0.1°C @ 37°C |
| Temperature Uniformity | ±0.1°C @ 37°C |
| Linear Oscillation Range | 40–400 rpm |
| Oscillation Amplitude | 18 mm |
| Bath Capacity | 12 L or 18 L (stainless steel, electropolished AISI 316) |
| Display | 3-digit LED, 0.1°C resolution |
| Power Supply | 120 V / 230 V, 50–60 Hz |
| Max. Power Consumption | 0.8 kW (GLS Aqua 12 Plus), 1.15–1.5 kW (GLS Aqua 18 Plus) |
| Safety Features | Overtemperature cut-off, low-level fluid alarm, user-configurable timer with audible alert |
| Dimensions (H×D×W) | 270 × 390 × 335 mm (12L), 270 × 570 × 335 mm (18L) |
| Immersion Depth | 0–60 mm |
| Tray Dimensions | 240 × 235 mm (12L), 420 × 235 mm (18L) |
| Brand | Grant Instruments (Cambridge) Ltd. |
|---|---|
| Origin | United Kingdom |
| Model | TXF200 Series |
| Temperature Range | −50 °C to +200 °C |
| Stability (DIN 12876, @70 °C) | ±0.01 °C |
| Uniformity (DIN 12876, @70 °C) | ±0.05 °C |
| Programmability | 10 programs × 100 steps |
| Internal Pump Flow Rate | up to 21 L/min (adjustable) |
| Max. Pump Pressure | 460 mbar |
| Heating Power | 2.0 kW (230 V), 1.5 kW (120 V) |
| Display | QVGA TFT color screen |
| Interface | USB & RS232 |
| Calibration | Dual-point user calibration for internal and external PT1000 probes |
| Safety | Adjustable overtemperature cutoff, low-level float switch protection, audible/visual alarms |
| Compliance | EN 61000-3-3 (harmonic emission), DIN 12876 (laboratory thermostats) |
| Brand | Grant Instruments (UK) |
|---|---|
| Origin | United Kingdom |
| Model Series | T100, TC120, TX150, TXF200 |
| Bath Volume | 38 L |
| Temperature Range | 0–200 °C |
| Temperature Stability | ±0.005 °C (at setpoint, typical for TX150/TXF200 under optimal conditions) |
| Circulation Mode | Internal & External (T100 supports internal only) |
| Control Type | Refrigerated/Heating |
| Heating Power (230 V) | 1.3–1.9 kW |
| Max Flow Rate (Water) | 16–23 L/min |
| Max Pressure (Water) | 210–530 mbar |
| Interface | USB & RS232 (TC120/TX150/TXF200) |
| Display | 4-digit LED / QVGA TFT color screen |
| Setpoint Resolution | 0.1 °C (0.01 °C with Labwise™ software) |
| Calibration | Two-point user calibration supported (TX150/TXF200) |
| Safety Features | Over-temperature cutoff (adjustable/fixed), low-level float switch, programmable high/low temperature alarms |
| Compliance | DIN 12876-1 (Class I/II), CE, UKCA |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | SAP5 |
| Bath Volume | 5 L |
| Temperature Range | Ambient +5 °C to 99 °C |
| Temperature Stability | ±0.2 °C @ 37 °C (per DIN 12876) |
| Control Type | Digital, Heating-Only |
| Circulation | Non-Circulating |
| Voltage Options | 120 V or 230 V AC |
| Power Rating | 0.375 kW (230 V), 0.13 kW (120 V) |
| Over-Temperature Protection | Adjustable Cut-Out |
| Safety Certification | CSA Approved |
| Display | 3-digit LED |
| Preset Programs | 3 |
| Drain Valve | Yes |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | SUB Aqua Plus |
| Temperature Range | 5°C above ambient to 99°C |
| Temperature Setting Range | 10–99°C in 0.1°C increments |
| Temperature Stability (DIN 12876-1 | 2013) @ 37°C: ±0.2°C |
| Control Method | Digital PID control with microprocessor-based thermostat |
| Display | 3-digit high-brightness, wide-viewing-angle LED |
| Power Supply | 120 V or 230 V AC, 50/60 Hz selectable |
| Drain Valve | Integrated on models ≥12 L capacity |
| Heating Power | 0.13–2.1 kW (model-dependent) |
| Compliance | DIN 12876-1:2013 Class I (laboratory water baths), CE marked, RoHS compliant |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | T100 R |
| Temperature Range | 0 to 100 °C |
| Stability | ±0.1 °C (DIN 12876, water @ 10 °C) |
| Refrigerant | R134a |
| Control | Adaptive Smart PID with Intelligent Control Optimization (ICO™) |
| Display | 4-digit LED |
| Communication | USB & RS232 (TX150/TXF200 models) |
| Pump Flow Rate | Up to 23 L/min (adjustable) |
| Max Pressure | 530 mbar |
| Safety Features | Adjustable overtemperature cut-off, low-level float switch, anti-freeze protection, 100 °C hardware limit |
| Brand | Grant |
|---|---|
| Origin | UK |
| Model | TC120 R |
| Temperature Range | −20 °C to +100 °C |
| Stability | ±0.1 °C (DIN 12876, water @ 10 °C) |
| Pump Flow Rate | up to 16 L/min |
| Display | 4-digit LED |
| Control | Adaptive Smart PID with Intelligent Control Optimization (ICO™) |
| Calibration | User-accessible two-point self-calibration |
| Safety Features | Adjustable overtemperature cutoff, low-level float switch, audible alarm |
| Communication | RS232 & USB (with Labwise™ software support) |
| Compliance | DIN 12876 Class I, CE, RoHS |