| Brand | Safematic |
|---|---|
| Origin | Switzerland |
| Model | CCU-010 LV |
| Instrument Type | Benchtop Coating System |
| Secondary Electron Image Resolution | 3–8 nm |
| Maximum Magnification | <100,000× |
| Accelerating Voltage | 0.5–30 kV |
| Sample Stage | ≥60 mm diameter, height-adjustable, tilt-capable, optional planetary or rotation stage |
| Brand | Safematic |
|---|---|
| Origin | Switzerland |
| Model | CCU-010 LV_SP |
| Vacuum Type | Low-Vacuum Magnetron Sputtering System |
| Coating Modes | Ion Sputtering (Au, Pt, Pd, Cr, Ir, etc.) and Optional Plasma Etching |
| Base Pressure | ≤5 × 10⁻² mbar (with dual-stage rotary vane pump) |
| Pumping Speed | <90 s to operational vacuum (≤1 × 10⁻¹ mbar) |
| Sputtering Target Diameter | 50 mm |
| Film Thickness Monitoring | Dual-position quartz crystal microbalance (QCM) with real-time thickness readout |
| Cooling | Active water-cooled sputter head |
| Plasma Etching Module | ET-010 (Ar, O₂, air configurable) |
| Control Interface | TFT touchscreen + optional RC-010 Windows-based remote software |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Sample Stage | Ø ≥60 mm, height-adjustable & tilt-capable |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SPG-80T |
| Price Range | USD 715 – 1,428 |
| Light Sources | CIE D65 (6500 K) & Illuminant A (2900 K) |
| CRI | >96 |
| Viewing Surface | 1050 mm × 700 mm |
| Overall Dimensions | 2100 mm (L) × 850 mm (W) × 125 mm (H) |
| Net Weight | 40 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | CIE No. 51, ISO 3664:2009, CY/T 3–1991 |
| Features | Spectral stability, uniform irradiance, metamerism evaluation mode, auto-lamp-hour counter, tilt-angle reflective hood, sample mounting board & storage tray |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHIRVOC100 |
| Operating Temperature | Cooled Detector Operation |
| Measurement Method | Non-Contact Optical Imaging |
| Spectral Range | 3.2–3.5 µm |
| Thermal Sensitivity (NETD) | ≤15 mK @ 25 °C |
| Infrared Resolution | 320 × 256 |
| Enclosure Rating | IP54 |
| Explosion Protection | Intrinsic Safety (Ex ib IIB T4 Gb) |
| Application Domain | Environmental Compliance Monitoring, Industrial Leak Detection, Regulatory Field Enforcement |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | TN100 |
| Price | USD 420 (FOB Shanghai) |
| Type | Portable |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging |
| Resolution | 0.01 NTU (0–19.99 NTU), 0.1 NTU (20.0–99.9 NTU), 1 NTU (100–1000 NTU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±8% FS |
| Repeatability | ≤ ±1.0% |
| Zero Drift | ≤ ±0.5% FS / 30 min |
| Stability | ≤ ±1.0% FS / 30 min |
| Detection Principle | 90° Nephelometric Scattering |
| Light Source | Infrared LED (860 ± 30 nm) |
| Detector | Silicon Photodiode |
| Calibration Standards | Polymer-based certified standards (0, 20, 100, 400, 800 NTU/FNU), EPA & ASTM compliant |
| Display | 3.5″ TFT color LCD with multilingual GUI (English, Chinese, Spanish) |
| Sample Cell | Borosilicate glass vial (Φ25 × 60 mm, 18 mL capacity) |
| Enclosure Rating | IP67 |
| Power | 4 × AA alkaline batteries |
| Dimensions (Instrument) | 90 × 203 × 80 mm |
| Weight (Instrument) | 385 g |
| Warranty | 2 years (instrument), 1 year (calibration standards) |
| Certifications | ISO 9001:2015, CE, compliant with HJ 1075–2019, ISO 7027:2016, DIN 27027 |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | TN150 |
| Type | Portable |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), 100–1000 NTU (FNU) |
| Resolution | 0.01 / 0.1 / 1 NTU (FNU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±8% |
| IP Rating | IP67 |
| Display | TFT color screen |
| Light Source | Tungsten filament lamp (400–600 nm) |
| Detection Principle | 90° nephelometric scattering |
| Compliance | HJ 1075–2019, EPA Method 180.1, ASTM D6508, ISO 7027–1:2016 (white light mode) |
| Calibration Standards | Certified polymer standards (0, 20, 100, 400, 800 NTU/FNU), EPA- and ASTM-compliant, 1-year shelf life |
| Battery | Rechargeable 3.7 V Li-ion (7 V system equivalent), >20 h continuous operation |
| Dimensions (instrument) | 90 × 203 × 80 mm |
| Weight (instrument) | 385 g |
| Certifications | ISO 9001:2015, CE |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TN150 |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), 100–1000 NTU (FNU) |
| Resolution | 0.01 / 0.1 / 1 NTU (FNU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±8% |
| IP Rating | IP67 |
| Calibration Standards | Certified polymer standards (0, 20, 100, 400, 800 NTU/FNU), EPA- and ASTM-compliant, 1-year shelf life |
| Power Supply | 3.7 V rechargeable Li-ion battery (7 V nominal output via internal regulation), >20 hours continuous operation |
| Display | TFT color screen with multilingual GUI (English, Chinese, Spanish) |
| Sample Cell | Borosilicate glass vial, Ø25 × 60 mm, 18 mL capacity |
| Compliance | HJ 1075–2019, EPA Method 180.1, ISO 7027–1:2016 (principle alignment), CE, ISO 9001:2015 |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Model | TN450 |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), and 100–1000 NTU (FNU) |
| Resolution | 0.01 / 0.1 / 1 NTU (FNU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±6% |
| Compliance | ISO 7027, HJ 1075–2019, DIN 27027 |
| IP Rating | IP67 |
| Data Storage | 200 GLP-compliant records |
| Interface | USB |
| Display | TFT color screen with multilingual UI (English, Chinese, Spanish) |
| Power | 4 × AA batteries |
| Dimensions (instrument) | 90 × 203 × 80 mm |
| Weight (instrument) | 385 g |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable |
| Model | TN450 |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU (FNU), 20.0–99.9 NTU (FNU), 100–1000 NTU (FNU) |
| Resolution | 0.01 / 0.1 / 1 NTU (FNU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±6% |
| IP Rating | IP67 |
| Calibration Standards | Certified polymer standards (0, 20, 100, 400, 800 NTU/FNU), EPA- and ASTM-compliant, 1-year shelf life |
| Data Storage | 200 GLP-compliant records with timestamp, USB interface |
| Display | TFT color screen with multilingual UI (English, Chinese, Spanish) |
| Power | 4 × AA batteries |
| Dimensions (instrument) | 90 × 203 × 80 mm |
| Weight (instrument) | 385 g |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Portable |
| Model | TN500 |
| Measurement Range | 0–1000 NTU (FNU), auto-ranging across three sub-ranges: 0.01–19.99 NTU, 20.0–99.9 NTU, and 100–1000 NTU |
| Resolution | 0.01 / 0.1 / 1 NTU |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤ ±6% |
| Compliance | HJ 1075–2019, EPA Method 180.1, ASTM D6508, ISO 7027–1:2016 (scattering mode) |
| IP Rating | IP67 |
| Data Storage | 200 GLP-compliant records with timestamp, calibration history, and operator ID support |
| Power | Rechargeable 3.7 V Li-ion battery (7 V system via internal boost), >20 h continuous operation |
| Display | 3.5″ TFT color LCD with multilingual GUI (English, Spanish, Chinese) |
| Calibration Standards | NIST-traceable polymer standards (0, 20, 100, 400, 800 NTU/FNU), EPA- and ASTM-certified, 12-month shelf life |
| Detector | Silicon photodiode |
| Light Source | Tungsten-halogen lamp (400–600 nm, broadband white light) |
| Measurement Principle | 90° nephelometric scattering |
| Sample Vessel | Borosilicate glass cuvette (Φ25 × 60 mm, 18 mL capacity) |
| Connectivity | USB 2.0 (data export, firmware update) |
| Enclosure | Ruggedized housing with IP67 ingress protection |
| Brand | Coherent |
|---|---|
| Origin | USA |
| Model | Sapphire FP Series |
| Wavelength | 488 nm |
| Output Type | Fiber-Coupled (FC/PC or FC/APC optional) |
| Laser Medium | Solid-State (Diode-Pumped Nd:YAG / LBO frequency-doubled) |
| Cooling | Air-Cooled |
| Polarization | Linear, >100:1 |
| Power Stability | <±0.5% RMS over 8 hours |
| Beam Pointing Stability | <5 µrad/°C |
| Lifetime | >10,000 hours MTBF |
| Compliance | CE, RoHS, FDA 21 CFR Part 1040.10 (Laser Product Safety) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC20 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | scanDelay USB Optical Delay |
| Price Range | USD $1,400 – $7,200 (est.) |
| Component Category | Optical Element |
| Max. Scan Range | 15 ps (±1.125 mm) / 50 ps (±3.75 mm) / 150 ps (±11.25 mm) |
| Internal Generator Frequency | 0.1–20 Hz (15 ps & 50 ps models), 0.1–10 Hz (150 ps model) |
| Externally Triggered Frequency Range | 0.01–20 Hz (15 ps & 50 ps), 0.01–10 Hz (150 ps) |
| External Trigger Input | TTL, 20 Hz – <50 kHz (optional fast frequency divider supports ~80 MHz input) |
| Trigger Output | TTL |
| Position Output Signal | ±10 V full scale per delay range |
| Linearity of Position Signal | <0.5% |
| Computer Interface | USB 2.0 |
| Clear Aperture | 1″ (15 ps), 1/2″ (50 ps & 150 ps) |
| Mirror Coating | Protected silver (standard) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Scanner16-z |
| Product Type | Motorized Translation Stage |
| Vacuum Compatibility | UHV (2×10⁻¹¹ mbar) |
| Cryogenic Compatibility | 30 mK |
| Magnetic Field Compatibility | Up to 18 T |
| Body Material | Pure Titanium & Beryllium Copper |
| Travel (300 K) | 30 µm |
| Resolution | 0.5 nm |
| Load Capacity | 100 g |
| Drive Voltage (300 K) | ≤75 V |
| Drive Voltage (4 K) | ≤180 V |
| Capacitance (300 K) | 0.8 µF |
| Linearity Error | ~0.1% (typ.) |
| Repeatability | <10 nm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | Scanner55-z |
| Pricing | Upon Request |
| Product Type | Motorized Translation Stage |
| Dimensions | 55 × 55 × 16.5 mm |
| Vacuum Compatibility | ≤2 × 10⁻¹¹ mbar |
| Cryogenic Compatibility | Down to 30 mK |
| Magnetic Field Compatibility | Up to 18 T (non-magnetic construction: pure titanium & beryllium copper) |
| Load Capacity | 500 g |
| Travel Range at 300 K | 120 µm |
| Positioning Resolution | 2 nm |
| Brand | ScanSci |
|---|---|
| Model | ScanSource |
| Spectral Range | 200–1100 nm (standard), optional down to 180 nm |
| Lamp Types | Deuterium (D₂) + Tungsten-Halogen (W) |
| Deuterium Power | 30 W |
| Tungsten Power | 9 W |
| Output Stability (Fluctuation) | ≤2×10⁻⁵ A.U. |
| Long-Term Drift | ±0.3 %/h (D₂), ±0.25 %/h (W) |
| External Control | Shutter, Lamp On/Off, Main Power On/Off |
| Fiber Coupling | SMA 905 |
| Deuterium Lamp Lifetime | 2000 h |
| Tungsten Lamp Lifetime | 2000 h |
| Cooling | Active (fan-cooled) |
| Dimensions | 157 × 178 × 250 mm |
| Compliance | CE, RoHS |
| Brand | Schafter + Kirchhoff |
|---|---|
| Origin | Germany |
| Model | SK010PA |
| Interface | USB 2.0 (powered via USB) |
| Output | Real-time Stokes parameters (S₀–S₃), Degree of Polarization (DOP), Ellipticity, Azimuth |
| Display | Interactive Poincaré sphere visualization |
| Compliance | CE-marked, RoHS-compliant |
| Optical Input | Free-space beam or polarization-maintaining (PM) fiber-coupled sources |
| Calibration | Factory-calibrated with NIST-traceable reference standards |
| Brand | Schafter+Kirchhoff |
|---|---|
| Origin | Germany |
| Model | 60FC-0-M5-33 (and variants) |
| Lens Options | 17 achromatic & apochromatic types |
| Material Options | Nickel alloy, stainless steel, titanium |
| Bearing Type | Carbide |
| Locking | Focus position lock & fiber clamping |
| AR Coating | >99.9% transmission (typical, wavelength-dependent) |
| Beam Diameter Range (collimated output) | 3.6–36 mm |
| Focal Spot Diameter Range | 20–200 µm |
| Wavelength Compatibility | UV-VIS-NIR (model-specific, e.g., RGBV: 400–670 nm) |
| NA Support | Up to 0.22 (fiber-dependent) |
| Adjustment | Precision threaded, rotation-free lens translation |
| Polarization Alignment | Integrated polarization-maintaining fiber interface |
| Brand | Schafter+Kirchhoff |
|---|---|
| Origin | Germany |
| Model | SK010PA Series |
| Power Range | 0.01–50 mW |
| Angular Accuracy (η, χ) | ±0.4° |
| PER Accuracy | ±0.5 dB |
| DOP Accuracy | ±5% |
| SOP Accuracy (on Poincaré sphere) | ±0.2° |
| Free-Space Beam Diameter Max | 4 mm |
| Sampling Rate | 15 Hz |
| Sensor Active Area | 2.85 × 2.85 mm² |
| Dimensions (W×L×H) | 40 × 70 × 82 mm |
| Interface | USB 2.0 (data + power) |
| Standard Fiber Adapter | FC-APC |
| Optional Adapters | FC-PC, DIN AVIO, ST |
| Software | SKPolarimeter |
| Development Support | LabVIEW VI Library & DLL API |
| Compliance | CE, RoHS |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | ATR-BR |
| Product Type | In-line / Laboratory Refractometer |
| Temperature Control | Integrated Peltier-free prism temperature sensing |
| Digital Display | Backlit LCD (16×16 characters) |
| Measurement Range | 1.32000–1.54000 RI / 0–100 %Brix |
| Resolution | 0.00001 RI / 0.01 %Brix |
| Accuracy | ±0.00002 RI / ±0.01 %Brix (1.32–1.44), ±0.00003 RI / ±0.01 %Brix (1.44–1.54) |
| Repeatability | 0.00001 RI / 0.01 %Brix |
| Temperature Sensing | NTC sensor embedded in sapphire prism, accuracy ±0.03 °C, repeatability ±0.02 °C |
| Sample Volume | 0.3 mL |
| Prism Material | Sapphire |
| Light Source | LED with integrated interference filter, λ = 589 nm |
| Interfaces | RS-232C (bidirectional), Centronics parallel port, USB (optional) |
| Compliance | ASTM D1218, DIN 51757, ISO 21542, USP <781>, ICUMSA Method GS2/3-13, AOAC 932.12, FDA 21 CFR Part 11 (with optional audit trail software) |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | ATR-L |
| Product Type | In-line Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.33200–1.70000 RI / 0–100% Brix |
| Measurement Accuracy | ±0.00001 RI / ±0.01 Brix |
| Temperature Control Range | 10–80 °C |
| Temperature Accuracy | ±0.03 °C |
| Wavelengths | 400, 450, 490, 525, 589, 660, 700 nm (LED-based) |
| Prism Material | YAG |
| Detection Principle | Critical Angle of Total Internal Reflection (ATR) |
| Sensor | CCD array |
| Compliance | ASTM, ISO, AOAC, DIN, ICUMSA, USP, FDA 21 CFR Part 11 (software-enabled), GLP/GMP-ready |
| Key | Brand: Schmidt + Haensch |
|---|---|
| Origin | Germany |
| Model | ATR-P |
| Type | Inline Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.32000–1.54000 RI / 0–100 % Brix |
| Resolution | 0.00001 RI / 0.01 % Brix |
| Accuracy | ±0.00002 RI / ±0.02 % Brix |
| Repeatability | ±0.00001 RI / ±0.01 % Brix |
| Temperature Range (Sample) | +5 to +50 °C |
| Temperature Accuracy | ±0.03 °C |
| Wavelength | 589 nm (LED with interference filter) |
| Prism Material | Sapphire |
| Display | 7″ TFT touchscreen (800 × 480 px, 16-bit color) |
| Interface | 2× RS232, 3× USB-A, 1× USB-B, 1× Ethernet |
| Compliance | ASTM E1220, ICUMSA Method GS2/3-12, USP <851>, Ph. Eur. 2.2.29, GLP/GMP-ready |
| Brand | SCHMIDT + HAENSCH |
|---|---|
| Origin | Germany |
| Model | Coloromat 100 |
| Optical Principle | Single-beam spectrophotometry |
| Spectral Range | 420–900 nm |
| Fixed Wavelengths | 340, 420, 720 nm |
| Customizable Wavelengths | up to 6 additional (340–900 nm), total ≤9 |
| Extinction Accuracy | ±0.020 (340 & 420 nm), ±0.010 (720 nm), ±0.020 (other wavelengths) |
| ICUMSA Range | 0–16.000 IU |
| ICUMSA Accuracy | ±10% (<20 IU), ±5% (>20 IU) |
| Extinction Resolution | 0.001 |
| Light Source | 12 V / 20 W halogen lamp |
| Display | Graphical touchscreen interface |
| Interface | RS232C |
| Operating Temperature | 10–40 °C |
| Power Supply | 85–265 V AC, 47–63 Hz |
| Language Support | English & German (others on request) |
| Internal Method Storage | 250 pre-programmed methods (ROM), up to 230 user-defined methods (RAM) |
| Data Storage Capacity | 2970 measurements, 99 sample IDs |
| Compliance | GLP/GMP-compliant data handling, audit-trail-ready operation |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | DHR |
| Type | Digital handheld refractometer |
| Temperature control | Yes (ATC) |
| Digital display | Yes (5-digit LCD) |
| Measurement range | 0–95 °Brix / 1.3300–1.5400 RI |
| Resolution | 0.1 °Brix / 0.0001 RI |
| Accuracy | ±0.2 °Brix / ±0.0003 RI |
| Operating sample temperature | 5–60 °C |
| Ambient temperature range | 5–40 °C |
| ATC compensation range | 5–70 °C |
| IP rating | IP65 |
| Compliance | CE, RoHS |
| Power | 2×AAA batteries |
| Dimensions (L×W×H) | 115×54×30 mm |
| Weight | 85 g (without batteries) |
| Prism material | Optical glass |
| Brand | SCHMIDT + HAENSCH |
|---|---|
| Origin | Germany |
| Model | Polartronic V |
| Sample Tube Length | up to 200 mm |
| Measurement Range | ±360° / ±259°Z |
| Accuracy | ±0.005° / ±0.015°Z |
| Resolution | 0.001° / 0.01°Z |
| Repeatability | ±0.005° / ±0.015°Z |
| Wavelength Options | 589 nm (Na-D), 882 nm, or dual-wavelength (589 & 882 nm) |
| Light Source | Long-life LED |
| Temperature Control | External Peltier or water bath (18–40 °C, ±0.03 °C accuracy) |
| Optical Density Range | Up to OD 5 |
| Response Time | ~4 s |
| Display | 7" TFT touchscreen (800×480, 16-bit color) |
| Interfaces | RS232 ×1, USB-A ×4, USB-B ×1, Ethernet ×1, Analog output, optional WLAN/LAN |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 ready |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principles | Conductivity-based Ash Determination, Photometric Colorimetry at 420 nm (ICUMSA), Nephelometric Turbidity |
| Accuracy | ±1 IU (Color, ≤30 IU), ±10% (Turbidity), ±0.001% (Ash), ±0.1 °Brix (Brix) |
| Compliance | ICUMSA Method GS5/8/9-1, ASTM D1209, ISO 7027, USP <731> |
| Automation Level | Fully Automated Sample Handling, Dilution, Filtration, Measurement, and System Rinse |
| Software Integration | LIMS-ready with audit-trail-capable data acquisition, FDA 21 CFR Part 11–compliant optional module |
| Sample Throughput | ~3 samples/hour |
| Sample Format | Pre-weighed white sugar solids (barcoded) |
| Brand | Schmidt + Haensch |
|---|---|
| Origin | Germany |
| Model | Saccharoflex 2020 |
| Measurement Principle | Reflectance Photometry |
| Wavelengths | 495 nm and 620 nm |
| ICUMSA Method Compliance | GS2-11 (1994) and GS2-13 (1994) |
| Range | 0–19.99 ICUMSA Color Units (CU) |
| Resolution | 0.01 CU |
| Accuracy | ±0.15 CU |
| Repeatability | ±0.15 CU |
| Light Source | 12 V / 20 W Halogen Lamp |
| Display | Backlit LCD |
| Interface | RS-232C and USB-B |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Language Support | English and German |
| Calibration Standards | Brunswick ceramic reference tiles (CU 0 and CU 6 recommended) |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | Saccharomat V |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (external or Peltier-based) |
| Digital Display | Yes |
| Light Source | LED |
| Measurement Range | −35 to +105 °Z |
| Measurement Resolution | 0.01 °Z |
| Accuracy | ±0.01 °Z |
| Photometric Sensitivity | up to OD 5 |
| Response Time | ~4 s |
| Wavelength Options | 587.6 nm (D-line), 882.6 nm (NIR), or dual-wavelength configuration |
| Temperature Control Range (with thermostatted cell) | 18–40 °C |
| Temperature Accuracy (with T-Cell) | ±0.03 °C |
| Repeatability | 0.01 °Z |
| Optical Path Length | up to 200 mm |
| Display | 7″ TFT touchscreen (800 × 480 px, 16-bit color) |
| Interfaces | RS232 ×1, USB-A ×4, USB-B ×1, Ethernet ×1, Analog output, optional WLAN/LAN |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible software architecture |
| Brand | SCHMIDT + HAENSCH |
|---|---|
| Origin | Germany |
| Model | UniPol V |
| Sample Measurement Range | ±360° / ±259°Z |
| Angular Accuracy | ±0.005° / ±0.02°Z |
| Angular Resolution | 0.001° / 0.01°Z |
| Wavelength | 589 nm (LED) |
| Temperature Control | External Circulating Bath Interface |
| Display | Graphical LCD (16×16 characters) |
| Interfaces | 2× RS-232, 1× Parallel, PS/2, USB*, Ethernet* |
| Compliance | ASTM E1254, USP <781>, Ph. Eur. 2.2.7, FDA 21 CFR Part 11 (with optional audit trail software) |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariPol |
| Product Type | Automated Polarimeter |
| Temperature Control | Peltier-regulated |
| Display | Digital Touchscreen |
| Light Source | LED with Interference Filter |
| Temperature Range | 10–40 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Optical Rotation Accuracy | ±0.01° (VariPol C), ±0.005° (VariPol B) |
| Optical Rotation Resolution | 0.001° |
| Repeatability | ±0.01° (VariPol C), ±0.005° (VariPol B) |
| Wavelength | Standard 589 nm (Na-D line), customizable between 365–882 nm |
| Measurement Time | 6–8 s |
| Optical Path Length Compatibility | Up to 100 mm |
| Detector Dynamic Range | OD 3 |
| Interface Options | 3× USB, 1× RS-232, 1× Ethernet (LAN), optional Modbus, CAN bus, WLAN |
| Dimensions | 430 × 300 × 160 mm (W × D × H) |
| Compliance | 21 CFR Part 11, USP <781>, Ph. Eur. 2.2.7, JP 2.03 |