Optical Instruments
Filter
Showing 1111–1140 of 7811 results
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | SAC-i 589/882 |
| Type | Fully Automatic Polarimeter |
| Temperature Control | Integrated Peltier-based Thermostat (10–40 °C) |
| Display | 7.5″ Color LCD Touchscreen |
| Light Source | LED with Interference Filters at 589 nm and 882 nm |
| Measurement Range | –89.9999 to +90.0000° (AR) and –360.0000 to +360.0000° (AR extended) |
| Resolution | 0.0001° (AR), 0.0001°Z (ISS) |
| Accuracy | ±0.002° (AR, –5.0000 to +5.0000° @ 589 nm), ±0.010° (AR, full range) |
| Repeatability | ±0.003° (AR) |
| Sample Cell Compatibility | Up to 200 mm path length |
| Compliance | ICUMSA Method GS3/3-12, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready |
| Data Output | USB flash drive (CSV), RS-232C, optional DP-AD/DP-63 thermal printer |
| Interface | Front-mounted USB-A port, touchscreen GUI with 6 UI themes and dual background options |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | SAC-i (Dual-Wavelength) |
| Product Type | Automated Polarimeter |
| Temperature Control | Integrated Peltier-based thermostatic system (10–50 °C, ±0.2 °C) |
| Display | 7.5″ color touchscreen LCD |
| Light Source | LED with interference filters at 589 nm and 882 nm |
| Measurement Range | Optical Rotation: −89.9999 to +90.0000° and −360.0000 to +360.0000° |
| International Sugar Scale (ISS) | −259.0000 to +259.0000°Z |
| Resolution | 0.0001° (rotation), 0.0001°Z (ISS) |
| Accuracy (589 nm) | ±0.002° (−5 to +5°), ±0.005° (±5° to ±45°), ±0.01° (>±45°) |
| ISS | ±0.015°Z (−130 to +130°Z), ±0.010°Z (within full rotation range) |
| Accuracy (882 nm) | ±0.002° (−5 to +5°), ±0.005° (−19.3 to +19.3°) |
| ISS | ±0.0150°Z (−130 to +130°Z) |
| Repeatability | ±0.003° |
| Measurement Modes | Manual Standard, Auto Standard, High-Speed Auto, Stability-Triggered Auto |
| Max Cell Length | 200 mm |
| Interface | Front-mounted USB port |
| Compliance | ICUMSA Method GS4/3-11, FDA 21 CFR Part 11 (audit trail, electronic signature support), GLP/GMP-ready data management |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | SMART-1 |
| Measurement Principle | Abbe Refraction |
| Measurement Range | Brix 0.00–95.00%, Invert Sugar 0.00–95.00%, HFCS-42 0.00–95.00%, HFCS-55 0.00–95.00% |
| Resolution | 0.01% for all scales |
| Accuracy | ±0.05% for all scales |
| Repeatability | ±0.01% |
| Temperature Compensation | Automatic (5.00–40.00 °C) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 15 VA |
| IP Rating | IP64 (main unit) |
| Interface | RS-232C |
| Dimensions (H×W×D) | 12×27×9 cm |
| Weight | 2.0 kg (main unit), 0.7 kg (AC adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | SMART-1 |
| Product Type | Benchtop Refractometer |
| Display | Digital LCD |
| Measurement Range | 0.00–95.00 % Brix |
| Temperature Range for Measurement | 5.00–40.00 °C |
| Temperature Compensation | Automatic (ATC, based on built-in thermistor) |
| Compliance | ISO 2173, AOAC 932.12, ICUMSA Methods |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | SMART-1 |
| Measurement Principle | Automatic Temperature-Compensated Digital Refractometry |
| Measuring Range | Brix 0.00–95.00%, Inverted Sugar 0.00–95.00%, HFCS-42 0.00–95.00%, HFCS-55 0.00–95.00% |
| Resolution | 0.01% for all scales |
| Accuracy | ±0.05% for all scales |
| Temperature Range | 5.00–40.00 °C |
| Output Interface | RS-232C (printer & PC compatible) |
| IP Rating | IP64 (excluding AC adapter) |
| Power Supply | AC adapter (100–240 V, 50/60 Hz) |
| Power Consumption | 15 VA |
| Dimensions (main unit) | 12 × 27 × 9 cm |
| Weight (main unit) | 2.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | T3-NE |
| Measurement Range | 1.333–1.360 RI |
| Resolution | 0.001 RI |
| Temperature Control | Yes |
| Digital Display | Yes |
| Instrument Type | Benchtop Refractometer |
| Scale Types | Urine Specific Gravity (USG), Serum Protein (g/dL), and Refractive Index (RI) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | T3-RX/RI |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Brix Range | 0.0–18.0% |
| RI Range | 1.3300–1.3605 |
| Brix Resolution | 0.2% |
| RI Resolution | 0.0005 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | UG-α |
| Type | Handheld Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.0000–1.0600 |
| Accuracy | ±0.001 |
| Compliance | ISO 17025 traceable calibration capability (per ATAGO factory standard) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | UG-α (Urine Specific Gravity) |
| Product Type | Handheld Refractometer |
| Temperature Control | None |
| Digital Display | Yes |
| Measurement Range | 1.0000–1.0600 |
| Accuracy | ±0.0010 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | WM-7 |
| Product Type | Handheld Refractometer |
| Brix Range | 0.0–45.0% |
| Brix Resolution | 0.1% |
| Brix Accuracy | ±0.1% |
| Temperature Compensation | Automatic (5–40°C) |
| Measurement Time | 3 seconds |
| Display Scales | 7 (Brix, TA-1990, TA-1971, °Oe GER, °Oe, °KMW, °Bé) |
| IP Rating | IP65 |
| Power | 9V alkaline battery (006P) |
| Dimensions | 17 × 9 × 4 cm |
| Weight | 270 g (instrument only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | WM-7 |
| Measurement Principle | Abbe Refraction (Critical Angle Method) |
| Measurement Range | Brix 0.0–45.0%, TA 1990 0.0–26.0%, TA 1971 0.0–25.0%, °Oe (GER) 0–240, °Oe (General) 0–240, KMW (°Babo) 0.0–40.0, °Bé 0.0–21.0 |
| Resolution | Brix 0.1%, TA 0.1%, KMW 0.1°, °Bé 0.1°, °Oe 1° |
| Accuracy | ±0.1% Brix, ±0.2% TA, ±0.2° KMW, ±0.2° Bé, ±1° Oe |
| Response Time | 3 s |
| Temperature Compensation | Automatic (5–40°C sample temp |
| IP Rating | IP64 |
| Power | 9V alkaline battery (006P) |
| Dimensions | 170 × 90 × 40 mm |
| Weight | 300 g (instrument only) |
| Compliance | ICUMSA, OIV, DIN 38405, ISO 2173 |
| Brand | Atik Cameras |
|---|---|
| Sensor Type | Sony CCD (ICX-694) |
| Model | VS60-C-F |
| Resolution | 2750 × 2205 |
| Effective Pixels | 6.0 MP |
| Pixel Size | 4.54 µm |
| Color | Yes |
| Filter Wheel | Integrated |
| Sensor Format | 15.99 mm diagonal |
| Mount | C-mount / M42 optional |
| Cooling | Thermoelectric (TE), regulated to −20°C below ambient |
| Read Noise | <9 e⁻ (at 0.1 MHz) |
| Full Well Capacity | ~15,000 e⁻ |
| Interface | USB 2.0 with galvanic isolation |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Atik Cameras |
|---|---|
| Sensor | Sony ICX-285 |
| Format | 2/3" |
| Resolution | 1392 × 1040 |
| Effective Pixels | 1.4 MP |
| Pixel Size | 6.45 µm |
| Cooling | Integrated Thermoelectric (TE) to −35 °C |
| Bit Depth | 16-bit |
| Interface | USB 2.0 |
| Filter Wheel Option | Built-in 5-position motorized filter wheel (F-model) |
| Compliance | ISO 9001-certified manufacturing |
| SDK | Full C++ API, .NET wrappers, ImageJ plugin, LabVIEW VIs, Linux & VB drivers |
| Brand | Atik Instruments |
|---|---|
| Sensor Resolution | 2750 × 2205 pixels |
| Sensor Type | Monochrome back-illuminated CCD |
| Pixel Size | 4.54 µm × 4.54 µm |
| Full Well Capacity | ~15,000 e⁻ |
| Read Noise | <9 e⁻ (at 0.1 MHz) |
| Dark Current | <0.001 e⁻/pixel/sec @ −20°C |
| Cooling | Thermoelectric (TE) to −20°C below ambient |
| Interface | USB 2.0 |
| Shutter | Mechanical (optional electronic shutter) |
| Compliance | CE, RoHS |
| Software Support | ASCOM, DirectShow, LabVIEW, MATLAB, Python (via SDK) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ATLEX |
| Price | USD 55,000 (FOB Hamburg) |
| Core Technology | Gas-based Pulsed UV Excimer Laser System |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WAD-1202S |
| Pricing | Available Upon Request |
| Brand | Truth Instruments Company Limited |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AtomEdge Pro |
| Pricing | Available Upon Request |
| Brand | Atometrics |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | AF-T050 |
| Pricing | Available Upon Request |
| Brand | Atometrics |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model Series | AH Series |
| Imaging Sensor | CMOS |
| XY Stage Dimensions | 220 mm × 180 mm |
| Frame Rate | 30 FPS |
| 3D Image Comparison Function | Yes |
| Maximum Optical Magnification | 500× |
| Brand | Atometrics |
|---|---|
| Model | AP-5005 |
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Pricing | Upon Request |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Model | newopto |
| Fiber Type | Chalcogenide (CIR) / Polycrystalline (PIR) |
| Transmission Range | 6500–1700 cm⁻¹ (CIR) / 3600–600 cm⁻¹ (PIR) |
| Max. Temp. | ≤90°C (CIR) / ≤100°C (PIR) |
| Total Length | 1 m (standard) |
| Shaft Length | 120 mm |
| Shaft Diameter | 10 mm |
| Shaft Material | PEEK |
| Protective Tube Material | PEEK |
| Connector | Long SMA (custom options available) |
| Detachable Loop Configuration | Single-loop, double-loop, triple-loop, and multi-loop variants |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | APC Femtosecond Pulse Compressor |
| Core Component | Prism-Based Dispersion Compensation Unit |
| Wavelength Range | 700–900 nm (customizable) |
| GVD Tuning Range @ 800 nm | +16,500 to −13,800 fs² (APC Pro DF) |
| Transmission | >90% @ 800 nm |
| Beam Diameter | Up to 4 mm |
| Polarization | Linear, horizontal (vertical optional) |
| Prism Materials | Fused Silica & Dense Flint Glass |
| Dimensions (APC Pro DF) | 410 × 324 × 186 mm |
| Compliance | Designed for ultrafast laser systems compliant with ISO 11146 (laser beam parameters) and IEC 60825-1 (laser safety) |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | IRA-0.45-3 |
| Wavelength Range | 450 nm – 11 µm |
| Pulse Duration Range | 50 fs – 250 ps |
| Input Pulse Energy (typ.) | >1 nJ (50 fs–1 ps, thin NL crystal) / >3 nJ (1–250 ps, thick NL crystal) |
| Max. Avg. Input Power | 1 W |
| Repetition Rate | 10 Hz – 100 MHz |
| Polarization | Linear, horizontal |
| Delay Line Time Resolution | 8.3 fs |
| Full Scan Range | 850 ps |
| Interface | USB |
| Software | Windows-based acquisition & analysis suite |
| Dimensions (Optical Unit) | 450 × 250 × 210 mm |
| Dimensions (Control Unit) | 250 × 180 × 90 mm |
| Power Supply | 110/220 V, 50/60 Hz ±10% |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | OA |
| Dynamic Attenuation Range | >10² |
| Input Pulse Duration | <50 fs (OAFP), >50 fs (OAGP), >70 fs (OABS) |
| Center Wavelength Options | 343–350 nm, 450–1600 nm (configurable), typical: 515 nm / 800 nm / 1030 nm |
| Bandwidth | 5% (OAFP), 10–12% (OAGP/OABS) of center wavelength |
| Transmission | >92% (OAFP), >90% (OAGP), >85% (OABS) |
| Clear Aperture | <10 mm (OAFP/OAGP-10/OABS-9), <6 mm (OAGP-6), <15 mm (OABS-15) |
| Beam Walk-off | <40 mm (OAFP), <1 mrad (OAGP/OABS) |
| Damage Threshold | 10 J/cm² (OAFP/OAGP-10/OABS-15), 5 J/cm² (OAGP-6) |
| Drive Type | Manual (-M), Manual with Side Knob (-MK), or Stepper Motor–Driven USB-Controlled (-S), step resolution: 0.1% per step |
| Spectral Range | 250–2000 nm |
| Polarization-Based Attenuation Principle | Rotating Waveplate + Polarizer Architecture |
| Brand | ATSEVA |
|---|---|
| Model | OCV-6300F |
| Type | Optical Mechanical Chopper |
| Frequency Range | 7–6300 Hz (dependent on chopper blade configuration) |
| Blade Options | 2-, 10-, 30-, 60-, and 100-slot |
| Sync Output | +5 V, 50 Ω TTL-compatible |
| Frequency Accuracy | ±1 Hz |
| Power Supply | AC 100–230 V, 50/60 Hz → DC 12 V, 0.35 A adapter |
| Power Consumption | 4 W |
| Dimensions (OCV-6300F) | 87 × 104 × 148 mm (W × L × H) |
| Integrated Frequency Counter | Yes |
| Compliance | CE-marked, RoHS-compliant |
| Operating Environment | 15–35 °C, <80% RH non-condensing |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | OG-B/F |
| Core Components | Pockels Cell, High-Voltage Gate Driver, Synchronization & Delay Module |
| Wavelength Ranges | 340–1280 nm (OG-F), 200–2200 nm (OG-B), 1000–2700 nm (OG-B-R/K) |
| Max Repetition Rate | 1 MHz (OG-B-R/K), 100 kHz (OG-B), 1 kHz (OG-F) |
| Minimum Repetition Rate | Single-shot |
| Aperture | Up to 20 mm (OG-B), 6 mm (OG-F), 3.5 mm (OG-B-R/K) |
| HV Gate Pulse Width (10% level) | 3 ns (OG-F), 8 ns (OG-B), 8 ns (OG-B-R/K) |
| Rise Time (10–90%) | 700 ps (OG-F), 3.5 ns (OG-B/OG-B-R/K) |
| Contrast Ratio | >1500:1 (OG-F), >700:1 (OG-B), >800:1 (OG-B-R/K) |
| Pockels Cell Voltage | up to 10 kV (OG-F), up to 4 kV (OG-B), up to 3 kV (OG-B-R/K) |
| Transmission | >85% (standard GT prism + PC), >98% (PC only) |
| Trigger Options | Internal/External, Optical/Electrical, Edge/Level/Burst Mode |
| Channel Delay Range | 0–10 µs (OG-F), 0–1 µs (OG-B/OG-B-R/K), extendable per request |
| Cooling | Passive ≤3 kHz |
| Brand | ATSEVA |
|---|---|
| Model | SP |
| Type | Spectral Phase Interferometry for Direct Electric-field Reconstruction Instrument |
| Origin | Russia |
| Import Status | Imported |
| Interface | USB 2.0 |
| Operating Mode | Single-shot & Real-time |
| Input Polarization | Linear, Horizontal |
| Dimensions (w×d×h) | 361 × 210 × 145 mm (SP-800-5), 385 × 295 × 125 mm (SP-800-10 & SP-1000-20) |
| Spectral Range Options | 550–1050 nm |
| Transform-Limited Pulse Width Coverage | 5–12 fs to 80–320 fs (model-dependent) |
| Sensitivity | ≥1 µJ per pulse (single-shot mode) |
| Detection | Dual-channel CCD spectrometer integrated |
| Data Processing | Linear, non-iterative Fourier-domain reconstruction algorithm |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | TiC |
| Type | Solid-State CW Tunable Laser Oscillator |
| Tuning Range | 700–1000 nm (standard), extendable to 690–1060 nm |
| Output Power | >1.8 W @ 800 nm (free-space), up to 1.2 W (fiber-coupled, 4 µm core) |
| Linewidth | <45 GHz (default), <20 GHz (with one intra-cavity etalon), <2 GHz (with two intra-cavity etalons) |
| Pump Requirement | CW DPSS or Ar⁺-Ion laser at 480–550 nm (typically 532 nm), 2–10 W |
| Beam Quality | TEM₀₀, M² < 1.2 |
| Polarization | Linear, horizontal, PER > 100:1 |
| Power Stability | <0.2 % rms (12 h, after 30-min warm-up, with closed-loop chiller & certified pump laser) |
| Control Interface | USB-connected stepper motor actuation, Windows-based software suite (Basic/AU/Automatic packages) |
| Optional Features | Integrated spectrometer, power meter, active power stabilization, fiber coupling (SMF, FC connector), BRF control |
| Brand | attocube |
|---|---|
| Origin | Germany |
| Model | attoCFM I |
| Instrument Type | Cryogenic Confocal Microscope for Quantum Materials Research |
| Positioning Noise | < 0.5 nm |
| Sample Size Capacity | Ø100 mm |
| Sample Stage Travel Range | 150 µm (fine scan) / 5 × 5 × 5 mm³ (coarse positioning) |
| Temperature Range | 1.8 K – 300 K |
| Magnetic Field | Up to 12 T (vector magnet optional) |
| Vacuum Operating Range | 1 × 10⁻⁶ mbar – 1 atm |
| Optical Resolution | ~550 nm (at 635 nm, NA = 0.82) |
| Scan Area | 30 × 30 µm² @ 4 K |
| Objective | Cryo-optimized Achromatic Objective, NA = 0.82, WD = 0.7 mm |
| Expandable Modules | AFM/MFM/PFM/KPFM/ct-AFM/cryo-Raman |
| Brand | attocube |
|---|---|
| Origin | Germany |
| Model | attoCFM I |
| Instrument Type | Magnetic Force Microscope (MFM) / Cryogenic Confocal Microscope |
| Positioning Noise | < 0.5 nm |
| Sample Size Capacity | Ø100 mm |
| Sample Stage Travel Range | 150 µm (fine scan) / 5 × 5 × 5 mm³ (coarse positioning) |
| Temperature Range | 1.8 K – 300 K |
| Magnetic Field | Up to 12 T (vector magnet optional) |
| Vacuum Operation | 1 × 10⁻⁶ mbar – 1 atm |
| Numerical Aperture (NA) | 0.82 |
| Optical Resolution | ~550 nm (@635 nm) |
| Working Distance (WD) | 0.7 mm |
| Confocal Scan Range | 30 × 30 µm² @4 K |
| Compatible Cryostats | attoDRY1000/2100, Quantum Design PPMS (1″/2″ bore) |
| Expandable Modules | AFM/MFM/PFM/KPFM/ct-AFM/cryo-Raman |