Other Gas Detection Instruments
Filter
Showing 61–90 of 107 results
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Language Options | English, French, Spanish, Portuguese, Chinese |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4–22 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Supported Languages | English, French, Spanish, Portuguese, Chinese |
| Max Simultaneous Units Controlled via PC | 4 |
| Data Export Format | Microsoft Excel |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Language Options | English, French, Spanish, Portuguese, Chinese |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch full-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units controlled simultaneously via single PC |
| Data Export Format | Microsoft Excel (.xlsx) |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4–18 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host×2, Device×1), Ethernet×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Max Simultaneous Units Controlled via PC | 4 |
| Data Export Format | Microsoft Excel |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C, 3000-C1 |
| Particle Size Range | 0.02–1.0 µm (3000-0C), 0.015–1.0 µm (3000-C1) |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation | Direct Cout/Cin ratio |
| Test Agent | ≥99.5% isopropanol or ethanol |
| Display | 7-inch full-color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 208×117×262 mm (3000-0C), 208×152×263 mm (3000-C1) |
| Weight | 2.3 kg (3000-0C), 3.1 kg (3000-C1) |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG 479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Software | Windows 7/8/10, .NET Framework 3.5, Excel-compatible reporting |
| Communication | USB, Ethernet, Wi-Fi |
| Multi-unit Control | Up to 4 units per PC |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-C1 |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Challenge Agent | Isopropyl Alcohol (≥99.5% purity) or Ethanol |
| Display | 7-inch true-color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W × H × D) |
| Weight | 2.3 kg |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE Guidance, GB 2626–2019, GB 19083–2010 |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Data Export Format | Microsoft Excel (.xlsx) |
| Multi-unit Control | Up to 4 units per PC |
| Language Options | English, Japanese, Chinese, French, Spanish, Portuguese |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch full-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Supported Languages | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units simultaneously via single PC |
| Data Export Format | Microsoft Excel |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4, ANSI/ASSP Z88.10 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units simultaneously via single PC |
| Data Export Format | Microsoft Excel |
| Brand | Ko-mei Rikagaku |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 131 |
| Pricing | Upon Request |
| Brand | LGR |
|---|---|
| Origin | USA |
| Model | DLT-100 (Benchtop), RMT-200 (Portable) |
| Detection Principle | Off-Axis Integrated Cavity Output Spectroscopy (Off-Axis ICOS) |
| Measurement Range | 0.3–25 ppm CH₄ |
| Precision | 1 ppb @ 1 Hz (ambient conditions) |
| Response Time | <0.05 s (with external pump), 25 s (internal pump) |
| Accuracy | Better than ±1% of reading |
| Operating Temperature | 0–50 °C |
| Relative Humidity | <98% RH, non-condensing |
| Data Output | RS-232, Analog (0–10 V / 4–20 mA), Ethernet |
| Data Storage | Internal 20 GB HDD + 12.1" color TFT display |
| Power | 115/230 V AC, 50/60 Hz, 80 W (excl. optional external pump) |
| Dimensions (Benchtop) | 25.4 × 96.5 × 35.56 cm |
| Dimensions (Portable) | 22.2 × 48.26 × 60.9 cm |
| Weight | 27 kg |
| Compliance | Designed for field-deployable, unattended operation |
| Brand | LGR |
|---|---|
| Origin | USA |
| Model | FGGA |
| Type | Off-Axis Integrated Cavity Output Spectroscopy (Off-Axis ICOS) Analyzer |
| Detection Targets | CH₄, CO₂, H₂O |
| Repeatability | CH₄ ≤ 1 ppbv, CO₂ ≤ 0.2 ppmv, H₂O ≤ 100 ppmv |
| Response Time | 0.1 s (with external DSVP pump), 25 s (with internal pump) |
| Mirror Reflectivity | >99.999% |
| Accuracy | <1% of reading |
| Measurement Ranges | CH₄: 0.1–10,000 ppmv (standard), down to 0.005 ppmv (optional) |
| CO₂ | 200–20,000 ppmv (standard), up to 20,000 ppmv (optional) |
| H₂O | 7,000–80,000 ppmv (standard), 1,500–80,000 ppmv (optional) |
| Effective Optical Path Length | ~2.5 km (typical, based on 25 cm cavity with 99.999% mirrors) |
| Data Storage | 40 GB internal SSD |
| Display | 12.1" color TFT (desktop only) |
| Sample Temperature Range | 0 °C |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Gas Inlet Fittings | 1/4", 3/8", or 1/2" Swagelok® |
| Power | 115/230 VAC, 50/60 Hz, 90 W (DC conversion supported) |
| Dimensions (Desktop) | 25 × 96 × 35 cm |
| Dimensions (Portable) | 22 × 48 × 61 cm |
| Weight | 30 kg (desktop), ~18 kg (portable) |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-MEK |
| Output Options | 4–20 mA (3-wire or 4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Dual Relay Outputs |
| Communication | Wired, LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF) |
| Remote Operation | Infrared remote control (15 m range, intrinsically safe operation without opening enclosure) |
| Calibration | Auto-zero tracking, multi-point calibration support |
| Certifications | CPA Type Approval (China), Ex d IIC T6 Gb explosion-proof certification, EMC/EMI compliant (GB/T 18268, GB/T 17626 series), Anti-static & reverse-polarity protected |
| Sensor Options | Electrochemical, Catalytic Bead, NDIR, PID, Thermal Conductivity (selectable from Honeywell, Figaro, City Technology, Alphasense, Dynament, Membrapor) |
| Brand | Mingguang Lihua |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SG-1 |
| Weight | 50 g |
| Power Supply | Rechargeable Lithium Battery |
| Operating Modes | Manual & Auto (30 s cycle) |
| Continuous Operation Time | Up to 16 minutes |
| Refill Cartridge | Replaceable top-mounted cartridge containing food-grade propylene glycol and glycerol |
| Illumination | Integrated LED light for low-light visibility |
| Compliance | RoHS-compliant formulation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA PICO ETO |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA PICO MOBILE LDS |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MGA-5 |
| Pricing | Upon Request |
| Measurement Principle | Time-Multiplexed Intermittent Continuous-Wave Quantum Cascade Laser Absorption Spectroscopy (TM-ICW-QCL) |
| Sampling Frequency | 1 Hz |
| Detection Limits (1 s) | CO: 0.4 ppb, CO₂: 0.8 ppm, CH₄: 1 ppb, N₂O: 0.5 ppb, H₂O: 40 ppm |
| Detection Limits (200 s) | CO: 0.07 ppb, CO₂: 0.08 ppm, CH₄: 0.2 ppb, N₂O: 0.1 ppb, H₂O: 6 ppm |
| Measurement Ranges | CO: 0–20 ppm, CO₂: 0–8000 ppm, CH₄: 0–200 ppm, N₂O: 0–20 ppm, H₂O: 0–10 %v/v |
| Maximum Drift (12 h) | CO: 1 ppb, CO₂: 1 ppm, CH₄: 5 ppb, N₂O: 2 ppb, H₂O: 120 ppm |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | < 90 % RH (non-condensing) |
| Pressure Range | 700–1050 mbar |
| Sample Flow Rate | 0.5–1.5 L/min (high-flow option available) |
| Power Supply | 220 VAC, 50 Hz, < 450 W |
| Dimensions (Analyzer) | 48 W × 18 H × 62 D cm |
| Weight (Analyzer) | 20 kg |
| (Cooling Unit) | 11 kg |
| (Vacuum Pump) | 9 kg |
| Safety Certifications | CE-marked per IEC 61010-1:2010, IEC 61326-1:2012, IEC 60825:2019 |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MCY600 |
| Operating Temperature | 5–45 °C |
| Sample Gas Pressure | up to 20 kPa (gauge) |
| Sample Flow Rate | 0.2–1.0 L/min |
| Power Supply | 12–24 VDC |
| Output Signal | 4–20 mA |
| Communication Interface | RS485 (Modbus RTU) |
| Measurement Ranges | 0–5%, 0–10%, 0–21%, 0–50%, 0–90%, 90–100%, 0–100% O₂ (v/v) |
| Linearity Error | ±2% FS |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Cross-Interference Resistance | NH₃, CO, CO₂, CH₄ |
| Corrosive Gas Tolerance | Yes (e.g., H₂S) |
| Sensor Type | Thermal-Magnetic Paramagnetic Detection |
| Vibration Immunity | High |
| Consumable-Free Design | Yes |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom T |
| Pricing | Upon Request |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Method | Wavelength Modulation Spectroscopy (WMS) with Digital Lock-in Amplification |
| Gas Species | H₂O (dew point), O₂, HF, NH₃, CO, CO₂, H₂S |
| Concentration Ranges | 0–1000 ppm (H₂O), 0–25% vol (O₂), 0–10 ppm (HF), 0–100 ppm (NH₃, CO, CO₂), 0–2% vol (CO₂), 0–100 ppm (H₂S) |
| Accuracy | ±3% FS for all listed gases |
| Detection Limits | 0.1 ppm (H₂O, HF, NH₃, CO, CO₂), 0.1% vol (O₂), 0.01 ppm (H₂S), 0.5 ppm (H₂S — alternate spec) |
| Form Factors | Portable, In-situ Online, Ambient-Temperature & High-Temperature Configurations |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | OX-01 |
| Pricing | Available Upon Request |
| Oxygen (O2) Detection Principle | Zirconia Electrochemical Cell |
| O2 Range | 90–100 % vol |
| O2 Resolution | 0.01 % |
| CO2 Detection Principle | NDIR (Non-Dispersive Infrared) |
| CO2 Range | 0–2000 ppm |
| CO2 Resolution | 0.1 ppm |
| CO Detection Principle | Electrochemical Sensor |
| CO Range | 0–50 ppm |
| CO Resolution | 0.1 ppm |
| Cl₂ Detection Principle | Electrochemical Sensor |
| Cl₂ Range | 0–10 ppm |
| Cl₂ Resolution | 0.1 ppm |
| Dew Point Temperature Measurement Principle | Capacitive Hygrometry |
| Dew Point Range | –60 to +20 °C |
| Dew Point Resolution | 0.01 °C |
| Particulate Matter (PM) Detection Principle | Laser Light Scattering |
| PM Range | 0–1 mg/m³ |
| PM Resolution | 0.001 mg/m³ |
| Display | 5.6-inch high-resolution TFT LCD |
| Data Logging | Internal storage with timestamped records |
| Portability | Handheld, battery-operated design for field deployment |
| Brand | PERIC |
|---|---|
| Model | PR-CEMS-100 |
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Measurement Principles | UV Differential Optical Absorption Spectroscopy (UV-DOAS), Non-Dispersive Infrared (NDIR), Electrochemical Sensing |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, O₂, CH₄ (optional) |
| Sample Flow Rate | 60–100 L/min |
| Response Time | ≤30 s |
| Accuracy | ≤±2% FS |
| Zero/ Span Drift | <±2% FS/week |
| S/C Ratio Calculation | Supported |
| Environmental Rating | Marine-grade (salt fog, vibration, acceleration/deceleration) |
| Compliance | MARPOL Annex VI, GB 15097–2016, GD01–2011 |
| Certifications | Recognized by Major Classification Societies (e.g., CCS, DNV, LR, ABS) |
| Output Interfaces | 4–20 mA analog, Modbus TCP/RTU |
| Optional Enclosure | Climate-controlled cabinet with HVAC |
| Key | Brand: Picarro |
|---|---|
| Origin | USA |
| Model | G2308 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Target Gases | Nitrous Oxide (N₂O), Methane (CH₄), Water Vapor (H₂O) |
| N₂O Precision (1σ, 5 min) | <3.5 ppb + 0.008% of reading |
| CH₄ Precision (1σ, 5 min) | <3 ppb + 0.02% of reading |
| H₂O Precision (1σ, 5 min) | <100 ppm |
| Detection Limits | N₂O ≤10 ppb (1-min), CH₄ ≤7 ppb (1-min), H₂O ≤250 ppm (1-min) |
| Sample Flow Rate | ~230 sccm |
| Operating Pressure Range | 300–1000 Torr (40–133 kPa) |
| Temperature Control Stability | ±0.005 °C (cavity) |
| Pressure Control Stability | ±0.0002 atm (cavity) |
| Dimensions (W×H×D) | 43.2 × 17.8 × 44.6 cm |
| Weight | 22.6 kg |
| Power | 100–240 VAC, 47–63 Hz, 110 W (steady-state) |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | PI2114 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Detection Limit | <3 ppb (3σ, 300 s) |
| Accuracy | <1 ppb + 0.1% of reading (1σ, 300 s) |
| Precision (5-min) | <0.5 ppb (1σ) |
| Response Time (10–90% / 90–10%) | <60 s |
| Measurement Range | 0–100 ppm |
| Sample Flow Rate | <1 slm at 760 Torr |
| Operating Temperature | –10 to 45 °C |
| Sample Pressure | 300–1000 Torr (40–133 kPa) |
| Relative Humidity | <99% RH, non-condensing at 40 °C |
| Certified | CE Mark, CDRH |
| Compliance | FDA 21 CFR Part 11, GMP-ready |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PRI-5231f |
| Power Input | 110–230 V AC |
| Weight | 1.86 kg |
| Sampling Flow Rate | ~180 mL/min |
| Operating Temperature | −10 to 45 °C |
| Relative Humidity Limit | <99% RH (non-condensing) |
| Data Output | Wi-Fi, USB, RS-232 |
| Power Consumption | 50 W (steady-state), 90 W (warm-up) |
| CO₂ Precision (1 s) | 0.2 ppm |
| N₂O Precision (1 s) | 0.2 ppb |
| H₂O Precision (1 s) | 50 ppm |
| CO₂ Precision (5 s) | 0.12 ppm |
| N₂O Precision (5 s) | 0.12 ppb |
| H₂O Precision (5 s) | 40 ppm |
| CO₂ Range | 0–3500 ppm |
| N₂O Range | 0–500 ppb |
| H₂O Range | 0–3 %v/v |
| 24-h Drift (CO₂) | 0.3 ppm |
| 24-h Drift (N₂O) | 0.3 ppb |
| Sampling Frequency | 1 or 2 Hz |
| Measurement Principle | Mid-Infrared Laser Absorption Spectroscopy (MIRLAS) |
| Brand | PRI-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PRI-560 |
| Weight | < 2 kg |
| Power Input | 12–24 V DC, max. 700 mA |
| Detection Principle | Luminol-based chemiluminescence |
| Sensitivity | < 1 ppb (NO₂) |
| Accuracy | ±2 % of reading |
| Linear Range | 2 ppb – 500 ppb (NO₂) |
| Sampling Rate | 5 Hz |
| Reagent Consumption | < 100 µL/min |
| Operating Temperature | 0–40 °C |
| GPS Module | Integrated |
| Environmental Sensors | Onboard temperature, relative humidity, and barometric pressure |
| Data Storage | Internal non-volatile memory |
| Output Interface | USB for data download |
| Auto-calibration | Supported via ground control unit with certified standard gases |
| Dimensions | Ø210 mm × H200 mm |
| Brand | PyroScience |
|---|---|
| Origin | Germany |
| Model | RF-O2 Environmental |
| Measurement Principle | Fluorescence Quenching of Oxygen-Sensitive Dyes |
| Optical Sensor Technology | REDFLASH (Rapid Excitation and Detection of Fluorescence) |
| Channel Options | 1-, 2-, or 4-Channel Configurations |
| Power Supply | USB 5V DC (20 mA) |
| Dimensions | 78 × 120 × 24 mm |
| Weight | 290 g |
| Operating Temperature | 0–50 °C, non-condensing |
| Integrated Sensors | Barometric pressure (300–1100 mbar, ±3 mbar accuracy), Relative humidity (0–100 %RH, ±0.2 %RH), Pt100 temperature input |
| Sampling Rate | 10–20 Hz per channel |
| Analog Output | 0–2.5 VDC |
| Interface | USB 2.0, UART serial |
| Software Suite | Pyro Workbench (device control & calibration), Pyro Data Inspector (respiration rate calculation, drift correction, TOU analysis) |
| Oxygen Ranges | Full-scale: 0–100 %O₂ (gas phase), 0–44 mg/L (dissolved O₂) |
| Trace | 0–21 %O₂ (gas), 0–9 mg/L (dissolved) |
| LOD | 0.02 %O₂ / 0.01 mg/L (full-scale), 0.005 %O₂ / 0.002 mg/L (trace) |
| Temperature Compensation | Real-time, integrated |
| Sensor Compatibility | Contact-type (probes, needles, bare fiber, solvent-resistant, insertion) and non-contact (optode films, flow cells, respirometry chambers) |
| Compliance | Designed for GLP-aligned workflows |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | XHCYQ2000 |
| Flow Rate | 16.67 L/min (±0.3 L/min) |
| Flow RSD | ≤1.5% |
| Flow Accuracy | ≤1.5% |
| Standardized Volume Error | ±3% |
| Clock Drift (6h, powered) | ±10 s |
| Clock Drift (6h, after 5 power interruptions) | ±2 min |
| Barometric Pressure Accuracy | ≤1 kPa |
| Temperature Accuracy | ±2 ℃ |
| Reference Method Correlation | Slope = 1 ± 0.1, Intercept = 0 ± 0.5 µg/m³, r ≥ 0.97 |
| MTBF | ≥800 h |
| Dimensions (H×W×D) | 46 cm × 66 cm × 35 cm (excl. pump enclosure) |
| Weight | 25 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NOA-7000 / CGT-7000 / SOA-7000 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±0.5% of Full Scale |
| Weight | ~14.5–15 kg |
| Brand | SRI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TO-14 Special GC |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SRRG-1 |
| Pricing | Available Upon Request |
| Respiratory Rate Range | 2–120 RPM |
| Respiratory Rate Accuracy | ±0.2% of set value |
| CO₂ Calibration Gas | 5% v/v CO₂ in balance air (custom gas mixtures available) |
| Inlet/Outlet Interface | Pneumatic push-to-connect fittings (adapters for multiple tubing diameters included) |