Pairui Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelPR-MeOH-1000
PriceUpon Request
MeasurandMethanol (0–1000 ppm), Formaldehyde (0–1000 ppm)
Response Time≤30 s (each)
Accuracy±5% FS (each)
Measurement PrincipleUV-DOAS (Formaldehyde, hot/wet sampling), NDIR (Methanol, chilled/dry sampling)
Operating Temperature−10 to 50 °C
Operating Humidity0–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelCustom Model 8
QuotationUpon Request
Response Time≤60 s
Measurement PrincipleUV Differential Optical Absorption Spectroscopy (UV-DOAS) with Hot-Wet Sampling
Detection TargetMonoethanolamine (MEA), Diethanolamine (DEA), and related alkanolamines
Range0–20 ppm
LOD200 ppb
Accuracy≤±5% FS
Sample Flow Rate≥2 L/min
Optical Path Length≥7 m
Operating Temperature−5 to 40 °C
Operating Humidity15–85% RH
PreconditioningHeated Wet Sampling + Multi-Stage Filtration
ComplianceDesigned for marine GLP-aligned operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelCustomized 3
PricingAvailable Upon Request
Measurement SpeciesH₂, O₂
Dimensions (L×W×H)≤1100×550×2100 mm (including nozzles and mounting brackets)
H₂ Range0–5% vol
Low-range H₂0–0.5% vol
O₂ Range0–2.5% vol / 0–25% vol (switchable)
Low-range O₂0–1% vol
H₂ Accuracy±2% FS
O₂ Accuracy±1% FS (for 0–2.5% / 0–25% ranges), ±2% FS (for 0–1% range)
Measurement PrinciplesTunable Diode Laser Absorption Spectroscopy (TDLAS) for O₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelPR-NH3-1000
PricingUpon Request
Measured GasesNH₃, NO, NO₂, N₂O
NH₃ Range0–2000 ppm
NO/NO₂ Range0–2000 ppm / 0–200 ppm
N₂O Range0–2000 ppm
Response Time≤30 s
Accuracy≤±5% FS
Measurement PrinciplesUV-DOAS (for NH₃, NO, NO₂), NDIR (for N₂O), Hot-Wet & Cold-Dry Sample Conditioning
Operating Temperature−10 to 50 °C
Operating Humidity0–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelSLAS-01
Measurement PrincipleTDLAS
Detectable GasesO₂, CO, CO₂, CH₄, C₂H₂, H₂S, NH₃, HCl, HF
Detection LimitsO₂: 0.01% vol
CO1 µmol/mol
CO₂0.01% vol
CH₄0.01% vol
C₂H₂0.01% vol
H₂S1 µmol/mol
Full-Scale RangesO₂/CO/CO₂/CH₄: 0–99.99% vol
C₂H₂/H₂S0–10% vol
Linearity Error≤ ±1% FS
Repeatability & Drift≤ ±1% FS per 6 months
Optical Path Length≤20 m
Sample Temperature≤800 °C
Sample Pressure±5 kPa
Ambient Temperature−20 to +60 °C
Ambient Humidity≤90% RH
Power SupplyDC 24 V
Relay Outputs3 × (24 V / 1 A)
Analog Outputs2 × 4–20 mA (max. load 750 Ω)
Digital InterfaceRS485, Modbus RTU protocol
DisplayMagnet-controlled graphical interface
Enclosure RatingIP66
Explosion ProtectionEx d IIC T6