Pairui Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelCustom 9
PricingUpon Request
Detection PrincipleLaser Raman Spectroscopy
Target AnalytesMonoethanolamine (MEA), Diethanolamine (DEA)
Concentration Range0–55% (w/w)
Accuracy≤ ±1% FS
Response Time≤ 30 s
Operating Temperature−10 to 50 °C
Operating Humidity15–85% RH
Probe ConfigurationIn-situ or Extractive
System ArchitectureModular (Separated Spectrometer Unit & Immersion Probe)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelGNF-TR-DP
Sensor PrincipleUltra-Thin Aluminum Oxide Capacitive
Measurement Range–100 °C to +20 °C (Td)
Accuracy±2 °C @ +20 °C to –60 °C Td
Repeatability±0.5 °C
Stability±1% F.S. / 7 days
Response Time (63% / 90%)5 s / 10 s (–60 °C → –20 °C Td)
Explosion ProtectionEx db IIC T6 Gb (ATEX-compliant)
Ingress ProtectionIP66
Power Supply24 V DC
Communication InterfaceTTL-level Serial Port
Analog Output4–20 mA (hardware-ready, software-configurable)
Mechanical InterfaceM20×1.5 thread (display unit)
Operating Ambient Temperature–10 °C to +50 °C
Relative Humidity<90% RH (non-condensing)
Sample PressureAtmospheric ±10% (vented to ambient)
Sample Flow Rate3–5 L/min
Sensor Lifetime>2 years (normal operation)
Instrument Lifetime>5 years (normal operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
ModelCustom 2
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelPR-GLRSA
QuotationUpon Request
Detection Channels2 (simultaneous)
Target GasesH₂, CO, C₃H₈, C₃H₆
Concentration RangesH₂: 0–50% vol, CO: 0–10% vol, C₃H₈: 0–50% vol, C₃H₆: 0–80% vol
Accuracy≤ ±3% FS
Response Time≤ 30 s
Explosion ProtectionEx db ec ib pzc II C T3 Gc (Positive-Pressure Purged & Pressurized)
Operating Temperature5–40 °C
Power SupplyAC 220 V / 50 Hz, ≤ 800 W (host only)
Purge GasClean, oil-free, dry, particle-free compressed air, 0.4–0.8 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelRGA100 / RGA200
PrincipleElectron Ionization (EI) Quadrupole Mass Spectrometry
Mass Range0–200 amu
Minimum Sampling Interval0.05 amu
Mass Resolution (FWHM)< 0.5 amu
Ion SourceEI Source with Yttria-Coated Iridium Filament (Filament Current: 0–4 A)
DetectorElectron Multiplier (Gain > 10³)
Scan Speed5–1000 ms per data point
ComplianceDesigned for UHV and HV vacuum environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelPR-RM
Instrument TypeOnline Raman Spectrometer
Gas SpeciesBenzene, Nitrogen, Hydrogen, Carbon Dioxide, Carbon Monoxide, Carbonyl Sulfide, Hydrogen Sulfide, Oxygen, Methane
Range0–100 %vol
Detection Limit≤50–100 ppm (gas-dependent)
Accuracy≤2 %FS
Measurement Cycle1–30 s (adjustable)
Sampling MethodPump-aspirated with integrated pre-treatment
Environmental RobustnessRated for high-pressure, high-temperature, high-humidity, high-dust, and hazardous-area operation
MaintenanceConsumable-free design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
RegionDomestic (China)
ModelPR-LR
PricingUpon Request
Gas Detection RangeN₂, O₂, H₂, CH₄, CO, CO₂, C₂H₆, C₂H₄, C₂H₂, C₃H₈, C₃H₆, C₄H₁₀, NO, NO₂, SO₂, H₂S
Accuracy≤±1% FS for components >1% full scale
Resolution≤0.01% (for >1% FS)
Analysis Time10–30 s (adjustable)
Laser Wavelength532 nm
Laser Linewidth≤0.1 nm
Spectral Range0–4200 cm⁻¹
Spectral Resolution5 cm⁻¹
Power Supply220 VAC, 50 Hz
Max. Power Consumption≤300 W
Operating Temperature10–35 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelPR-LM
TypePortable / Handheld Raman Spectrometer
OriginHebei, China
ManufacturerPERIC Instrument Co., Ltd.
Measurement Range0–100% (v/v)
Detection Limit1 µmol/mol
Accuracy±0.1% (full scale)
Analysis Time1–300 s (user-configurable)
Sample InletIntegrated diaphragm pump
Dimensions (L×W×H)557 × 420 × 330 mm
Weight<23 kg
Target GasesH₂, N₂, O₂, CO, CO₂, CH₄, NH₃, H₂O, H₂S, C₂H₂, C₂H₄, C₂H₆, C₃H₆, and other hydrocarbons and inorganic gases
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOEM/ODM Producer
Country of OriginChina
ModelCustomized-6
PricingAvailable Upon Request