BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelPR-MeOH-1000
PriceUpon Request
MeasurandMethanol (0–1000 ppm), Formaldehyde (0–1000 ppm)
Response Time≤30 s (each)
Accuracy±5% FS (each)
Measurement PrincipleUV-DOAS (Formaldehyde, hot/wet sampling), NDIR (Methanol, chilled/dry sampling)
Operating Temperature−10 to 50 °C
Operating Humidity0–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelCustom Model 8
QuotationUpon Request
Response Time≤60 s
Measurement PrincipleUV Differential Optical Absorption Spectroscopy (UV-DOAS) with Hot-Wet Sampling
Detection TargetMonoethanolamine (MEA), Diethanolamine (DEA), and related alkanolamines
Range0–20 ppm
LOD200 ppb
Accuracy≤±5% FS
Sample Flow Rate≥2 L/min
Optical Path Length≥7 m
Operating Temperature−5 to 40 °C
Operating Humidity15–85% RH
PreconditioningHeated Wet Sampling + Multi-Stage Filtration
ComplianceDesigned for marine GLP-aligned operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelDQF
Measurement PrincipleThermal Conductivity
Range0–1% H₂ (v/v)
Response Time≤2.5 min
Accuracy±5% FS
Alarm Threshold>0.75% H₂
Power SupplyAC 220 V
Power Consumption≤10 W
Enclosure RatingEx d II CT6
Output Signals1–5 V DC & 4–20 mA
DisplayDigital Panel Meter (H₂ %)
Alarm OutputAudible/Visual + Relay Contacts
ComplianceGB/T 3836.1–2021 (Explosion-Proof), JJG 915–2008 (Calibration Standard for Thermal Conductivity Gas Analyzers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelCustomized 3
PricingAvailable Upon Request
Measurement SpeciesH₂, O₂
Dimensions (L×W×H)≤1100×550×2100 mm (including nozzles and mounting brackets)
H₂ Range0–5% vol
Low-range H₂0–0.5% vol
O₂ Range0–2.5% vol / 0–25% vol (switchable)
Low-range O₂0–1% vol
H₂ Accuracy±2% FS
O₂ Accuracy±1% FS (for 0–2.5% / 0–25% ranges), ±2% FS (for 0–1% range)
Measurement PrinciplesTunable Diode Laser Absorption Spectroscopy (TDLAS) for O₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelPR-NH3-1000
PricingUpon Request
Measured GasesNH₃, NO, NO₂, N₂O
NH₃ Range0–2000 ppm
NO/NO₂ Range0–2000 ppm / 0–200 ppm
N₂O Range0–2000 ppm
Response Time≤30 s
Accuracy≤±5% FS
Measurement PrinciplesUV-DOAS (for NH₃, NO, NO₂), NDIR (for N₂O), Hot-Wet & Cold-Dry Sample Conditioning
Operating Temperature−10 to 50 °C
Operating Humidity0–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelCJJC-3
QuotationUpon Request
Communication4G (TCP/UDP/HTTP/MQTT) + RS485
Power SupplyAC 85–265 V / DC 110–370 V
Operating Temperature−30 to +70 °C
Electrical Parameters MeasuredPhase & total voltage, current, active/reactive power, energy, grid frequency
Accuracy ClassActive Energy Class 1
Voltage Input RangeAC 7–265 V (direct)
Current Input Range0–5 A (direct)
MountingDIN rail
Dimensions (L×W×H)92 × 76 × 59 mm
Data Upload ProtocolHJ 212 (customizable)
Special FunctionsPower-on/off alarm, cover-open detection, internal temperature monitoring, built-in antenna & terminal block
Enclosure DesignTamper-resistant, fully integrated wiring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelPG-TR-O2
PriceUpon Request
Detection PrincipleIon Current
Measurement Range0–1000 μmol/mol (ppm)
Accuracy±5% FS
Resolution1 μmol/mol
Repeatability≤1.5% at 50% FS
Response Time (T90)<20 s
Output Signals4–20 mA (2-wire), RS485 (Modbus RTU)
Power SupplyDC 24 V
ComplianceGB/T 3369.1-2008, GB/T 11606-2007, GB 12358-2006, GB/T 19582.2-2008, GB/T 2828.1, GB/T 700-2006, GB/T 191-2008
Expected Service Life≥5 years (full unit, including sensor)
Sensor Storage StabilityNo lifetime degradation when stored unpowered and exposed to ambient air
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelGNF-TR-H2
Detection PrincipleThermal Conductivity (TCD)
Measurement Range0–5.00% H₂ (customizable)
Resolution0.01% H₂
Accuracy≤±2% FS
Repeatability≤±1% FS
Zero Drift≤±2% FS/24h
Span Drift≤±2% FS/24h
Response Time (T90)≤30 s
Sample Pressure≤0.2 MPa
Sample Flow Rate500 ±10 mL/min
Sample Temperature0–50 °C
Ambient Operating Temperature0–50 °C
Storage Temperature0–50 °C
Relative Humidity20–80% RH (non-condensing)
Power SupplyDC 24 V
Power Consumption<5 W
Output Signals4–20 mA DC (load ≤250 Ω) & RS485 Modbus RTU
Explosion ProtectionEx db IIC T6 Gb
Enclosure RatingIP65
CompensationIntegrated temperature & humidity compensation
ComplianceATEX, IECEx, GB 3836.1/3836.4 compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelCustom Software Solution
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOEM Manufacturer
Origin CategoryDomestic (China)
ModelGNF-TR-O2-1
Sensor TypeElectrochemical
Measurement Range0–10 / 0–100 / 0–1000 ppm O₂
Accuracy±2% FS
Repeatability±1% FS
Response Time (T₉₀)≤30 s
Stability±1% FS / 7 days
Explosion Protection RatingEx db IIC T6 Gb (ATEX/IECEx equivalent)
Ingress ProtectionIP66
Output Signal4–20 mA (3-wire), RS485 Modbus RTU
Power Supply24 VDC
Operating Temperature–10 to +50 °C
Relative Humidity<90% RH (non-condensing)
Sample PressureAmbient ±10% (outlet vented to atmosphere)
Sample Flow Rate1.0–1.5 L/min
Gas Inlet/Outlet1/4″ NPT female, with standard Φ6 stainless steel compression fittings
Sensor Lifetime>2 years (typical operating conditions)
Instrument Service Life>5 years (normal use)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelDYF
Measurement PrincipleCatalytic Combustion (Pd-Catalyzed Exothermic Reaction)
Measurement Range0–1% O₂
Resolution0.01% O₂
Response Time (T₉₀)≤2.5 min
Accuracy±5% FS
Alarm Threshold>0.75% O₂
Output Signals1–5 V DC, 4–20 mA
DisplayLED Digital Panel
Power SupplyAC 220 V ±10%, 50 Hz ±2.5 Hz
Power Consumption≤10 W
Environmental Operating Range0–40 °C, <95% RH
Enclosure RatingEx d II CT6 (IEC 60079-1 & IEC 60079-2 compliant)
ComplianceGB/T 11606–2007, JB/T 8279–1999, GB 3836.1–2010, GB 3836.2–2010
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelSLAS-01
Measurement PrincipleTDLAS
Detectable GasesO₂, CO, CO₂, CH₄, C₂H₂, H₂S, NH₃, HCl, HF
Detection LimitsO₂: 0.01% vol
CO1 µmol/mol
CO₂0.01% vol
CH₄0.01% vol
C₂H₂0.01% vol
H₂S1 µmol/mol
Full-Scale RangesO₂/CO/CO₂/CH₄: 0–99.99% vol
C₂H₂/H₂S0–10% vol
Linearity Error≤ ±1% FS
Repeatability & Drift≤ ±1% FS per 6 months
Optical Path Length≤20 m
Sample Temperature≤800 °C
Sample Pressure±5 kPa
Ambient Temperature−20 to +60 °C
Ambient Humidity≤90% RH
Power SupplyDC 24 V
Relay Outputs3 × (24 V / 1 A)
Analog Outputs2 × 4–20 mA (max. load 750 Ω)
Digital InterfaceRS485, Modbus RTU protocol
DisplayMagnet-controlled graphical interface
Enclosure RatingIP66
Explosion ProtectionEx d IIC T6
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
OriginHebei, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelGNF-TR-O2
PriceUpon Request
Measurement PrincipleFuel Cell Electrochemical Sensor
Measurement Range0–5.00% O₂ (customizable)
Resolution0.01% O₂
Accuracy≤ ±1% FS
Repeatability≤ ±1% FS
Response Time (T90)≤ 30 s
Sample Pressure≤ 0.2 MPa
Sample Flow Rate500 ± 10 mL/min
Sample Temperature0–50 °C
Ambient Temperature0–50 °C
Storage Temperature0–50 °C
Relative Humidity20–80% RH (non-condensing)
Power Supply24 V DC ±10%
Power Consumption< 1 W
Output Signal4–20 mA DC (load ≤ 250 Ω) or RS485 digital interface
Enclosure MaterialStainless Steel
Dimensions68 × 68 × 110 mm (L × W × H)
Process Connection1/4" NPT internal thread
Explosion ProtectionEx d II C T6 Gb
Temperature CompensationIntegrated
ComplianceATEX Directive 2014/34/EU, IEC 60079-1, GB 3836.1 & GB 3836.2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPERIC
ModelPG-TR-H2
Measurement GasHydrogen (H₂)
Output Signals4–20 mA, RS485, 0–3 V DC
Power Supply12–24 V DC
Measurement Ranges0–2000 µmol/mol or 0–5000 µmol/mol (selectable)
Response Time≤60 s
Resolution1 µmol/mol
Accuracy±5% FS
Enclosure RatingExplosion-Proof (certified per GB 12358-2006)
ConstructionFull 316L Stainless Steel
Sampling MethodIn-situ diffusion through process pipeline wall
ComplianceGB/T 3369.1-2008, GB/T 19582.2-2008 (Modbus RTU), GB 12358-2006, GB/T 11606-2007
Show next