- All
- Favorite
- Popular
- Most rated
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Custom 9 |
| Pricing | Upon Request |
| Detection Principle | Laser Raman Spectroscopy |
| Target Analytes | Monoethanolamine (MEA), Diethanolamine (DEA) |
| Concentration Range | 0–55% (w/w) |
| Accuracy | ≤ ±1% FS |
| Response Time | ≤ 30 s |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 15–85% RH |
| Probe Configuration | In-situ or Extractive |
| System Architecture | Modular (Separated Spectrometer Unit & Immersion Probe) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Customized 4 |
| Pricing | Upon Request |
| Brand | PERIC |
|---|---|
| Model | GNF-TR-DP |
| Sensor Principle | Ultra-Thin Aluminum Oxide Capacitive |
| Measurement Range | –100 °C to +20 °C (Td) |
| Accuracy | ±2 °C @ +20 °C to –60 °C Td |
| Repeatability | ±0.5 °C |
| Stability | ±1% F.S. / 7 days |
| Response Time (63% / 90%) | 5 s / 10 s (–60 °C → –20 °C Td) |
| Explosion Protection | Ex db IIC T6 Gb (ATEX-compliant) |
| Ingress Protection | IP66 |
| Power Supply | 24 V DC |
| Communication Interface | TTL-level Serial Port |
| Analog Output | 4–20 mA (hardware-ready, software-configurable) |
| Mechanical Interface | M20×1.5 thread (display unit) |
| Operating Ambient Temperature | –10 °C to +50 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Sample Pressure | Atmospheric ±10% (vented to ambient) |
| Sample Flow Rate | 3–5 L/min |
| Sensor Lifetime | >2 years (normal operation) |
| Instrument Lifetime | >5 years (normal operation) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | G-WA10 |
| Pricing | Upon Request |
| Detection Principles | Electrochemical, Infrared (IR), Catalytic Combustion, Thermal Cracking + IR |
| Supported Gases | >30 toxic, flammable, and corrosive gases including NH₃, NF₃, SiH₄, AsH₃, B₂H₆, PH₃, H₂S, Cl₂, HF, HCl, HBr, SO₂, O₃, CO, NO, O₂, CH₄, C₂H₂, C₂H₄, C₃H₆, H₂, D₂, C₄F₆, CH₃F, CH₂F₂, COS, IPA, TEOS, GeH₄, ClO₂, CH₃ClO₂S |
| Sampling | Integrated diaphragm pump with flow & pressure monitoring and auto-adaptive regulation |
| Sensor Architecture | Modular, hot-swap intelligent sensors with offline calibration capability |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PR-MeOH-1000 |
| Price | Upon Request |
| Measurand | Methanol (0–1000 ppm), Formaldehyde (0–1000 ppm) |
| Response Time | ≤30 s (each) |
| Accuracy | ±5% FS (each) |
| Measurement Principle | UV-DOAS (Formaldehyde, hot/wet sampling), NDIR (Methanol, chilled/dry sampling) |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Custom Model 8 |
| Quotation | Upon Request |
| Response Time | ≤60 s |
| Measurement Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) with Hot-Wet Sampling |
| Detection Target | Monoethanolamine (MEA), Diethanolamine (DEA), and related alkanolamines |
| Range | 0–20 ppm |
| LOD | 200 ppb |
| Accuracy | ≤±5% FS |
| Sample Flow Rate | ≥2 L/min |
| Optical Path Length | ≥7 m |
| Operating Temperature | −5 to 40 °C |
| Operating Humidity | 15–85% RH |
| Preconditioning | Heated Wet Sampling + Multi-Stage Filtration |
| Compliance | Designed for marine GLP-aligned operation |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Custom 2 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Model | EO-VD |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Target | Total Volatile Organic Compounds (TVOC), including benzene, aliphatic hydrocarbons, and alkanes |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Protection Rating | IP66 |
| Explosion Protection | Ex d IIC T6 Gb |
| Communication Interface | 4G LTE + Ethernet (RJ45) |
| Alarm Output | Visual (LED strobe) + Audible (≥85 dB at 1 m) |
| Data Protocol | HJ 212–2017 (China EPA Standard) |
| Operating Temperature | −10 °C to +55 °C |
| Relative Humidity | ≤93 % RH (non-condensing at 25 °C) |
| Atmospheric Pressure Range | 86–106 kPa |
| Response Time (T90) | ≤20 s |
| Accuracy | ±10 % of Full Scale (FS) |
| Display | High-resolution color LCD (≥3.5″, 320×240 pixels) |
| Sensor Configuration | Triple-sensor simultaneous monitoring (customizable VOC selectivity) |
| Calibration Gas | Isobutylene (default), traceable to NIST or equivalent national standards |
| Typical Measurement Ranges | 0–20, 0–50, 0–200, 0–2000 μmol/mol or 0–50, 0–125 mg/m³ (selectable) |
| Display Resolution | 0.1 or 1 μmol/mol |
| Brand | Peric |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Customized Sub-Metering Electricity Monitoring & Regulatory Platform |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom10 |
| Pricing | Upon Request |
| Gas Measurement Range | NH₃ (0–10,000 ppm), NO (0–3,000 ppm), NO₂ (0–3,000 ppm), N₂O (0–1,000 ppm), CH₃OH (0–2,000 ppm), CH₂O (0–1,000 ppm), CH₄ (0–30,000 ppm), O₂ (0–24% vol), CO (0–2,000 ppm), CO₂ (0–14% vol), SO₂ (0–1,000 ppm) |
| Accuracy | ≤ ±2% FS for all listed gases |
| Detection Technologies | NDIR, UV-DOAS, TDLAS |
| Application Scope | Dual-fuel diesel, LNG, methanol, and ammonia-fueled marine engines |
| Compliance Support | ASTM D6595, ISO 8178-4, IMO MARPOL Annex VI Tier III test protocols |
| Brand | PERIC |
|---|---|
| Model | GAP-O3 |
| Measurement Principle | UV Absorption (254 nm) |
| Detection Range | 0–1000 nmol/mol |
| Detection Limit | ≤1 nmol/mol |
| Accuracy | ±3% FS |
| Repeatability | ≤1% |
| Response Time (T90) | ≤20 s |
| Zero Drift (4 h) | ±2 nmol/mol |
| Span Drift (4 h) | ±4 nmol/mol |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 5-inch capacitive touchscreen |
| Power Supply | DC 12 V (with internal rechargeable Li-ion battery) |
| Compliance | Designed for continuous ambient and industrial process monitoring per ISO 13964, ASTM D5012, and EPA Reference Method EQOA-01 |
| Brand | PERIC |
|---|---|
| Model | DQF |
| Measurement Principle | Thermal Conductivity |
| Range | 0–1% H₂ (v/v) |
| Response Time | ≤2.5 min |
| Accuracy | ±5% FS |
| Alarm Threshold | >0.75% H₂ |
| Power Supply | AC 220 V |
| Power Consumption | ≤10 W |
| Enclosure Rating | Ex d II CT6 |
| Output Signals | 1–5 V DC & 4–20 mA |
| Display | Digital Panel Meter (H₂ %) |
| Alarm Output | Audible/Visual + Relay Contacts |
| Compliance | GB/T 3836.1–2021 (Explosion-Proof), JJG 915–2008 (Calibration Standard for Thermal Conductivity Gas Analyzers) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Customized 3 |
| Pricing | Available Upon Request |
| Measurement Species | H₂, O₂ |
| Dimensions (L×W×H) | ≤1100×550×2100 mm (including nozzles and mounting brackets) |
| H₂ Range | 0–5% vol |
| Low-range H₂ | 0–0.5% vol |
| O₂ Range | 0–2.5% vol / 0–25% vol (switchable) |
| Low-range O₂ | 0–1% vol |
| H₂ Accuracy | ±2% FS |
| O₂ Accuracy | ±1% FS (for 0–2.5% / 0–25% ranges), ±2% FS (for 0–1% range) |
| Measurement Principles | Tunable Diode Laser Absorption Spectroscopy (TDLAS) for O₂ |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Customized Environmental Protection Concierge Service Integrated Platform |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Model | EMO-HJV |
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Power Supply | AC 220 V ±10%, with built-in rechargeable battery supporting ≥6 hours operation during power outage |
| Sampling Method | Active pump-driven aspiration with integrated hydrophobic dust/water filter |
| Communication Interfaces | 4G LTE (Cat 1), Ethernet (RJ45), LoRaWAN (optional), RS485 (Modbus RTU) |
| Local Storage | MicroSD card slot (up to 32 GB) |
| Data Upload Protocol | MQTT/HTTP over TLS 1.2 |
| Remote Capabilities | OTA firmware update, remote zero/span calibration, drift compensation algorithm |
| Data Integrity | 断点续传 (Resume-on-Interruption) with local queue buffering |
| Expandability | Optional meteorological module (wind speed/direction, temperature, humidity, pressure, rainfall) |
| Compliance | Designed per IEC 61326-1 (EMC), EN 50270 (gas detection equipment), and aligned with technical requirements of China’s HJ 653–2013 and HJ 93–2013 for ambient air monitoring stations |
| Detection Parameters & Ranges | PM₂.₅ (0–1000 µg/m³, resolution: 1 µg/m³), PM₁₀ (0–1000 µg/m³, resolution: 1 µg/m³), CO (0–12.5 µmol/mol, resolution: 0.01 µmol/mol), SO₂ (0–1000 nmol/mol, resolution: 1 nmol/mol), NO₂ (0–1000 nmol/mol, resolution: 1 nmol/mol), O₃ (0–1000 nmol/mol, resolution: 1 nmol/mol), VOCs (0–50 µmol/mol, resolution: 1 nmol/mol) |
| Sensor Technologies | Optical scattering (PM), electrochemical (CO, SO₂, NO₂, O₃), photoionization detection (PID) for VOCs, NDIR for CO₂ (optional) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PR-GLRSA |
| Quotation | Upon Request |
| Detection Channels | 2 (simultaneous) |
| Target Gases | H₂, CO, C₃H₈, C₃H₆ |
| Concentration Ranges | H₂: 0–50% vol, CO: 0–10% vol, C₃H₈: 0–50% vol, C₃H₆: 0–80% vol |
| Accuracy | ≤ ±3% FS |
| Response Time | ≤ 30 s |
| Explosion Protection | Ex db ec ib pzc II C T3 Gc (Positive-Pressure Purged & Pressurized) |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V / 50 Hz, ≤ 800 W (host only) |
| Purge Gas | Clean, oil-free, dry, particle-free compressed air, 0.4–0.8 MPa |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Custom Model 11 |
| Pricing | Upon Request |
| Measurement Principle | Infrared Light Scattering |
| Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Adjustable Alarm Threshold | 0.9–2.5 mg/L |
| Communication Interface | RS485 |
| Power Supply | 24 VDC |
| Brand | PERIC |
|---|---|
| Model | PR-CEMS-100 |
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Measurement Principles | UV Differential Optical Absorption Spectroscopy (UV-DOAS), Non-Dispersive Infrared (NDIR), Electrochemical Sensing |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, O₂, CH₄ (optional) |
| Sample Flow Rate | 60–100 L/min |
| Response Time | ≤30 s |
| Accuracy | ≤±2% FS |
| Zero/ Span Drift | <±2% FS/week |
| S/C Ratio Calculation | Supported |
| Environmental Rating | Marine-grade (salt fog, vibration, acceleration/deceleration) |
| Compliance | MARPOL Annex VI, GB 15097–2016, GD01–2011 |
| Certifications | Recognized by Major Classification Societies (e.g., CCS, DNV, LR, ABS) |
| Output Interfaces | 4–20 mA analog, Modbus TCP/RTU |
| Optional Enclosure | Climate-controlled cabinet with HVAC |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Custom Version |
| Pricing | Upon Request |
| Detection Gases | Hydrogen, Combustible Gases (e.g., CH₄), Oxygen, Ammonia |
| Measurement Ranges | 0–100% LEL (H₂ & combustibles), 0–25% O₂, 0–100 ppm NH₃ |
| Accuracy | ≤±3% FS (H₂ & combustibles), ≤±2% FS (O₂), ≤±5% FS (NH₃) |
| T90 Response Time | ≤30 s (H₂), ≤60 s (combustibles, O₂, NH₃) |
| Certification | CCC (China Compulsory Certification) |
| Design | Explosion-Proof (Ex d IIB T6 Gb), Modular Controller Architecture, Integrated Sampling & Pre-treatment Compatibility |
| Environmental Resistance | Vibration-resistant, Salt Mist Resistant |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Customized FTIR-Based Remote Toxic Gas Detection and Alarm System |
| Pricing | Upon Request |
| Detector Type | Cooled HgCdTe (MCT) |
| Maximum Detection Range | 4.28 km |
| Spectral Resolution | 1.6 cm⁻¹ |
| Spectral Acquisition Rate | 20 Hz |
| Operating Temperature Range | −40°C to +65°C |
| Enclosure Rating | IP66 |
| Dimensions (L×W×H) | 370 × 320 × 500 mm |
| Weight | 28 kg |
| Explosion-Proof Certification | Certified |
| Detectable Gases | ≥10 toxic/hazardous gases (e.g., SF₆, NH₃, HCl, HF, CO, CH₄, VOCs) |
| Minimum Detectable Column Density | 32 mg/m² for SF₆ (at 5°C target-background thermal contrast) |
| Alarm Response Time | ≤1 s |
| Gas Identification Capability | Multi-component analysis under spectral overlap conditions |
| Imaging Mode | Pseudocolor IR gas cloud overlay with visible-light co-registration |
| Calibration | Automated blackbody reference calibration |
| Deployment Options | Fixed-mount or vehicle-mounted |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RGA100 / RGA200 |
| Principle | Electron Ionization (EI) Quadrupole Mass Spectrometry |
| Mass Range | 0–200 amu |
| Minimum Sampling Interval | 0.05 amu |
| Mass Resolution (FWHM) | < 0.5 amu |
| Ion Source | EI Source with Yttria-Coated Iridium Filament (Filament Current: 0–4 A) |
| Detector | Electron Multiplier (Gain > 10³) |
| Scan Speed | 5–1000 ms per data point |
| Compliance | Designed for UHV and HV vacuum environments |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PR-NH3-1000 |
| Pricing | Upon Request |
| Measured Gases | NH₃, NO, NO₂, N₂O |
| NH₃ Range | 0–2000 ppm |
| NO/NO₂ Range | 0–2000 ppm / 0–200 ppm |
| N₂O Range | 0–2000 ppm |
| Response Time | ≤30 s |
| Accuracy | ≤±5% FS |
| Measurement Principles | UV-DOAS (for NH₃, NO, NO₂), NDIR (for N₂O), Hot-Wet & Cold-Dry Sample Conditioning |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CJJC-3 |
| Quotation | Upon Request |
| Communication | 4G (TCP/UDP/HTTP/MQTT) + RS485 |
| Power Supply | AC 85–265 V / DC 110–370 V |
| Operating Temperature | −30 to +70 °C |
| Electrical Parameters Measured | Phase & total voltage, current, active/reactive power, energy, grid frequency |
| Accuracy Class | Active Energy Class 1 |
| Voltage Input Range | AC 7–265 V (direct) |
| Current Input Range | 0–5 A (direct) |
| Mounting | DIN rail |
| Dimensions (L×W×H) | 92 × 76 × 59 mm |
| Data Upload Protocol | HJ 212 (customizable) |
| Special Functions | Power-on/off alarm, cover-open detection, internal temperature monitoring, built-in antenna & terminal block |
| Enclosure Design | Tamper-resistant, fully integrated wiring |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PR-RM |
| Instrument Type | Online Raman Spectrometer |
| Gas Species | Benzene, Nitrogen, Hydrogen, Carbon Dioxide, Carbon Monoxide, Carbonyl Sulfide, Hydrogen Sulfide, Oxygen, Methane |
| Range | 0–100 %vol |
| Detection Limit | ≤50–100 ppm (gas-dependent) |
| Accuracy | ≤2 %FS |
| Measurement Cycle | 1–30 s (adjustable) |
| Sampling Method | Pump-aspirated with integrated pre-treatment |
| Environmental Robustness | Rated for high-pressure, high-temperature, high-humidity, high-dust, and hazardous-area operation |
| Maintenance | Consumable-free design |
Show next