Petroleum Specialized Analytical Instruments
Filter
Showing 91–120 of 439 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS325 |
| Pricing | Available Upon Request |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CuDDI |
| Pricing | Contact for Quote |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A-1190 |
| Price Range | USD 4,200 – 7,000 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Compliant Standards | GB/T 261-2008, GB/T 21615-2008, ASTM D93 |
| Repeatability | ≤2 °C |
| Ignition Method | Electronic spark ignition and adjustable gas flame |
| Temperature Range | 10–40 °C (ambient operating), 0–350 °C (test range) |
| Resolution | 0.1 °C |
| Data Storage | 120 test records onboard |
| Interface | RS-232 & RS-485 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Relative Humidity | <85% RH |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | A1017 |
| Measurement Range | 10–2,000,000 mPa·s |
| Rotor Set | Four standard spindles (No. 1–4) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm (stepped, not continuously variable) |
| Accuracy | ±1% of full scale (F.S.) |
| Display | Backlit high-contrast LCD showing viscosity, spindle number, rotational speed, sample temperature, % torque, and maximum measurable viscosity at selected speed |
| Data Output | RS232 serial interface for PC connectivity |
| Printing | Integrated thermal or impact dot-matrix printer support (via parallel/RS232) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Optional DC Input | 12 V / 1 A adapter |
| Operating Environment | 5–45 °C, ≤85% RH |
| Net Weight | 16 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Delite A1018 |
| Price | USD 13,800 (FOB Beijing) |
| Viscosity Range | 1000–1,000,000 mPa·s |
| Temperature Control Range (Bath) | −60 °C to +25 °C |
| Sample Temp Accuracy | ±0.1 °C |
| Bath Temp Stability | ±0.1 °C |
| Rotational Speeds | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Included Rotors | LV-1, LV-2, LV-3, LV-4 (4 total) |
| Power Supply | AC 220 V ±10%, ≤1500 W |
| Interface | RS-232C, PT100 temperature probe port |
| Cooling Method | Imported hermetic compressor |
| Calibration | Certified reference oils (ASTM D2983, ISO 3104 compliant) |
| Dimensions | 480 × 580 × 610 mm |
| Weight | 85 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable Instrument |
| Model | A1030 |
| Detection Target | Particulate Contaminants in Hydraulic & Lubricating Oils |
| Microscope Magnification | 100× |
| Particle Size Range | 5–150 µm |
| Cleanliness Rating Scales | NAS 1638 (Classes 00–12) and ISO 4406:2021 (Codes 1–24) |
| Filter Membrane Pore Sizes | 1.2 µm and 5 µm |
| Compliance Standard | DL/T 432–1992 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A1065 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Stirring Speed | 1500 rpm |
| Sample Capacity | 8 test tubes |
| Stirring Timer Range | 1–59 min |
| Sample Equilibration Timer | 1–59 min |
| Stirrer Shaft Pre-heat Timer | 1–59 min |
| Arm Dwell Time | 1–59 min |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤2000 W |
| Dimensions (W×D×H) | 572 mm × 335 mm × 791 mm |
| Net Weight | 38 kg |
| Compliance Standards | GB/T 7305, GB/T 7605 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | A1104 |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Control Range | RT+10 °C to 300 °C (minimum setpoint 50 °C) |
| Temperature Stability | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Rated Power | 1220 W |
| Test Stations | 4 glass vials |
| Rotation Speed | 5 rpm |
| Interior Chamber Dimensions | 425 × 400 × 345 mm |
| Overall Dimensions | 705 × 580 × 530 mm |
| Applicable Standards | SH/T 0301, ASTM D2619 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | A1121 |
| Price Range | USD 7,000 – 14,000 |
| Measurement Range | Ambient to –70 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Display | LCD Touchscreen |
| Printer | Thermal, 36-character Chinese/English output |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <300 W |
| Dimensions (W×D×H) | 460 × 310 × 480 mm |
| Weight | 21.3 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A1261 |
| Heating Method | Electric Furnace |
| Heating Power | 300 W + 600 W + 1000 W (Triple-Zone) |
| Temperature Control Range | 0–520 °C |
| Temperature Control Accuracy | ±5 °C |
| Total Power Consumption | ≤2000 W |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85 % RH |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Dimensions (W×D×H) | 345 × 345 × 381 mm |
| Net Weight | 22 kg |
| Compliance Standard | SH/T 0170 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A1460 |
| Product Category | Laboratory Instrument |
| Test Parameter | High-Temperature High-Shear Viscosity (HTHS) |
| Applicable Standards | SH/T 0703, ASTM D5481 |
| Power Supply | 220 V, 50 Hz |
| Temperature Control Method | Aluminum Block Bath |
| Test Temperature | 150 ± 0.1 °C |
| Capillary Inner Diameter | 0.15 mm |
| Capillary Effective Length | 16–18 mm |
| Gas Pressure Range | 0.5–3.5 MPa |
| Number of Capillary Cells | 1 |
| Detection Principle | Pressure-Driven Capillary Flow under Controlled Thermal and Shear Conditions |
| Automation | Fully Automated Timing, Pressure Stabilization Monitoring, HTHS Viscosity Calculation & Reporting |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | A2011 |
| Price | Upon Request |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Sensor | PT100 |
| Temperature Control Range | Ambient to 100 °C (adjustable) |
| Temperature Accuracy | ±1 °C |
| Heating Power (Main) | 600 W |
| Auxiliary Heating Power | 1000 W |
| Timer Range | 1 min to 24 h (programmable) |
| Temperature Display | LED digital |
| Time Display | LED digital |
| Test Positions | 4 independent reaction wells |
| Overall Dimensions | 480 mm × 360 mm × 520 mm (W × D × H) |
| Net Weight | 18 kg |
| Operating Humidity | ≤85% RH |
| Max. Power Consumption | ≤1800 W |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DRS2170 |
| Pricing | Upon Request |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | aqua 40.00 |
| Measurement Range | 1 µg – 100 mg |
| Resolution | 0.1 µg |
| Repeatability | ±3 µg (for 10–1000 µg water) |
| Temperature Control Range | 35 °C – 300 °C |
| Power Supply | 230 V |
| Sample Introduction | Optional automated sample changer |
| Gas System | Closed-loop, carrier-gas-free dynamic headspace |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software support |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aquamax KF PRO OIL |
| Product Type | Laboratory Instrument |
| Measurement Parameter | Trace Water Content (ppm to %) |
| Compliance | ASTM D6304, GB/T 11133 |
| Measurement Range | 0.0001–99% w/w |
| Heating Temperature Range | 35–250 °C (isothermal or programmable ramp) |
| Sample Introduction | Direct injection into heated furnace |
| Carrier Gas | Not required (closed-loop system) |
| Reagent Consumption | Single reagent cartridge supports >1000 determinations |
| Water Speciation | Differentiates free water and chemically bound water via thermal profiling |
| Blank-Free Operation | Eliminates need for blank correction |
| Form Factor | Benchtop / Portable field unit |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Sulfur Titrator |
| Pricing | Upon Request |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | TAN/TBN Titrator |
| Application Standard Compliance | IEC 62021-1, ISO 3771, ASTM D664, ASTM D2896, ASTM D4739 |
| Titration Method | Potentiometric Volumetric Titration in Anhydrous Medium |
| Measurement Range | 0.01–250 mg KOH/g |
| Resolution | 0.01 mg KOH/g |
| Power Supply | 100–240 V AC, 50/60 Hz, 30 VA |
| Stirrer Output | 12 V DC, 500 mA |
| Dimensions (W × H × D) | 30 × 45 × 30 cm (including reagent changer height) |
| Weight | ~3.5 kg (with reagent changer and empty bottles) |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, ASTM D4860 |
| Design | Integrated portable analyzer with built-in audio-guided test protocol |
| Test Duration | 5–10 minutes per sample |
| Sample Volume | Low-consumption (≤50 mL typical) |
| User Interface | Touch-sensitive control panel |
| Test Kit | Standard six-piece test assembly (pre-calibrated, disposable-compatible) |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 1143 |
| Pricing | Upon Request |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1153 |
| Measurement Range | 0–2000 pS/m |
| Resolution | ±1 pS/m (0–2000 pS/m) |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–50 °C |
| Display | 5-digit LCD with status text and LED illumination |
| Power | Three 3 V lithium batteries |
| Dimensions | 200.7 × 70 × 43.2 mm (L×W×D) |
| Probe Diameter | 19.05 mm |
| Weight | 365.8 g (12.9 oz) |
| Enclosure | Intrinsically Safe for Class I, Division 1, Group D hazardous locations |
| Compliance | ASTM D2624 |
| Optional Features | Temperature measurement mode, data hold, solvent-resistant hard-shell carrying case with O-ring sealed probe interface |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP737 |
| Pricing | Upon Request |
| Measurement Range | 0.0 °C to 1372 °C |
| Temperature Resolution | 0.1 °C (0.0–999.9 °C), 1 °C (>999.9 °C) |
| Temperature Accuracy | ±0.2% of reading |
| Ambient Operating Temperature | ≤30 °C |
| Relative Humidity | 10–70% RH |
| Storage/Transport Temperature | −25 °C to +55 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤2 kW |
| Dimensions (H×W×D) | 500 mm × 400 mm × 360 mm (main unit) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450, ASTM D7094, SH/T 0768 |
| Repeatability | Excellent |
| Ignition Method | Electric Arc Ignition |
| Temperature Range | −25 °C to 420 °C (standard configuration: 0 °C to 200 °C |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) |
| Cooling/Heating Technology | Patented PBT (Peltier-Based Thermoregulation) |
| Data Storage Capacity | >100,000 test reports with full audit trail |
| Power Supply | 85–264 V AC or 12 V DC |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Integrated Pollution Monitoring | CPT (Contamination Prevention Technology) |
| Optional Modules | EF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −40 °C to 200 °C (optional high-temp module up to 420 °C |
| LT module with external cooling | −40 °C to 120 °C) |
| Ignition Source | Electric Arc |
| Repeatability | ±4.1 °C |
| Compliance Standards | ASTM D6450, ASTM D7094, SH/T 0768–2005 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash S10 |
| Detection Method | Closed-Cup (ASTM D93 / ISO 2719 / IP 34 / GB/T 261 / SH/T 0768) |
| Temperature Range | −25 °C to 200 °C (optional high-temp module up to 420 °C) |
| Temperature Accuracy | ±0.1 °C |
| Test Duration | 3–5 min per sample (including cup cleaning) |
| Sample Volume | 1 mL or 2 mL |
| Auto-sampler Capacity | 10 positions |
| Data Storage | 100,000 test records |
| Display | 7-inch full-color capacitive touchscreen (Chinese UI) |
| Interfaces | 3× USB, 1× Ethernet, 1× RS232, LIMS-compatible serial protocol |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Option | 12 V / 4 A |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash X |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | 18 °C to 370 °C |
| Ignition Method | Electric Arc Ignition |
| Repeatability | High |
| Compliant Standards | ASTM D7094, SH/T 0768 |
| Sample Volume | 2 mL |
| Cooling/Heating Technology | Peltier-Based Thermoelectric (PBT) |
| Data Storage Capacity | >100,000 test reports |
| Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 85–264 V AC or 12 V DC |
| Pollution Control | CPT Electrode Protection & Self-Cleaning Ignition System |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | CRUDE |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | −20 to 120 °C |
| Compliance | ASTM D6377, D6378, D5191, D5188, D6897, GB/T 11059, SH/T 0769, SH/T 0794, SN/T 2932, EN 13016 |
| Sample Handling | Heated high-viscosity module, integrated oscillator, pure-sampling valve, automatic liquid/gas purge |
| Brand | ERALYTICS |
|---|---|
| Origin | Imported |
| Model | ERASPEC DIESEL |
| Measurement Principle | Mid-IR Fourier Transform Infrared (FTIR) Spectroscopy |
| Measurement Items | Cetane Number (CN), Cetane Index (CI), Fatty Acid Methyl Esters (FAME), Total Aromatics, Polycyclic Aromatic Hydrocarbons (PAH), Distillation Temperatures (T85, T90, T95), Cetane Improvers, Biodiesel Content, Fatty Acid Ethyl Esters (FAEE), Rapeseed Oil, Dimethoxymethane (DMM), etc. |
| Sample Volume | 10 mL |
| Analysis Time | ≤ 60 s |
| Portability | Fully Portable (Lab & Field-Deployable) |
| Spectral Range | 631–45890 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ (data acquisition at 0.5 cm⁻¹) |
| Wavelength Accuracy | < 0.01 cm⁻¹ |
| Signal-to-Noise Ratio | > 10,000:1 |
| Density Measurement Accuracy | ±0.0001 g/cm³ |
| Data Storage Capacity | ~6,000 results |
| Power Supply | 85–264 VAC, 47–63 Hz, 70 W |
| DC Input | 12 V / 8 A (vehicle-compatible) |
| Dimensions | 290 × 350 × 340 mm |
| Weight | 9.7 kg |
| Compliance | GB/T 33648–2017 (detection of illegal diesel additives), EN 14078, GB 23801 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC |
| Portability | Portable |
| Detection Principle | Mid-Infrared Spectroscopy |
| Measurement Range (Octane Number) | 70–105 |
| Accuracy | ±0.1 ON |
| Analysis Time | 60 seconds |
| Sample Volume | 10 mL |
| Compliance | GB/T 33648–2017 (Illicit Additives), ASTM D6227 (Benzene), ASTM D5845 (Oxygenates) |
| Spectral Range | 631–45,890 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Wavenumber Accuracy | < 0.01 cm⁻¹ |
| Signal-to-Noise Ratio | > 10,000:1 |
| Built-in Density Measurement | ±0.0001 g/cm³ |
| Data Storage Capacity | ~6,000 results |
| Interface Options | 5× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Power Supply | 85–264 VAC / 47–63 Hz / 70 W or 12 VDC / 8 A (vehicle power) |
| Dimensions | 290 × 350 × 340 mm |
| Weight | 9.7 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC JET |
| Application | Gasoline Octane Number and Diesel Cetane Number Analysis |
| Portability | Portable |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Measurement Range | 0–170 (Octane/Cetane Scale) |
| Accuracy | ±0.01 |
| Measurement Time | 60 s |
| Sample Volume | 10 mL |
| Spectral Range | 4000–400 cm⁻¹ |
| Data Points | Up to 3000 per spectrum |
| Density Measurement Accuracy | ±0.0001 g/cm³ (integrated Anton Paar density module) |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Input | 12 V / 4 A (vehicle-compatible) |
| Storage Capacity | ≥2000 test records |
| Interfaces | 3× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Compliance | ASTM E2412, D2688, D7412–D7418, D7624 |
| Measurement Principle | Mid-IR Absorption Spectroscopy with Fixed-Path Transmission Cell |
| Sample Volume | 10 mL |
| Flow Path Cell Thickness | 100 µm |
| Viscosity Range | 0–2000 cSt (at 20 °C) |
| Analysis Time | 60–120 s (viscosity-dependent) |
| Warm-up Time | ≤30 s |
| Auto-sampling | Integrated precision peristaltic pump |
| Auto-cleaning | Solvent or next-sample flush |
| Display | 7-inch capacitive touchscreen |
| Connectivity | Ethernet (RJ45), USB 2.0, RS-232 |
| Data Storage | ≥3000 full spectral reports with metadata |
| Remote Access | Yes, via Ethernet-enabled diagnostic and service interface |
| Alarm Logging | Timestamped event tracking with result correlation |
| Software Compliance | Audit-trail capable |