Physical Property Testing Instruments
Filter
Showing 271–300 of 4354 results
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer | Analysis, Inc. |
| Product Type | Imported |
| Model | TCP Ultrasonic C-Scan System |
| Pricing | Available Upon Request |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | 128-105 |
| Channel Capacity | 128 independent DC resistance monitoring channels |
| Minimum Event Duration | 0.1 / 0.5 / 1.0 µs (field-replaceable clock modules support additional durations) |
| Threshold Resistance Range | 0.1–2000 Ω |
| Sensing Current Options | 1, 5, 10, 20, 50, 100 mA |
| Max Compliance Voltage | 2.5 V |
| Threshold Tolerance | ±5% |
| Event Detection Sensitivity | 100 ns |
| Operating Temperature | ≤35 °C |
| Power Supply | 120 VAC, 60 Hz, 6 A |
| Dimensions | 11.5" H × 18" W × 15.5" D |
| Weight | 51 lb |
| Interface | USB or RS-232C |
| Software | WinDatalog v5.x for data acquisition, event logging, and statistical analysis |
| Compliance | Designed for GLP/GMP-aligned test environments |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | 32-106 |
| Channel Capacity | 32 |
| Minimum Event Duration | 0.1 / 0.5 / 1.0 µs (field-replaceable clock module supports other durations) |
| Threshold Resistance Range | 0.1–2000 Ω |
| Channel Test Current | 1, 5, 10, 20, 50, 100 mA |
| Compliance Voltage | ≤2.5 V |
| Threshold Tolerance | ±5% |
| Interface | USB & RS-232C |
| Software | WinDatalog v5.x |
| Operating Temperature | ≤35 °C |
| Power Supply | 120 VAC, 60 Hz, 3 A |
| Dimensions (H×W×D) | 7.5″ × 18″ × 16.5″ |
| Weight | 26 lb |
| Warranty | 1 year parts and labor |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | CTE-360 |
| Temperature Range | –25 °C to +100 °C |
| Compliance | ASTM D696, ASTM E228 |
| Sample Max Cross-Section | 12.5 mm (0.5 in) |
| Recommended Sample Length | 50 mm (2 in) |
| CTE Accuracy | ±3% (full 100 °C range) |
| Power Supply | 100–230 VAC, 50/60 Hz, ≤400 W |
| Dimensions | 43 × 43 × 43 cm (17 × 17 × 17 in) |
| Weight | 9 kg (20 lb) |
| Software | WinCTE v1.x (Windows 7–11, 32/64-bit) |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | Phase12 |
| Heating Current Options | 2 A / 10 A / 20 A / 100 A (Phase12B) |
| Sampling Rate | 1 MHz |
| Temperature Resolution | ±0.007°C (Tj digital), ±0.1°C (display), ±0.2–0.5°C (absolute) |
| Thermocouple Accuracy | ±0.15°C (typ.), ±0.3°C (max.) |
| Heating Voltage Accuracy | ±0.2% rdg + 0.025% FS (50 V) for Phase12 |
| Transient Time Resolution | 1 µs |
| Transient Span | 1 µs – 1000 s |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | PHASE12 |
| Compliance | JEDEC JESD51-1, JESD51-14, JESD51-8, JESD51-12 |
| Thermal Resolution | ±0.007°C |
| Junction Temperature Accuracy | ±0.1°C |
| Voltage Measurement Accuracy | ±0.25% (0–30 V) |
| Current Measurement Accuracy | ±0.25% |
| Sampling Rate | 1 MHz |
| Max Standard Current Output | 18 A |
| Optional High-Current Power Booster | up to 1000 A |
| Junction Sensing Current Options | 1–50 mA |
| Calibration Temperature Range | Ambient to 180°C |
| Input Power | 220 VAC, 5 A, 50/60 Hz |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | STD Event Detectors |
| Pricing | Upon Request |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | STD Event Detectors Accessories |
| Type | Field-Upgradeable Hardware Modules and Interconnect Solutions for Electrical Continuity Interruption Testing |
| Compliance | Designed for use with ASTM F1978, IPC-TM-650 2.6.23, MIL-STD-883H Method 2014, and IEC 60068-2 environmental test correlation workflows |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | TIM1300 / TIM1400 |
| Test Method | ASTM D5470 |
| Sample Diameter | 1.3 in (33 mm) |
| Thickness Range | 0–20 mm |
| Temperature Range | 20–65°C (TIM1300), 20–130°C (TIM1400) |
| Contact Pressure Range | 5–380 psi (34–2600 kPa) |
| Thickness Measurement Accuracy | ±1% + 0.001 in (±25 µm) |
| Thermal Resistance Range | 0.005–8 K/W |
| Power Supply | 100–230 VAC, 50/60 Hz |
| Cooling Requirement | 6 L/min @ 10–35°C, ±0.1°C stability |
| Compressed Air | ≥90 psi (600 kPa), 10 µm filtration |
| Dimensions (H×W×D) | 58×41×43 cm |
| Weight | 19 kg (TIM1300), 21 kg (TIM1400) |
| Brand | ANALYSIS TECH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | TIMTester 1300, TIMTester 1400 |
| Pricing | Upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | U-AT |
| Instrument Type | Digital |
| Flaw Detection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model Variants | UPK-T24, UPK-T36, UPK-T48, UPK-T60, UPK-T72 |
| Water Tank Dimensions (L×W×H) | 600×450×300 mm (UPK-T24) to 4000×4000×900 mm (Custom Large-Format Systems) |
| Motion Axes | 4–8 axes with encoder feedback |
| Positioning Accuracy | ≤ 0.05 mm |
| Maximum Scan Speed | 500 mm/s |
| Ultrasonic Data Acquisition | PCIe-based integrated excitation & 14-bit ADC card |
| Bandwidth | Up to 32 MHz |
| Sampling Rate | 250 MS/s |
| Software Platform | UTwin — Multi-window, multi-modal (A/B/C/3D/CT) scanning and analysis suite |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T156 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 4000 × 1500 × 900 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T24 |
| Scanning Range | 600 × 450 × 300 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | UPK-T48 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 1200 × 900 × 600 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer | Analysis GmbH |
| Origin Category | Imported |
| Model | UX20 |
| Price | Upon Request |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| Sample Load Capacity | 100 kg |
| Dimensions (W×D×H) | 2240 × 1770 × 2350 mm |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer | Analysis GmbH |
| Origin Category | Imported |
| Model | UX50 |
| Pricing | Upon Request |
| Detector Type | Flat-Panel Detector (FPD) |
| Scanning Mode | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| Maximum Sample Weight | 100 kg |
| Dimensions (L×W×H) | 2250 × 1770 × 2350 mm |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Price | Upon Request |
| Operating Temperature Range | -200 °C to +350 °C |
| Battery Life | 3–4 years (typical continuous operation) |
| Communication Protocols | WirelessHART (IEC 62591), Zigbee |
| Channels | 4 independent ultrasonic measurement channels |
| Environmental Rating | IP67-rated enclosure |
| Dual-Sensor Capability | Simultaneous thickness + ambient temperature measurement |
| Probe Compatibility | Single-crystal and dual-crystal ultrasonic transducers |
| Data Transmission | Secure, encrypted wireless transmission to local SCADA or cloud-based asset integrity platforms |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | Y.cougar |
| Detector Type | Flat-panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 160 kV |
| Penetration Capability | Up to 350 mm steel-equivalent thickness |
| Accuracy | Nanoscale |
| Application Modes | 2D Radiography, 3D Computed Tomography (CT), Hybrid 2D/3D |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Y.MU2000-D |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 225 kV |
| Maximum Penetration | 350 mm (steel equivalent) |
| Inspection Envelope | 800 mm × 1100 mm (diameter × height) |
| Dimensional Measurement Accuracy | ±0.011 mm |
| Density Measurement Accuracy | ±0.2% |
| Maximum Sample Weight | 100 kg |
| System Dimensions | 3700 mm × 2300 mm × 2800 mm (L × W × H) |
| Brand | AnalysisTech |
|---|---|
| Origin | USA |
| Model | Phase12B |
| Heating Current Capacity | 100 A (max) |
| Max Heating Voltage | 20 V |
| Thermocouple Accuracy | ±0.15°C (typ.), ±0.3°C (max.) |
| Tj Measurement Resolution | ±0.007°C (typ.) |
| Tj Absolute Accuracy | ±0.2–±0.5°C (typ.) |
| Sampling Rate | 1 MHz |
| Dimensions | 17" × 17" × 7.5" H, 25 lb |
| PC Requirements | Windows 7/10 Pro (64-bit), 3 GHz CPU, 2 GB RAM, 500 GB HDD, 4+ USB ports |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / GF-300D |
| Instrument Type | Buoyancy-Based Density Balance |
| Measurement Principle | Archimedes’ Principle |
| Weighing Capacity | 300 g (EK-300iD), 310 g (GF-300D) |
| Weighing Readability | 0.01 g (EK-300iD), 0.001 g (GF-300D) |
| Density Resolution | 0.001 g/cm³ |
| Display | Backlit LCD (16 mm character height, EK-iD series) |
| Stabilization Time | ≤1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Environmental Response Modes | FAST / MID / SLOW |
| Calibration | Full-digital span calibration with user-adjustable reference weight input |
| Temperature Compensation | Direct water temperature or reference liquid density entry |
| Density Comparison Mode | Hi / OK / Lo alarm output (optional external relay module) |
| Auto Power-Off | Configurable after ≥10 min inactivity |
| Interface | RS-232C standard port |
| Software | WinCT v3.x (Windows-compatible, supports Excel/Office data export, statistical analysis, time-series logging, and chart-based visualization) |
| Compliance | Built-in GLP/GMP/ISO audit trail functions (date/time stamping, instrument ID, calibration history, operator ID, measurement statistics) |
| Brand | Ankersmid |
|---|---|
| Origin | USA |
| Model | PSA-300LC and PSA-1000 |
| Gas Inlets | 2 (customizable) |
| Heating Temperature Range | 0–350 °C |
| Isothermal Stability | ±0.1 °C |
| Pressure Range | 0–1000 psi (68.9 bar) |
| Test Function | Simulated PSA/TSA/VSA Cycles, Breakthrough Curve Analysis, Multicomponent Gas Adsorption |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6010T |
| Temperature Range | 26–60 °C (standard), 15–70 °C (extended) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Measurement Range | 0–100 / 1,000 / 10,000 pphm |
| Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±0.2 % of reading (ozone sensor) |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Recovery Time to 95 % Set Ozone Level | ≤10 min |
| Recovery Rate | 0.4 K/min |
| Temperature Compensation | Automatic, 0–60 °C ±1 °C |
| Pressure Compensation | Automatic, 600–1500 mbar ±2 mbar |
| Zero Drift | Auto-zeroing cycle every 2 s |
| Span Drift | None (single-beam optical design) |
| Power Supply | 230 V / 50 Hz |
| External Dimensions | 950 × 870 × 610 mm |
| Usable Internal Volume | 680 × 650 × 400 mm |
| Generator/Controller/Detector Cabinet | 1600 × 550 × 600 mm |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6050-T |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity in Test Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm |
| External Dimensions | 670 × 620 × 510 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6300 |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Range | 0–100 / 1,000 / 10,000 pphm |
| Response Time | 5 s |
| Detection Limit | 1 pphm |
| Accuracy | ±0.2% of reading |
| Repeatability | ±0.2% of full scale |
| Temperature Control Range | 15–70 °C (RT = 23 °C) |
| Temp. Accuracy | ±5 K |
| Temp. Ramp Rate | 0.4 K/min |
| Humidity Range | 30–80% RH |
| Humidity Accuracy | –1 to +4% RH |
| Humidity Stabilization Time to 95% | ≤20 min |
| Ozone Control Range | 20–200 pphm |
| Ozone Control Accuracy | ±1 pphm |
| Ozone Stabilization Time to 95% | 10 min |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 680 × 650 × 400 mm |
| External Dimensions | 950 × 870 × 610 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 7500 |
| Temperature Range | 26–60 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive ultraviolet (NDUV) absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm (standard) |
| Power Supply | 230 V / 50 Hz |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM 8000 |
| Chamber Volume | 8000 L |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV Absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±1 pphm (ozone), ±5 K (temperature), −1 to +4 % RH (humidity) |
| Airflow Velocity in Test Zone | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Power Supply | 230 V / 50 Hz |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM-6300 |
| Internal Dimensions | 680 × 680 × 500 mm |
| External Dimensions | 1610 × 1500 × 1000 mm |
| Gas Flow Velocity | 8–700 mm/s |
| Air Exchange Rate | 50–500 L/min |
| Air Replacement Rate | 1–2000 dm³/h (33 L/min) |
| Temperature Range | RT to 70 °C ±0.5 °C |
| Humidity Range | 30–90 %RH (±1/+4 %RH) |
| Ozone Measurement Principle | Single-beam NDUV Photometry |
| Ozone Concentration Range | 0–1999 mg O₃/Nm³ or 0–1000 ppmv |
| Sensitivity | 0.001 ppmv |
| Accuracy | <1 % SCE |
| Linearity | 98 % SCE |
| Ozone Generation Method | Corona Discharge (COM-ADM) |
| Ozone Output Capacity | 10–2000 mg/h |
| Ozone Flow Rate | 100–2000 NL/h |
| Power Consumption | 3000 W |
| Voltage | 230 V, 10 A |
| Weight | 250 kg |
| Compliant Standards | ASTM D1149, ASTM D2802, ASTM D4246-02, ASTM D4575, ASTM D470, ASTM D518, BS 903 A43, DIN 53509-2-1, FORD FLTM BP101-01, GB/T 11206-2009, GB/T 13642-1992, GB/T 2951.1–2951.10-1997, GB/T 2951.21-2008, GB/T 7762-2003, HG/T 2716-2008, HG/T 2869-1997, ISO 1431-1 & -3, MIL-STD-1344A, NGF 37112, SAE J1401, SIS 16 12 10 |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM6200-T-CL |
| Chamber Volume | 230 L |
| Internal Dimensions (H×W×L) | 50 × 68 × 68 cm |
| Total Dimensions (H×W×L) | 181 (+43) × 99 × 120 (+10) cm |
| Weight | 400 kg |
| Power Supply | 230/120 VAC, 50/60 Hz |
| Ozone Concentration Range | 0–1000 pphmv |
| Airflow Velocity (in chamber) | 8–16 mm/s (longitudinal, laminar flow) |
| Reynolds Number (Re) | 300–1000 |
| Loading Factor | G = 12 s/m (per ISO 1431-1) |
| Certified Ozone Analyzer | MP60602 |
| Ozone Generator | Maintenance-Free Type |
| Control System | Siemens SIMATIC S7-300 PLC with 15″ Touchscreen HMI |
| Data Interface | RS232, USB |
| Safety Features | Catalytic ozone destruct, activated carbon filter, turbofan recirculation, interlocked safety door, audible/visual alarms |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |