Physical Property Testing Instruments
Filter
Showing 6691–6720 of 12514 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSC Series (UV-DSC, Optical DSC, Microscope-DSC) |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1 |
| Temperature Range | −150 to 700 °C (configurable low-end: −150, −100, −90, −70 or −35 °C) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor), 0.01 µW (HSS8 sensor) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1+ Microscopy System, HP DSC1+ Microscopy System |
| Temperature Range | DSC1+: −150 to 700 °C |
| HP DSC1+ | RT to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Pressure Range (HP variant) | Vacuum to 2 MPa |
| Microscope Integration | Compatible with Olympus, Leica, and other OEM optical platforms |
| Compliance | Designed for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | −150 °C to 700 °C (standard), up to 1100 °C (optional furnace) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–250 K/min |
| Heat Flow Sensitivity | 0.04 µW (FRS 5+ sensor), 0.02 µW (HSS 8+ sensor) |
| Sensor Type | MultiSTAR® DSC Sensor (56- or 120-pair Au/Au-Pd thermocouples, star-arranged on ceramic substrate with Al₂O₃ coating) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | –150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS 6+ sensor), 0.02 µW (HSS 9+ sensor) |
| Sensor Configuration | 56-pair (FRS 6+) or 120-pair (HSS 9+) Au/Au-Pd thermocouples in star geometry |
| Compliance | ASTM E794, ISO 11357, USP <1163>, FDA 21 CFR Part 11 (with optional software modules) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D30/D40 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Vibrating Tube) |
| Sample Type | Liquids |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00002 g/cm³ |
| Temperature Control Range | 0 to 91.0 °C |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 160, DIN 51757 |
| Data Management | FDA 21 CFR Part 11 compliant software support (via EasyDirect™), GLP/GMP audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy D30, Easy D40 |
| Instrument Type | Benchtop Digital Density Meter |
| Sample Type | Solid and Liquid |
| Density Range | 0–3 g/cm³ |
| Temperature Range | 15–25 °C (Easy D30), 15–50 °C (Easy D40) |
| Density Resolution | 0.001 g/cm³ (Easy D30), 0.0001 g/cm³ (Easy D40) |
| Density Accuracy | ±0.001 g/cm³ (Easy D30), ±0.0005 g/cm³ (Easy D40) |
| Temperature Accuracy | ±0.2 °C (Easy D30), ±0.1 °C (Easy D40) |
| Minimum Sample Volume | 1.2 mL |
| Measurement Units | Density, Specific Gravity, Alcohol % v/v, Brix, API Gravity, Acidity, Urea Concentration, Custom Concentration |
| Built-in Methods | 16 |
| Bubble Detection | BubbleCheck™ (Easy D40 only) |
| Viscosity Correction | Automatic (both models) |
| Cleaning Check | Yes (both models) |
| Dimensions (W × H × D) | 170 × 156 × 273 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyViewer 400 |
| Instrument Type | In-line Dynamic Imaging System |
| Number of Lenses | 1 |
| Field of View | 1100 µm × 800 µm (±50 µm) |
| Image Resolution | 2200 × 1700 pixels |
| Sample Dispersion Method | In-situ liquid-phase flow-through measurement |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyViewer100 |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Number of Lenses | 1 |
| Measurement Range | 1.5 µm – 1 mm |
| Sample Dispersion Method | In-line liquid-phase measurement |
| Image Resolution | 1.5 µm |
| Measured Parameters | Chord Length, Aspect Ratio, Equivalent Diameter, Length, Width |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55 / MP70 / MP80 / MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Diameter Compatibility | <1.8 mm |
| Sample Capacity | Up to 6 samples simultaneously |
| Compliance | GLP/GMP-ready, ISO/IEC 17025-aligned calibration traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP70 / MP90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Sample Capacity | Up to 6 capillaries per run |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ISO 11357-3, ASTM D1519 |
| Safety | Integrated optical monitoring with simultaneous transmittance measurement and reflected-light imaging |
| User Interface | One Click® color touchscreen with pre-stored method recall |
| Qualification Support | Factory-supplied IQ/OQ documentation and on-site qualification services available |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1 to 20 °C/min |
| Temperature Accuracy | ±0.2 °C (30–200 °C), ±0.5 °C (200 °C to Tmax) |
| Sample Capacity | Up to 4 samples |
| Display | 5.7" VGA color touch screen |
| Video Resolution | Color AVI, >6× magnification |
| Data Export | PDF reports, GLP/GMP-compliant audit trail |
| Compliance | 21 CFR Part 11 ready (with LabX software) |
| Power Consumption | 120 W |
| Dimensions | 18 × 35 × 19 cm |
| Weight | 4.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | FillPal™, InMotion™, SC1(H), SC30(H) |
| Application Scope | Fully automated sample introduction, rinsing, drying, and (where applicable) heating for density and refractive index measurement |
| Compliance Context | Designed to support GLP/GMP workflows with audit-trail-capable software integration |
| Fluid Handling Architecture | Positive-pressure filling (SC-series), peristaltic pumping (FillPal/InMotion), chemically resistant wetted materials (e.g., PTFE, ETFE, sapphire, Hastelloy C-276 where specified) |
| Temperature Control | Ambient-only (FillPal, InMotion, SC1/SC30) or heated up to 100 °C (SC1H/SC30H) |
| Sample Capacity | 1 (FillPal, SC1, SC1H) or up to 303 positions (InMotion), or 30 vials (SC30, SC30H) |
| Cleaning Protocol | Full-cycle automated rinse-dry sequence with configurable solvent selection and dwell times |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | DSC |
| Temperature Range | –95 °C to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor) |
| Simultaneous Sample Measurement | Multiple |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC 2+ |
| Temperature Range | −95 °C to 1,000 °C |
| Heating Rate | 6 K/min to 2,400,000 K/min |
| Cooling Rate | 6 K/min to 240,000 K/min |
| Maximum Heat Flow Signal | 20 mW |
| Heat Flow Noise | < 0.5 µW |
| Sensor Type | UFS1 MEMS-based chip calorimeter with 16 thermocouple pairs (8 per sample/reference side) |
| Measurement Principle | Dynamic power compensation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC |
| Temperature Range | –95 to 450 °C |
| Heating/Cooling Rates | Up to 10⁶ K/s (heating), up to 10⁵ K/s (cooling) |
| Sensor Response Time | < 1 ms |
| Sample Mass Range | 1–500 ng |
| Compliance | ISO 11357, ASTM E794, ASTM E1269, USP <1151>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP82HT / FP84HT |
| Temperature Range | –60 to 375 °C |
| Temperature Repeatability | ±0.2 °C |
| Optical Field of View | Ø2.5 mm (FP82HT), Ø2.0 mm (FP84HT) |
| DSC Sensor | Au–Ni thermopile, 5 thermocouple pairs |
| Calorimetric Sensitivity | 13 mV/mW |
| Sample Environment | Sealed furnace chamber with inert gas compatibility |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP83/HT |
| Temperature Range | –25 to 375 °C |
| Temperature Accuracy | ±0.2 °C |
| Heating Rate | 0.1–20 °C/min |
| Dropping Point Orifice Diameter | 2.8 mm |
| Softening Point Orifice Diameter | 6.35 mm |
| Compliance | ASTM D3104-82, ASTM D3461-85, ASTM D3954, DIN 51920 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP900 |
| Temperature Range | −100 to 600 °C |
| Heating/Cooling Rate | 0–20 °C/min |
| Temperature Resolution | 0.1 °C |
| Sensor Type | PT100 |
| Display | Graphical LCD (60 × 256 pixels, 6 lines × 36 characters) |
| Method Storage | 15 preloaded + 35 user-defined methods |
| Compliance | ASTM, DIN, ISO, USP <741>, GLP/GMP-ready |
| Interface | RS232C |
| Measurement Units Support | °C, °F, K |
| Environmental Operating Range | 20–32 °C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC 2+ |
| Temperature Range | RT to 500 °C / 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Pressure Range | 0–10 MPa |
| Gas Flow Control | External pressure & mass flow controller supported |
| Atmosphere Compatibility | Inert, oxidizing, reducing, reactive (e.g., N₂, O₂, H₂, CO₂, C₂H₄, CH₃Br), with safety restrictions for combustible/toxic gases |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC1 |
| Temperature Range | 22–500 °C (optional to 700 °C) |
| Heating/Cooling Rate | 0.1–50 °C/min |
| Pressure Range | 0–10 MPa |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Sensor Type | FRS5 (56 thermocouple pairs, star configuration) / HSS8 (120 thermocouple pairs, triple-layer configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HS84 |
| Temperature Range | RT to 375 °C (optional cooling to –90 °C) |
| Heating/Cooling Rate | 0.1–20 K/min |
| Light Aperture | 2 mm |
| Sensor Type | DSC ceramic sensor with 56 thermocouple pairs |
| Sample Carriers | Glass slides, top cover glass, aluminum/glass/sapphire crucibles |
| Crucible Dimensions | Ø6 mm / 40 µL |
| Display | 7″ touch-sensitive VGA color screen |
| Supported Languages | English, German, French, Spanish, Chinese, Japanese, Korean, Russian |
| User Shortcuts | 12 per user |
| Compliance | ASTM F766, EN ISO 3146 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55/80 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 4 °C/min (programmable) |
| Sample Capacity | 6 positions |
| Measurement Modes | Melting Point (MP), Melting Range (MR), Sliding Melting Point (SMP), Boiling Point (BP), Cloud Point (CP) |
| Video Recording Duration | 60 minutes |
| Maximum Results Storage | 50 entries |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ASTM D1565, ISO 4625 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP70 |
| Temperature Range | Room Temperature to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.2 °C (30–200 °C), ±0.5 °C (200–350 °C) |
| Capillary Diameter | <1.8 mm |
| Sample Capacity | 4 capillaries |
| Temperature Resolution | 0.1 °C |
| Cooling Time from Tmax | 7 min |
| Heating Time to Tmax | 5 min |
| GLP Compliance | Yes |
| Pharmacopoeial Compliance | Ph.Eur. 2.2.60, USP <741>, JIS K 0064, ASTM D1519 |
| Video Output | Color AVI, 6× digital zoom, SD card storage (up to 300 min), real-time recording |
| Data Export | PDF reports, MS Excel-compatible intensity data, method & result archiving |
| Method Storage | Up to 20 user-defined methods |
| Reference Substance Database | Up to 5 substances |
| User Authentication | Yes |
| One-Click™ Presets | Up to 12 per user |
| IQ/OQ Documentation | Available as optional service |
| Barcode Scanner Interface | USB |
| Printer Support | USB-P25 compact printer, PCL-compatible Ethernet printers |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | Programmable (5 min to Tmax from 50 °C) |
| Cooling Time (Tmax to 50 °C) | 6 min |
| Capillary Capacity | 6 melting point capillaries per run |
| Sample Throughput | Up to 12 measurements per user session |
| Display | 7-inch full-color touchscreen |
| Video Resolution | High-definition color video recording (300 min total storage) |
| Data Export | SD card, USB drive, or direct PC connection |
| Compliance | 21 CFR Part 11 and EU Annex 11 (with LabX software) |
| Audit Trail | Available via LabX software |
| Report Format | PDF (60 stored reports) |
| Reference Substance Library | 100 entries |
| Dimensions (W × H × D) | 18 × 35 × 19 cm |
| Weight | 4 kg |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Russian, Japanese, Korean |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | R-Series Signature |
| Compliance | HACCP, FDA 21 CFR Part 11 (with optional audit trail), ISO 22000, BRCGS Food Safety Issue 9, IFS Food v7, USP <1043> (for pharmaceutical applications) |
| Detection Capability | Ferrous, non-ferrous, and stainless steel contaminants (including 304/316 austenitic grades) in packaged, bulk, powder, and viscous product streams |
| Integration | Compatible with conveyor belts, gravity-fed chutes, pipe-based flow systems, and automated reject mechanisms |
| Regulatory Support | Factory-calibrated per ASTM F1359–22 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Series | R/T/L/Series |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RC1mx |
| Instrument Type | Reaction Calorimeter |
| Temperature Range | −70 °C to 300 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Accuracy | ±0.5 K |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP/GMP-aligned process safety development and regulatory submission support (e.g., ICH Q5, Q9, Q11 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SC1 / SC30 |
| Sample Capacity | 1 vial (20 mL, 9 mL, or 6 mL) |
| Maximum Sample Viscosity | ≤ 30,000 mPa·s |
| Sample Introduction Method | Positive-pressure pumping |
| Cleaning Protocol | Dual-solvent automated rinse and dry |
| Drying Method | Pneumatic-assisted air-drying |
| Temperature Control | Optional electric heating module (for sample pre-conditioning) |
| Sample Recovery | Optional automatic return to source vial |
| Compliance | Designed for integration with METTLER TOLEDO DE (density), RE (refractometry), and DR (combined density/refractometry) instruments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Signature/Profile |
| Pricing | Upon Request |