Physical Property Testing Instruments
Filter
Showing 6661–6690 of 12514 results
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+1000 / DMA+2000 + Xpander |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Automation Level | Fully Automated Robotic System |
| Compliance | Designed for ISO 6721, ASTM D4065, ASTM D7028, ISO 11359-2, and USP <1031> compliant testing environments |
| Operating Modes | Tension, Compression, Dual Cantilever, Single Cantilever, Shear |
| Sample Capacity | Up to 120 specimens per rack (configurable) |
| Footprint | < 1.2 m² |
| Control Interface | Touchscreen HMI + Ethernet-connected PC workstation |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+2000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | −1000 N to +1000 N (peak-to-peak: 2000 N) |
| Displacement Range | ±6 mm (peak-to-peak: 12 mm) |
| Frequency Range | 1×10⁻⁵ Hz to 200 Hz (optional up to 1000 Hz) |
| Minimum Detectable Force | 0.01 N |
| Minimum Detectable Displacement | 0.1 µm |
| Modulus Measurement Range | 500 Pa to 3×10¹² Pa (6 decades) |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+NG |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) with Integrated Crack Growth Module |
| Temperature Range | −150 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 0.1–500 N |
| Displacement Range | 0.1–6000 µm |
| Frequency Range | 10⁻⁵–200 Hz |
| Crack Measurement Channels | 2 or 4 simultaneous crack tip tracking positions |
| In-situ Initial Crack Generation | Yes, inside climate-controlled chamber |
| Chamber Oxygen Control | 10 ppm–20% O₂ adjustable |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA25/50 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 500 °C (upgradable to 600 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Ramp Rate | ±0.1 to ±10 °C/min |
| Dynamic Force Range | ±25/±50 N (peak-to-peak: 50/100 N) |
| Displacement Range | ±3/±6 mm |
| Frequency Range | 1×10⁻⁵ to 200 Hz |
| Modulus Range | 10⁵ to 10¹¹ Pa |
| Compliance | ASTM D4065, ISO 6721, ISO 11357-2, USP <1031>, FDA 21 CFR Part 11 (software-enabled) |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | VHF104 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −50 to 110 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–10 °C/min |
| Frequency Range | 100–10,000 Hz |
| Force Range | ±150 N |
| Displacement Range | ±10,000 µm |
| Strain Range | 10⁻⁶–30% |
| Deformation Modes | Tension, Compression, Annular Shear |
| Standard Masses | 5, 10, 20, 40, 80, 200 g |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | HallinSight® 3D |
| Quotation | Upon Request |
| Brand | Auniontech (Distributor) |
|---|---|
| Origin | Shanghai, China |
| Package | QFN 3 × 3 × 0.9 mm³, 16-pin + thermal pad |
| Supply Voltage | 3.3 V or 5 V |
| Output Options | Analog (Bx/By/Bz/T) or Digital (SPI) |
| Configurable Ranges | ±0.1, ±0.3, ±1, ±3, ±10, or ±30 T |
| Resolution Options | 14-, 15-, 16-, or 16+-bit |
| Sampling Rates | 375 / 750 / 1500 / 3000 Hz |
| RMS Noise | <2.0 LSB (at 16+-bit) |
| Noise Density | 300 nT/√Hz |
| Analog Bandwidth | 50 kHz |
| Operating Temperature | −40 °C to +125 °C (LN₂-tested) |
| Sensing Volume | 200 × 200 × 5 µm³ |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | TFM1186 |
| Pricing | Upon Request |
| Brand | Metrolab |
|---|---|
| Model | THM1176 |
| Sensor Type | Hall-effect triaxial probe |
| Measurement Range | 1 nT to 14 T |
| Frequency Bandwidth | DC to 1 kHz |
| Accuracy | ±1% (full-scale, isotropic total field) |
| Power Supply | USB bus-powered (5 V ±5%) |
| Output Resolution | 167 ns timestamp precision |
| Sampling Rate | 0.36 Sa/s to 6.8 kSa/s (per axis) |
| Operating Temperature | 0 °C to 40 °C |
| Compliance | CE, RoHS, USB-IF certified |
| Calibration | NIST-traceable certificate included |
| Software | EZMag3D (Windows/macOS/Linux) |
| Data Output | Bx, By, Bz, uncalibrated temperature, high-resolution timestamp |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ASN9000 |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AXR |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AXR |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito 30PX |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Density Range | 0 to 2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 5–35 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Compensation | Yes, user-selectable coefficient |
| Sample Types | Liquids and low-viscosity solutions |
| Compliance | ASTM D7777, ISO 12185, USP <841>, GLP/GMP-ready data logging |
| Data Storage | Up to 1100 measurements with timestamp, sample ID, temperature correction factor, instrument ID |
| Interface | Infrared (IR), RS232 via optional IR/RS232 converter (P/N 51325006) |
| Display | Backlit dot-matrix LCD with icon-based navigation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / Densito Pro |
| Density Measurement Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 0–50.0 °C |
| Minimum Sample Volume | 2 mL |
| Instrument Type | Portable Digital Density Meter (Oscillating U-tube Principle) |
| Application Scope | Liquid Density Measurement for QC/QA in Lab, Field, and Production Environments |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito |
| Instrument Type | Portable Digital Density Meter |
| Sample Type | Solids and Liquids |
| Density Range | 0.000–3.000 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Operating Temperature Range | −10 °C to +50 °C |
| Measurement Units | g/cm³, g/mL, kg/m³, °Brix, API, °Baumé, % ethanol (v/v), % H₂SO₄, US/UK Proof, Plato, specific gravity, user-defined concentration scales |
| Data Storage Capacity | 1100 measurements with sample ID, temperature correction factor, instrument ID, timestamp, and unit |
| Display | Full-color backlit LCD |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, optional printer output, compatible with EasyDirect PC software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4 / D5 / D6 |
| Instrument Type | Benchtop Laboratory Density Meter |
| Sample Type | Solid and Liquid |
| Temperature Range | 0–95 °C (32–203 °F) |
| Repeatability | ±0.00005 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.0001 / ±0.00005 / ±0.000005 g/cm³ (model-dependent) |
| Temperature Accuracy | ±0.03 / ±0.02 / ±0.01 °C (model-dependent) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4/D5/D6 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Sample Type | Liquids and Low-Viscosity Solutions |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 0 °C to 95 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | 21 CFR Part 11 Ready (with LabX software), GLP/GMP Audit Trail Capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / DensitoPro |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Sample Temperature Range | 0–50 °C |
| Ambient Temperature Range | Densito: −10–50 °C |
| DensitoPro | 0–50 °C |
| Data Storage Capacity | 1,100 results |
| Supported Units | Density, Specific Gravity, Brix, API Gravity, Baumé, Ethanol (% v/v), H₂SO₄ Concentration, US/UK Proof, Plato, User-Defined Concentrations |
| Display | Full-color backlit LCD |
| Languages | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, Bluetooth (DensitoPro), RFID/Barcode Reader (DensitoPro only) |
| Software Integration | EasyDirect PC Software |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready data export |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Model | DHS/L Series |
| Detection Principle | High-Frequency Electromagnetic Induction |
| IP Rating | IP69K (HDS), IP65 (L Series) |
| Construction | 316L Stainless Steel Wetted Parts |
| Compatible Media | Liquids, Slurries, Pastes, Emulsions |
| Integration Interface | 4–20 mA, Ethernet/IP, PROFIBUS, Modbus TCP |
| Software Platform | METTLER TOLEDO Profile/Signature Suite |
| Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature), HACCP, ISO 22000, IFS Food, BRCGS, EC 852/2004 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DM40 |
| Density Measurement Range | 0.0000–3.0000 g/cm³ |
| Density Repeatability (SD, n=10) | 0.00005 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (typical) |
| Temperature Control Range | 0–91 °C |
| Minimum Sample Volume | 1 mL |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (vibrating tube) densitometry |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 270, DIN 51757 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861e |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Tan δ Range | 0.0001–100 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA1 |
| Temperature Range | −190 °C to 600 °C |
| Force Range | ±0.001 N to ±10 N |
| Displacement Range | ±1 mm |
| Frequency Range | 0.001 Hz to 300 Hz |
| Stiffness Range | 50 N/m to 10⁵ N/m |
| Tan δ Range | 0.0001 to 50 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 / DP90 |
| Temperature Range | RT to 400 °C (DP70), –20 to 400 °C (DP90) |
| Accuracy | ±0.4 °C (–20 to 30 °C), ±0.2 °C (30 to 200 °C), ±0.5 °C (200 °C to max) |
| Heating Rate | 0.1–20 °C/min |
| Compliance | ASTM D3104, D3461, D36, D6089 |
| Data Output | PDF, CSV, video export, LIMS-compatible CSV |
| Sample Carrier | Standardized disposable cups per ASTM/DIN/Ph. Eur. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 1 |
| Temperature Range | –150 °C to 700 °C |
| Sensor Configuration | 56- or 120-pair star-arranged thermocouples |
| Optional Modules | UV-DSC, HP-DSC (up to 100 bar / down to 10 mbar), DSC-Microscopy System |
| Autosampler Capacity | Up to 34 samples |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 2 |
| Temperature Range | –150 to 700 °C |
| Heating/Cooling Rate | 0.02 to 300 K/min |
| Sensor Type | FRS 6 (56 thermocouples) or HSS8 (120 thermocouples) |
| Autosampler Capacity | 34 positions |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 / DSC 3+ |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.05 °C |
| Heating/Cooling Rate | 0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 Excellence Series |
| Temperature Range | −150 °C to 700 °C |
| Data Acquisition Rate | Up to 50 data points per second |
| Sensor Type | MultiSTARe™ DSC sensor with 56 or 120 thermocouple pairs (Au/Au-Pd) |
| Cooling Rate | 0.02 K/min to 50 K/min |
| Calibration | FlexCal® (fully automated, multi-point, reference-based) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3+ |
| Temperature Range | -150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min |
| Sensor Options | FRS 6+ (56 thermocouples) or HSS 9+ (120 thermocouples) |
| TAWN Resolution (FRS/HSS) | 0.12/0.2 °C |
| TAWN Sensitivity (FRS/HSS) | 11.9/56 µW/°C |
| Indium Response Ratio (FRS) | >155 mW/°C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 5+ |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Capacity | Multi-sample (automated) |
| Operating Modes | Power Compensation & Heat Flux (FlexMode™) |
| Sensor Configuration | MultiStar™ sensor with 136 thermocouple pairs |
| Calibration | FlexCal™ automated calibration |
| Atmosphere Control | Integrated gas-purged crucible chamber |
| Modular Architecture | Yes |