Physical Property Testing Instruments
Filter
Showing 6631–6660 of 12514 results
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Model | HPP110 / HPP260 / HPP750 |
| Temperature Range (no lighting) | 0 °C to +70 °C |
| Temperature Range (with LED lighting) | +10 °C to +40 °C |
| Humidity Range (no lighting) | 10–90 % RH |
| Humidity Range (with LED lighting) | 10–85 % RH |
| Temperature Setting Resolution | 0.1 K |
| Humidity Setting Resolution | 1 % RH |
| Internal Volume | 108 L / 256 L / 749 L |
| Power Consumption (230 V, 50 Hz) | 350 W / 525 W / 1050 W |
| LED Lighting Options | 5500 K (cool white) or 2700 K (warm white), 10% intensity steps |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | HPP110 |
| Instrument Type | Upright Climate Chamber |
| Internal Volume | 108 L |
| External Dimensions (W×H×D) | 710 × 760 × 620 mm (excluding handle) |
| Internal Dimensions (W×H×D) | 560 × 480 × 400 mm |
| Standard Shelving | 2 adjustable perforated stainless steel shelves |
| Temperature Range (with illumination) | 10–40 °C |
| Temperature Range (without illumination) | 0–70 °C |
| Temperature Uniformity (per DIN 12 880 | 2007-05): ≤ ±0.4 °C at 10 °C and 37 °C |
| Temperature Stability (per DIN 12 880 | 2007-05): ≤ ±0.1 °C over time |
| Humidity Range | 10–90 %RH (10–85 %RH with illumination active) |
| Humidity Control | Capacitive sensor + microprocessor-controlled humidification/dehumidification via distilled water recirculation pump and thermally blocked bacterial barrier |
| Illumination | Dual-mode tunable LED lighting — Mode 1: Cool white (5500 K), Mode 2: Mixed cool + warm white (2700 K) |
| Max irradiance | 10,000 lux at 10 cm distance |
| Temperature & Humidity Monitoring | PT100 Class A four-wire sensor (redundant fault detection), capacitive RH sensor with auto-diagnostic system |
| Safety Systems | Triple-level overtemperature protection (including Pt100-based monitoring per Protection Class 3.3), ASF (Automatic Safety Function), relay-based heater cutoff, audible/visual alarms for T/RH deviation, empty water tank, or sensor failure |
| Data Logging | Internal 1024 KB memory |
| Programming | Up to 40-stage weekly program (MEMoryCard XL compatible) |
| Connectivity | Parallel port for PCL3-compatible inkjet printers (USB via optional converter) |
| Calibration | On-device 3-point temperature / 2-point humidity calibration (20 %RH, 90 %RH) |
| Display Language Options | German, English, Spanish, French, Italian |
| Power Supply | 230 V ±10 %, 50/60 Hz |
| Max Power Consumption (heating/cooling + lighting) | 400 W |
| Net Weight | 66 kg |
| Environmental Technology | Thermoelectric (Peltier) cooling, LED illumination — zero refrigerants, low heat load, high energy efficiency |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | HPP260 |
| Instrument Type | Upright Environmental Test Chamber |
| Internal Volume | 256 L |
| Internal Dimensions (W×H×D) | 640 × 800 × 500 mm |
| External Dimensions (W×H×D) | 824 × 1186 × 774 mm |
| Weight (Net/Gross) | 103 / 121 kg |
| Temperature Range (Dark) | 0–70 °C |
| Temperature Range (Illuminated) | 10–40 °C |
| Temperature Setpoint Accuracy | ±0.1 K |
| Humidity Range (Dark) | 10–90 %RH |
| Humidity Range (Illuminated) | 10–85 %RH |
| Humidity Setpoint Accuracy | ±1 %RH |
| Standard Shelves | 2 pcs (Max. 9) |
| Construction | AISI 304 Stainless Steel (1.4301) Interior |
| Cooling Technology | Peltier-based Thermoelectric System |
| Compliance | ICH Q1A(R3), RoHS, GLP-ready |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | HPP750 |
| Instrument Type | Upright Environmental Test Chamber |
| Temperature Range | 0–70 °C (without illumination) |
| Humidity Range | 10–90 %RH (without illumination) |
| Temperature Uniformity | ±0.5 °C |
| Humidity Deviation | ±2 %RH |
| Heating Rate | 5 °C/min |
| Internal Volume | 749 L |
| Chamber Dimensions (W×H×D) | 1040 × 1200 × 600 mm |
| External Dimensions (W×H×D) | 1224 × 1726 × 874 mm |
| Standard Shelves | 2 (max. 14) |
| Net Weight | 234 kg |
| Gross Weight | 284 kg |
| Compliance | ICH Q1A, RoHS, GLP-ready |
| Control System | P-type PID controller with 0.1 K temperature setpoint resolution and 1 %RH humidity setpoint resolution |
| Brand | Memmert |
|---|---|
| Model | HPP110eco / HPP260eco / HPP410eco / HPP750eco |
| Type | Upright Temperature & Humidity Controlled Chamber |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–90 % RH |
| Cooling Technology | Solid-State Peltier |
| Energy Reduction vs. Compressor-Based Systems | Up to 90 % |
| Compliance | ICH Q1A, ISO 14644-1 (Class 8), GLP/GMP-Compatible Operation |
| Calibration Points | User-Selectable (3 Temp + 3 RH) |
| Optional Illumination | Tunable LED Light Module (2700 K / 6500 K, 1 % dimming resolution) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Model | HPPeco |
| Chamber Type | Upright |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–90 % RH |
| Voltage Options | 115 V, 50/60 Hz |
| Standard Accessories | Reinforced chamber interior with two reinforced shelves (grid or perforated), dual-color white LED illumination (CCT-adjustable) |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | ICH |
| Chamber Construction | Stainless Steel (1.4301 / ASTM 304) Inner Chamber |
| Temperature Control | Air-jacketed Heating & Cooling System |
| Humidity Range | 10–80% RH (±1.5% RH typical accuracy) |
| Temperature Range | 0°C to 70°C (±0.1°C stability at 25°C) |
| Forced Convection | Adjustable in 10% increments (0–100%) |
| CO₂ Control Module (Optional) | Digital IR-based, auto-zeroing, with frost protection, alarm, and barometric pressure compensation |
| Illumination | ICH Q1B Option 2 compliant |
| Compliance | Designed for IQ/OQ/PQ validation per GMP/GLP requirements |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Manufacturer | MEMMERT GmbH & Co. KG |
| Chamber Type | Upright Vertical |
| Models | ICH 110 / ICH 260 / ICH 750 |
| Temperature Range | 0–60 °C |
| Humidity Range | 10–80 % RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ≤ ±1 °C |
| Humidity Uniformity | ≤ ±3 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Inner Chamber Dimensions | Model-Dependent (e.g., ICH 110: W 420 × D 420 × H 620 mm) |
| Refrigerant | Natural CO₂ (R744) in ICHeco variants |
| Light Module (ICH L) | 8000 lux, D65 daylight simulation (6500 K) + UV-A (320–400 nm) |
| CO₂ Control Module (Optional) | Digital NDIR sensor with auto-zero, frost protection, alarm, and barometric pressure compensation |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | ICHL 110 / ICHL 260 / ICHL 750 |
| Configuration | Upright Vertical Chamber |
| Temperature Range | 0–60 °C |
| Humidity Range | 10–80 %RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Stability | ≤ ±1 °C |
| Humidity Uniformity | ≤ ±3 %RH |
| Humidity Stability | ≤ ±3 %RH |
| Heating Rate | 1.0–3.0 °C/min |
| Internal Chamber Dimensions | Varies by model (110 L / 260 L / 750 L) |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Type | Benchtop Temperature-Controlled Incubator |
| Models | ICP 110 / 260 / 450 / 750 |
| Temperature Range | −12 °C to +60 °C |
| Chamber Volume | 110 L / 260 L / 450 L / 750 L (model-dependent) |
| Heating/Cooling System | Compressor-based with Air-Jacket Thermal Management |
| Air Circulation | Adjustable fan speed (10–100% in 10% increments) |
| Illumination Option | Programmable Day/Night Cycle with Simulated Sunlight Spectrum |
| Energy-Saving Mode | Adaptive Defrost & Load-Responsive Cooling |
| Noise Level | ≤45 dB(A) at 1 m (typical, full load, 25 °C ambient) |
| Compliance | CE, ISO 13485 (manufacturing), EN 61000-6-3 (EMC), EN 61000-6-2 (immunity), VDI/VDE 2655 Blatt 2 (incubator performance testing) |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | STABILITY-FITOCLIMA 12000 |
| Internal Dimensions (D×W×H) | 376 × 222.5 × 261 cm |
| Temperature Range | 15°C to 45°C |
| Humidity Range | 35% to 90% rH |
| Volume | 21,500 L (nominal, based on stated dimensions) |
| Compliance | FDA 21 CFR Part 11, ICH Q1–Q5, EU GMP Annex 15, ISO 14644-1 Class 8 (optional), GLP/GMP-ready |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Imported Equipment |
| Model | STABILITY-FITOCLIMA 20000 |
| Internal Dimensions (D×W×H) | 538 × 222.5 × 261 cm |
| Temperature Range | 15°C to 45°C |
| Humidity Range | 35% to 90% rH |
| Chamber Volume | Up to 20,000 L (custom configurations available from 5,000 L to 25,000 L) |
| Compliance | FDA 21 CFR Part 11, ICH Q1–Q5, EU GMP Annex 15, ISO 14644-1 Class 8 (optional), GLP/GMP-ready |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | STABILITY-FITOCLIMA 25000 |
| Internal Dimensions (D×W×H) | 380 × 382.5 × 261 cm |
| Temperature Range | 15 °C to 45 °C |
| Humidity Range | 35 % to 90 % rH |
| Volume | 25,000 L |
| Compliance | FDA 21 CFR Part 11 (GAMP 5), ICH Q1–Q5, ISO 17025, GMP Annex 15, GLP |
| Brand | MEMMERT |
|---|---|
| Origin | Germany |
| Model | TTC256 |
| Internal Volume | 256 L |
| Temperature Range | −42 °C to +190 °C |
| Heating Rate (IEC 60068-3-5) | 10 K/min (avg.) |
| Cooling Rate (IEC 60068-3-5) | 6 K/min (avg.) |
| Temp. Uniformity (setpoint-dependent) | ±0.5 K to ±2 K |
| Temp. Stability (setpoint-dependent) | ±0.2 K to ±0.5 K |
| Humidity Range (optional) | 10–98 % RH |
| Humidity Sensor | Capacitive, digital display with auto-diagnosis |
| Humidity Control | Integrated steam humidification & refrigeration-based dehumidification |
| Water Supply | Dual 10 L distilled water tanks with auto-switching |
| Dimensions (W×H×D, mm) | 898 × 1730 × 1100 (external) |
| Construction | Stainless steel interior |
| Accessories | Lockable castors, 80 mm right-side access port with plug, Pt100 Class A 4-wire temperature sensor, dual-stage overtemperature protection (electronic + mechanical), audible/visual alarms for door open, temp. deviation, empty water tank, and sensor fault |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 17-56 |
| Pricing | Available Upon Request |
| Brand | Buchel BV |
|---|---|
| Origin | Netherlands |
| Model | 17-56 |
| Force Range | 0–5000 N |
| Travel Distance | 4–78 mm |
| Test Speed | 5–50 mm/min |
| Return Speed | ±100 mm/min |
| Units | N, lb, N/m, lb/in, kPa, lb/ft², lb/in², kN/m |
| Compliance | ISO 12192, ISO 7263, ISO 3037, ISO 13821, ISO 3035, TAPPI T822, T809, T843, T821, T811, T823, T838, T839, T825, T829, DIN 53134, DIN 53149, FEFCO No. 6/8/11, APPITA/AS 1301.407s/429s/434s/430s/444s, PPITA/AS 1301.429s |
| Brand | Buchel BV |
|---|---|
| Origin | Netherlands |
| Model | 84-56 Horizontal Tensile Strength Tester |
| Accuracy | ±0.5% |
| Test Speed Range | 10–200 mm/min |
| Clamping Length | 50–180 mm |
| Sample Width Options | 15, 25, 50, 75 mm |
| Compliant Standards | ISO 12625-4/5, TAPPI T-494, GB/T 12914-2008, BS EN ISO 1924-2/3, DIN 53112, JIS P8113, AS/NZS 1301.448, SCAN P38, CPPA D34 |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Optical Airborne Particle Counter System |
| Model | MET ONE FMS |
| Instrument Category | Optical Particle Counter |
| Compliance | ISO 14644-1, ISO 21501-4, FDA 21 CFR Part 11, EU GMP Annex 1 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Spectral Range | 295–450 nm |
| Irradiance Control | Yes |
| Cooling Method | Air-cooled |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, IEC 61215 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,200 (FOB) |
| Spectral Range | 295–450 nm |
| Light Source | Air-Cooled Metal Halide Lamps |
| Filter System | 3-mm Equivalent Solar UV/Visible Transmission Filter |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, IEC 61215 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illumination), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance Spectrum | 295–450 nm |
| Spectral Match | Equivalent to terrestrial solar radiation filtered through 3 mm borosilicate glass |
| Illumination Uniformity | ≥90 % across specimen plane |
| Sample Tray Dimensions | 500 × 400 mm |
| Illumination Geometry | Top-mounted lamp with reflective direct irradiation |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Model | CDM-M |
| Maximum Energy | 100+ kJ |
| Default Energy | 4 kJ |
| Modular Energy Block | 4 kJ |
| Peak Voltage | 3 kV |
| Interface | RS232 |
| Control Architecture | High-precision programmable controller |
| Compliance | Designed for industrial integration per IEC 61000-4 electromagnetic compatibility standards |
| Cooling | Forced-air or optional liquid cooling |
| Pulse Rise Time | <100 µs (typical, dependent on coil inductance and load) |
| Peak Current Capability | Up to 50 kA (custom configurations) |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoPulse-BI |
| Pricing | Upon Request |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Model | HyMAC |
| Frequency Range | 5–2500 Hz |
| Output Power | 1200 VA (optional 3 kVA) |
| Maximum Field Strength | 10 kA/m or 1.7 T |
| Measurement Outputs | Hc, Br, Bm, Hm, Core Loss, Permeability, Eddy Current Loss, Hysteresis Loss |
| Operating Modes | Rapid Prediction Mode, Fixed-Field Mode, Swept-Field Mode |
| Compliance | IEC 60404-2, IEC 60404-3, IEC 60404-6 |
| Sample Fixtures | Epstein frame, Single Sheet Tester (SST), Toroidal core fixture, Yoke-based clamping systems |
| Software Interface | Windows-native GUI with real-time waveform display, automated parameter extraction, and export to CSV/Excel |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Model | HyMPulse |
| Measurement Principle | Pulsed-field magnetization with four-quadrant hysteresis loop acquisition |
| Maximum Field | >16 T |
| Energy Storage Capacity | 28 kJ (expandable) |
| Standard Measurement Coil | 6.5 T, 50 mm bore diameter |
| Sample Temperature Range | 20–180 °C |
| Software Platform | Windows-based proprietary control and analysis suite |
| Output Parameters | Br, HcB, HcJ, Hknee, (BH)max, Hmax |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Distributor Type | General Distributor |
| Import Status | Imported |
| Cooling Options | Natural Convection, Forced Air, Liquid Cooling |
| Design Methodology | CAD-Based Mechanical Design & Finite Element Analysis (FEA) for Magnetic Flux and Structural Optimization |
| Compliance Framework | Designed for integration with industrial magnetizing power supplies compliant with IEC 61000-4 series EMC standards and ISO 9001-certified manufacturing processes |
| Packaging | Custom Protective Enclosure for Transit and Storage |
| Reusability | High-cycle mechanical durability with precision-machined ferromagnetic pole pieces and non-magnetic structural housing |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC1 |
| Heating Rate | up to 2,400,000 K/min |
| Cooling Rate | up to 240,000 K/min |
| Sensor Type | UFS1 MEMS-based chip sensor with 16 thermocouple pairs (8 on sample side, 8 on reference side) |
| Time Constant | ~1 ms |
| Measurement Principle | Dynamic power-compensated differential scanning calorimetry |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+ 300 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –150 °C to +500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | ±150 N (peak-to-peak: 300 N) |
| Displacement Range | ±6 mm (peak-to-peak: 12 mm) |
| Frequency Range | 1×10⁻⁵ Hz to 200 Hz (up to 1000 Hz with optional high-frequency module) |
| Minimum Detectable Force | 0.01 N |
| Minimum Detectable Displacement | 0.05 µm |
| Stiffness Measurement Span | >7 decades (250 Pa to 3×10¹² Pa) |
| Environmental Control Options | O₂ concentration control (10 ppm–20% vol), cryogenic cooling (LN₂ or air-cooled to –150 °C) |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+1000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | −500 N to +500 N (peak-to-peak: 1000 N) |
| Displacement Range | ±6 mm (peak-to-peak: 12 mm) |
| Frequency Range | 1×10⁻⁵ Hz to 200 Hz (optional up to 1000 Hz) |
| Minimum Detectable Force | 0.01 N |
| Minimum Detectable Displacement | 0.1 µm |
| Maximum Measurable Modulus | 3×10¹² Pa |
| Dynamic Modulus Range | 6 decades |
| Environmental Control Options | O₂ concentration control (10 ppm–20% O₂), forced-air cooling (−70 °C), liquid nitrogen cooling (−150 °C) |