Physical Property Testing Instruments
Filter
Showing 6781–6810 of 12511 results
| Brand | Micromeritics |
|---|---|
| Origin | United Kingdom |
| Model | FT4 |
| Instrument Type | Multifunctional Powder Flowability Tester |
| Measurable Powder Parameters | Flow Function, Flow Energy, Aeration Energy, Consolidation Energy, Compressibility, Permeability, Wall Friction Angle |
| Maximum Sample Vessel Capacity | 160 mL |
| Minimum Sample Volume | 1 mL (with optional mini shear cell) / 10 mL (standard) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | Gemini VII 2390 Series |
| Analysis Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 1 |
| Specific Surface Area Range | 0.01 m²/g to unlimited |
| Pressure Range | 0–1000 mmHg |
| Measurement Theory | Gas Adsorption (BET, Langmuir, t-Plot, HK, BJH) |
| Software Options | Keypad Embedded Firmware, Gemini Windows Software, FDA 21 CFR Part 11-Compliant Confirm Software |
| Dual-Mode Operation | Standalone Keypad or PC-Controlled |
| Compliance | ASTM D3663, ISO 9277, USP <846>, GLP/GMP-ready audit trail (Confirm version) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | Gemini VII 2390 Series |
| Analysis Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 1 |
| Specific Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pressure Range | 0–1000 mmHg |
| Adsorptive Gas | N₂ (optimized for liquid nitrogen bath), He, Ar, O₂, CO₂, CH₄, C₄H₁₀ |
| Relative Pressure (P/P₀) Range | 0–1.0 (adsorption only) |
| P/P₀ Resolution | <10⁻⁴ |
| Pressure Resolution | <0.1 mmHg |
| Sensor Accuracy & Linearity | ±0.5% of full scale |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–80% RH (non-condensing) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | GeoPyc 1365 |
| Instrument Type | Benchtop Envelope Density Analyzer |
| Sample Form | Solids (powders, granules, irregular solids, tablets, foams) |
| Measurement Principle | Solid displacement using Dry Flo™ quasi-fluid medium |
| Envelope Volume Range | 0.3–25 cm³ (via interchangeable sample cups) |
| Density Accuracy | <0.15% deviation vs. ASTM D1895, D6342, D7481 |
| Operating Temperature | 15–35 °C |
| Minimum Sample Requirement | ≥25% of selected cup volume |
| Compliance | ASTM D1895 (Type A), D6342, D7481, ISO 697, USP <699>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Optional T.A.P. Density Module | Programmable consolidation force (0.5–10 N), stepwise compression cycles, real-time force & displacement monitoring |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | HPVA-II |
| Measurement Principle | Static Volumetric Method (High-Pressure Capacity Technique) |
| Temperature Range | 30 K to 500 °C |
| Pressure Range | Ultra-High Vacuum (≤1×10⁻⁹ Torr) to 200 bar |
| Vacuum Level | <1×10⁻⁹ Torr |
| Compatible Gases | H₂, CH₄, CO₂, N₂, Ar, and other non-corrosive gases |
| Sample Requirement | As low as 5–50 mg |
| Sample Types | MOFs, Zeolites, Activated Carbons, Porous Polymers, Metal Hydrides, Catalyst Supports |
| Thermal Control Options | Liquid Cryogen Dewar (4 L stainless steel), External Circulating Bath, Resistive Heating Furnace, Closed-Cycle Cryocooler Integration |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SAS II 5800 |
| Measurement Range | 0.2–75 µm |
| Repeatability | ±1% RSD |
| Porosity Range | 0.2–0.9 |
| Compliance | ASTM B330-12, ASTM C721-14 |
| Display | Integrated Touchscreen Interface |
| Control Software | SAS Control Suite v5.x |
| Dimensions (H×W×L) | 55 × 50 × 38 cm |
| Weight | 28 kg |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SediGraph III Plus |
| Measurement Principle | X-ray sedimentation |
| Measurement Range | 0.1–300 µm |
| Repeatability | < 1% RSD |
| Accuracy | < 1% error vs. NIST-traceable standards |
| Analysis Time | 3–15 minutes per sample |
| Sample Volume | 50 mL dispersion |
| Compliance | ISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics) |
| Automation | Unattended analysis of up to 18 samples |
| Optional Integration | MasterTech Auto-sampler for process monitoring and cloud data export |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | TriStar II Plus 3030 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 |
| Specific Surface Area Range | 0.001 m²/g to unlimited |
| Pressure Range | 0–1000 mmHg |
| Theoretical Basis | Gas Adsorption Analysis |
| Construction | Corrosion-Resistant Stainless Steel Manifold |
| Cryogenic Duration | >40 hours with optimized Dewar design |
| Software Platform | MicroActive v4.x with Python scripting support |
| Compliance Ready | ASTM D3663, ISO 9277, ISO 15901-2, USP <846>, IUPAC 2015 recommendations |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | TriStar II Plus Series |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 |
| Surface Area Range | 0.001 m²/g to unlimited |
| Pressure Range | 0–1000 mmHg |
| Theoretical Basis | Gas Adsorption Method |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Number of Analysis Stations | 1–3 |
| Gas Options | N₂, Kr, Ar, CO₂, CH₄, C₄H₁₀ (non-corrosive) |
| Minimum Surface Area (N₂) | 0.01 m²/g |
| Minimum Surface Area (Kr) | 0.001 m²/g |
| Minimum Pore Volume | 4 × 10⁻⁶ cm³/g |
| Dewar Capacity | 2.75 L (optional 4 L) |
| Continuous Analysis Duration | up to 40 h |
| Data Points per Isotherm | up to 1000 |
| P₀ Measurement | integrated, continuous or manual input |
| Free Space Determination | measured, calculated, or user-defined |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | TriStar II Plus |
| Analysis Stations | 3 (independent) |
| Measurable Surface Area | ≥0.01 m²/g (N₂), ≥0.001 m²/g (Kr) |
| Pore Volume Detection Limit | ≥4 × 10⁻⁶ cm³/g |
| Dewar Capacity | 2.75 L (optional 4 L) |
| Continuous Operation Time | up to 40 h |
| Gas Compatibility | N₂, Ar, CO₂, C₄H₁₀, CH₄, and other non-corrosive gases |
| P₀ Measurement | continuous, manual, or in-situ |
| Data Points per Isotherm | up to 1000 |
| Software | Windows-based with SPC reporting, DFT modeling, t-plot, αₛ-plot, isosteric heat calculation, and thickness model integration |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MicronX |
| Pricing | Available Upon Request |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | AEROTRAC II |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5–2,000 µm |
| Repeatability | ≤1% |
| Measurement Time | 10–15 seconds |
| Optical Principle | Static Laser Diffraction with Full-Range Mie Theory Processing |
| Laser Source | Semiconductor Laser |
| Auto-Focusing | Yes |
| Trigger Mode | Automatic Pulse Detection |
| Software Platform | Windows-Compatible Analysis Suite |
| Optional Accessories | PD-10S Dry Spray Module, SC-13 Wet Dispersion Unit, MB-600 Motorized Translation Stage |
| Compliance | Designed for ASTM E799, ISO 13320, and USP <429> alignment |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELCAT II |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Number of Gas Inlets | 8 (Pre-treatment), 3 (Carrier), 8 (Pulse), 8 (Mixing) |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±1 °C |
| Heating Rates | 50–500 °C at 70 °C/min |
| Pressure Range | Atmospheric |
| Key Functions | TPD, TPR, TPO, TPRx, Pulse Chemisorption, Single-point BET, Breakthrough Curve Analysis |
| Gas Compatibility | He, Kr, N2, Ar, O2, H2, CO, CO2, NH3, H2O, NO, SO2, H2S, CH3OH, C2H5OH, Toluene, Benzene, and other reactive/volatile species |
| Thermal Conductivity Detector (TCD) | Quad-wire configuration with W–Re or gold-plated tungsten filaments |
| resolution | 1 μV |
| Mass Flow Controllers (MFCs) | 3–4 units |
| Sample Volume Capacity | 0–1 cm³ |
| Pulse Loop Volumes | 0.3 cm³, 1 cm³, or custom |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BELMASS II |
| Instrument Type | Chemisorption Analyzer with Integrated Online MS Detection |
| Gas Inlet Ports | Up to 16 |
| Temperature Stability | ±0.001 °C |
| Supported Techniques | TPD, TPR, TPS, Pulse Titration, BET Surface Area Analysis (via coupled gas dosing) |
| Mass Range | 1–200 amu |
| Detector | Faraday Cup / Continuous Dynode Electron Multiplier (C-SEM) |
| Minimum Detectable Concentration | <1 ppm (gas-dependent) |
| Scan Speed Options | Auto, 0.01–10 sec per amu (selectable) |
| Detection Channels | Up to 16 simultaneous mass channels |
| Sample Interface | Heated capillary transfer line (up to 300 °C), integrated dry scroll pump |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Model | BELPORE Series |
| Measurement Volume Range | 0.5–2 cm³ |
| Pressure Range | Vacuum to 414 MPa |
| Volume Measurement Accuracy | Better than 1% F.S. |
| Pressure Measurement Accuracy | Better than 0.1% F.S. |
| Maximum Data Points | 10,000 (intrusion) + 10,000 (extrusion) |
| Certified | CE, ISO 9001 |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELPYCNO L |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory Analyzer |
| Sample Type | Solids, Powders, Pastes, Liquids |
| Measurement Principle | Gas Displacement Pycnometry (Helium-Based) |
| Pressure Range | Vacuum to 2.5 bar |
| Temperature Control Range | 14–40 °C (Peltier-Driven, Optional) |
| Temperature Stability | ±0.01 °C |
| Density Accuracy | ±0.01% |
| Density Repeatability | ±0.01% |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Standard Sample Cell Volumes | 20 mL, 40 mL, 60 mL |
| Optional Sample Cell Volumes | 4 mL, 100 mL |
| Reference Cell Configuration | Three Integrated Reference Cells |
| Pressure Sensor | High-Stability Absolute Sensor (0–2.5 bar), 19-bit A/D, Drift ≤ ±0.02 mbar |
| Gas Options | He (standard), N₂, SF₆ |
| Inlet Pressure Range | 160–240 kPa (1.6–2.4 bar) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 4590, ASTM D6226-10 |
| Interface | RS-232 (COM) or USB |
| Dimensions (W×H×D) | 25 × 33 × 45 cm |
| Weight | 17 kg |
| Operating Environment | 15–30 °C, 20–80% RH |
| Power | 85–264 VAC, 50/60 Hz, 240 W |
| Brand | Microtrac |
|---|---|
| Model | BELPYCNO |
| Type | Benchtop True Density Analyzer for Solids |
| Measurement Principle | Gas Pycnometry (Helium/Nitrogen/SF₆) |
| Density Range | All Solid Materials |
| Density Accuracy | ±0.0001 g/cm³ |
| Repeatability | ±0.01% (RSD) |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Temperature Range | 15–35 °C (standard) |
| Pressure Range | Atmospheric to 150 kPa |
| Safety Features | Integrated pressure relief valve |
| Calibration Standards | Internal calibration spheres (multiple sizes) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 18857-1 |
| Software | BELPyCNOSoft v3.x with audit trail, user management, and 21 CFR Part 11 compliance options |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP HP |
| Pressure Range | Up to 20 MPa (optional: 13.5 MPa) |
| Pressure Sensor Options | 1, 1.5, 2, 3.5, 13.5, or 20 MPa (±0.08% F.S.) |
| Temperature Control Range | 4.2 K – 673 K (via liquid He/N₂ cryostats, resistive furnaces, Peltier units, and air-bath thermal management) |
| Gas Inlets | 6 total (1 He for dead-volume calibration, 1 compressed air, 4 adsorptive gases) |
| Vacuum System | Optional turbomolecular pump + vacuum gauges |
| Compliance | Built-in compressibility factor (Z) and virial coefficient correction for non-ideal gas behavior |
| Sealing | Swagelok® filter-faced ferrules (0.5 µm pore size) |
| Thermal Stability | Air-bath manifold & reference chamber (15–35 °C, ±0.1 °C) |
| Software | BELSIM™ (isotherm modeling, PCT analysis), optional BELDyna™ (kinetic modeling: concentration vs. time, effective diffusivity, mass transfer coefficients) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELSORP MAX G |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Volumetric Gas Adsorption (Dynamic & Static Mode) |
| Number of Analysis Stations | 3 or 6 |
| Operating Temperature Range | 10–35 °C |
| Storage Temperature Range | 0–50 °C |
| Temperature Control Accuracy | ±1 °C |
| Vacuum System | Dual-stage rotary vane pump, ultimate vacuum ≤1 × 10⁻³ mmHg (≤0.13 Pa) |
| Pressure Sensors | 1 Torr, 10 Torr, and 1000 Torr high-precision capacitance manometers |
| Minimum Detectable Pressure Change | <1 × 10⁻⁵ Pa |
| Free Space Calibration | AFSM™ (Automatic Free Space Measurement) patented technology |
| Isotherm Range | P/P₀ = 1 × 10⁻⁷ to 0.997 at 77 K (N₂) and 87 K (Ar) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MINI X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption (Combined with Dynamic Pre-evacuation) |
| Analysis Stations | 4 |
| Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–133.3 kPa |
| Measurement Theory | Static Volumetric Method + Advanced Free Space Monitoring (AFSM™) |
| Compliance Options | FDA 21 CFR Part 11, IQ/OQ Documentation Package Available |
| Brand | Microtrac MRB |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 Series |
| Temperature Range | Ambient to 1100 °C (furnace), –100 °C (CryoCooker), up to 150 °C (gas lines) |
| Detection | High-Linearity TCD with corrosion-resistant filament |
| Gas Control | 12 independent gas inlets, 4 precision mass flow controllers |
| Analytical Modes | Pulse chemisorption, TPR, TPD, TPO, TPRx, vapor-phase adsorption |
| Vapor Capability | Integrated steam generator for pyridine, water, benzene, etc. |
| Cooling | KwikCool rapid furnace cooling system |
| Compliance | Designed for GLP/GMP environments |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER 3D |
| Instrument Type | Dynamic |
| Measurement Parameters | Particle size (minimum size, length, mean diameter, etc.) and particle shape (aspect ratio, symmetry, sphericity, convexity, etc., compliant with ISO 9276-6) |
| Measurement Range | 20 µm to 30 mm |
| Frame Rate | Up to 250 fps (3D mode) |
| Camera System | Dual-camera (9 MP ZOOM + 5 MP BASIC) |
| Analysis Time | 2–5 minutes per sample |
| Sample Throughput | High |
| Particle Tracking | 3D trajectory reconstruction with up to 30 images per particle |
| Compliance | ISO 9276-6, ASTM E2457, GLP/GMP-ready with optional 21 CFR Part 11 Audit Trail Manager |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Model | Camsizer M1 |
| Measurement Principle | Static Image Analysis (ISO 13322-1) |
| Measurement Range | 0.5 µm – 1500 µm |
| Camera Resolution | 18.1 MP color sensor |
| Maximum Digital Resolution | 35 nm |
| Objective Lenses | 2.5×, 5×, 10×, 20×, 50× (standard) |
| Sample Stage Positioning Accuracy | <3 µm |
| Repeatability | ±1 µm |
| Dispersion Methods | Dry air dispersion (M-Jet module) and wet dispersion |
| Light Sources | Transmitted light, reflected light, and combined illumination |
| Particle Morphology Parameters | Aspect Ratio, Compactness, Convexity, Roundness |
| Maximum Supported Objectives | 6 |
| Dimensions (Analyzer) | 450 mm × 540 mm × 550 mm |
| Weight (Analyzer) | 45 kg |
| Power Supply | 100–230 V / 50–60 Hz |
| Interface | USB 2.0 (control), USB 3.0 (camera) |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE |
| Instrument Type | In-Line / Dynamic |
| Measurement Parameters | Particle size (minimum size, length, equivalent spherical diameter, D10/D50/D90), shape descriptors (aspect ratio, symmetry, sphericity, convexity, roughness, transparency, density-related morphology), compliant with ISO 9276-6 |
| Measurement Range | 22 µm – 35 mm |
| Imaging Speed | Up to 100 high-resolution images per second |
| Output | 32 morphological parameters per analysis cycle |
| Design | Explosion-proof (optional ATEX/IECEx certification), compact footprint, integrated auto-cleaning mechanism, compatible with third-party sample transfer systems (e.g., pneumatic conveyors, screw feeders, belt samplers) |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE |
| Application Sector | Pharmaceutical Manufacturing |
| Instrument Type | Dynamic In-line Analyzer |
| Measurement Range | 22 µm – 35 mm |
| Measured Parameters | 32 morphological parameters including dimensional, shape, surface roughness, density, transparency, and true 3D characterization |
| Imaging Speed | Up to 100 high-resolution images per second |
| Design | Compact, explosion-proof (ATEX/IECEx compliant), integrated auto-cleaning mechanism |
| Compliance | Designed for GMP environments with audit-trail-ready data handling |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE XL |
| Instrument Type | Dynamic Online Analyzer |
| Measurement Range | 0.8 µm to 8 mm (standard) |
| Measured Parameters | Particle size distribution (D10, D50, D90, length, width, equivalent circular diameter, Feret diameters), particle shape descriptors (aspect ratio, symmetry, sphericity, convexity, solidity, roundness, roughness) per ISO 9276-6 |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE XL |
| Application Field | Pharmaceutical Manufacturing |
| Instrument Type | Dynamic Inline Analyzer |
| Measurement Range | 160 µm – 135 mm |
| Measured Parameters | Particle Dimensions, Shape Metrics (e.g., Aspect Ratio, Circularity, Convexity), Surface Roughness, Density Estimation, Transparency Classification, 3D Morphological Reconstruction |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer | RETSCH TECHNOLOGY & JENOPTIK JENA (formerly ZEISS) |
| Model | CAMSIZER P4 |
| Measurement Principle | Dynamic Image Analysis (DIA) |
| Measurement Range | 10 µm – 30 mm |
| Sample Type | Dry, free-flowing powders and granules |
| Dispersion Method | Vibratory dry dispersion |
| Optical System | Dual high-resolution lenses (1.3 MP per channel) |
| Image Acquisition Rate | 60 frames/s |
| Pixel Resolution per Image | >780,000 pixels |
| Compliance | ISO 13322-2, CE, FDA 21 CFR Part 11, GLP/GMP-ready audit trail |
| Dimensions (H×W×D) | 650 × 850 × 350 mm |
| Weight | 40 kg (without PC) |
| Analysis Time | 2–3 min (sample-dependent) |
| Key Output Parameters | Equivalent circular diameter (ECD), Feret diameter, aspect ratio, circularity, convexity, solidity, transparency index, particle count, size distribution (volume-, number-, surface-weighted), shape distribution histograms |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Model | CAMSIZER X2 |
| Measurement Principle | Dynamic Image Analysis (ISO 13322-2) |
| Measurement Range | 0.8 µm to 8 mm (overall) |
| Dual CCD Imaging System | 2 lenses (blue reference lens + red high-magnification lens) |
| Dispersion Modes | Dry (free-fall & pneumatic) and Wet (liquid suspension) |
| Sample Throughput | <20 mg – 500 g per measurement |
| Frame Rate | >300 fps |
| Image Resolution | ~4.2 MPixel per frame |
| Pixel Resolution | 0.8 µm/pixel |
| Measurement Area | ~20 × 20 mm |
| Shape Parameters | Aspect Ratio, Circularity, Convexity, Symmetry, Compactness, Sphericity (per ISO 9276-6) |
| Size Parameters | Equivalent Circle Diameter, Length, Width, Feret Diameter, Minimum Bounding Rectangle, etc. |
| Measurement Time | 1–3 minutes |
| Dimensions (W×H×D) | 850 × 580 × 570 mm |
| Weight (Analyzer Unit) | ~50 kg |
| Operating PC | Integrated quad-core Windows 10 system with dedicated hardware interface card, monitor, keyboard, mouse, and Microtrac’s proprietary evaluation software |