| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-202 |
| Pressure Resolution | 0.005 MPa |
| Maximum Operating Pressure | 0.6 MPa |
| Power Source | Compressed Air or Nitrogen |
| Weight | 5 kg |
| Measurement Principle | Bubble Point Method (Based on H. Bechhold’s Theory) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRF-1000/5-H |
| Load Range | 1–10 kN (lever ratio 1:30) |
| Load Accuracy | ±1% of indicated value |
| Rotational Speed | 0–1500 rpm (±3%, 50 Hz) |
| Max Test Temperature | 200 °C |
| Temp. Stability | ±2 °C |
| Heating Power | 480 W (dual 240 W elements) |
| Specimen | Ø60 × 15 mm disc |
| Steel Balls | Ø3/8 inch (3 pcs per test) |
| Vibration Detection Range | 0.03–3 G, 5 Hz–10 kHz |
| Counter Resolution | 9-digit cumulative rotation count |
| Cooling Water Requirement | 10 L/min at ≤0.2 MPa, inlet temp ≤30 °C |
| Net Weight | ~1200 kg (excl. dead weights) |
| Power Supply | 3P AC 380 V, 50 Hz, 30 A |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HP-1000-T |
| Packing Material | Helipack No.2 (SUS316) |
| Theoretical Plates | 35 |
| Hold-up Volume | 30–50 mL |
| Max. Throughput | ~1.4 L/h (n-heptane) |
| Feed Capacity | 200–800 mL |
| Pressure Drop | ≤1.463 kPa |
| Distillation Column | Packed, φ22×1000 mm, Vacuum-Jacketed |
| Distillation Flask Options | 500 mL and 1 L |
| Heating Mantle | AC 100 V, 500 W / 300 V, 1000 W / 450 V |
| Reflux Ratio Timer | Sample Collection 0–999 s, Reflux Duration 0–999 s |
| Operating Pressure Range | Full vacuum to atmospheric |
| Temperature Range | Ambient to 300 °C |
| Power Supply | AC 100 V, 0.6 kVA |
| Dimensions | 650(W) × 450(D) × 2000(H) mm |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Manufacturer | DKK TOA Corporation |
| Model | TTT-710 |
| Application | Automated Electrode Handling & Multi-Sample Conditioning for Benchtop Conductivity/Resistivity Meters |
| Optional Accessories | Pure Water Spray Rinse, Chemical Rinse Module, Air Blow Dry, Front-Mounted Electrode Cleaning & Storage Compartment, External Circulating Thermostatic Bath Integration (for ISO/ASTM-compliant temperature-controlled conductivity measurements) |
| Security | User Access Control, Audit-Trail-Ready Data Integrity Protection (aligned with GLP/GMP documentation requirements) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Talliani Vacuum Stability Analyzer |
| Pricing | Upon Request |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TV4000 |
| Instrument Type | Vacuum Capillary Viscometer |
| Viscosity Range | 0.0036–20,000 Pa·s |
| Temperature Range | Ambient to 230 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 40 L |
| Bath Opening Dimensions | 260 × 240 mm |
| Vacuum Pressure Range | 30–430 mbar (negative pressure) |
| Vacuum Accuracy | ±0.5 mbar |
| Compliant Standards | ASTM D2171, SH/T 0557, IP 222, EN 12596, AASHTO T 202 |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CRY-2A / CRY-1A |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DSC30 |
| Temperature Range | Ambient to 750 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Stability | < ±0.1 µW over 30 min |
| Atmosphere Control | Dual-channel, 0–200 mL/min (0.1 mL/min resolution) |
| Cooling Speed | 550 °C → −40 °C in ≤35 min |
| Temperature Control Precision | < ±0.03 °C (isothermal), Linearity Error < 0.1 °C @ 10 °C/min |
| Sensor | Integrated NiCr/NiSi thermopile with symmetrical sample-stage electrodes |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Model | NDJ-1 / NDJ-4 |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Techcomp RJY-1P |
| Instrument Type | Static Thermomechanical Analyzer (TMA) |
| Temperature Range | Ambient to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Applied Load Range | Up to 250 g (static force) |
| Displacement Measurement Range | 0–2500 µm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | RZY-1 / RZY-2 |
| Price Range | USD 7,000 – 14,000 |
| Temperature Range | Ambient to 1400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 1–50 °C/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Model | SNB-3 / SNB-4 (Color Touchscreen) |
| Viscosity Range | 1–2,000,000 mPa·s |
| Control System | MCS-51 Microcontroller-Based Stepper Motor Drive |
| Display | Full-Color TFT Touchscreen Interface |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | SNB-E Portable Digital Rotational Viscometer |
| Pricing | Available Upon Request |
| Display | Large Backlit LCD (Dual-Language: English/Chinese) |
| Temperature Range | –50 °C to 99 °C (with optional semiconductor temperature probe) |
| Viscosity Range | 0.1–6×10⁶ mPa·s (with standard and optional “0” spindle) |
| Interface | RS232 serial port |
| Power Supply | External AC adapter |
| Compliance | GLP/GMP-ready with real-time clock and audit-trail-capable data logging |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZRY-1A & ZRY-2A |
| Price Range | USD 14,000–42,000 (FOB Shanghai) |
| Heating Rate | 0.1–50 °C/min |
| Temperature Range | Ambient to 1450 °C |
| Temperature Stability | ±1.5 °C |
| Maximum Sample Mass | 2 g |
| Atmosphere Options | Inert, Oxidizing, Static, Dynamic |
| Brand | Techne |
|---|---|
| Origin | United Kingdom |
| Model | GT-5 (1 rpm), GT-6 (10 rpm) |
| Timer Resolution | 1 min (GT-5) or 0.1 min (GT-6) |
| Maximum Timing Duration | 9999 min (GT-5) / 999.9 min (GT-6) |
| Drive Speed | 1 rpm (GT-5), 10 rpm (GT-6) |
| Detection Method | Mechanical gel-point endpoint via plunger immobilization |
| Compliance | Fully compliant with BS EN ISO 2535, ASTM D2471, and BS 2782-5 for gel time determination |
| Warranty | 3-year limited warranty including factory calibration certificate |
| Sample Holder Compatibility | Standard 22 mm, 19 mm, and 16 mm stainless-steel plungers |
| Mounting | Compatible with standard distillation flask stands (e.g., Claisen or Graham condenser supports) |
| Brand | Techne |
|---|---|
| Origin | United Kingdom |
| Model | GT-5 / GT-6 |
| Category | Rheometer/Viscometer Peripheral Service Offering |
| Compliance | ASTM D4287, ISO 1133-2 (gelation timing reference), USP <724> (for hydrogel formation kinetics) |
| Service Scope | Calibration, Repair, Legacy Unit Support |
| Brand | Teclis Scientific (France) |
|---|---|
| Origin | France |
| Model | FOAMSCAN |
| Gas Flow Range | 20–500 mL/min (mass flow controlled) |
| Stirring Speed | 500–6000 rpm (software-controlled) |
| Temperature Measurement | Pt100 sensor (ambient or optional water bath coupling) |
| Dual-Camera Imaging System | Primary foam height + secondary bubble structure |
| Modular Foaming Methods | Gas injection (via sintered glass frit), Mechanical stirring, External foam introduction |
| Automated Cleaning System | Dual-fluid (water + optional cleaning agent), integrated waste pump |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | FOAMSCAN HTMP |
| Max Operating Temperature | 120 °C |
| Max Operating Pressure | 8 bar |
| Gas Flow Range | 100–5000 mL/min |
| Imaging | USB 2.0 CCD camera (744 × 480 px, 76 fps), dual focal lengths (2.9 mm / 8.2 mm) |
| Sample Cell | triple-walled cylindrical glass tube with integrated Pt100 temperature sensor and conductivity electrodes |
| Cleaning | automated rinse system |
| Compliance | compatible with GLP/GMP workflows |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER HTHP 700 |
| Measurement Range | 0.01–1000 mN/m |
| Resolution | ±0.01 mN/m |
| Accuracy | 0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Pendant Drop or Rising Drop Shape Analysis |
| Maximum Pressure | 700 bar |
| Optical Cell Material | Sapphire Windows with Inconel 625 Housing |
| Imaging System | USB2 CCD Camera (640×480, 60 fps), Telecentric Lens (f = 55 mm), Zoom Ratio 0.5–0.05, Working Distance 98–191 mm |
| Brand | Teclis Scientific (France) |
|---|---|
| Origin | France |
| Model | TRACKER |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | 0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Method | Pendant Drop / Sessile Drop / Rising Bubble / Captive Bubble |
| Camera | Monochrome CCD, 640×480 px, up to 60 fps (optional high-speed: 600 fps) |
| Optical System | Telecentric lens + dual-intensity LED backlight |
| Sample Cell | Jacketed thermostatted cell with integrated magnetic stirrer |
| Temperature Control | Circulating bath (up to 90 °C), embedded Pt100 sensor (±0.2 °C) |
| Software | Young–Laplace fitting, dynamic interfacial rheology (dilatational modulus E', E''), contact angle hysteresis (advancing/receding), CMC determination, batch analysis, audit-trail-ready data logging |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER H |
| Measurement Range | 0.1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.5 °C |
| Measurement Method | Pendant Drop Method |
| Max Pressure | 200 bar |
| Max Temperature | 200 °C |
| Compatible Gases | Supercritical CO₂, N₂, Ar, air, CO₂ |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Dynamic Contact Angle Accuracy | ±0.1° |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER HTHP |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Pendant Drop Method |
| Maximum Pressure | 700 bar |
| Optical System | Monochrome CCD Camera (640 × 480 px), Telecentric Lens, Up to 60 fps (optional high-speed camera: 600 fps) |
| Pressure Certification | CETIM-certified pressure chamber |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | Temptronic TP04300 |
| Temperature Range | −80 °C to +225 °C |
| Cooling Medium | Non-ozone-depleting refrigerant (no LN₂ or LCO₂ required) |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Ramp Rate | <10 s from −55 °C to +125 °C and vice versa |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | IEEE-488, RS232, Ethernet |
| Display | Touchscreen Windows®-based HMI |
| Defrosting | Automatic hot-gas defrost |
| Electrostatic Protection | ESD-safe enclosure design |
| Compliance | Designed for GLP/GMP environments |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | TP04310 |
| Temperature Range | −80 °C to +225 °C |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Transition Rate | <10 s from −55 °C to +125 °C and vice versa |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interface | IEEE-488 (GPIB), RS-232 |
| Dimensions (W×D×H) | 61 × 72.4 × 108 cm |
| Weight | 236 kg |
| Operating Height Range | 69.1–130.3 cm (extendable to 81.3–188 cm) |
| Sound Pressure Level | <65 dBA |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | BENCHMASTER |
| Temperature Range | -68°C to +180°C (optional up to +200°C) |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±1.0°C |
| Temperature Deviation | ±1.0°C |
| Internal Dimensions (W×H×D) | 521 mm × 508 mm × 559 mm |
| Volume | 141 L (5.0 ft³) |
| Heating Rate | Ambient to 180°C in 32 min |
| Cooling Rate | 180°C to -65°C in 59 min |
| Humidity Range (Humidity Models) | 20–95% RH at +20°C to +85°C dry-bulb, dew point limited to 5°C |
| Humidity Control Accuracy | ±5% RH |
| Airflow | 115 CFM (3.2 m³/min) |
| Power Supply | 230 V, 1-Phase, 60 Hz, 40 A |
| Compressor Type | Cascade refrigeration system |
| Controller | Watlow F4T with INTUITION™ process control software |
| Compliance | ISO/IEC 17025 calibration available, NIST-traceable RTD sensors, GLP/GMP-ready data logging |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | C-EVO |
| Temperature Range | -70°C to 180°C |
| Humidity Range (RS/RC models) | 20–95% RH (at dry-bulb 20–85°C, dew point ≥5°C) |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Heating Rate (ambient to 180°C) | ≤35 min (typical, model-dependent) |
| Cooling Rate (-68°C to 180°C) | up to 134°C/min (model-dependent) |
| Control System | Smart 1.1™ 7-inch touchscreen PLC with Ethernet, USB, RS232/RS485 |
| Compliance | FM-certified safety architecture, NIST-traceable calibration support, ISO/IEC 17025-compliant calibration services available |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CONDITIONED |
| Temperature Range | -68°C to +180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±1.0°C |
| Temperature Deviation | ±1.0°C |
| Ramp Time | Ambient to 180°C |
| Chamber Dimensions (W×H×D) | 521 mm × 508 mm × 559 mm |
| Application | Air Thermal Aging Test Chamber |
| Classification | Environmental Test Chamber / High-Temperature Aging Chamber |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | FCR Series |
| Temperature Range | -70°C to 180°C (Single-Stage), -68°C to 180°C (Cascade) |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Ramp Rate (Cooling) | Up to 16.5°C/min (15 HP, Single-Stage, 180°C → −35°C) |
| Ramp Rate (Heating) | Up to 17.5°C/min (15 HP, Cascade, −68°C → 180°C) |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Airflow | 750–1500 CFM |
| Controller | Synergy Quattro Touchscreen (320×240 color LCD, PID with auto-tuning, dual-channel adaptation) |
| Compliance | ISO/IEC 17025 calibration support available |
| Power Supply | 208–460 VAC, 3-phase, 60 Hz |
| Cooling System | Scroll compressor (6/10/15 HP options), air- or water-cooled |
| Heating System | Nickel-chrome wire heaters (6/12/18 kW) |
| Safety | FM-approved OTP, backup thermal fuse, main disconnect with lockout, chamber vent |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | LUNAIRE CEO |
| Type | High-Temperature Aging Test Chamber |
| Temperature Range | -70°C to +180°C |
| Uniformity | ±1.0°C |
| Stability | ±0.5°C |
| Deviation | ±1.0°C |
| Ramp Time | Ambient to 180°C |
| Interior Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Working Volume Options | 8, 16, 32, and 58 ft³ |
| Humidity Range (optional) | 20–95% RH at +20°C to +85°C dry-bulb |
| Controller | Watlow F4T with INTUITION™ process control software |
| Compliance | Designed for ICH Q1–Q5, ASTM D3045, ISO 188, USP <1151>, and GLP/GMP-aligned validation protocols |