Physical Property Testing Instruments
Filter
Showing 12211–12237 of 12237 results
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK15A |
| Price Range | USD 7,000 – 14,000 |
| Surface Tension Range | 0–999.99 mN/m |
| Resolution | <0.05 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Time | 1–5 s (plate), 20–150 s (ring) |
| Interfacial Tension Capability | Yes |
| Mass Measurement Range | 0–120 g (0.1 mg resolution) |
| Power Supply | AC 220 V, 50 Hz, <150 W |
| Operating Humidity | 30–85% RH |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK2000DM |
| Measurement Range | 0–500 mN/m |
| Resolution | <0.05 mN/m |
| Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Cycle | 1–5 s (Plate), 20–150 s (Ring) |
| Temperature Control | Integrated恒温 Platform (Compatible with External Circulating Bath) |
| Sensor | Imported Japanese High-Precision Force Transducer |
| Compliance | SY/T 5370–1999 |
| Power | AC 220 V ± 22 V, 50 Hz, <150 W |
| Operating Humidity | 30–85% RH |
| Optional Modules | Magnetic Stirring, Dynamic Contact Angle, Fiber Wettability, Density & Powder Wettability Kits |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99BM |
| Measurement Range | 0–500 mN/m |
| Sensitivity | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Resolution | 0.01 mN/m |
| Methods | Du Noüy Ring & Wilhelmy Plate |
| Sample Volume (Ring) | 40–50 mL |
| Sample Volume (Plate) | 20–30 mL |
| Sampling Time (Ring) | 150–200 s |
| Sampling Time (Plate) | 1–5 s |
| Power Supply | AC 220 V ±5%, <150 W |
| Temperature Sensing Accuracy | ±0.1 °C |
| Relative Humidity Range | 30–85% RH |
| Interface | RS-232 Serial Port |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Model | JK99H4 |
| Surface Tension Range | 0–500 mN/m |
| Resolution | 0.05 mN/m |
| Temperature Control Range | Ambient to 400 °C |
| Temperature Accuracy | ±1 °C |
| Measurement Methods | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | 150–300 s (dual-speed adjustment) |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Power Consumption | <150 W |
| Operating Humidity | 30–85% RH |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M Series |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Primary Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Interval | 1–5 s (plate), 20–150 s (ring) |
| Vertical Travel | 0–50 mm (standard), up to 110 mm (optional) |
| Positioning Precision | 0.1 µm |
| Data Acquisition Rate | 0.1 Hz (0.02 Hz optional) |
| Mass Measurement Range | 0–210 g (0.1 mg standard, 0.01 mg optional) |
| Temperature Sensing Accuracy | ±0.01 °C |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Method | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | Ring: 20–150 s |
| Plate | 1–5 s |
| Force Sensor | METTLER high-precision electromagnetic balance (0.1 mg / 0.01 mg optional) |
| Vertical Stage Travel | 0–50 mm (up to 110 mm optional) |
| Stage Precision | 0.1 µm |
| Speed Control | 0.1–500 mm/min |
| Temperature Monitoring | ±0.01 °C (external probe or internal liquid sensor optional) |
| Data Acquisition Rate | 0.1 Hz (0.02 Hz optional) |
| Power Supply | AC 220 ±5 V, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Method | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | Ring method 20–150 s |
| Vertical Travel | 0–50 mm (optional 0–110 mm) |
| Positioning Precision | 0.1 µm |
| Data Acquisition Rate | 0.1 Hz (optional 0.02 Hz) |
| Temperature Sensing Precision | ±0.01 °C |
| Mass Measurement Range | 0–210 g (optional 0.01 mg resolution) |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JML04C1M |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE (Full Fluoropolymer) |
| Trough Dimensions | 200 mm × 80 mm |
| Compression Ratio | up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Vertical Dipping Speed | 0.22–45 mm/min |
| Dipping Modes | Upward/Downward |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 150 W |
| Operating Temperature | Ambient (with optional external thermostatic bath) |
| Relative Humidity | 30–85% RH |
| Software Interface | Windows-based GUI with data export, curve fitting, and post-processing capability |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JML04C2M |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE (Full Fluoropolymer) |
| Trough Dimensions | 300 mm × 100 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upward & Downward |
| Power Supply | AC 220 V ±10%, 50 Hz, 150 W Max |
| Operating Temperature | Ambient (with optional external thermostatic bath) |
| Relative Humidity | 30–85% RH |
| Compliance | ASTM D971, ISO 6295, ISO 1409, USP <721>, GLP-ready data logging |
| Brand | ZYKX |
|---|---|
| Model | JPM2012M |
| Origin | Beijing, China |
| Power Supply | 220 V AC, 300 W |
| Dimensions (W×D×H) | 690 × 310 × 480 mm |
| Gas Flow Range | 0–500 mL/min (±0.5% accuracy, max pressure 0.5 MPa) |
| Foam Height Measurement | 0–280 mm via high-resolution video imaging |
| Minimum Sample Volume | 20 mL |
| Conductivity Sensing | 5-channel electrodes, resolution 0.01 µS/cm |
| Imaging System | 1300K-pixel digital camera, 25 fps, 5 mm macro lens |
| Foam Generator Pore Size (standard) | 1.0–1.6 µm |
| Temperature Control (optional) | ambient to 90 °C via integrated heating rod |
| Data Acquisition & Control | PC-based system with pre-installed proprietary software for real-time parameter configuration, curve visualization, and Excel-exportable reports |
| Optional Add-ons | top-view industrial CCD observation module, mechanical stirring foam generation unit |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JQ03E PRO |
| Measurement Range | 0–999.999 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Sensitivity | 0.001 mN/m |
| Platinum Plate Method Sampling Time | 1–5 s |
| Platinum Ring Method Sampling Time | 50–200 s |
| CCD Imaging System | USB3.0 monochrome CMOS camera (1.3 MP, 54 fps), 0.7–4.5× continuous zoom, adjustable LED cold light source |
| Temperature Sensing Accuracy | ±0.1 °C (external probe optional) |
| Mass Measurement Range | 0–210 g (0.1 mg standard, 0.01 mg optional) |
| Vertical Stage Travel | 0–25 mm (0.1 mm standard, 1 µm optional) |
| Data Acquisition Rate | 0.1 s (0.02 s optional) |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999 |
| Brand | Zykx |
|---|---|
| Model | JS94HX |
| Origin | Beijing, China |
| Type | Microelectrophoresis Instrument |
| Price Range | USD 7,000–14,000 |
| Particle Size Range | 0.5–20 µm (aqueous dispersions) |
| Zeta Potential Range | ±3000 mV |
| Measurement Accuracy | ±5% |
| pH Operating Range | 1.6–13.0 (0.1 resolution) |
| Temperature Control | 5–35 °C (±0.1 °C) |
| Sample Volume per Test | 0.5 mL |
| Optical System | Semiconductor-based blue/green LED illumination (low-power, <100 µW), 1200× magnification |
| Electrophoretic Cell | Integrated Ag/Pt/Ti electrodes in 0.5 cm-thick borosilicate glass cuvette |
| Voltage Polarity Switching | Adjustable from 0.30 to 1.20 s |
| Data Acquisition Time | 3–10 s per measurement |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JS94K2M |
| Price Range | USD 7,000 – 14,000 |
| Zeta Potential Range | ±3000 mV |
| Measurement Accuracy | ±5% |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.1 pH unit |
| Zeta Resolution | 1 mV |
| Temperature Range | −5.0 to 105.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Optional Thermostatic Stage | −10 to 95 °C |
| Sample Volume per Measurement | 0.5 mL |
| Optical System | Semiconductor-based near-field blue/green LED illumination (λ ≈ 450–520 nm), 1200× digital magnification |
| Voltage Polarity Switching Time | Adjustable from 0.30 to 1.20 s |
| Measurement Cycle Time | 3–10 s |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 150 W |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Model | JS94KM |
| Zeta Potential Range | ±3000 mV |
| Accuracy | ±5% |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.1 pH |
| Zeta Resolution | 1 mV |
| Temperature Range | −5.0 to 105.0 °C (±0.1 °C) |
| Optional Thermostatic Stage | −10 to 95 °C |
| Sample Volume per Measurement | 0.5 mL |
| Optical System | Semiconductor-based near-field blue/green LED illumination (λ ≈ 450–520 nm), 1200× digital magnification |
| Electrophoresis Cell | Integrated Ag/Pt/Ti electrodes in 0.5 cm-thick borosilicate glass cuvette |
| Voltage Polarity Switching Time | 0.30–1.20 s (adjustable) |
| Sampling Duration | 3–10 s |
| Power Supply | 220 V AC, 50 Hz, 150 W |
| Compliance | Designed for GLP-aligned operation |
| Brand | Zykx |
|---|---|
| Model | JS94TM |
| Origin | Beijing, China |
| Type | Electrophoretic Light Scattering (ELS) Zeta Potential Analyzer |
| Particle Size Range | 0.2–50 µm (aqueous dispersions) |
| Zeta Potential Range | ±3000 mV |
| Accuracy | ±5% |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.1 pH unit |
| Zeta Resolution | 1 mV |
| Temperature Range | −5.0 to 105.0 °C (±0.1 °C) |
| Optional Thermostatic Stage | −10 to 95 °C |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 150 W |
| Sample Volume per Measurement | 0.5 mL |
| Electrode Configuration | Integrated Ag/AgCl–Pt–Ti tri-metal electrode system in precision-machined 0.5 cm-thick optical glass electrophoresis cell |
| Optical System | Near-field semiconductor illumination (blue/green LEDs, <100 µW), 1200× digital magnification, real-time dual-direction grayscale image capture |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval), anti-polarization design |
| Data Acquisition | Automated temperature-compensated ELS image sequence capture and centroid velocity calculation |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1100 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 20 × 20 mm |
| Optical Magnification | 55–320 pixel/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1100 °C (long-term), 1700 °C (short-term peak) |
| Vacuum Level | ≤5 × 10⁻⁵ Pa |
| Heating Rate | 3–5 °C/min |
| Temperature Control | 40-segment programmable PID with K/S/B-type thermocouples |
| Cooling System | Water-cooled, 1200 W capacity, 5–35 °C setpoint, 10–20 L/min flow rate |
| Imaging | Industrial color CCD (0.0005 lux sensitivity), 750 TV lines, 30 fps standard (upgradable to 60/100 fps), 300 mm working distance lens with 0.7–5× continuous zoom |
| Software Analysis Methods | Tangent, Circle Fit, Ellipse Fit, Height/Width, Sessile Drop, Automatic Image-Based Analysis |
| Data Output | EXCEL-compatible reports with embedded temperature metadata, curve-fitting results, left/right angle differentiation, and AVI video export |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1400 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 20 × 20 mm |
| Optical Magnification | 55–320 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1400 °C (long-term), 1300 °C under vacuum |
| Base Vacuum Level | ≤5 × 10⁻⁵ Pa |
| Heating Control | 40-segment programmable PID with S-type thermocouple |
| Cooling System | Water-cooled, 1200 W capacity, flow rate 10–20 L/min, pressure 1.0–1.3 bar |
| Imaging System | Industrial color CCD (0.0005 lux sensitivity, 750 TV lines), 300 mm working distance telecentric lens, 0.7–5× continuous zoom |
| Software Analysis Methods | Tangent, Circle Fit, Ellipse Fit, Height Method, Angle Method, Automatic Image Analysis |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1700 |
| Instrument Type | Benchtop High-Temperature Vacuum Contact Angle Measurement System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 30 × 20 mm |
| Optical Magnification | 0.7–5× |
| Surface/Interfacial Tension Range | 1–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1700 °C (long-term: 1650 °C) |
| Ultimate Vacuum | 5 × 10⁻⁵ Pa |
| Heating Rate | 3–5 °C/min |
| Temperature Control Precision | ±1 °C (>1000 °C), ±0.1 °C (<1000 °C) |
| Cooling System | Water-cooled, 1200 W capacity, flow rate 10–20 L/min, pressure 1.0–1.3 bar |
| Imaging | Industrial color CCD, 750 TV lines, minimum illumination 0.0005 lux |
| Light Source | Adjustable cold LED backlight, >20,000 h lifetime |
| Lens | 300 mm working distance telecentric lens with continuous zoom |
| Software Analysis Methods | 6 algorithms (θ/2, tangent, circle fit, ellipse fit, height measurement, automated image analysis) |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCI-200 |
| Price Range | USD 28,000 – 71,000 |
| Surface Tension Range | 0–500 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Principle | Wilhelmy Plate Method |
| Trough Material | PTFE (Teflon®) |
| Trough Area | 30 cm × 10 cm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upward, Downward, Leftward, Rightward |
| Temperature Control Range | 5–95 °C |
| Laser Source | Adjustable 532 nm Green Laser (20 mW / 50 mW) |
| Objective | Continuous Zoom, Working Distance 90 mm, Magnification Equivalent to 700–110 px/mm, Viewing Angle 45°–60° |
| Power Supply | AC 220 V ±10%, 50 Hz, Max. 150 W |
| Brand | ZYKX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ZYWNP-L-S01M / ZYWNP-2-0.75 / ZYWNP-3-0.75 / ZYWNP-3-1.5 / ZYWNP-3-2.2 |
| Voltage | 220 V or 380 V |
| Power | 0.25–2.2 kW |
| Flow Rate | 0.2–5.7 m³/h |
| Bubble Size Distribution Peak | 150 ± 30 nm |
| Bubble Concentration | 1×10⁷–1×10⁹ particles/mL |
| Zeta Potential | −30 to −40 mV |
| Dissolved Oxygen Increase | ≥30% vs. feed water |
| Brand | ZYKX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYWNP-2 |
| Power Supply | 220 V |
| Rated Power | 0.37 kW |
| Average Flow Rate | 1.0 m³/h |
| Bubble Size Distribution Peak | 150 ± 30 nm |
| Bubble Concentration | 10⁷–10⁹ bubbles/mL |
| Zeta Potential | −30 to −40 mV |
| Dissolved Oxygen Increase | ≥30% |
| Operating Principle | Combined Mechanical Dispersion & Pressure-Saturation |
| Brand | ZYKX |
|---|---|
| Origin | Shanghai, China |
| Model | ZYWNP-WJS-1 |
| IP Rating | IPX7 |
| Optical Resolution | 0.6–4 µm/pixel |
| Measurement Range | 1–100 µm (ISO-compliant microbubble diameter range) |
| Working Distance | 13 mm (from outer glass window to sample plane) |
| Zoom Ratio | 0.7–4.5× mechanical, 9-step motorized |
| Camera Frame Rate | 60 fps (standard), up to 2000 fps (optional high-speed configuration) |
| Dimensions (L×W×H) | 600 × 200 × 200 mm |
| Weight | ~10 kg |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 % |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZYKX-500C |
| Measurement Range | 1×10⁻⁶–100 mN/m |
| Resolution | 0.001 mm (optical readout) |
| Temperature Control Range | RT+5°C to 90°C (internal heating) |
| Temperature Accuracy | ±0.1°C |
| Rotational Speed Range | 1,000–10,000 rpm |
| Speed Stability | ±5 rpm |
| Imaging Resolution | 768×576 pixels |
| Frame Rate | 60 fps |
| Optical Zoom | 10× (lens) + 2× (digital) |
| Interface | USB 3.0 (video), RS-232 (data), USB/COM (control) |
| Power Supply | 220 V/50 Hz ±10% or 110 V/60 Hz ±10% |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZYKX500C |
| Measurement Range | 10⁻⁷–100 mN/m |
| Resolution | 0.001 mm (image) / 0.01 mN/m (tension) |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | RT+5°C to 95°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed | 1,000–10,000 rpm (±5 rpm) |
| Imaging | USB digital CCD, 60 fps, 752×480 px |
| Trigger Mode | RPM-synchronized |
| Power Interface | USB & RS-232 |
| Compliance | ASTM D971, ISO 6295, USP <721>, GLP-ready data logging |
| Brand | Jiubin Instruments |
|---|---|
| Model | DSC-300L |
| Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C (extended capability to 1050 °C per specification) |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 µW |
| DSC Dynamic Range | ±800 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), plus dedicated purge gas line |
| Gas Flow Range | 0–300 mL/min |
| Gas Pressure Limit | ≤1 MPa |
| Display | 7-inch industrial-grade capacitive touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect protocol |
| Compliance | GB/T 19466.2–2004, GB/T 19466.3–2004, GB/T 19466.6–2009, ISO 11357-2:1999, ISO 11357-3:1999 |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-117A-Q |
| Max Test Force | 20 kN |
| Force Accuracy | ±0.5% FS |
| Tensile/Compression Stroke | 1000 mm |
| Displacement Resolution | 0.01 mm |
| Displacement Accuracy | ±0.01% FS |
| Speed Range | 0.01–500 mm/min |
| Speed Control Accuracy | ±0.1% (at setpoint), ±10.0% (full range) |
| Brand | Aerospace Vertical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJD-C Dielectric Constant and Dissipation Factor Tester |
| Price Range | USD 4,200 – 8,400 (FOB) |
| Frequency Range | 10 kHz – 70 MHz / 100 kHz – 160 MHz |
| Core Components | Q-meter main unit, precision parallel-plate or coaxial fixture, calibrated inductors |
| Standards Compliance | GB/T 1409–2006, GB/T 5594.4–2015, GB/T 1693–2007 |
| Primary Applications | Dielectric constant (ε′), loss factor (ε″), dissipation factor (tan δ), and complex permittivity characterization of solid and liquid insulating materials |