Physical Property Testing Instruments
Filter
Showing 10141–10170 of 12279 results
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Precision Air Bearing |
| Temperature Range | -10 to 200 °C |
| Frequency Range | 10⁻⁴ to 628 rad/s |
| Minimum Angular Velocity | 10⁻⁴ rad/s |
| Maximum Angular Velocity | 300 rad/s |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 10 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Compliance | ASTM D4065, ASTM D7028, ISO 6721, ISO 11359, USP <1031> |
| Cooling Range | –100 °C to 600 °C |
| Force Range | 0.1 mN to 18 N |
| Displacement Resolution | 0.1 nm over 25 mm dynamic range |
| Environmental Options | Dual configurable environmental chambers (inert gas, humidity, vacuum) |
| Control Architecture | Non-contact voice-coil motor with continuous force control |
| Bearing System | Low-compliance air bearing |
| Strain Sensing | Direct optical encoder-based strain measurement |
| Software Platform | TRIOS v5.x with 21 CFR Part 11 compliant audit trail and GLP/GMP-ready workflows |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| Temperature Precision | ±0.01 °C |
| DSC Heat Flow Range | ±500 mW |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 250 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Precision | ±0.008 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Capacity | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without liquid nitrogen) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 2500 |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | –180 °C to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Throughput | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without LN₂) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25P |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –130 °C to 550 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Pressure Range | 1 Pa to 7 MPa (0.0001–1,000 psi) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC2500 |
| Temperature Range | –180 to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Baseline Flatness (–50 to 300 °C) | <5 μW |
| Baseline Repeatability (–50 to 300 °C) | <10 μW |
| Enthalpy Accuracy | ±0.04 % |
| Heating/Cooling Rate | 0.1–100 K/min |
| Modulated DSC | Standard |
| Tzero® Technology | Advanced (T4P) |
| Direct Cp Measurement | Supported |
| User-Replaceable Furnace | Yes |
| 54-Position Autosampler | Standard |
| Dual-Gas Delivery Module | Standard |
| Color Touchscreen Interface | Standard |
| Optical Accessory Compatibility | Optional |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery HP-TGA 75 / 750 / 7500 |
| Temperature Range | Up to 1100 °C |
| Balance Sensitivity | 0.1 µg |
| Operating Environment | Controlled High-Pressure Atmosphere (up to 75, 750, or 7500 psi) |
| Instrument Type | Benchtop Integrated High-Pressure TGA System |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software architecture |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Discovery HR 30 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.05 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Discovery Hybrid Rheometer HR 10 |
| Instrument Type | Rotational Rheometer |
| Thrust Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Discovery Hybrid Rheometer HR 20 |
| Instrument Type | Rotational Rheometer |
| Thrust Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DLF-1200 |
| Temperature Range | RT to 1200 °C |
| Laser Pulse Width | 300–400 µs |
| Atmosphere Options | Air, Inert Gas, Vacuum (down to 10⁻³ torr) |
| Detection | Liquid Nitrogen-Cooled IR Detector |
| Heating System | Resistive Furnace |
| Measurement Principle | Laser Flash Analysis (LFA) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery SDT 650 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1500 °C |
| Temperature Stability | ±2% |
| Maximum Sample Mass | 200 mg |
| Base Pressure | 50 μTorr |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 550 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | <25 µg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 5500 |
| Temperature Range | Ambient to 1200 °C |
| Balance Sensitivity | < 0.1 µg |
| Heating/Cooling Rate | 0.1 to 500 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | < 10 µg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 RH |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Displacement Resolution | 15 nm |
| Maximum Sample Length | 26 mm |
| Displacement Range | ±2.5 mm |
| Cooling Option | Mechanical Cooling Accessory (MCA 70) to −70 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery X3 DSC |
| Sample Capacity | Up to 3 simultaneous samples |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | –180 °C to 550 °C |
| Temperature Accuracy | ±0.025 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DXF-200 / DXF-500 / DXF-900 |
| Measurement Principle | Laser Flash Method (Xenon Lamp-Based) |
| Maximum Sample Diameter | 25 mm |
| Pulse Width | 400–600 µs |
| Optical System | Reflective, Multi-Faceted Light Guide |
| Temperature Range Options | Up to 200 °C / 500 °C / 900 °C (Model-Dependent) |
| Compliance | ASTM E1461, ISO 22007-4, DIN EN 821-2 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DLF 1600 |
| Measurement Principle | Laser Flash Method (LFA) |
| Maximum Operating Temperature | 1600 °C |
| Laser Pulse Energy | 1.35 J (Nd:Glass) |
| Pulse Width | 300–400 µs |
| Atmosphere Options | Air, Inert Gas, Vacuum (down to 10 Torr) |
| Furnace Heating Element | MoSi₂ |
| Insulation | High-Purity Alumina Hot Zone |
| Sample Capacity | Up to 6 positions with rotating carousel |
| Detector | Liquid Nitrogen-Cooled Infrared Detector |
| Beam Delivery | Patented Fiber-Optic Light Pipe (99% uniform transmission) |
| Compliance | ASTM E1461, ISO 22007-4, DIN EN 821-2 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DLF 2800 |
| Instrument Principle | Laser Flash Method (LFA) |
| Dimensions (L×W×H) | 12.7 × 12.7 × 6 cm |
| Accuracy | ±2.3% |
| Thermal Conductivity Range | 0.1–2000 W/m·K |
| Repeatability | ±2% |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DTC-300 |
| Measurement Principle | Guarded Heat Flow Method (ASTM E1530) |
| Sample Temperature Range | −40 °C to 200 °C (with optional chiller and heater modules) |
| Thermal Resistance Range | Three interchangeable sensor modules covering low-, medium-, and high-resistance regimes |
| Sample Form Compatibility | Solids, thin films (multi-layer stack), pastes, liquids (with custom containment) |
| Compliance | ASTM E1530, ISO 8301, EN 12667 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DuraPulse |
| Instrument Type | Dynamic Mechanical Durability Tester for Cardiovascular Devices |
| Compliance | ISO 5840-1:2021, ISO 5840-2:2021, ISO 5840-3:2021 |
| Test Stations | Configurable as 2-, 4-, or 6-channel modular units |
| Actuation Principle | Electromagnetic linear motor with closed-loop digital servo control |
| Waveform Fidelity | ≤ ±0.5% deviation from target physiological waveform (e.g., sinusoidal, pulsatile, or patient-specific waveforms) |
| Environmental Control | Independent, sealed test chambers with integrated temperature and fluid medium monitoring |
| Warranty | 10-year limited warranty on linear motor assemblies |
| Software Platform | DuraPulse Control Suite v4.x with audit trail and 21 CFR Part 11–compliant user access controls |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3200 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / Dynamic Mechanical Thermal Analyzer (DMTA) |
| Temperature Range | −150 °C to +315 °C |
| Temperature Accuracy | ±0.3 °C |
| Force Range | ±225 N (optional ±450 N) |
| Displacement Range | ±6.5 mm |
| Frequency Range | 10⁻⁵ Hz to 300 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3330 |
| Instrument Type | Dynamic Mechanical Tester (DMA/DMTA-Compatible Platform) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | ±3000 N |
| Maximum Dynamic Torque (with optional torsion module) | 28 N·m |
| Configuration Options | Benchtop or Floor-standing |
| Power Requirement | Standard 220 V AC outlet |
| Pneumatic Interface | Compressed air supply required |
| Structural Design | Rigid dual-column beam architecture |
| Vertical Stroke Adjustment | Integrated pneumatic/electric/manual lift mechanism |
| Multi-Axis Capability | Optional torsion motor for axial-torsional coupling |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3450 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / DMTA |
| Force Range | ±3 kN (standard), ±6 kN (high-load option) |
| Displacement Range | up to ±22 mm |
| Frequency Range | 0.0001 Hz to 200 Hz |
| Temperature Range | –150 °C to 300 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3500 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | 7.5 kN (standard), 15 kN (optional) |
| Dynamic Stroke | 50 mm |
| Cooling | Air-cooled |
| Motor Mounting Options | Upper Crosshead (3510), Base-Mounted (3520), High-Load Configuration (3550) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ElectroForce |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Control | Physiological Saline Bath |
| Loading Mode | Displacement-Controlled Tension-Tension or Compression-Compression |
| Sample Capacity | Multiple Independent Test Stations |
| Cycle Resolution | High-Resolution Linear Encoder-Based Displacement Measurement |
| Compliance | Designed for ISO 14242-1, ASTM F2129, and FDA Guidance for Cardiovascular Implant Fatigue Testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 3300 |
| Frequency Range | 0.0001 – 100 Hz |
| Load Capacity Options | ±1000 N or ±3000 N (axial) |
| Torsion Options | ±14 N·m or ±25 N·m |
| Linear Stroke Extension Option | +150 mm |
| Force Resolution | ±0.02 N to ±3000 N |
| Drive Type | High-Performance Linear Electromagnetic Motor |
| Encoder Resolution | High-Resolution Optical Encoder (up to 62 revolutions for torsion) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TestBenches |
| Load Capacity Options | 200 N or 400 N |
| Configuration | Planar Biaxial TestBench with Integrated Digital Video Extensometry |
| Distribution Type | Authorized Distributor (Imported Equipment) |
