Physical Property Testing Instruments
Filter
Showing 10171–10200 of 11951 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q5000IR, Q500, Q50 |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HAAKE RotoVisco 1 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Mechanical Bearing |
| Minimum Speed | 0.0125 rpm |
| Maximum Speed | 1000 rpm |
| Maximum Torque | 50 mN·m |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HAAKE Viscotester 1 plus & 2 plus |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1 plus: 1.5–330 mPa·s |
| 2 plus | 0.3–4000 dPa·s (30–400,000 mPa·s) |
| Rotational Speed | 62.5 rpm |
| Temperature Capability | up to 150 °C |
| Repeatability | ±1% FSD |
| Standard Accuracy | ±5% FSD |
| Optional High-Accuracy Accuracy (VT 2 plus only) | ±1% FSD |
| Display Units | VT 1 plus defaults to mPa·s |
| Unit Conversion | 1 mPa·s = 1 cP |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HAAKE Viscotester C / D / E |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | L-type: 15–6,000,000 mPa·s |
| R-type | 100–40,000,000 mPa·s |
| Accuracy | ±1% FSD |
| Repeatability | ±0.2% |
| Speed Range | C/D: 0.1–200 rpm (21 speeds) |
| E | 0.01–200 rpm (54 speeds) |
| Compliance | ASTM D1084, D1286, D1439, D2196, D2556, ISO 2555, BS 6075 |
| Power Supply | 100–240 V, 50–60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HAAKE Viscotester Falling Ball C |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s (cP) |
| Temperature Range | −20 °C to +150 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Tube & Balls 1–2 & G | Borosilicate Glass |
| Balls 3–6 | Ni-Fe Alloy |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Viscotester iQ |
| Instrument Type | Rotational Rheometer |
| Bearing Type | Mechanical Bearing |
| Minimum Angular Velocity | 0.001 rad/s |
| Frequency Range | 0.1 Hz – 20 Hz |
| Maximum Angular Velocity | 157 rad/s |
| Maximum Torque | 100 mNm |
| Torque Resolution | 0.01 mNm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | VT550 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 2 – 10⁷ mPa·s |
| Speed Range | 0.5 – 800 rpm |
| Torque Range | 0.1 – 50 mN·m (up to 400 rpm), 0.1 – 20 mN·m (up to 800 rpm) |
| Temperature Range | −40 °C to +350 °C (dependent on optional temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Control Mode | Preset Programs (10 built-in), Controlled Deformation (CD) mode for yield stress determination |
| Software Integration | RheoWin (HAAKE proprietary software) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 21Plus-C Online X-ray Thickness Gauge |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Oscillating U-tube Densimeter (Note: Correction — actual principle is gamma-ray transmission, not oscillating tube |
| Instrument Category | Benchtop Laboratory / Industrial In-Line Density Meter |
| Detection Method | Non-contact Gamma-Ray Transmission Densitometry |
| Radiation Sources | Cs-137 or Co-60 |
| Density Measurement Principle | Attenuation-based gamma-ray transmission through process media |
| Temperature Operating Range | –40 °C to +75 °C |
| Environmental Rating | NEMA 4X / IP65 |
| Detector Configuration | Integrated or Remote (Split) |
| Multiplexing Capability | Up to 4 independent measurement channels per microprocessor unit |
| Analog I/O | 4 × 4–20 mA inputs, 2 × 4–20 mA outputs, 2 × 0–10 V inputs, 2 digital inputs, 2 relay outputs |
| Communication Interfaces | RS232 / RS485, 10/100 M Ethernet with ESD protection, USB |
| Power Supply | 115/230 V AC ±10%, 50/60 Hz or 24 V DC |
| Certified Compliance | IEC 60068-2-6 (sinusoidal vibration), IEC 60068-2-64 (random vibration), IEC 60068-2-27 (shock), IEC 60068-2-38 (temp/humidity cycling) |
| Radiation Safety | Lead-shielded source housing |
| activity range | 1–10,000 mCi (Cs-137) or 1,000–3,000 mCi (Co-60) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Upright Temperature and Humidity Controlled Chamber |
| Model | 3961 |
| Internal Volume | 29 cu ft (821.2 L) |
| Temperature Range | 5°C above ambient to 60°C |
| Temperature Uniformity | ±0.4°C at 30°C, ±0.3°C at 37°C, ±0.5°C at 45°C |
| Temperature Stability | ±0.1°C |
| Control System | Enviro-Scan™ Microprocessor |
| Construction | Exterior – Powder-coated cold-rolled steel |
| Insulation | 2 in. (5.1 cm) fiberglass |
| Door | Heated triple-pane tempered glass |
| Shelves | 5 standard, up to 26 max., solid stainless steel, adjustable on 2 in. centers |
| Shelf Load Capacity | 13.6 kg (30 lb) per shelf |
| Dimensions (L×W×H) | 83.8 × 78.7 × 203.2 cm (33 × 38 × 80 in.) |
| Internal Dimensions (L×W×H) | 65.5 × 77.7 × 152.4 cm (25.8 × 30.6 × 60 in.) |
| Port Configuration | Two 2.4 in. (6.1 cm) I.D. access ports, one per side |
| Electrical Requirements | 200/230 V, 50/60 Hz, 5 A, 150 W |
| Safety Certifications | UL Listed, CE Marked |
| Overtemperature Protection | Independent mechanical thermostat + precision thermistor |
| Alarms | Audible/visual high/low temperature alarm |
| Data Output | Analog voltage output for external monitoring systems |
| Mobility | Locking casters + adjustable leveling feet |
| Brand | Thermo Scientific HAAKE |
|---|---|
| Origin | Germany |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air-bearing |
| Minimum Rotational Speed | 0.001 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Torque Range | 0.007 µNm – 150 mNm |
| Torque Resolution | 0.007 µNm |
| Frequency Range | 0.0001 – 209.4 rad/s |
| Frame Architecture | Folded H-Frame with Mineral Composite Base |
| Compliance | ASTM D4402, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11 (optional software module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | MARS iQ |
| Instrument Category | Rotational Rheometer |
| Bearing Type | Mechanical Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Frequency Range | 0.01–20 Hz |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 2.0 µN·m |
| Brand | Thermo Scientific HAAKE |
|---|---|
| Origin | Germany |
| Model | MARS iQ |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Torque Range | 0.002–125 mNm |
| Torque Resolution | 2.0 µNm |
| Frequency Range | 0.001–209.4 rad/s |
| Frame Architecture | Folded H-Frame with Mineral Composite Construction |
| Temperature Control Interface | Auto-recognized, Color-Coded Modular System |
| Software Platform | HAAKE RheoWin (with optional 21 CFR Part 11 compliance module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer Coupling Module |
| Model | Rheonaut |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1 × 10⁻⁸ rpm |
| Frequency Range | 10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| ATR Crystal Material | Diamond (Single-Reflection) |
| Temperature Control Options | Peltier (0–120 °C) or Electric Heating (RT–400 °C) |
| Detector | DTGS |
| Polarization Options | Manual/Automatic Dual-Axis Polarizers |
| Compliance | ASTM D3835, ISO 6721-10, USP <1043>, GLP/GMP-ready data audit trail support |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Materials Characterization |
| Instrument Type | Torque Rheometer |
| Motor Bearing | Not Applicable |
| Minimum Rotational Speed | Not Specified |
| Maximum Rotational Speed | Not Specified |
| Frequency Range | Not Specified |
| Maximum Torque | Not Specified |
| Torque Resolution | Not Specified |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Process Thickness Gauge |
| Price Range | USD 70,000 – 140,000 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | FD910, FD950, FD960, FD900, ID900, PD900 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop & In-line Process |
| Application Focus | Petroleum, Petrochemical, Chemical, LNG, and Power Generation |
| Density Range (Liquid) | 0–2100 kg/m³ |
| Density Range (Gas) | 0–1000 kg/m³ (FD900/ID900), 0–250 kg/m³ (PD900) |
| Accuracy (Liquid) | ±0.1 kg/m³ |
| Repeatability (Liquid) | 0.02 kg/m³ |
| Temperature Compensation | Integrated 4-wire PT100 (1/3 DIN) |
| Operating Temp (Liquid) | −50°C to +180°C |
| Operating Temp (Gas) | −200°C to +200°C |
| Pressure Rating | Up to 170 bar (FD900), 150 bar (ID900), 100–150 bar (PD900) |
| Enclosure Rating | IP65 / NEMA 4X |
| Hazardous Area Certifications | ATEX Ex ia IIC T4/T6, CSA Class I Div 1 Groups B, C, D, IECEx, NACE MR0175/ISO 15156 compliant |
| Output Options | 4–20 mA + HART (HME900), Frequency/Modulated Current (CM515), Dual-Channel PT100 |
| Calibration | NIST-traceable, performed in ISO/IEC 17025-accredited laboratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ELITE |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ThermoConcept |
| Pricing | Upon Request |
| Brand | NANJING DAZHAN |
|---|---|
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static/dynamic) |
| Balance Resolution | 0.1 µg |
| Balance Accuracy | ±0.01 mg |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color touchscreen |
| Communication | USB 2.0 bidirectional interface |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, GLP-compliant report generation |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1000 |
| Temperature Range | RT–1000°C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless Steel Gas Pathway |
| Cooling | Water-Cooled Furnace |
| Software Platform | Infinity Pro for Windows |
| Compliance | ASTM E1131, ISO 11358, USP <691>, GLP-Ready |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1500 |
| Temperature Range | RT–1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless-Steel Dual-Gas Purge System |
| Software Platform | Infinity Pro for Windows |
| Optional Modules | EGA Interface with Heated Transfer Line, Auto Gas Switching, Step ISO Compliance Mode, Water-Cooled Furnace |
| Brand | Thermtest |
|---|---|
| Origin | Canada |
| Model | TLS-100 |
| Measurement Principle | Transient Line Source Method |
| Thermal Conductivity Range | 0.1–5 W/m·K |
| Thermal Resistance Range | 0.2–10 m·K/W |
| Accuracy | ±5% |
| Repeatability | ±2% |
| Measurement Duration | 120 s |
| Operating Temperature Range | −40 to 100 °C |
| Minimum Sample Dimensions | Ø50 mm × 100 mm (L) |
| Probe Diameter | 1.6 mm |
| Data Storage | Internal memory + SD card (FAT32 formatted, up to 32 GB) |
| Compliance | ASTM D5334-22 |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Weight | 1.2 kg |
| Dimensions (L×W×H) | 50 mm × 100 mm × 220 mm |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Theta-3D |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Angular Resolution | 0.1° |
| Sample Stage Dimensions (L × W × H) | Unlimited × 180 mm × 22 mm |
| Image Resolution | 1280 × 960 pixels |
| Surface & Interfacial Tension Range | 0–1000 mN/m |
| Brand | Theva |
|---|---|
| Origin | Germany |
| Model | TAPESTAR™ |
| Critical Current Range | 50–400 A (TAPESTAR™), 50–1000 A (TAPESTAR™ XL) |
| Measurement Principle | Non-contact magnetic induction (perpendicular field scanning with multi-channel Hall sensor array) |
| Operating Temperature | Liquid nitrogen (77 K) |
| Tape Speed | 0–55 m/h (TAPESTAR™), 0–200 m/h (TAPESTAR™ XL) |
| Axial Resolution | 0.5 mm @ 55 m/h (TAPESTAR™), 1 mm @ 55 m/h (TAPESTAR™ XL) |
| Transverse Resolution | 0.6 mm (4 mm tape), 1.5 mm (10 mm tape) |
| Magnetic Field Range | 0–40 mT (TAPESTAR™), 0–120 mT (TAPESTAR™ XL) |
| Sensor Channels | 7 (TAPESTAR™), 21 (TAPESTAR™ XL) |
| Accuracy | ±3% (≥15 A, calibrated reference sample) |
| Tape Width Customization | Up to 12.4 mm |
| Max. Tape Thickness | 200 µm |
| Tape Tension Control | 5 N (TAPESTAR™), 5–11 N (TAPESTAR™ XL) |
| Power Supply | 220 V / 50 Hz / 250 W (TAPESTAR™), 400 V / 3-phase / 50 Hz / 3 kW (TAPESTAR™ XL) |
| Dimensions (L×W×H) | 750 × 710 × 860 mm (TAPESTAR™), 2630 × 880 × 1550 mm (TAPESTAR™ XL) |
| Weight | 98 kg (TAPESTAR™), 475 kg (TAPESTAR™ XL) |
| Environmental Requirements | 5–35 °C, 10–90% RH (non-condensing), vibration-isolated installation |
| Brand | Thicktest |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | SKT-500 |
| Pricing | Upon Request |
| Brand | Thorlabs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MC2000 |
| Pricing | Upon Request |
| Brand | Thorlabs |
|---|---|
| Origin | USA |
| Model | SPL-LEDD |
| Output Current Range | 0–1000 mA (DC4100 variant), 0–2000 mA (DC2100 variant), 0–1200 mA (LEDD1B variant) |
| Forward Voltage Compliance | 5 V (DC4100), 12 V (LEDD1B), 24 V (DC2100) |
| Modulation Bandwidth | DC–100 kHz (sine/arbitrary), up to 100 MHz internal (DC3100 series) |
| Trigger Input | 0–5 V TTL-compatible |
| USB Interface | USB 2.0 with CDC-class enumeration |
| Control Modes | Constant Current, Analog Modulation, External Trigger, PWM Pulse Sequencing |
| Software Support | µManager plugin, Thorlabs Kinesis, LabVIEW VIs |
| Compliance | CE, RoHS, FCC Class B |
| Key Features | Three-chamber design (hot, cold, test chambers) |
|---|---|
| Controller options | TEMI880 color touchscreen programmable temperature/humidity controller (English/Chinese switchable) or TEMI300 membrane-key programmable controller (English only) |
| Protection functions | Compressor overheat/overcurrent/overpressure protection, heater dry-run prevention, chamber over-temperature alarm, low-water-level detection |
| Standard configuration | Double-glazed tempered observation window |
| Temperature/humidity control | Balanced Temperature and Humidity Control System (BTSC) |
| Operating ambient | +5°C to +35°C |
| Heating | Nickel-chromium alloy wire heaters |
| Humidification | Surface evaporation type |
| Air circulation | Wide-band forced-air system (top discharge, bottom intake) |
| Cooling method | Air-cooled |
| Refrigeration | Original French “Tecumseh” hermetic compressors |
| Refrigeration circuit | Single- or dual-stage low-temperature loop design |
| Construction | Outer shell — SUS304B stainless steel |
| Airflow | Multi-wing centrifugal blower |
| Compliance | Designed to support ISO 16750-4, JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14, and ASTM D4332 test protocols |