Physical Property Testing Instruments
Filter
Showing 211–240 of 4353 results
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XXG-3005ZH, XXG-2505ZH |
| Power Supply | 220 V ±10% |
| Input Power | 3.5 kW |
| High Voltage Range | 50–300 kV (continuously adjustable) |
| Tube Current Range | 1–5 mA |
| Max. Penetration Thickness (A3 steel) | 60 mm |
| Film Density | D = 2.0 ± 0.1 |
| Cooling Method | Forced Air Cooling |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XXG-3005ZH |
| Voltage Range | 50–300 kV |
| Current Range | 1–5 mA |
| Focal Spot Size | 2.5 × 2.5 mm |
| Radiation Beam Angle | 40° ± 5° |
| Duty Cycle | 1:1 (Continuous Operation Mode) |
| Max. Penetration in A3 Steel | 50 mm |
| Generator Weight | 28 kg |
| Generator Dimensions | 345 × 345 × 670 mm |
| [Brand | Alpha |
|---|---|
| Origin | USA |
| Model | AR008 |
| Type | High-Purity Combustion Flux for Inert Gas Fusion Analyzers |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/CS Instruments |
| Form | Granular |
| Purity | ≥99.95% (certified) |
| Packaging | Sealed 100 g or 500 g HDPE bottles under argon atmosphere |
| Storage | Dry, cool, inert environment |
| Safety | Non-hygroscopic, low volatility, compliant with OSHA and GHS handling guidelines] |
| [Brand | Alpha / ALPHA |
|---|---|
| Origin | USA |
| Model | AR3818F |
| Type | Low-carbon graphite crucible |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/O/N/H analyzers |
| Purity | <5 ppm C (typical), <10 ppm S (typical) |
| Dimensions | Ø25 mm × 35 mm (ID × height, nominal) |
| Max. Operating Temperature | 3,000 °C in inert atmosphere |
| Packaging | 10 pcs per sealed vacuum bag, 100 pcs per box] |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | AR5431P |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH analyzers |
| Packaging | 100 pcs per box |
| OEM Cross-Reference | ELTRA® 775-431, LECO® 775-431, HORIBA® 775-431, Bruker® 775-431 |
| Brand | Alpha Resources |
|---|---|
| Origin | USA |
| Model | AR433 |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH-p/D Series |
| Packaging | 50 pcs per box |
| OEM Cross-Reference | 90185775-433 |
| Brand | Alpha |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EM2 |
| Price Range | USD 700 – 1,270 (FOB) |
| Operating Temperature | 0–43°C |
| Full-Scale Range | 0–199.999 µT |
| Resolution | 0.001 µT (1 nT) |
| Accuracy | ±0.5% of reading ±0.001 µT |
| Thermal Drift | <1.15 nT/°C |
| Dimensions | 194.7 × 100.6 × 44.3 mm |
| Weight | 525 g (with batteries) |
| Power | 3 × AA alkaline (10 h with backlight, 15 h without) |
| Display | Backlit LCD, relative-zero mode, vector capability (field magnitude & direction) |
| Brand | AlphaLab |
|---|---|
| Origin | USA |
| Model | GM1-HS |
| Measurement Range | ±799.99 G |
| Resolution | 0.01 G |
| Accuracy | ±1% of reading (16–29°C), ±2% (-4–65°C) |
| Probe Type | Single-axis Hall-effect sensor with 100 cm flexible cable |
| Probe Dimensions | 2.3 × 4.8 × 24 mm |
| Instrument Dimensions | 132 × 91 × 41 mm |
| Weight | 227 g |
| Power | 9 V alkaline battery (≈20 h operation) |
| Display update rate | 4 Hz |
| Operating temperature | -4°C to +65°C |
| Storage temperature | -20°C to +70°C |
| Brand | Alphalab |
|---|---|
| Origin | USA |
| Model | GM1-ST |
| Measurement Range | ±19,999.9 G (±1.99999 T) |
| Resolution | 0.1 G |
| Accuracy | ±1% of reading (16–29°C), ±2% (-4–65°C) |
| Display | 5½-digit LCD, polarity-indicating |
| Probe | Integrated Hall-effect sensor, 1.5 × 4.3 × 24 mm, mounted on 100 cm flexible cable |
| Operating Temperature | -4°C to +65°C |
| Power | 9 V alkaline battery (≈40 h life) |
| Certifications | CE, NIST-traceable calibration certificate included |
| Compliance | Meets IEC/EN 61326-1 for EMC and safety |
| Brand | Alphalab |
|---|---|
| Origin | USA |
| Model | GM1-ST |
| Measurement Range | 0 to 19,999.9 G |
| Resolution | 0.1 G |
| Display | 5½-digit LCD |
| Update Rate | 4 readings/sec |
| Sensor Cable Length | 100 cm (flexible, bendable tip) |
| Minimum Gap Clearance | 0.060 in (1.5 mm) |
| Operating Principle | Hall-effect DC magnetic field sensing |
| Brand | AlphaLab |
|---|---|
| Origin | USA |
| Model | GM2 |
| Measurement Range (ST Probe) | ±19,999.9 G / 0.1 G resolution |
| Measurement Range (HS Probe) | ±799.99 G / 0.01 G resolution |
| DC Accuracy (16–29°C) | ±1% of reading + 10 counts |
| AC Accuracy (45–800 Hz) | ±3% of reading + 10 counts |
| Peak Hold Accuracy | ±2% of reading + 10 counts |
| AC Bandwidth | DC to 1.5 kHz (−3 dB) |
| Peak Capture Window | 2 ms |
| Analog Output | ST: ±2 V (±20 kG) |
| HS | ±0.8 V (±800 G) |
| Probe Cable Length | 100 cm |
| Dimensions | 138 × 91 × 41 mm |
| Weight | 213 g |
| Power | 9 V alkaline battery (ST: ~40 h |
| HS | ~20 h) |
| Brand | AlphaLab |
|---|---|
| Origin | USA |
| Model | MGM |
| Measurement Range | ±2000 mG (±200 µT) |
| Resolution | 0.01 mG (1 nT) |
| Display | 5½-digit, -1999.99 to +1999.99 mG |
| Update Rate | 3 Hz |
| Analog Output | ±2 V = ±2 G (±2000 mG), ±0.5% accuracy |
| Bandwidth | DC–3 Hz standard (optional DC–300 Hz) |
| Sensor Type | Axial anisotropic magnetoresistive (AMR) |
| Active Sensor Area | 1 mm × 0.2 mm |
| Temperature Stability | Offset TC < 0.01 mG/°C |
| Accuracy (Gain) | ±0.5% FS |
| Offset Error | ±0.5 mG |
| Operating Temp | 0–45°C |
| Dimensions | 18 × 9 × 5 cm |
| Weight | 325 g (incl. battery) |
| Brand | AlphaLab |
|---|---|
| Origin | USA |
| Model | MR3 |
| Measurement Principle | Magnetoresistive (MR) Sensor Array |
| Axes | X, Y, Z (orthogonal vector components) |
| Full-Scale Range | ±1999.99 mG (±199.999 µT) |
| Resolution | 0.01 mG (1 nT) |
| Accuracy | ±0.5% of reading + ±0.50 mG offset error |
| Sampling Rate | 2 Hz (updates per second) |
| Temperature Stability | Offset TC < 0.01 mG/°C |
| Repeatability | ±0.01 mG (1 nT) at constant temperature |
| Sensor Geometry | Three MR sensors embedded in a 25 mm cube, positioned ~4 mm below surface, with mechanical X/Y/Z axis markings on housing |
| Cable Length | 100 cm flexible coaxial cable |
| Power | 4 × AA alkaline batteries (included, ~40 h operation) or universal AC adapter (included) |
| Data Logging | Internal storage of X/Y/Z/M and peak values |
| Display | Simultaneous readout of instantaneous and peak values for all four parameters (X, Y, Z, M) |
| Compliance | CE-marked |
| Brand | AlphaLab |
|---|---|
| Origin | USA |
| Model | UHS2 |
| Frequency Range | 13 Hz – 75 kHz |
| Full-Scale Range | 1999.99 mG |
| Resolution | 0.01 mG |
| Accuracy | ±3% (45 Hz – 5 kHz), ±7% (<45 Hz and >5 kHz) |
| Power | 9 V alkaline battery (~20 h operation) |
| Measurement Modes | True 3-Axis ELF+VLF, 3-Axis VLF-only (1–75 kHz), Single-Axis Full-Bandwidth (13 Hz–75 kHz) |
| Brand | AlphaLab |
|---|---|
| Origin | USA |
| Model | VGM |
| Measurement Range | ±799.99 G |
| Resolution | 0.01 G |
| Accuracy | ±1% of reading (16–29 °C), ±2% (−4–65 °C) |
| Axis Configuration | Triaxial (X, Y, Z) DC magnetic field sensors co-located within 1.5 mm at probe tip |
| Vector Magnitude Calculation | √(X² + Y² + Z²) |
| Peak Hold Time Constant | 5 ms |
| Alarm Response Time | 5 ms |
| Alarm Threshold Range | 1.00–790.00 G (100-step adjustable) |
| Probe Dimensions | 6.3 × 6.3 × 50 mm |
| Display | Real-time magnitude + individual X/Y/Z components (polarity included) + simultaneous peak values |
| Power | 9 V alkaline battery (≈10 h life) or USB adapter (included) |
| Compliance | CE marked |
| Calibration | NIST-traceable certificate included |
| Output Interface | 3.5 mm mono audio jack (active-high 3.5 V alarm signal, 0 V inactive) |
| Environmental Operating Range | −4 to +65 °C |
| Physical Dimensions | 147 × 97 × 51 mm |
| Weight | 332 g |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C (optional low-temp module: –130°C to 1200°C) |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated high-sensitivity TCD (dual-filament or quad-filament, W or Au/W), compatible with external MS, FTIR, FID, GC |
| Gas Handling | Built-in precision gas mixer, heated/insulated lines & valves, vapor-saturated gas generation (temperature-controlled saturator) |
| Sample Configuration | Removable clamshell furnace, quartz U-tube/bubble tube/straight-wall tubes (low-pressure) |
| Safety Systems | Multi-point temperature monitoring, over-temperature cutoff, TCD flow interlock, dry-run protection, front emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace + bed), FDA 21 CFR Part 11–ready audit trail (optional), GLP/GMP-compliant data export |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated High-Sensitivity TCD (dual-filament or quad-filament, W or Au/W), MS/GC/FTIR/FID compatibility |
| Sample Capacity | 0.1–1.0 g |
| Sample Tube Types | Quartz U-tube, bubble tube, straight-wall tube (low-pressure) |
| Tubing | 1/16″ OD 316 SS, heated throughout |
| Gas Mixing | Internal precision gas mixer (no external mixer required) |
| Cooling | Automated air-cooling module |
| Safety Systems | Dual-zone temperature monitoring, over-temperature cutoff, TCD flow interlock, front-panel emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace & bed), GLP-compliant data audit trail, FDA 21 CFR Part 11-ready configuration options |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 TPD/TPO/TPR Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AMI-300HP High-Pressure Chemisorption Analyzer (100 bar) |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable up to 12 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar / 100 bar (dual-range configuration) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300IR In Situ FTIR-Coupled Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300Neo Basic Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira |
|---|---|
| Origin | USA |
| Model | AMI-300S Corrosion-Resistant Chemisorption Analyzer |
| Testing Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional 100 bar) |
| Analytical Capabilities | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AMI-400 Automated Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | CGS-3 MD |
| Laser Wavelength Options | 660 nm (50 mW DPSS) or 532 nm (50 mW Nd:YAG) |
| Detector Configuration | 4 or 8 parallel APD/PMT detectors |
| Angular Spacing | 16° between adjacent detectors (8-detector mode) |
| Correlator | One or two ALV-7004 multi-tau digital autocorrelators (supporting 4- or 8-channel operation) |
| Application Focus | Time-resolved static and dynamic light scattering (SLS/DLS) of rapidly evolving colloidal, polymeric, and biomolecular systems |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | ALV-CorrTector-II |
| Detector Type | Integrated Avalanche Photodiode (APD) with Multi-τ Digital Correlator |
| Count Rate | >80 Mcps |
| Dark Count Rate | ~250 cps |
| Afterpulsing | Minimized with Embedded Correction Algorithm |
| Peak Quantum Efficiency | 60% |
| QE at 488 nm | 53% |
| QE at 532 nm | 40% |
| Operating Temperature Range | 15–35 °C |
| Dimensions | 120 × 58 × 30 mm |
| Weight | 250 g |
| Interface | Mini-USB 2.0 |
| OS Compatibility | Windows 10 (64-bit) |
| Power Consumption | <2 W |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | ALV/CGS-3 |
| Laser Source | 50 mW DPSS, 660 nm |
| Angular Range | 12°–152° |
| Angular Resolution | ±0.025° |
| Angular Accuracy | 0.003° at 25.000° |
| Detector | Dual APD (QE >65% @ 660 nm) |
| Correlation Method | Heterodyne quasi-cross-correlation & auto-correlation |
| Sample Cell | 85 mm OD quartz, centering ≤±5 µm, orthogonality ≤±10 µm, AR-coated 0°/180° windows |
| Temperature Control | Up to 70°C standard |
| Sample Volume Options | Standard cuvette + 5 mm NMR tube adapter |
| Attenuation | 8-step motorized optical density selection |
| Safety Class | EN 60825-1:2014 Class 1 (operational) |
| Compliance | GLP-ready architecture, audit-trail-capable software framework |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AI DC-48 |
| Pricing | Upon Request |
| Maximum Raw Storage Capacity | 768 TB |
| Drive Bay Count | 48 hot-swappable 3.5" SATA/SAS bays |
| Per-Drive Capacity | Up to 16 TB |
| Processor | Intel Xeon Scalable Series (multi-core) |
| Memory | 64 GB DDR4 ECC Registered RAM |
| Network Interface | Dual-port 10 GbE SFP+ with LACP support |
| Data Management Features | Hierarchical metadata tagging, spatial location indexing, thumbnail-based dataset preview, DICOM-compliant query engine, role-based access control (RBAC), automated backup scheduling |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AI-1000 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| X-ray Energy | 80 kV |
| Maximum Sample Diameter | 250 mm |
| Maximum Sample Height | 350 mm |
| Sample Weight Capacity | 5 kg |
| System Dimensions (W×D×H) | 1100 × 660 × 660 mm |
| Contrast Resolution | <1% |
| Minimum Detectable Defect Size | 0.1 mm |
| Radiation Leakage | <1 µSv/h |
| Net Weight | 350 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | AI-2000CT |
| Detector Type | Flat-Panel Detector |
| X-ray Energy | 195 kV |
| Maximum Sample Diameter | 500 mm |
| Maximum Sample Height | 500 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions (W×D×H) | 1900 × 1000 × 1600 mm |
| Contrast Resolution | <1% |
| Spatial Resolution (Defect Detection Limit) | 0.1 mm |
| Radiation Leakage | <1 µSv/h |
| Net Weight Range | 1500–5000 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | AI-3000CT |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| X-ray Energy Options | 250 kV / 320 kV / 450 kV |
| Maximum Sample Dimensions | Ø600 mm × H1000 mm |
| Maximum Sample Weight | 50 kg |
| System Dimensions (L×W×H) | 3500 mm × 2100 mm × 2250 mm |
| Contrast Resolution | <1% |
| Spatial Resolution (Defect Detection Limit) | 0.1 mm |
| Radiation Leakage | <1 µSv/h |
| Net Weight | 5000–6000 kg |