| Origin | Switzerland |
|---|---|
| Model | EM120 |
| Maximum Capacity | 124 g |
| Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost function (140% target temperature for first 3 min) |
| Termination Criteria | Automatic, semi-automatic (user-defined mass change per second), or time-based (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Stored Methods | 5 user-defined profiles |
| Security | Password-protected settings, physical lock slot |
| Interface | RS232 |
| Firmware Update | Network-enabled via PC connection |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM120 |
| Maximum Capacity | 124 g |
| Minimum Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Drying Time Range | 0.1–99.9 min |
| Termination Modes | Automatic, Semi-Automatic (Δdigit/sec or Δ%/sec), Fixed-Time |
| Data Output Interval | 0.1–10.0 min |
| Password Protection | Yes |
| Statistical Functions | Count, Mean, Max, Min, Standard Error |
| Interface | RS232 |
| Memory | 50 Method Programs, 999 Test Records |
| Preheating | 30–100 °C |
| Multi-Stage Heating | 3 programmable segments (temp + time per stage) |
| Boost Mode | 140% target temp for first 3 min |
| Firmware Update | Remote via network |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM60 |
| Maximum Capacity | 62 g |
| Minimum Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost Function (140% target temp for first 3 min) |
| Termination Modes | Automatic, Semi-Automatic (user-defined mass change per second), Timed (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Preset Methods | 5 |
| Security | Password Protection, Physical Lock Slot |
| Interface | RS232 |
| Firmware Update | Remote download via network |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Burette Capacity | 20 mL (DURAN® borosilicate glass, Class 3, UV-protected jacket) |
| Valve System | PTFE/ECTFE three-way safety valve |
| Tubing | UV-resistant FEP tubing with PTFE check valves |
| Dispensing Accuracy | ±0.03–0.07% (burette), ±0.1–0.2% (system) |
| Display | Backlit LCD (69 × 39 mm, 64 × 128 characters), auto-adjusting brightness |
| Electrode | Dual platinum electrode, polarizing voltage adjustable from 5–200 mV (default 100 mV) |
| Current Measurement Range | 0–99.9 µA, resolution 0.1 µA |
| Interfaces | Dual RS-232 ports (PC/printer + balance/expansion) |
| Calibration Modes | Pure water, certified standard, sodium tartrate dihydrate (with solvent/gas blank correction) |
| Reporting | On-screen results + printable reports (Basic, Standard, GLP-compliant) |
| Calculation Units | ppm, mg, mg/L, mg/pc |
| Stirring Speed | 50–1000 rpm |
| Power Supply | AC 230 V, 50/60 Hz, 30 VA |
| Dimensions (W × H × D) | 310 × 265 × 205 mm (including titration unit) |
| Weight | 3.2 kg |
| Compliance | DIN 12650 Part 5, EN ISO 8655-3 |
| Qualification Support | DQ/IQ/OQ/PQ documentation available on request |