Empowering Scientific Discovery

Precisa International Trading (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
ModelEM120
Maximum Capacity124 g
Readability0.001 g / 0.01%
Pan Diameter90 mm
Repeatability±0.2% (1 g sample), ±0.02% (10 g sample)
Heating SourceHalogen lamp
Temperature Range30–230 °C
Temperature Increment1 °C
Heating ModeBoost function (140% target temperature for first 3 min)
Termination CriteriaAutomatic, semi-automatic (user-defined mass change per second), or time-based (0.1–240 min)
Data Output Interval0.1–10.0 min
Stored Methods5 user-defined profiles
SecurityPassword-protected settings, physical lock slot
InterfaceRS232
Firmware UpdateNetwork-enabled via PC connection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMicromeritics
OriginUSA
ModelAutoChem II 2920
Temperature Range–110 °C to 1100 °C
Detection MethodHigh-Stability TCD (Thermal Conductivity Detector)
Gas Inlets12
Automated Valves4 × 6-port valves
Mass Flow Controllers4 (sample prep, dual carrier/reference, analysis)
Sample TubeFlowThru™ quartz, rated to 1100 °C
TCD Zone Temperature150–250 °C
Optional AccessoriesOnline MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C)
SoftwareWindows-based AutoChem software with GRAMS/32 peak processing module
Analytical ModesTPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPrecisa
OriginSwitzerland
ModelXM120
Maximum Capacity124 g
Minimum Readability0.001 g
Moisture Resolution0.01%
Pan Diameter90 mm
Repeatability±0.2% (1 g sample), ±0.02% (10 g sample)
Heating SourceHalogen Lamp
Temperature Range30–230 °C
Temperature Increment1 °C
Drying Time Range0.1–99.9 min
Termination ModesAutomatic, Semi-Automatic (Δdigit/sec or Δ%/sec), Fixed-Time
Data Output Interval0.1–10.0 min
Password ProtectionYes
Statistical FunctionsCount, Mean, Max, Min, Standard Error
InterfaceRS232
Memory50 Method Programs, 999 Test Records
Preheating30–100 °C
Multi-Stage Heating3 programmable segments (temp + time per stage)
Boost Mode140% target temp for first 3 min
Firmware UpdateRemote via network
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPrecisa
OriginSwitzerland
ModelXM60
Maximum Capacity62 g
Minimum Readability0.001 g / 0.01%
Pan Diameter90 mm
Repeatability±0.2% (1 g sample), ±0.02% (10 g sample)
Heating SourceHalogen Lamp
Temperature Range30–230 °C
Temperature Increment1 °C
Heating ModeBoost Function (140% target temp for first 3 min)
Termination ModesAutomatic, Semi-Automatic (user-defined mass change per second), Timed (0.1–240 min)
Data Output Interval0.1–10.0 min
Preset Methods5
SecurityPassword Protection, Physical Lock Slot
InterfaceRS232
Firmware UpdateRemote download via network
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCHOTT
OriginGermany
Instrument TypeVolumetric Karl Fischer Titrator
Titration Burette Capacity20 mL (DURAN® borosilicate glass, Class 3, UV-protected jacket)
Valve SystemPTFE/ECTFE three-way safety valve
TubingUV-resistant FEP tubing with PTFE check valves
Dispensing Accuracy±0.03–0.07% (burette), ±0.1–0.2% (system)
DisplayBacklit LCD (69 × 39 mm, 64 × 128 characters), auto-adjusting brightness
ElectrodeDual platinum electrode, polarizing voltage adjustable from 5–200 mV (default 100 mV)
Current Measurement Range0–99.9 µA, resolution 0.1 µA
InterfacesDual RS-232 ports (PC/printer + balance/expansion)
Calibration ModesPure water, certified standard, sodium tartrate dihydrate (with solvent/gas blank correction)
ReportingOn-screen results + printable reports (Basic, Standard, GLP-compliant)
Calculation Unitsppm, mg, mg/L, mg/pc
Stirring Speed50–1000 rpm
Power SupplyAC 230 V, 50/60 Hz, 30 VA
Dimensions (W × H × D)310 × 265 × 205 mm (including titration unit)
Weight3.2 kg
ComplianceDIN 12650 Part 5, EN ISO 8655-3
Qualification SupportDQ/IQ/OQ/PQ documentation available on request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare