- All
- Favorite
- Popular
- Most rated
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Reflectance |
| Light Source | Pulsed Xenon Lamp (CIE D65) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm |
| Bandwidth | 10 nm |
| Reflectance Range | 0–150% |
| Reflectance Resolution | 0.003% |
| Repeatability | ΔE* < 0.09 on Ceramic White Tile |
| Aperture | 44 mm (measuring), 50 mm (illumination) |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E308, DIN 5033, JIS Z 8722 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | USPRO |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp (CIE Illuminant D65) |
| Spectral Range | 350–1050 nm |
| Spectral Resolution | <2 nm |
| Bandwidth | 5 nm |
| Reflectance/Transmittance Range | 0–150% |
| Repeatability | ΔE* < 0.03 in CIE L*a*b* on certified white tile |
| Aperture Sizes | 25 mm (LAV), 13 mm (MAV), 7 mm (SAV) with auto-switching and dual-focus lens |
| UV Control | 400 nm cut-off filter, automatic UV calibration and status tracking |
| Measurement Chamber | Large transmission compartment (35.6 × 16.5 × 10.2 cm), tri-directional sliding door |
| Sample Viewing Window | Illuminated |
| Detector | 512-element silicon photodiode array with precision double-layer diffraction grating |
| Sphere Diameter | 6-inch |
| Internal Coating | Spectraflect® patented non-yellowing, abrasion-resistant coating |
| Software | EasyMatch QC (Windows-compatible) |
| Compliance | Fully supports ASTM E308, ISO 11664, CIE No. 15, USP <1061>, and GLP/GMP audit trail requirements |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | MSEZ 45/0 |
| Instrument Type | Portable |
| Optical Geometry | 0°/45° (45° illumination / 0° viewing) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm, FWHM: 10 nm |
| Reflectance Range | 0–150% |
| Repeatability | ΔE* ≤ 0.05 (CIE L*a*b* on certified white tile) |
| Aperture Sizes | 6.0 mm (SAV), 31.8 mm (LAV) |
| Detector | 256-element silicon photodiode array with precision holographic grating |
| Display | Backlit monochrome LCD with rotatable orientation |
| Data Storage | 100 standards (with tolerance limits), 800 measurements |
| Connectivity | USB |
| Power | Rechargeable lithium-ion battery pack (optional AC adapter) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZRP 6030 |
| Price | Upon Request |
| Brand | ZEHNTNER |
|---|---|
| Origin | Switzerland |
| Model | ZGM1130 |
| Measurement Angles | 20°, 60°, and 85° (user-selectable single/dual/triple-angle modes) |
| Gloss Range | 0–2000 GU |
| Resolution | 0.1 GU (0–199.9 GU), 0.2% (200–2000 GU) |
| Accuracy | ±1% of reading |
| Spot Size | 20° (Ø9.8 mm), 60° (15.5 mm × 8.4 mm), 85° (65.5 mm × 14 mm) |
| Detector | V(λ)-matched photodiode |
| Light Source | Stable LED with spectral compliance to CIE illuminant D65 |
| Power Supply | USB-powered (no internal battery) |
| Dimensions (L×W×H) | ≤150 mm × 52 mm × 71 mm |
| Weight | ≤420 g |
| Calibration Standard | BAM-certified reference tile |
| Compliance | ASTM D523, ASTM D2457, ISO 2813, EN ISO 7668, BS 3900-D6/D13, DIN 67530 |
| Brand | Zehntner |
|---|---|
| Model | ZGM1120 |
| Measurement Angles | 20° / 60° / 85° |
| Gloss Range | 0–2000 GU |
| Accuracy | ±1% of reading |
| Detector | V(λ)-matched photoreceptor |
| Light Source | White LED |
| Power Supply | USB-powered |
| Calibration Standard | BAM-certified reference standards |
| Compliance | ASTM D523, ASTM D2457, BS 3900 Part 5, BS 6161, DIN EN ISO 2813, DIN 67530, JIS Z 8741 |
| Dimensions | ≤99 × 15 × 56 mm (L×W×H) |
| Weight | ≤117 g |
| Warranty | 12 months |
| Software | Gloss Tools v3.x (Windows-based) |
| Brand | Zehntner |
|---|---|
| Origin | Switzerland |
| Model | ZGM1020 / ZGM1022 / ZGM1023 |
| Measurement Angles | 20°, 45°, 60°, 75° (configurable per model) |
| Single-Angle Modes | 20°, 45°, 60°, 75°, 85° |
| Dual-Angle Modes | 20°/60°, 20°/75°, 45°/60°, 45°/45° |
| Mirror-Surface Mode | 20° & 60° |
| Repeatability | ±0.1 GU |
| Calibration Standards Included | Medium-Gloss & High-Gloss Reference Tiles with Precision Alignment Pins |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | CQXE |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp (CIE Illuminant D65) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm, FWHM: 10 nm |
| Reflectance Range | 0–200% |
| Photometric Resolution | 0.003% |
| Repeatability | ΔE* < 0.03 in CIE L*a*b* on certified white tile |
| Aperture Sizes | 25.4 mm (standard), 9.5 mm (optional) |
| Transmission Chamber Dimensions | 35.6 × 16.5 × 10.2 cm |
| Mirror Finish Compensation | Automatic Specular Component Included/Excluded |
| Compliance | ASTM E308, ISO 7724-1, ISO 11664, CIE No. 15, DIN 5033, JIS Z 8722 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | MSEZ D/8 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm |
| FWHM Bandwidth | 10 nm |
| Repeatability | ΔE* ≤ 0.05 (CIE L*a*b* on certified white tile) |
| Aperture Sizes | 14.3 mm (SAV), 25.0 mm (LAV) |
| Photometric Range | 0–150% |
| Detector | 256-element silicon photodiode array with precision grating spectrometer |
| Display | Backlit LCD matrix, rotatable orientation |
| Data Storage | 100 standards (with tolerance limits), 800 measurements |
| Interface | USB |
| Power | Rechargeable lithium-ion battery pack (optional AC adapter) |
| Brand | Zehntner |
|---|---|
| Origin | Switzerland |
| Model | ZRM1013+RL/QD |
| Measurement Principle | CIE Standard Observer (V(λ))–weighted luminance ratio |
| Retroreflection Geometry | RL (RA = 30 m, α = 2.29°, β = 1.24°) and Qd (diffuse illumination, 0°/diffuse viewing) |
| Measurement Area | 50 × 100 mm |
| RL Range | 0–20,000 mcd·m⁻²·lx⁻¹ |
| Qd Range | 0–318 mcd·m⁻²·lx⁻¹ |
| Data Storage | 800 measurements or averaged datasets |
| Display | Backlit LCD |
| Power | Rechargeable Li-ion battery (14.4 V / 5.4 Ah) |
| Dimensions (L×W×H) | 560 × 190 × 280 mm |
| Weight | 7.1 kg (instrument only), 8.4 kg (including ZRC1013+ tripod assembly) |
| Compliance | EN 1436:2018, ASTM E1710-22, ISO 20642:2021 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TC-HIIIDPK |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TC-HIIIDPK |
| Pricing | Available Upon Request |
| Measurement Principle | Integrating Sphere (60 mm diameter) |
| Compliance | JIS K 6718, JIS K 7105, ASTM D1003 |
| Light Source | Tungsten-Halogen Lamp |
| Detector | Silicon Photodiode |
| Measuring Aperture | Ø10 mm |
| Display | Backlit LCD |
| Output | Built-in Thermal Printer |
| Measured Parameters | Total Transmittance (Tt %), Diffuse Transmittance (Td %), Specular Transmittance (Tp %), Haze (%), Max/Min/Average Statistics |
| A/D Adjustment | User-configurable reference voltage calibration |
| Power Supply | Stabilized DC source for measurement integrity |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1 |
| Measurement Range | 1.3000–1.7100 (nD) / 0.0–95.0% Brix |
| Resolution | 0.0001 (nD) / 0.1% Brix |
| Accuracy | ±0.0002 (nD) / ±0.1% Brix |
| Automatic Temperature Compensation | 5–50°C |
| Temperature Measurement Range | 5–50°C (0.1°C resolution) |
| Power Supply | 100–240 VAC, 50/60 Hz, 10 VA |
| Dimensions & Weight | 13 × 29 × 31 cm, 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-780 |
| Measurement Range | 0.0–78.0% Brix |
| Resolution | 0.1% Brix |
| Accuracy | ±0.2% Brix |
| Temperature Compensation | Automatic, 5–60 °C |
| Prism Material | Sapphire |
| Wetted Parts | SUS316 Stainless Steel |
| Output Interfaces | RS-232C, 4–20 mA analog (DC) |
| Power Supply | DC 24 V |
| Compliance | Designed for continuous industrial process monitoring in food, beverage, and chemical manufacturing environments |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 1T |
| Measurement Range | nD 1.3000–1.7000 / Brix 0.0–95.0% |
| Resolution | 0.001 (nD) / 0.5% (Brix) |
| Accuracy | ±0.0002 (nD) / ±0.1% (Brix) |
| Temperature Range | 0.0–50.0°C (Resolution: 0.1°C, Accuracy: ±0.2°C) |
| Light Source | 8 V, 0.15 A tungsten lamp |
| Power Supply | 100–240 VAC, 50/60 Hz, 6 VA |
| Dimensions & Weight | 13 × 18 × 23 cm, 3.4 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | POLAX-2L |
| Measurement Range | ±180° (angular) / ±130°Z (sucrose scale) |
| Resolution | 0.05° (0.1°Z) |
| Temperature Compensation | 5–40 °C |
| Light Source | Long-life LED with 589 nm interference filter |
| Sample Tubes | Two sets — 100 mm and 200 mm pathlength |
| Power Supply | 100–240 VAC, 50/60 Hz, 40 VA |
| Dimensions & Weight | 43 × 22 × 30 cm, 11.5 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | MASTER-M |
| Measurement Range | Brix 0.0–32.0% |
| Scale Division | 0.20% |
| Maximum Operating Temperature | 40°C |
| Prism Housing | Metal (Aluminum Alloy) |
| Optical System | Single-lens, high-transmittance eyepiece |
| Ergonomic Design | Balanced weight distribution, optimized grip geometry |
| Liquid Clearance | Rapid drainage groove on prism surface |
| Compliance | Designed per JIS K 0061 and ISO 21527-1 for refractometric sugar analysis |
Show next