Empowering Scientific Discovery

Qingdao Shenghan Chromatography Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCIC-D160Z
Instrument TypeLaboratory
Application ScopeGeneral-Purpose
Maximum Pump Pressure42 MPa
Operating Temperature Range15–60 °C
Suppressor DesignIntegrated High-Pressure Chemical Regeneration Suppressor
Eluent GenerationBuilt-in Hydroxide Eluent Generator (water-fed, current-controlled)
Column OvenIntegrated Bidirectional Thermostatic Control (15–60 °C, programmable)
Fluidic PathAll-PEEK, pH 0–14 Compatible
DetectorEmbedded Constant-Temperature Conductivity Detector with Auto-Ranging (ppb–ppm linear dynamic range)
CO₂ RemovalIntegrated Post-Suppression CO₂ Degassing Module
DegasserBuilt-in Low-Pressure Online Degasser
Suppressor ArchitectureTriple-Cartridge Rotating Suppressor (120° step rotation, acid-regenerated, real-time cartridge switching)
Suppressor Lifetime≥10 years under typical operating conditions
Organic Solvent ToleranceCompatible with high-percentage methanol and acetonitrile eluents
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelCIC-D160+ Ion Chromatograph
Instrument TypeLaboratory Benchtop
Application ScopeGeneral-Purpose Ion Analysis
Maximum Pump Pressure42 MPa
Flow Rate Range0.1–5.0 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelSH-GIC7000
Instrument TypeOnline Analyzer
Application SpecificityDedicated for Ambient Air Particulate Analysis
Pump Pressure Range0–35 MPa
Flow Rate Range0–9.999 mL/min
Eluent Flow Rate0.1–5.0 mL/min
Maximum Operating Pressure35 MPa
Operating Temperature RangeRoom Temperature +5°C to 60°C
Temperature Reproducibility±0.2°C
Eluent Concentration Range0–100 mM
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Benchtop Ion Chromatograph
Application ScopeGeneral-Purpose Anion and Cation Analysis
Maximum System Pressure42 MPa
Flow Rate Range0.1–10.0 mL/min
Eluent Flow Rate Range0.1–5.0 mL/min
Operating TemperatureAmbient
Eluent Concentration Range0.1 mM
Detection CompatibilityConductivity (CD), Electrochemical (ECD), UV-Vis, DAD, ICP-OES, AFS, MS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Instrument TypeConventional HPLC System
Flow Rate Range0.001–10.000 mL/min
Maximum Pressure42 MPa
Flow Accuracy≤0.06% RSD (ASTM D7507)
Autosampler Capacity120 positions
Injection Volume Range10–500 µL
Column Oven Temperature RangeAmbient +5°C to 65°C
UV-Vis Detection Wavelength Range190–800 nm
Data Acquisition Rate100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Benchtop Ion Chromatograph
ApplicationDedicated Multi-Ion Analysis System
Pump Maximum Pressure35 MPa (PEEK construction)
Flow Rate Range0.1–5.0 mL/min
Eluent Delivery Precision0.001–9.999 mL/min
Max Operating Pressure35 MPa (PEEK)
Operating Temperature RangeAmbient +5°C to 60°C
Temperature Reproducibility±0.2°C
Eluent Concentration Range0.1–100 mM
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable Ion Chromatograph
ModelCIC-P80
Application ScopeField-Deployable General-Purpose Inorganic Anion/Cation Analysis
Power SupplyDual-mode (AC Mains or External Power Bank, 4 h per bank, hot-swap enabled)
Sample IntroductionIntegrated Syringe-Free Suction-Based Autosampler
Fluidic ArchitectureElectrically Isolated Water/Electrical Circuit Layout with Sealed Enclosure
User Interface7-inch Capacitive Touchscreen + Optional Bluetooth Keyboard/Mouse Support
Compliance ContextDesigned for field use under ISO/IEC 17025-aligned operational practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine (SHINE)
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China-made)
ModelCIC-D500+
Instrument TypeLaboratory Benchtop System
Application ProfileSpecialized Multi-Mode Analytical Platform
Operating Temperature RangeAmbient + 5 °C to 60 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeUltra-High-Performance Liquid Chromatograph (UHPLC)
Flow Rate Range0.001–10.000 mL/min
Maximum Pressure700 bar (standard), 1000 bar (optional high-pressure configuration)
Autosampler Capacity768-well microplate or 108-position 2 mL vial tray
Column Oven Temperature Range5–85 °C
UV-Vis Detection Wavelength Range190–1000 nm
Data Acquisition Rate50–100 Hz
Gradient Formation OptionsIsocratic, Binary High-Pressure, Quaternary Low-Pressure
Pump Head OptionsInterchangeable 5 mL, 10 mL, and 50 mL heads
Detector OptionsUV/VIS, Diode Array Detector (DAD), Refractive Index Detector (RID) with Intelligent Temperature Control
System ArchitectureModular, Front-Access Design for Maintenance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Region CategoryDomestic (China)
ModelCIC-D150
Instrument TypeLaboratory Benchtop
Application ScopeGeneral-Purpose Ion Analysis
Maximum Pump Pressure35 MPa
Flow Rate Range0.001–9.999 mL/min
Eluent Flow Rate Range0.001–9.999 mL/min
Maximum Operating Pressure35 MPa
Operating Temperature RangeAmbient +5 °C to 60 °C
Temperature Reproducibility±0.2 °C
Eluent Concentration Range0.1–100 mM
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelSH-WIC5000
Instrument TypeOnline Analyzer
Application SpecificityDedicated for Water Matrix
Maximum Pump Pressure35 MPa
Flow Rate Range0–9.999 mL/min
Eluent Flow Rate0.1–5 mL/min
Maximum Operating Pressure35 MPa
Operating Temperature RangeAmbient +5 °C to 60 °C
Temperature Reproducibility±0.2 °C
Eluent Concentration Range0–100 mM
Detection Limits0.5 µg/L (as Cl⁻)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelSH-CIC3200
Instrument TypeOnline Analyzer
Pump Pressure Rating0–35 MPa
Flow Rate Range0–9.999 mL/min
Eluent Flow Rate0.1–5.0 mL/min
Maximum Operating Pressure35 MPa
Operating Temperature RangeAmbient +5°C to 60°C
Temperature Reproducibility±0.2°C
Eluent Concentration Range0.1–100 mM
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Instrument TypeLaboratory Benchtop IC System
Application ScopeUniversal
Maximum Pump Pressure42 MPa (PEEK construction)
Flow Rate Range0.1–5.0 mL/min
Eluent Flow Accuracy0.001–9.999 mL/min
Operating Temperature RangeAmbient +5 °C to 60 °C (±0.01 °C setpoint stability)
Temperature Reproducibility±0.2 °C
Eluent Concentration Range0.1–100 mM
Dual Independent ChannelsYes
Online Eluent GeneratorIntegrated
Suppressor TypeNext-generation membrane-based suppressor
Detector CompatibilityConductivity, Pulsed/Ampere, Integrative Amperometric
IC-MS & IC-ICP/MS ReadyYes
Online DegassingDual-stage (low-pressure vacuum + gas–liquid phase separation)
Pre-column Eluent Thermal BufferingYes
Post-run Auto-FlushYes
Pure Water Purification ModuleIntegrated inline deionization and particulate filtration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelCIC-D120+
Instrument TypeLaboratory Benchtop
Application ScopeGeneral-Purpose Ion Analysis
Pump Maximum Pressure42 MPa
Flow Rate Range0.001–9.999 mL/min
System Operating Pressure Limit10 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelCIC-D180H
Instrument TypeLaboratory
Application ScopeGeneral-Purpose
Maximum Pump Pressure42 MPa
Flow Rate Range0.001–15 mL/min
Maximum Operating Pressure45 MPa
Operating Temperature Range15–60 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShineCIC
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelCIC-D200E
Instrument TypeLaboratory Benchtop Ion Chromatograph
Application SpecificityDedicated for Carbohydrate (Monosaccharide, Disaccharide, Polyol) Analysis
Auto-sampler Capacity60 or 120 positions
Injection ModesFull-loop, Partial-loop, and Non-destructive (Needle-in-loop)
Detection PrinciplePulsed Amperometric Detection (PAD) with Triple-mode Electrochemical Control (DC, Pulsed, Integrated)
Column Oven IntegrationBuilt-in, Temperature-Controlled (30–60 °C, ±0.1 °C stability)
Gradient PumpMulti-channel High-Pressure Mixing System, Max Pressure: 41.4 MPa (6000 psi), pH Tolerance: 0–14, Compatible with Organic Solvents (e.g., Acetonitrile, Methanol, Ethanol)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine / SHINE
OriginShandong, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelCIC-D100
Instrument TypeLaboratory Benchtop
Application ScopeGeneral-Purpose Ion Analysis
Maximum Pump Pressure42 MPa
Flow Rate Range0.001–9.999 mL/min
Eluent Flow Rate Range0.001–9.999 mL/min
Maximum Operating Pressure42 MPa
Column Oven Temperature Range20–60 °C
Eluent Concentration Range0.01–100 mM
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShine
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelCIC-D180
Instrument TypeLaboratory Benchtop
Application ScopeUniversal Ion Analysis
Maximum Pump Pressure35 MPa
Flow Rate Range0.1–5.0 mL/min
Eluent Delivery Precision0.001–9.999 mL/min
Max Operating Pressure35 MPa
Column Oven Temperature RangeAmbient +5 °C to 60 °C ±0.01 °C
Temperature Reproducibility±0.2 °C
Eluent Concentration Range0.1–100 mM
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0