| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | THZ-C-1 |
| Quotation | USD 2,150 (FOB China) |
| Instrument Type | Refrigerated Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 20–350 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 5°C to 60°C (ambient 25°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.5°C |
| Platform Dimensions | 540 × 340 mm |
| Platform Capacity | 1000 mL × 6 or 500 mL × 10 or 250 mL × 19 (Erlenmeyer flasks) |
| Power Input | 600 W |
| Dimensions (W×D×H) | 790 × 565 × 490 mm |
| Net Weight | 56 kg |
| Voltage/Frequency | 220 V, 50 Hz |
| Illumination | 8 W LED |
| Display | LED digital |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model Series | BR |
| Instrument Type | Air-Jacketed Constant-Temperature Shaker |
| Timer Range | Programmable (varies by model) |
| Oscillation Frequency | 20–500 rpm |
| Oscillation Amplitude | 1–75 mm |
| Temperature Range | +4 °C to +100 °C (model-dependent) |
| Platform Configuration | Single or Multi-Deck Platforms |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR Series |
| Temperature Range | +4 °C to +100 °C |
| Oscillation Modes | Orbital, Reciprocating, or Switchable |
| Speed Range | 20–500 rpm |
| Amplitude | 10–50 mm |
| Timer Range | 0–99 h 59 min |
| Platform Capacity | Up to 64 × 500 mL flasks |
| Compliance | Designed for GLP-compliant labs, compatible with ISO 17025 workflows and USP <1058> analytical instrument qualification protocols |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-180LF / BR-180LF-Light / BR-180LF-70RT |
| Oscillation Mode | Orbital & Reciprocal (switchable) |
| Speed Range | 25–400 rpm |
| Amplitude | 25 mm / 50 mm (BR-180LF), 70 mm (BR-180LF-70RT) |
| Temperature Range | +4°C to +70°C (standard & 70RT), +15°C to +70°C (Light model) |
| Temp. Accuracy | ±0.3°C to ±1.0°C |
| Platform Size | 700 × 500 mm |
| Max. Load Capacity | 10 kg (excl. platform) |
| Illumination | Up to 11,000 lux (adjustable, 6 × 20 W daylight lamps) |
| Door Design | Dual-hinged clamshell (top + front access) |
| Cooling | Compressor-based (125 W) |
| Heating | 700 W resistive heater |
| Power Supply | AC 100 V, 12 A (50/60 Hz) |
| Dimensions (W×D×H) | 1110 × 716 × 990 mm (BR-180LF), 1110 × 716 × 1075 mm (Light), 1110 × 716 × 930 mm (70RT) |
| Weight | ~180 kg (BR-180LF), ~205 kg (Light), ~190 kg (70RT) |
| Compliance | Designed for GLP-compliant microbial, cell, and photobiological cultivation |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-22FP·MR |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 20–300 rpm |
| Amplitude | 25 mm |
| Temperature Range | +15°C to +60°C |
| Capacity | 6 × 500 mL Erlenmeyer flasks |
| Cooling Method | Peltier (4 × 70 W) |
| Heating Method | Peltier |
| Temperature Control Accuracy | ±0.2°C |
| Oscillation Mode | Orbital |
| Chamber Dimensions (W×D×H) | 290 × 250 × 270 mm (internal height) |
| Max Load | ~3.5 kg (including platform and fixtures) |
| Power Supply | AC 100 V, 5 A |
| Net Weight | ~49 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-300 / BR-300LF |
| Oscillation Mode | Reciprocating or Orbital (Switchable) |
| Speed Range | 25–160 rpm |
| Amplitude | 10–50 mm (adjustable) |
| Temperature Range | +10°C to +70°C (BR-300), +4°C to +70°C (BR-300LF) |
| Platform Dimensions | 600 × 400 mm |
| Internal Height | 575 mm |
| Load Capacity | ~10 kg per shelf (excl. platform) |
| Display | Digital (dual-mode: set temp / chamber temp) |
| Heating | 700 W heater |
| Cooling | Circulating chiller (BR-300) or built-in compressor (125 W, BR-300LF) |
| Timer Function | Cumulative oscillation time (0.1–999.9 h, auto-reset) |
| Safety Features | Leakage/overcurrent breaker, high-temp cutoff (compressor circuit), sensor fault diagnostics, deviation alarm (upper/lower limits) |
| Compliance | Designed for GLP-compliant labs |
| Power Supply | AC 100 V, 8 A (BR-300), 11 A (BR-300LF) |
| Net Weight | 210 kg (BR-300), 220 kg (BR-300LF) |
| Dimensions (W×D×H) | 1110 × 682 × 1120 mm |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-300 / BR-300LF / LED-Illuminated BR-300LF |
| Temperature Range | +4°C to +70°C |
| Oscillation Mode | Switchable Orbital/Reciprocating |
| Speed | 25–250 rpm |
| Amplitude | 10–50 mm (continuously adjustable) |
| Timer Range | 00h00m to 99h59m |
| Illumination | Up to 8000 lx (LED, dimmable, 24-h timer with 15-min ON/OFF steps) |
| Platform Dimensions | 600 × 400 mm |
| Max Load Capacity | 10 kg (platform excluded) |
| Heating Power | 700 W |
| Cooling | Compressor (125 W, BR-300LF & LED models) or Water-Cooled (BR-300) |
| Temp. Control Accuracy | ±0.3°C to ±1.0°C |
| Safety Features | Leakage/overcurrent protection, compressor overheat cutoff, temperature deviation alarm, sensor self-diagnosis, auto-reset cumulative oscillation timer (0.1–999.9 h) |
| Power Supply | AC 100 V, 8–12 A |
| Net Weight | 200–230 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-3000LF (Single-Tier) / Dual-Tier BR-3000LF |
| Temperature Range | +4 °C to +70 °C |
| Temperature Control Accuracy | ±0.3 °C to ±1.0 °C |
| Oscillation Mode | Switchable Orbital or Reciprocating |
| Speed Range | 25–250 rpm (Single-Tier), 25–160 rpm (Dual-Tier) |
| Amplitude | Adjustable 10–50 mm |
| Timer Range | 0.1–999.9 h |
| Platform Dimensions | 800 × 600 mm |
| Internal Chamber Height | 605 mm |
| Load Capacity | ~17 kg per tier (excluding platform) |
| Power Supply | AC 100 V, 12 A |
| Total Weight | ~310 kg (Single-Tier), ~330 kg (Dual-Tier) |
| Heating | 800 W Heater |
| Cooling | 125 W Compressor |
| Safety Features | Leakage/overcurrent breaker, compressor overheat cutoff, temperature deviation alarm, sensor self-diagnosis, sample protection circuit |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | BR-40LF, BR-41FL/MR, BR-42FL/MR, BR-43FM/MR, BR-43FH/MR |
| Shaker Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 00h00min to 99h59min |
| Oscillation Speed | 20–300 rpm |
| Orbit Diameter | 25 mm |
| Temperature Range | Ambient +5°C to +70°C (standard) |
| Platform Configuration | Single or Dual Shaking Platforms |
| Compliance | Designed for GLP-compliant microbiological and cell culture workflows per ISO 13485-aligned manufacturing standards |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model | CO2-BR Series |
| Temperature Range | +4°C to +50°C |
| Temp. Control Accuracy | ±0.3°C to ±1.0°C |
| Oscillation Mode | Reciprocating / Orbital Switchable |
| Speed Range | 20–200 rpm (CO2-BR-40LF), 25–250 rpm (CO2-BR-43FL-MR/MT), 25/50 mm (CO2-BR-180LF) |
| Amplitude | 10–40 mm (variable), 25 mm (fixed), 25/50 mm (switchable) |
| Timer Range | 0 min – 99 h 59 min |
| Gas Distribution Channels | Up to 12 branches |
| Compatible Vessels | Erlenmeyer flasks (125 mL–5 L), multiwell plates, culture bags (5–20 L) |
| Power Supply | AC 100 V ±9% / ±12% |
| Weight | 70–180 kg |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | CS-LR |
| Timer Range | 0–99 h |
| Oscillation Frequency | 15–200 rpm |
| Amplitude | 25 mm (factory-set, optional 20 mm) |
| Temperature Range | 0–50 °C |
| Platform Size | 300 × 200 mm |
| Load Capacity | ~3 kg |
| Humidity Tolerance | ≤95% RH ±5% |
| Construction | SUS304 Stainless Steel Body & KENIFINE™-Coated Platform |
| Safety | Fuse, Motor Overload Protection, Overvoltage Protection |
| Dimensions (Shaker) | 302 × 240 × 129 mm |
| Weight (Shaker) | ~7 kg |
| Power Supply | AC 100 V, 1 A |
| Control Box Dimensions/Weight | 125 × 30 × 70 mm / ~0.5 kg |
| Standard Accessories | AC adapter, reciprocal/rotary mode bar, 2-m power cable |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M·BR-034P / M·BR-034 / M·BR-032P / M·BR-032 / M·BR-104P / M·BR-104 |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Oscillation Frequency Range | 200–1600 rpm |
| Orbit Diameter | 2 mm |
| Temperature Range | Ambient −7 °C to 60 °C |
| Shelf Configuration | Dual or Quad Platform (2 or 4 interchangeable shelves) |
| Sample Compatibility | 96-well microplates, deep-well plates (e.g., 96DW), 0.5–5.0 mL microtubes, 15–50 mL centrifuge tubes (with optional platforms) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | MBR-034P / MBR-034 / MBR-032P / MBR-032 / MBR-104P / MBR-104 |
| Shaker Type | Air-jacketed Temperature-Controlled Orbital Shaker |
| Oscillation Frequency Range | 200–1600 rpm |
| Orbit Diameter | 2 mm |
| Temperature Range | Ambient −7 °C to +60 °C |
| Shelf Capacity | 2 or 4 interchangeable platforms |
| Power Efficiency | Designed for low-energy operation |
| Noise Level | <45 dB(A) at 500 rpm (typical) |
| Compliance | Supports IQ/OQ/PQ documentation per GMP/GLP requirements |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | E-36 |
| Timer Range | 5–60 min |
| Oscillation Speed | 300–1000 rpm (Low Range), 1200–2500 rpm (High Range) |
| Oscillation Mode | Horizontal Eccentric |
| Platform Dimensions | 270 × 102 mm (external) |
| Sample Capacity | 96-well microplates (up to 2 plates), 1.5 mL tubes (36 or 40, with optional holders EM-1036/EM-1040), 0.5 mL tubes (36, with EM-0836) |
| Optional Platforms | WP-9602 deep-well plate platform |
| Power Supply | AC 100–220 V, 0.3 A |
| Weight | ~5 kg |
| Certifications | CE-compliant, designed for ISO 13485-aligned laboratory environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | EP-1 |
| Instrument Type | Water Bath Shaker / Reciprocating Incubator Shaker |
| Oscillation Mode | Reciprocating |
| Speed Range | 20–160 rpm |
| Amplitude | 0–30 mm (continuously adjustable) |
| Platform Dimensions | 275 × 315 mm |
| Bath Internal Dimensions | 280 × 395 × 140 mm (W × D × H) |
| External Dimensions / Weight | 330 × 575 × 250 mm / ~14 kg |
| Power Supply | AC 100 V, 1 A |
| Max Operating Temperature | ≤80 °C (≤70 °C with plastic bath) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | G·BR-200 / G·BR-300 |
| Oscillation Frequency | 25–300 rpm |
| Oscillation Amplitude | Switchable 25 mm / 50 mm |
| Temperature Range | +4°C to +80°C |
| Platform Dimensions | 700 × 500 mm |
| Max. Capacity | 96 × 50 mL Erlenmeyer flasks (on MT-7050 platform) |
| Temperature Control Accuracy | ±0.3°C to ±1.0°C |
| Heating Power | 700 W |
| Compressor Cooling Power | 125 W |
| Power Supply | AC 100 V, 12 A |
| Net Weight | ~235 kg |
| External Dimensions (H×W×D) | 1200 × 800 × 810 mm |
| Safety Features | Over-temperature/over-current protection, compressor overheat cutoff, door-open detection, motor runaway detection, non-volatile memory error monitoring, filter check indicator |
| Programmable Memory | 4 programs × 9 steps |
| Energy Efficiency | ~25% lower power consumption vs. prior-generation units under equivalent thermal load |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M·BR-024 |
| Instrument Type | Air-jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 60-minute mechanical timer |
| Oscillation Frequency | 100–1,200 rpm |
| Oscillation Mode | Horizontal eccentric motion |
| Temperature Range | +5 °C (ambient +5 °C) to +65 °C |
| Temperature Accuracy | ±0.3–1.0 °C |
| Heating Power | 80 W |
| Platform Capacity | 4 standard microplates (e.g., 96-well) or 2 microtube clamps (e.g., EM-0836/EM-1036) |
| Display | Dual digital LED (switchable between temperature and speed) |
| Dimensions (W×D×H) | 300 × 377 × 318 mm |
| Weight | ~12 kg |
| Power Supply | AC 100 V / 2 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M·BR-420FL |
| Temperature Range | +4°C to +70°C |
| Temperature Accuracy | ±0.3°C to ±1.0°C |
| Oscillation Speed | 200–1500 rpm (reversible mode ≤1000 rpm) |
| Timer Range | 00h00m to 99h59m |
| Oscillation Mode | Horizontal eccentric motion with reversible function |
| Heating Power | 800 W |
| Cooling System | Compressor-based refrigeration (140 W) |
| Display | Digital LED for temperature and speed |
| Programmable Profiles | 4 programs × 9 steps (temperature, speed, time, hold function) |
| Dimensions (W×D×H) | 600 × 732 × 643 mm |
| Weight | ~100 kg |
| Electrical Supply | AC 100 V, 12 A |
| Platform Capacity | Up to 24 microplates (4 layers × 6 positions) or 12 deep-well plates (2 layers × 6 positions) |
| Operating Ambient Temperature | +5°C to +35°C |
| Compliance | Designed for GLP-compliant labs |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | EVR-034 / EVR-032 / EVR-104 |
| Oscillation Speed | 200–1600 rpm |
| Platform Capacity | 4 × 96-well plates or 4 × microtube fixtures |
| Power Supply | AC 100 V, 0.5 A |
| Operating Temperature Range | +5 °C to +40 °C |
| Dimensions (EVR-034) | 342 × 405 × 100 mm |
| Weight | ~10 kg |
| Safety Features | Fuse, motor overload protection, overvoltage protection |
| Compliance | Designed for 3Q qualification (IQ/OQ/PQ) in GLP/GMP environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Mix-VR / Mix-EVR |
| Oscillation Mode | Orbital (Mix-VR) / Horizontal Eccentric (Mix-EVR) |
| Speed Range | 50–500 rpm (Mix-VR), 250–2500 rpm (Mix-EVR) |
| Amplitude | 10 mm (Mix-VR), 2 mm (Mix-EVR) |
| Operating Temperature Range | 0 °C to 50 °C |
| Platform Dimensions | 300 × 200 mm (standard) |
| Max Load Capacity | ~2 kg (excl. platform & fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Weight | 12.2 kg (Mix-VR), 6.5 kg (Mix-EVR) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | MM-10, ML-10F |
| Temperature Range | Ambient +5°C to 80°C (MM-10), 0°C to 50°C (ML-10F) |
| Temperature Accuracy | ±0.02–0.1°C (MM-10), ±0.05–0.2°C (ML-10F) |
| Oscillation Mode | Reciprocating |
| Adjustable Amplitude | 10–40 mm (stepless) |
| Speed Range | 20–160 rpm |
| Platform Dimensions | 400 × 300 mm (MM-10), 530 × 365 mm (ML-10F) |
| Water Bath Capacity | ~25 L (60% fill, MM-10), ~35 L (80% fill, ML-10F) |
| Heating Power | 1.3 kW (MM-10), 800 W (ML-10F) |
| Cooling System | Integrated refrigeration unit (125 W, ML-10F only) |
| Safety Features | Dual-loop thermal cutoff, dry-run protection, overtemperature sample safeguard, sensor fault self-diagnosis, ΔT display, remote temperature setting |
| Compliance | Designed for GLP-compliant microbiological and mutagenicity assay workflows including OECD 471 and ISO 10993-3 |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | NR-1, NR-2, NR-3 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 20–200 rpm |
| Amplitude | 10–40 mm (infinitely adjustable, factory-set at 25 mm) |
| Temperature Range | 0°C to +50°C |
| Platform Quantity | 1 or 2 |
| Oscillation Modes | Reciprocal (NR-1), Orbital (NR-2), Switchable Reciprocal/Orbital (NR-3) |
| Platform Dimensions | 290 × 250 mm |
| Max Load Capacity | ~5 kg (including platform and fixtures) |
| Display | Digital speed & timer |
| Timer Resolution | 0.1 h (auto-reset function) |
| Safety Features | Motor overload protection circuit, fuse |
| Power Supply | AC 100 V, 0.5 A |
| Dimensions (W×D×H) | 355 × 355 × 160 mm |
| Weight | ~13 kg |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model | NR-150 (Single-Tier), NR-150 Dual-Tier |
| Timing Range | 0 min – 99 h 59 min |
| Oscillation Speed | 25–250 rpm (NR-150), 25–160 rpm (Dual-Tier) |
| Amplitude | 10–50 mm (infinitely adjustable) |
| Platform Dimensions | 600 × 400 mm |
| Max Load Capacity | 26 kg (including platform and fixtures) |
| Power Supply | AC 100 V, 2 A |
| Safety Features | Motor overload protection circuit, fuse |
| Weight | 73 kg (NR-150), 83 kg (Dual-Tier) |
| Dimensions (W×D×H) | 760 × 585 × 350 mm (NR-150), 760 × 585 × 789 mm (Dual-Tier) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | NR-5100 (single-layer) / Dual-Layer NR-5100 |
| Oscillation Mode | Reciprocating |
| Speed Range | 25–250 rpm (NR-5100), 25–180 rpm (dual-layer) |
| Amplitude Options | 25 / 50 / 70 mm (factory-set to 70 mm) |
| Platform Dimensions | 1200 × 860 mm |
| Load Capacity | ~36 kg per layer |
| Operating Temperature Range | +5 °C to +40 °C |
| Power Supply | AC 100 V, ≤2 A |
| Weight | ~460 kg (single), ~480 kg (dual) |
| Safety Features | Leakage circuit breaker, motor overload protection, fuse |
| Compliance | Designed for GLP-compliant bioprocess environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | NR-10, NR-20, NR-30, NR-80 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 20–200 rpm |
| Amplitude | 10–40 mm (infinitely adjustable, factory-set at 25 mm) |
| Temperature Range (when used with compatible incubators) | 0 °C to +50 °C |
| Platform Quantity | 1 or 2 |
| Platform Dimensions | 400 × 300 mm |
| Max Load Capacity | ~8 kg (including platform and fixtures) |
| Display | Digital speed & timer |
| Timing Resolution | 0.1 h (integrated digital timer with auto-reset function) |
| Safety Features | Motor overload protection circuit, fuse |
| Power Supply | AC 100 V, 0.5 A |
| Dimensions (W×D×H) | 455 × 405 × 160 mm |
| Weight | ~17–18 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Personal-11 |
| Temperature Range | Room Temp +5°C to +85°C |
| Oscillation Frequency | 20–160 rpm |
| Oscillation Amplitude | 10–40 mm (infinitely adjustable) |
| Timer Range | 0.1–999.9 h |
| Chamber Capacity | ~11 L (at 80% fill level) |
| Platform Dimensions | 220 × 310 mm |
| Construction | Stainless steel wetted parts |
| Power Supply | AC 100 V, 7 A |
| Weight | ~19 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Personal-11•SDN Combination |
| Instrument Type | Water Bath Incubator Shaker |
| Oscillation Mode | Reciprocating |
| Temperature Range | +5 °C to +70 °C |
| Temperature Uniformity | ±0.1 °C to ±0.3 °C |
| Oscillation Frequency | 20–160 rpm |
| Amplitude Adjustment | 10–40 mm (continuously variable) |
| Platform Configuration | Modular dual-platform system (shaking platform + water bath trough) |
| Timing Options | Programmable digital timer (multiple preset intervals) |
| Platform Compatibility | Interchangeable trays for flasks, tubes, microplates, and custom vessels |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | PR-12 |
| Timer Range | 60 min |
| Oscillation Speed | 20–120 rpm |
| Oscillation Angle | 5°–8° (continuously adjustable) |
| Platform Dimensions | 150 × 150 mm |
| Max Load Capacity | 800 g (including fixture) |
| Power Supply | AC 100 V, 0.5 A |
| Net Weight | ~2.5 kg |
| Footprint | 170 × 180 × 166 mm (W × D × H) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Shake-LR / Shake-XR |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 15–160 rpm (Shake-LR), 15–100 rpm (Shake-XR) |
| Amplitude | 25 mm (Shake-LR), 20 mm (Shake-XR) |
| Temperature Operating Range | 0°C to +50°C |
| Platform Configuration | Single or dual platforms |
| Platform Dimensions | 300 × 200 mm |
| Max Load Capacity | ~2 kg (including platform and fixtures) |
| Display | Optional digital speed display |
| Power Supply | AC 100 V, 0.5 A |
| Dimensions (LR) | 300 × 270 × 152 mm |
| Dimensions (XR) | 300 × 235 × 155 mm |
| Weight | 7.8 kg (LR), 7.7 kg (XR) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | Shaker (LR, XR, Mix-VR, EVR, Wave-PR, SI, SI Slim, E-36, PR-12, NR-1 to NR-5100, SR-1/2DS/2DW, TS-10/20, SR-10, VIX-100) |
| Timing Range | 0–99 h 59 min |
| Oscillation Frequency | 5–2500 rpm |
| Oscillation Amplitude | 10–70 mm |
| Temperature Control | None |
| Platform Configuration | Single or dual-layer flat platforms |