Empowering Scientific Discovery

Shandong Luchuang Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLuchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelATDS-800
Instrument TypeSingle-Stage Thermal Desorber
Automation LevelSemi-Automatic
Primary Desorption Temperature Range50–380 °C
Valve Injection Zone Temperature RangeAmbient to 220 °C
Transfer Line Temperature RangeAmbient to 220 °C
Cold Trap Temperature−30 °C
Temperature Control Accuracy< ±0.1 °C
Desorption Recovery Rate>99% (compound-dependent)
Sample Position Count1
Sample Tube Dimensions≤6.5 mm OD, ≥120 mm length
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLuchuang
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Instrument TypeDual-Stage Thermal Desorber
Automation LevelFully Automated
Primary Desorption Temp Range50–380 °C
Secondary Desorption Temp Range150–380 °C
Valve & Transfer Line Temp RangeAmbient to 260 °C / Ambient to 220 °C
Cryo-Trap Temp Range−30 to 30 °C
Temperature Control Accuracy±0.1 °C
Desorption Recovery Rate≥90%
Sample Positions20
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLuchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Sample Vial Capacity20 positions
Vial Size20 mL (10 mL optional
Sample Zone Temperature RangeAmbient to 300 °C (1 °C increment, ±0.5 °C accuracy)
Valve System Temperature RangeAmbient to 180 °C (1 °C increment, ±0.5 °C accuracy)
Transfer Line Temperature RangeAmbient to 200 °C (1 °C increment, ±0.5 °C accuracy
Pressure-Controlled Sampling Range0–0.4 MPa (continuously adjustable)
Purge Flow Rate0–400 mL/min (continuously adjustable)
PrecisionRSD ≤3% (measured with 200 ppm ethanol in water)
Dimensions420 × 248 × 380 mm
Weight~15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLuchuang
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelAHS-2036Plus
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating RangeAmbient to 260 °C
Valve Temperature Control RangeAmbient to 260 °C
Sample Loop Volume1 mL
Temperature Control Accuracy±0.1 °C
Sample Capacity30 or 36 vials
Vial Size20 mL (customizable to 10 mL)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShandong Luchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelLH-20A Smart Adsorption Tube Aging Instrument
Price RangeUSD 630–1,120 (est.)
Temperature Control RangeAmbient to 450 °C
Temperature Accuracy±1 °C
Flow Rate Adjustment Range0–3000 mL/min
Number of Tubes per Batch20 (dual 10-position configuration)
Tube Dimensions88.9 mm × 6.35 mm (3.5″ × 1/4″)
Dimensions (H×W×D)230 mm × 270 mm × 395 mm
Net Weight6.5 kg
Power Consumption<300 VA
Timer Range1 min to 999 h 59 min
Operating Environment220 VAC ±10%, 50 Hz ±0.5 Hz
Carrier Gas Pressure Limit≤0.4 MPa
Ambient Temp+5 °C to +35 °C
Relative Humidity≤85% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShandong Luchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSingle-Stage Thermal Desorber
Automation LevelFully Automated
Primary Desorption Temperature Range50–380 °C
Valve Injection Zone Temperature RangeAmbient to 260 °C
Transfer Line Temperature RangeAmbient to 220 °C
Temperature Control Accuracy±0.1 °C
Desorption Recovery Rate≥90%
Sample Position Capacity36 positions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShandong Luchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Vial Heating RangeAmbient to 260 °C
Valve Heating RangeAmbient to 260 °C
Loop Volume1 mL
Temperature Control Accuracy±0.1 °C
Vial Capacity30/36 positions
Vial Size20 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShandong Luchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Region ClassificationDomestic (China)
ModelLH-20A
Temperature Control RangeAmbient to 450 °C
Gas Flow Rate0–3000 mL/min
Tube Capacity20 tubes (dual 10-position)
Temperature Accuracy±1 °C
Timer Range1 min to 999 h 59 min
Power Consumption<300 VA
Tube Dimensions88.9 mm × 6.35 mm (3.5″ × 1/4″)
Dimensions (H×W×D)230 × 270 × 395 mm
Net Weight6.5 kg
Operating Environment220 VAC ±10%, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLuchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelATDS-8100
Instrument TypeDual-stage thermal desorber
Automation LevelSemi-automatic
Primary Desorption Temp Range50–380 °C
Valve Injection Temp RangeAmbient to 260 °C
Transfer Line Temp RangeAmbient to 220 °C
Cryo-Trap Temp Range–30 °C
Temperature Control Accuracy±0.1 °C
Desorption Recovery Rate>80%
Sample Position Count1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLuchuang
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypeGas Chromatography Autosampler
Maximum Sample Capacity60–120 vials
Minimum Injection Volume0.1–5 mL
Standard Loop Volume1000 µL
Positioning Accuracy<0.3 mm
Motion ArchitectureXYZ Three-Axis
Needle Wash ModeXYZ Three-Axis Cleaning
Integrated Purge FunctionYes
Observation WindowYes
Built-in Filtration ModuleYes