| [Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Max. Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Temp. Gradient Uniformity | ±1% (100–350 °C) |
| Programmable Steps | Up to 99 |
| Max. Run Time | 9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max. Temp. | 450 °C |
| Injector Pressure Setpoint Range | 0–1000 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Simultaneous Detectors | Up to 4 |
| Injector Configurations | Up to 3 injectors |
| Inlet Modes | Split, splitless, on-column, PTV, cool-on-column, direct injection] |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Injector Max Temp | 450 °C |
| Injector Pressure Range | 0–1000 kPa |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 kPa |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 4 simultaneously installed) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Linear Dynamic Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870T |
| Temperature Control Range | Ambient + 6°C to 399°C |
| Ramp Rate | 0.1–40°C/min |
| Cooling Time | ~6 min (300°C to 50°C) |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Voltage | 220 V ±10% |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (⁶³Ni source) |
| Max Operating Temperature (FID) | ≤450°C |
| Programmed Temperature Ramping | 8-step linear |
| Temperature Stability | ±0.1°C |
| Temperature Gradient Uniformity | ±1% (100–350°C) |
| Data Storage Capacity | 20 chromatographic methods |
| Display | 10-inch LCD with bilingual (Chinese/English) interface |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C → 100 °C in ≤3.5 min (at 25 °C ambient) |
| Temperature Accuracy | ±0.01 °C |
| Programmable Temperature Steps | ≥100 |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Linear Dynamic Range | ≥10⁷ |
| FID Operating Temperature | Up to 450 °C |
| Inlet Max Temp | 450 °C |
| Simultaneous Inlets | Up to 3 |
| Available Inlet Types | 6 configurations |
| Simultaneous Detectors | 1–3 (FID/TCD modular options) |
| TCD Dual-Channel Makeup Gas Support | Yes |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Power Industry – Transformer Oil Dissolved Gas Analysis (DGA) |
| Oven Temperature Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0.1–50°C/min |
| Cooling Time | ~3 min (200°C to 100°C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability | ±0.02°C |
| Programmable Temperature Steps | Up to 32 oven ramps |
| EPC Precision | Pressure ±0.001 psi |
| Dimensions | 400 mm × 300 mm × 400 mm (L×W×H) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Injector Max Operating Temperature | 0–450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability | ±0.02 °C |
| Programmable Temperature Ramps | Up to 20 steps |
| Number of Independent Temperature Zones | 8 |
| FID Sensitivity (n-hexadecane) | ≤1×10⁻¹² g/s |
| FID Baseline Noise | ≤2×10⁻¹⁴ A |
| FID Drift | ≤2×10⁻¹³ A/30 min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC60 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Max Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Inlet Max Temp | 450 °C |
| Inlet Pressure Range | 0–1000 kPa |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 kPa |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 4 detectors simultaneously) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Coal Mining Industry |
| Temperature Control Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0–60°C/min |
| Cooling Rate | 200°C → 100°C in ~3 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | Up to 450°C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven | Supports up to four packed columns |
| Detector Compatibility | FID, TCD, FPD, methanizer, optional MS interface |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC70 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Inlet Temperature Max | 450 °C |
| Inlet Pressure Setpoint Range | 0–1000 psi |
| Inlet Total Flow Setpoint Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Inlet Configurations | Up to 3 simultaneously installed, 6 optional inlet types |
| Detector Capacity | 1–4 modular detectors (FID, TCD, ECD, FPD, NPD) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (63Ni source) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | 0–450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C to 100 °C in ≤3.5 min (at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min (7-program segments) |
| Carrier Gas Pressure Range | 0–970 kPa (7-program segments) |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmable Temperature Steps | Up to 99 |
| Oven Time Setting Range | 0–9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–1000 psi |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Simultaneous Detectors | Up to 4 |
| Injector Ports | Up to 3 configurable ports |
| Available Injector Types | 6 modular configurations |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870 TVOC |
| Temperature Control Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870Plus |
| Temperature Control Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Stability | ±0.02 °C |
| Programmable Temperature Ramps | Up to 20 steps |
| Number of Independent Temperature Zones | 8 |
| FID Sensitivity (n-hexadecane) | ≤1×10⁻¹² g/s |
| FID Baseline Noise | ≤2×10⁻¹⁴ A/30 min |
| FID Drift | ≤2×10⁻¹³ A/30 min |
| TCD Filament Current | Up to 220 mA |
| Supported Detectors | FID, TCD, FPD, ECD, NPD |
| MS Interface | Standard预留 (MS-ready interface) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 steps |
| Carrier Gas Flow Range | 0–1200 mL/min (electronically controlled) |
| Carrier Gas Pressure Range | 0–1000 psi (electronically controlled) |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 4 detectors simultaneously installable) |
| Data System | Integrated IoT-enabled chromatography workstation with remote monitoring, audit trail, and CFR Part 11-compliant reporting modules |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient + 6 °C to 399 °C |
| Temperature Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 300 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Total Injector Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Display | 5.7″ LCD (320 × 240), Bilingual (English/Chinese) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Temperature Gradient Uniformity | ±1% (100–350 °C) |
| Programmable Temperature Steps | Up to 99 |
| Maximum Runtime per Method | 9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min (electronic flow control) |
| Carrier Gas Pressure Range | 0–1000 kPa (electronic pressure control) |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–1000 kPa |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD (modular |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Baseline Noise | ≤2×10⁻¹⁴ A |
| FID Drift | ≤1.5×10⁻¹³ A/30 min |
| FID Linear Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene) |
| TCD Noise | ≤20 µV |
| TCD Drift | ≤150 µV/30 min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC80 |
| Temperature Control Range | 20–450 °C |
| Maximum Ramp Rate | 0–60 °C/min |
| Cooling Rate | 1 °C/min (from 300 °C to 100 °C in ≤3.5 min at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Programmed Temperature Vaporizing (PTV) Support | Yes |
| Max Temperature Ramping Steps | 99 |
| Max Hold Time per Step | 6000 min |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±1% (100–350 °C) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-8890 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C to 100 °C in ≤3.5 min (at 25 °C ambient) |
| Oven Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Carrier Gas Flow Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range | 0–970 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| EPC/EFC Resolution | 0.001 psi (pressure), 0.001 mL/min (flow) |
| Supported Detectors | FID, TCD, ECD, FPD, NPD (up to 4 simultaneously) |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-9870 F |
| Price Range | USD 2,800–4,200 (FOB) |
| Operating Temperature Range | Ambient + 5°C to 400°C |
| Oven Ramp Rate | 0.1–50°C/min |
| Oven Cool-down | ~6 min (300°C to 50°C) |
| Carrier Gas Flow Control Range | 0–600 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–600 mL/min |
| Column Installation Span | 152.4 mm (6-inch standard) |
| Dimensions (L×H×W) | 520 × 480 × 500 mm |
| Net Weight | 50 kg |
| Max Power Consumption | 2500 W |
| Voltage | 220 V ±10% |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9860F |
| Temperature Control Range | Ambient +8°C to 450°C |
| Maximum Ramp Rate | 65°C/min |
| Cooling Rate | 300°C → 100°C in ≤3.5 min (at 25°C ambient) |
| Temperature Stability | ±0.01°C |
| Programmed Temperature Steps | ≥100 |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Linear Dynamic Range | ≥10⁷ |
| FID Operating Temperature | Up to 450°C |
| Detector Configurability | Simultaneous installation of 1–3 modular detectors (FID, TCD, etc.) |
| Inlet Configurations | Up to 3 inlets |
| Inlet Max Temp | 450°C |
| Electronic Pressure/Flow Control | Yes |
| Data System | Integrated IoT-enabled chromatography workstation with remote monitoring, audit trail, and GLP-compliant reporting |