- All
- Favorite
- Popular
- Most rated
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | MPC-6 |
| Test Method | ASTM D6749 (Air-Pressure Method), ASTM D97, ISO 3016 |
| Sample Volume | 4.5 mL |
| Temperature Interval | 1 °C or 2 °C |
| Repeatability | Pour Point ±1 °C (1 °C interval) / ±3 °C (3 °C interval) |
| Cooling Source | Integrated Peltier Module |
| Compliance | ASTM, ISO, GLP-ready architecture |
| Data Output | Auto-generated report with timestamped test logs |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-W |
| Temperature Range | -10°C to 160°C |
| Accuracy | ±0.1°F |
| Resolution | 0.01°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25-inch LCD |
| Power | 3V CR2032 lithium coin cell battery |
| Probe Length | 20 cm (8 in), Probe Diameter: 6.35 mm (1/4 in), Tip Diameter: 4.76 mm (3/16 in) |
| Enclosure | Aluminum housing (3.5" × 12"), silicone-sealed |
| Weight | 180 g |
| Sensor Type | 100 Ω, Class A 1/3 DIN RTD |
| Immersion Depth | 11 cm (4 in) |
| Stabilization Time in Water Bath | 14 s |
| Battery Life | 400 h at 21°C (70°F) |
| Intrinsic Safety Rating | II 2 G EEx ib IIB T4 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450, ASTM D7094, SH/T 0768 |
| Repeatability | Excellent |
| Ignition Method | Electric Arc Ignition |
| Temperature Range | −25 °C to 420 °C (standard configuration: 0 °C to 200 °C |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) |
| Cooling/Heating Technology | Patented PBT (Peltier-Based Thermoregulation) |
| Data Storage Capacity | >100,000 test reports with full audit trail |
| Power Supply | 85–264 V AC or 12 V DC |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Integrated Pollution Monitoring | CPT (Contamination Prevention Technology) |
| Optional Modules | EF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable |
| Measurement Principle | Falling-Pin Viscometry |
| Viscosity Range | 5–10⁶ cP |
| Sample Volume | 4.5 mL |
| Accuracy | ±3% (PDV-100) |
| Repeatability | ±3% |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D7483, ISO 12058-1 (for falling-body viscometry), GLP-ready workflow support |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAOIL |
| Type | Rotating Disk Electrode Optical Emission Spectrometer (RDE-OES) |
| Detection Principle | Arc Spark Optical Emission Spectrometry |
| Measurement Time | ≤30 s per sample |
| Elements Quantified | Up to 32 metallic elements |
| Detection Limit (LOD) | Sub-ppm for most elements (standard configuration) |
| Sample Types | Lubricants, fuels, coolants, process water, hydraulic fluids |
| Compliance | ASTM D6728, ASTM D6595, NB/SH/T 0865 |
| Integrated System | Built-in 10-inch color touchscreen, embedded industrial PC, automated electrode dresser, and active ventilation unit |
| Dimensions & Portability | Compact benchtop footprint |
| Sample Preparation | None required — direct liquid analysis |
| Gas Requirement | None (no carrier gas, no plasma gas) |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TFBT |
| Standards Compliance | ASTM D2068, IP 387, SH/T 0895 |
| Test Methods | Integrated Method A & Method B |
| Display | 7-inch capacitive touchscreen with real-time pressure/flow/temperature curves |
| User Interface | Step-by-step graphical guidance |
| Calibration | Fully electronic (no mechanical adjustment required) |
| Output | Integrated thermal printer |
| Temperature Control | PID-regulated heating block (ambient to 100 °C, ±0.5 °C stability) |
| Flow Measurement | High-precision mass flow sensor (range: 0–200 mL/min, resolution: 0.1 mL/min) |
| Pressure Sensing | Digital differential pressure transducer (0–1000 kPa, accuracy: ±0.5% FS) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV-HT |
| Temperature Control Range | 40 °C to 150 °C |
| Kinematic Viscosity Measurement Range | 0.5 mm²/s (cSt) to 10,000 mm²/s (cSt) |
| Compliance Standards | AASHTO T201, ASTM D2170, ASTM D445 |
| Throughput | Up to 12 samples/hour |
| Software | VISCPRO® PC (supports up to 4 instruments per workstation) |
| Sample Preheater | Adjustable |
| Waste Line Heater | Integrated |
| Solvent Inlets | Dual standard ports |
| Calibration | Single-point temperature calibration capability |
| Capillary Exchange | Tool-free, operator-performed in minutes |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ST1011 |
| Temperature Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Number of Test Positions | 6 |
| Heating Power | 2 kW |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 450 × 455 mm |
| Weight | 20 kg |
| Construction | Full stainless-steel housing |
| Compliance | ASTM D130, IP 154, ISO 2160, GB/T 5096 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERACOUNT XS |
| Instrument Type | Optical Particle Counter |
| Calibration Standard | ISO 11171, traceable to NIST |
| Particle Size Channels | 4, 6, 14, 21, 25, 30, 38, 70 µm(c) |
| Measurement Time | as fast as 30 s |
| Sample Volume | 5 mL (at 10 mL/min) or 12.5 mL (at 25 mL/min) |
| Viscosity Range | up to 1000 cSt at 22 °C |
| Operating Temperature | −10 to 50 °C |
| Sample Temperature Range | 5 to 60 °C |
| Maximum Detectable Particle Size | 230 µm |
| Compliance | ISO 4406, ISO 11171, ISO 4402, SAE AS4059 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Compliance | ASTM E2412, D2688, D7412–D7418, D7624 |
| Measurement Principle | Mid-IR Absorption Spectroscopy with Fixed-Path Transmission Cell |
| Sample Volume | 10 mL |
| Flow Path Cell Thickness | 100 µm |
| Viscosity Range | 0–2000 cSt (at 20 °C) |
| Analysis Time | 60–120 s (viscosity-dependent) |
| Warm-up Time | ≤30 s |
| Auto-sampling | Integrated precision peristaltic pump |
| Auto-cleaning | Solvent or next-sample flush |
| Display | 7-inch capacitive touchscreen |
| Connectivity | Ethernet (RJ45), USB 2.0, RS-232 |
| Data Storage | ≥3000 full spectral reports with metadata |
| Remote Access | Yes, via Ethernet-enabled diagnostic and service interface |
| Alarm Logging | Timestamped event tracking with result correlation |
| Software Compliance | Audit-trail capable |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Model | Solge EZ-LubeCheck |
| Type | Portable In-Field Oil Moisture Analyzer |
| Power | Integrated Rechargeable Battery |
| Measurement Principle | Capacitive Dielectric Spectroscopy |
| Output | % Water by Volume (v/v) and ppm (optional calibration) |
| Compliance | Designed for ISO 4406, ASTM D6304 (Karl Fischer correlation), and OEM lubrication condition monitoring protocols |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AD-7 |
| Temperature Range | 0–450 °C |
| Condenser & Receiving Chamber Cooling | Peltier-based with internal recirculating coolant |
| Temperature Resolution | 0.1 °C |
| Condenser Temp Control Range | 0–69.9 °C (±0.2 °C accuracy) |
| Receiving Chamber Temp Control Range | 0–50 °C (±0.05 °C accuracy) |
| Distillate Rate Control | 2–10 mL/min (PID-regulated, factory default 4.5 mL/min) |
| Initial Boiling Point (IBP) Detection | Infrared photoelectric sensor |
| Dry Point Detection | Manual visual or optional automatic sensor |
| Heating System | 24 V/600 W vortex-type heater with forced-air cooling |
| Safety Systems | Flame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring |
| Data Storage | 5,000 test records |
| Test Method Presets | 200 programmable modes |
| Interfaces | RS-232C, Ethernet (for TDAS/LIMS), USB |
| Display | 10.4″ capacitive touchscreen LCD |
| Atmospheric Pressure Compensation | Automatic or manual input |
| Compliance | ASTM D86, ASTM D850, ASTM D1078, GB/T 6536 |
| Software | TDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper) |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ferro-Mon Sensor |
| Product Type | Online Instrument |
| Detection Parameter | Ferrous Wear Debris Concentration |
| Output Format | Fe Saturation (%) |
| Communication Interface | LoRa Wireless |
| Compliance | PQ Standard |
| Application Domain | In-Service Lubricating Oil Monitoring for Rotating Machinery |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS-2100F |
| Instrument Type | Rotational Viscometer (Cold Cranking Simulator) |
| Temperature Range | −35 °C to −5 °C |
| Temperature Resolution & Accuracy | ±0.05 °C |
| Apparent Viscosity Range | 1,500–27,000 mPa·s |
| Compliance | ASTM D5293, SAE J300-99, GB/T 6538 |
| Cooling Method | Solid-State Thermoelectric (No Refrigerants) |
| Sample Throughput | 30 Samples per Unattended Run |
| Control System | Windows-Based PC with CCS-RA Interface and LIMS-Ready Software |
| Power Supply | 230 V / 50 Hz / 1000 W |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS S&N |
| Measurement Elements | Sulfur (S), Nitrogen (N) |
| Measurement Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Detection Limit | 5 ppb (S), 5 ppb–10% (N) |
| Quantitation Range | 10 ppb–10% (S & N) |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Display | 7-inch touchscreen interface |
| Languages | English, French, Spanish, German, Russian, Chinese |
| Compliance | ASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762 |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TC16 / TC40 / TC58 |
| Bath Volume | 16 L / 40 L / 58 L |
| Temperature Range | Ambient to 250 °C |
| Temperature Stability | ±0.02 °C |
| Circulation Type | Internal recirculation |
| Compliance | CE-marked |
| Safety Feature | Mechanical resettable safety thermostat |
| Communication Interface | RS232 |
| Software | Free Tamcom control and data logging software |
| Unit Options | °C (standard), °F (on request) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable Falling-Pin Viscometer |
| Sample Tube | Disposable 4.5 mL glass tube |
| Measurement Principle | Gravitational falling-pin (Stokes’ law-based) |
| Viscosity Range | 1–10⁸ cP |
| Temperature Control Range | 0–100 °C |
| Timing Resolution | 0.001 s |
| Pin Density Range | 6–300 g/cm³ |
| Accuracy & Repeatability | <1% |
| Interface | RS232 |
| Compliance | ASTM D1200, ISO 2555, USP <911> (for kinematic viscosity correlation) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AFP-102 |
| Standards Compliance | ASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248 |
| Cooling Method | Integrated Peltier thermoelectric module (no formaldehyde or external chiller required) |
| Temperature Range | Ambient to –60 °C |
| Temperature Resolution | 0.1 °C |
| Cooling Modes | Linear ramp and stepwise (isothermal) cooling |
| Detection Principle | Dual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket |
| Sample Compatibility | Diesel fuels, heating oils, biodiesel blends, and other middle distillates |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CAV4.1 |
| Instrument Type | Capillary Viscometer (Fixed Benchtop) |
| Kinematic Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 20–150 °C |
| Temperature Resolution & Accuracy | ±0.01 °C |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105, IP 71, GB/T 265 |
| Sample Throughput | Dual-capillary parallel measurement |
| Integrated Control | Built-in industrial PC + 10.4″ color touchscreen |
| Software | VISCPRO (supports up to 4 CAV4.1 units per host PC) |
| Cleaning & Drying | Automated solvent rinse and compressed-air drying |
| Capillary Exchange | Tool-free, bath-oil–retaining design |
| Calibration | Single-point temperature calibration per capillary |
| Status Indication | Multi-color LED status lighting |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | Aquamax KF PRO LPG |
| Application | Coulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams |
| Detection Range | 0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density) |
| Sample Form | Liquid or vapor-phase, pressurized |
| Automation Level | Fully automated sample introduction, titration, rinsing, and method execution |
| Compliance | Designed per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UHPV-100 |
| Price | Upon Request |
| Viscosity Range | 0.7–20,000 cP (mPa·s) |
| Pressure Range | Up to 60,000 psi |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~10 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 7 g/cm³ |
| Instrument Weight | 68.0 kg (150 lbs) |
| Dimensions (H×W×D) | 61 × 107 × 61 cm |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV |
| Instrument Type | Capillary Viscometer (Fixed-Station, Benchtop) |
| Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C (at setpoint) |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105 |
| Sample Volume | 5–10 mL per test |
| Bath Volume | 1 L |
| Dimensions | 254 mm (W) × 533 mm (H) × 381 mm (D) |
| Connectivity | RS-232 |
| Software | VISCPRO II (Windows 98/NT/XP compatible) |
| Multi-unit Control | Up to 4 units per PC |
| LIMS Integration | Yes |
| Operating Humidity | 10–90% RH (non-condensing) |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Type | Electromagnetic Oscillating Tribometer |
| Load Range | 1–3000 N |
| Frequency Range | 1–500 Hz |
| Oscillation Amplitude | 0.005–4 mm |
| Temperature Range | Ambient to +400 °C (optional up to +1000 °C) |
| Force Sensing | High-accuracy piezoelectric tribosensors |
| Displacement Monitoring | LVDT-based real-time closed-loop control |
| Compliance Standards | ASTM D5706, D5707, D6425, D7421, D7594, E2789 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CMRV-4500F |
| Instrument Type | Rotational Viscometer (Fixed-Mount) |
| Temperature Range | –5 °C to –40 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Method | Thermoelectric (Peltier) with Fluorine-Free Coolant Circulation |
| Compliance | ASTM D3829, D4684, D6896, D6821, SAE J300, GB/T 9171, SH/T 0562 |
| Software Platform | Windows 98/NT/XP Compatible Control System |
| Optional Accessory | Dedicated Rotor Kit for ASTM D6821 |
Show next