Add to compare
BrandTANAKA
OriginJapan
ModelMPC-6
Test MethodASTM D6749 (Air-Pressure Method), ASTM D97, ISO 3016
Sample Volume4.5 mL
Temperature Interval1 °C or 2 °C
RepeatabilityPour Point ±1 °C (1 °C interval) / ±3 °C (3 °C interval)
Cooling SourceIntegrated Peltier Module
ComplianceASTM, ISO, GLP-ready architecture
Data OutputAuto-generated report with timestamped test logs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermoprobe
OriginUSA
ModelTL1-W
Temperature Range-10°C to 160°C
Accuracy±0.1°F
Resolution0.01°C
Operating Ambient Temperature-20°C to 54°C (-4°F to 130°F)
Display0.25-inch LCD
Power3V CR2032 lithium coin cell battery
Probe Length20 cm (8 in), Probe Diameter: 6.35 mm (1/4 in), Tip Diameter: 4.76 mm (3/16 in)
EnclosureAluminum housing (3.5" × 12"), silicone-sealed
Weight180 g
Sensor Type100 Ω, Class A 1/3 DIN RTD
Immersion Depth11 cm (4 in)
Stabilization Time in Water Bath14 s
Battery Life400 h at 21°C (70°F)
Intrinsic Safety RatingII 2 G EEx ib IIB T4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERAFLASH
Detection MethodClosed-Cup
Operation ModeFully Automatic
Applicable StandardsASTM D6450, ASTM D7094, SH/T 0768
RepeatabilityExcellent
Ignition MethodElectric Arc Ignition
Temperature Range−25 °C to 420 °C (standard configuration: 0 °C to 200 °C
Sample Volume1 mL (ASTM D6450), 2 mL (ASTM D7094)
Cooling/Heating TechnologyPatented PBT (Peltier-Based Thermoregulation)
Data Storage Capacity>100,000 test reports with full audit trail
Power Supply85–264 V AC or 12 V DC
Sample ThroughputUp to 12 samples/hour
Temperature Accuracy±0.1 °C
Integrated Pollution MonitoringCPT (Contamination Prevention Technology)
Optional ModulesEF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Instrument TypePortable
Measurement PrincipleFalling-Pin Viscometry
Viscosity Range5–10⁶ cP
Sample Volume4.5 mL
Accuracy±3% (PDV-100)
Repeatability±3%
Operating EnvironmentAmbient Temperature
ComplianceASTM D7483, ISO 12058-1 (for falling-body viscometry), GLP-ready workflow support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERAOIL
TypeRotating Disk Electrode Optical Emission Spectrometer (RDE-OES)
Detection PrincipleArc Spark Optical Emission Spectrometry
Measurement Time≤30 s per sample
Elements QuantifiedUp to 32 metallic elements
Detection Limit (LOD)Sub-ppm for most elements (standard configuration)
Sample TypesLubricants, fuels, coolants, process water, hydraulic fluids
ComplianceASTM D6728, ASTM D6595, NB/SH/T 0865
Integrated SystemBuilt-in 10-inch color touchscreen, embedded industrial PC, automated electrode dresser, and active ventilation unit
Dimensions & PortabilityCompact benchtop footprint
Sample PreparationNone required — direct liquid analysis
Gas RequirementNone (no carrier gas, no plasma gas)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTamson Instruments
OriginNetherlands
ModelTFBT
Standards ComplianceASTM D2068, IP 387, SH/T 0895
Test MethodsIntegrated Method A & Method B
Display7-inch capacitive touchscreen with real-time pressure/flow/temperature curves
User InterfaceStep-by-step graphical guidance
CalibrationFully electronic (no mechanical adjustment required)
OutputIntegrated thermal printer
Temperature ControlPID-regulated heating block (ambient to 100 °C, ±0.5 °C stability)
Flow MeasurementHigh-precision mass flow sensor (range: 0–200 mL/min, resolution: 0.1 mL/min)
Pressure SensingDigital differential pressure transducer (0–1000 kPa, accuracy: ±0.5% FS)
Power Supply100–240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiAV-HT
Temperature Control Range40 °C to 150 °C
Kinematic Viscosity Measurement Range0.5 mm²/s (cSt) to 10,000 mm²/s (cSt)
Compliance StandardsAASHTO T201, ASTM D2170, ASTM D445
ThroughputUp to 12 samples/hour
SoftwareVISCPRO® PC (supports up to 4 instruments per workstation)
Sample PreheaterAdjustable
Waste Line HeaterIntegrated
Solvent InletsDual standard ports
CalibrationSingle-point temperature calibration capability
Capillary ExchangeTool-free, operator-performed in minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelST1011
Temperature RangeAmbient to 130 °C
Temperature Stability±0.2 °C
Number of Test Positions6
Heating Power2 kW
Power SupplyAC 220 V, 50 Hz
Dimensions (W×D×H)260 × 450 × 455 mm
Weight20 kg
ConstructionFull stainless-steel housing
ComplianceASTM D130, IP 154, ISO 2160, GB/T 5096
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERACOUNT XS
Instrument TypeOptical Particle Counter
Calibration StandardISO 11171, traceable to NIST
Particle Size Channels4, 6, 14, 21, 25, 30, 38, 70 µm(c)
Measurement Timeas fast as 30 s
Sample Volume5 mL (at 10 mL/min) or 12.5 mL (at 25 mL/min)
Viscosity Rangeup to 1000 cSt at 22 °C
Operating Temperature−10 to 50 °C
Sample Temperature Range5 to 60 °C
Maximum Detectable Particle Size230 µm
ComplianceISO 4406, ISO 11171, ISO 4402, SAE AS4059
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERASPEC OIL
ComplianceASTM E2412, D2688, D7412–D7418, D7624
Measurement PrincipleMid-IR Absorption Spectroscopy with Fixed-Path Transmission Cell
Sample Volume10 mL
Flow Path Cell Thickness100 µm
Viscosity Range0–2000 cSt (at 20 °C)
Analysis Time60–120 s (viscosity-dependent)
Warm-up Time≤30 s
Auto-samplingIntegrated precision peristaltic pump
Auto-cleaningSolvent or next-sample flush
Display7-inch capacitive touchscreen
ConnectivityEthernet (RJ45), USB 2.0, RS-232
Data Storage≥3000 full spectral reports with metadata
Remote AccessYes, via Ethernet-enabled diagnostic and service interface
Alarm LoggingTimestamped event tracking with result correlation
Software ComplianceAudit-trail capable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOLGE
OriginSouth Korea
ModelSolge EZ-LubeCheck
TypePortable In-Field Oil Moisture Analyzer
PowerIntegrated Rechargeable Battery
Measurement PrincipleCapacitive Dielectric Spectroscopy
Output% Water by Volume (v/v) and ppm (optional calibration)
ComplianceDesigned for ISO 4406, ASTM D6304 (Karl Fischer correlation), and OEM lubrication condition monitoring protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelAD-7
Temperature Range0–450 °C
Condenser & Receiving Chamber CoolingPeltier-based with internal recirculating coolant
Temperature Resolution0.1 °C
Condenser Temp Control Range0–69.9 °C (±0.2 °C accuracy)
Receiving Chamber Temp Control Range0–50 °C (±0.05 °C accuracy)
Distillate Rate Control2–10 mL/min (PID-regulated, factory default 4.5 mL/min)
Initial Boiling Point (IBP) DetectionInfrared photoelectric sensor
Dry Point DetectionManual visual or optional automatic sensor
Heating System24 V/600 W vortex-type heater with forced-air cooling
Safety SystemsFlame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring
Data Storage5,000 test records
Test Method Presets200 programmable modes
InterfacesRS-232C, Ethernet (for TDAS/LIMS), USB
Display10.4″ capacitive touchscreen LCD
Atmospheric Pressure CompensationAutomatic or manual input
ComplianceASTM D86, ASTM D850, ASTM D1078, GB/T 6536
SoftwareTDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOLGE
OriginSouth Korea
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFerro-Mon Sensor
Product TypeOnline Instrument
Detection ParameterFerrous Wear Debris Concentration
Output FormatFe Saturation (%)
Communication InterfaceLoRa Wireless
CompliancePQ Standard
Application DomainIn-Service Lubricating Oil Monitoring for Rotating Machinery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCCS-2100F
Instrument TypeRotational Viscometer (Cold Cranking Simulator)
Temperature Range−35 °C to −5 °C
Temperature Resolution & Accuracy±0.05 °C
Apparent Viscosity Range1,500–27,000 mPa·s
ComplianceASTM D5293, SAE J300-99, GB/T 6538
Cooling MethodSolid-State Thermoelectric (No Refrigerants)
Sample Throughput30 Samples per Unattended Run
Control SystemWindows-Based PC with CCS-RA Interface and LIMS-Ready Software
Power Supply230 V / 50 Hz / 1000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHELIOS S&N
Measurement ElementsSulfur (S), Nitrogen (N)
Measurement PrincipleUV Fluorescence (S) / Chemiluminescence (N)
Detection Limit5 ppb (S), 5 ppb–10% (N)
Quantitation Range10 ppb–10% (S & N)
Furnace Temperature RangeUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Carrier GasesO₂ (99.998%, 3 bar), Ar (99.995%, 3 bar)
Display7-inch touchscreen interface
LanguagesEnglish, French, Spanish, German, Russian, Chinese
ComplianceASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTamson Instruments
OriginNetherlands
ModelTC16 / TC40 / TC58
Bath Volume16 L / 40 L / 58 L
Temperature RangeAmbient to 250 °C
Temperature Stability±0.02 °C
Circulation TypeInternal recirculation
ComplianceCE-marked
Safety FeatureMechanical resettable safety thermostat
Communication InterfaceRS232
SoftwareFree Tamcom control and data logging software
Unit Options°C (standard), °F (on request)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Instrument TypePortable Falling-Pin Viscometer
Sample TubeDisposable 4.5 mL glass tube
Measurement PrincipleGravitational falling-pin (Stokes’ law-based)
Viscosity Range1–10⁸ cP
Temperature Control Range0–100 °C
Timing Resolution0.001 s
Pin Density Range6–300 g/cm³
Accuracy & Repeatability<1%
InterfaceRS232
ComplianceASTM D1200, ISO 2555, USP <911> (for kinematic viscosity correlation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelAFP-102
Standards ComplianceASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248
Cooling MethodIntegrated Peltier thermoelectric module (no formaldehyde or external chiller required)
Temperature RangeAmbient to –60 °C
Temperature Resolution0.1 °C
Cooling ModesLinear ramp and stepwise (isothermal) cooling
Detection PrincipleDual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket
Sample CompatibilityDiesel fuels, heating oils, biodiesel blends, and other middle distillates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCAV4.1
Instrument TypeCapillary Viscometer (Fixed Benchtop)
Kinematic Viscosity Range0.5–10,000 mm²/s (cSt)
Temperature Range20–150 °C
Temperature Resolution & Accuracy±0.01 °C
ComplianceASTM D445, ASTM D446, ISO 3104, ISO 3105, IP 71, GB/T 265
Sample ThroughputDual-capillary parallel measurement
Integrated ControlBuilt-in industrial PC + 10.4″ color touchscreen
SoftwareVISCPRO (supports up to 4 CAV4.1 units per host PC)
Cleaning & DryingAutomated solvent rinse and compressed-air drying
Capillary ExchangeTool-free, bath-oil–retaining design
CalibrationSingle-point temperature calibration per capillary
Status IndicationMulti-color LED status lighting
Power Supply100–240 VAC, 50/60 Hz
CertificationsCE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
ModelAquamax KF PRO LPG
ApplicationCoulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams
Detection Range0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density)
Sample FormLiquid or vapor-phase, pressurized
Automation LevelFully automated sample introduction, titration, rinsing, and method execution
ComplianceDesigned per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUHPV-100
PriceUpon Request
Viscosity Range0.7–20,000 cP (mPa·s)
Pressure RangeUp to 60,000 psi
Temperature Range−40 to +150 °C
Accuracy & Repeatability< ±2%
Sample Volume~10 cm³
Needle MaterialAluminum, Titanium, or Stainless Steel
Needle Density7 g/cm³
Instrument Weight68.0 kg (150 lbs)
Dimensions (H×W×D)61 × 107 × 61 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiAV
Instrument TypeCapillary Viscometer (Fixed-Station, Benchtop)
Viscosity Range0.5–10,000 mm²/s (cSt)
Temperature Range15–100 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C (at setpoint)
ComplianceASTM D445, ASTM D446, ISO 3104, ISO 3105
Sample Volume5–10 mL per test
Bath Volume1 L
Dimensions254 mm (W) × 533 mm (H) × 381 mm (D)
ConnectivityRS-232
SoftwareVISCPRO II (Windows 98/NT/XP compatible)
Multi-unit ControlUp to 4 units per PC
LIMS IntegrationYes
Operating Humidity10–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
TypeElectromagnetic Oscillating Tribometer
Load Range1–3000 N
Frequency Range1–500 Hz
Oscillation Amplitude0.005–4 mm
Temperature RangeAmbient to +400 °C (optional up to +1000 °C)
Force SensingHigh-accuracy piezoelectric tribosensors
Displacement MonitoringLVDT-based real-time closed-loop control
Compliance StandardsASTM D5706, D5707, D6425, D7421, D7594, E2789
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCMRV-4500F
Instrument TypeRotational Viscometer (Fixed-Mount)
Temperature Range–5 °C to –40 °C
Temperature Resolution±0.1 °C
Temperature Accuracy±0.1 °C
Cooling MethodThermoelectric (Peltier) with Fluorine-Free Coolant Circulation
ComplianceASTM D3829, D4684, D6896, D6821, SAE J300, GB/T 9171, SH/T 0562
Software PlatformWindows 98/NT/XP Compatible Control System
Optional AccessoryDedicated Rotor Kit for ASTM D6821