| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MC99-2 |
| Price | USD 2,850 (FOB Shanghai) |
| Wavelength | 254 nm / 280 nm |
| Timer Range | 1 s – 100 min |
| Flow Rate | 1–80 mL/min |
| Fraction Capacity | 12 mL × 100 tubes |
| Gradient Volume | 1000 mL (linear profile) |
| Column Set | Φ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm (three columns included) |
| Weight | 30 kg |
| Data Acquisition | Analog output to external recorder (XWT-S desktop chart recorder included) |
| Compliance | Designed for GLP-compliant lab environments |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | MD99-2A |
| Price | USD 3,600 (FOB Shanghai) |
| UV Detection Wavelengths | 220, 254, 280, 340 nm |
| Flow Rate Range | 0.1–10 mL/min |
| Fraction Collection | 100 tubes × 12 mL capacity |
| Timer Range | 1 s – 100 min |
| Gradient Volume Capacity | 1000 mL |
| Gradient Profile | Linear only |
| Column Set | Three stainless-steel columns (Φ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm) |
| Data Acquisition | HD-A PC interface module with real-time plotting, export (CSV, TXT), and post-run analysis |
| System Weight | 28 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | 2001-B-III |
| Instrument Category | Magnetic Bead-Based Nucleic Acid Purification |
| Automation Level | Dedicated Fully Automatic |
| Batch Sample Capacity | 100 samples |
| Sample Volume Range | 12 mL per tube |
| Fraction Collection Time Range | 1 s – 199 h 59 min 59 s |
| Wavelength Options | 214 nm, 254 nm, 280 nm |
| Flow Rate Range | 1–14,500 mL/h |
| Flow Accuracy | ±1% |
| Pump Speed Resolution | 0.1–150 rpm (bidirectional) |
| OD Detection | Triple-channel real-time A-value output (214/254/280 nm) |
| Fraction Collection Modes | Time-based, Drop-counting, Peak-threshold (0–100 mV) |
| Collection Vial Capacity | 100 × 12 mL tubes with numeric indexing |
| Column Compatibility | Direct interface with GE Healthcare AKTA-scale prepacked columns (1.0×50 cm, 1.0×70 cm, 2.6×50 cm included) |
| System Control | Embedded microprocessor with blue-membrane LCD display |
| Software | PC-based chromatogram acquisition, peak integration, relative quantitation, and report generation (AUC-based normalization) |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | MA99-1 |
| Wavelength | 254 nm & 280 nm |
| Flow Rate | 0.1–10 mL/min |
| Timer Range | 1 min–24 h |
| Fraction Collection Capacity | 12 mL × 100 |
| Column Set | Φ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm |
| Detection Principle | UV Absorbance (A) & Transmittance (T%) |
| Data Acquisition | Real-time spectral plotting, parameter calculation, and report export via PC-based software |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC99-3 |
| Price | USD 4,280 (FOB Shanghai) |
| UV Wavelengths | 220, 254, 280, 340 nm |
| Fraction Collection Capacity | 100 × 12 mL tubes |
| Timing Range | 1 s – 9999 min |
| Droplet Counting Range | 1–9999 drops |
| Peak Detection Range | 0–100 mV |
| Gradient Volume | 1000 mL (linear profile only) |
| Pump Flow Rate | 1–80 mL/min |
| Peristaltic Pump Speed | 0.1–100 rpm |
| Column Set | Φ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm |
| System Weight | 32 kg |