Empowering Scientific Discovery

Shanghai Chuding Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelMC99-2
PriceUSD 2,850 (FOB Shanghai)
Wavelength254 nm / 280 nm
Timer Range1 s – 100 min
Flow Rate1–80 mL/min
Fraction Capacity12 mL × 100 tubes
Gradient Volume1000 mL (linear profile)
Column SetΦ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm (three columns included)
Weight30 kg
Data AcquisitionAnalog output to external recorder (XWT-S desktop chart recorder included)
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
ModelMD99-2A
PriceUSD 3,600 (FOB Shanghai)
UV Detection Wavelengths220, 254, 280, 340 nm
Flow Rate Range0.1–10 mL/min
Fraction Collection100 tubes × 12 mL capacity
Timer Range1 s – 100 min
Gradient Volume Capacity1000 mL
Gradient ProfileLinear only
Column SetThree stainless-steel columns (Φ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm)
Data AcquisitionHD-A PC interface module with real-time plotting, export (CSV, TXT), and post-run analysis
System Weight28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
Model2001-B-III
Instrument CategoryMagnetic Bead-Based Nucleic Acid Purification
Automation LevelDedicated Fully Automatic
Batch Sample Capacity100 samples
Sample Volume Range12 mL per tube
Fraction Collection Time Range1 s – 199 h 59 min 59 s
Wavelength Options214 nm, 254 nm, 280 nm
Flow Rate Range1–14,500 mL/h
Flow Accuracy±1%
Pump Speed Resolution0.1–150 rpm (bidirectional)
OD DetectionTriple-channel real-time A-value output (214/254/280 nm)
Fraction Collection ModesTime-based, Drop-counting, Peak-threshold (0–100 mV)
Collection Vial Capacity100 × 12 mL tubes with numeric indexing
Column CompatibilityDirect interface with GE Healthcare AKTA-scale prepacked columns (1.0×50 cm, 1.0×70 cm, 2.6×50 cm included)
System ControlEmbedded microprocessor with blue-membrane LCD display
SoftwarePC-based chromatogram acquisition, peak integration, relative quantitation, and report generation (AUC-based normalization)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Technology
OriginShanghai, China
ModelMA99-1
Wavelength254 nm & 280 nm
Flow Rate0.1–10 mL/min
Timer Range1 min–24 h
Fraction Collection Capacity12 mL × 100
Column SetΦ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm
Detection PrincipleUV Absorbance (A) & Transmittance (T%)
Data AcquisitionReal-time spectral plotting, parameter calculation, and report export via PC-based software
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelMC99-3
PriceUSD 4,280 (FOB Shanghai)
UV Wavelengths220, 254, 280, 340 nm
Fraction Collection Capacity100 × 12 mL tubes
Timing Range1 s – 9999 min
Droplet Counting Range1–9999 drops
Peak Detection Range0–100 mV
Gradient Volume1000 mL (linear profile only)
Pump Flow Rate1–80 mL/min
Peristaltic Pump Speed0.1–100 rpm
Column SetΦ1.0×40 cm, Φ1.6×50 cm, Φ2.5×60 cm
System Weight32 kg
Show next