BrandChu Ding
OriginShanghai, China
ModelUV756CRT
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability0.2 nm
Spectral Bandwidth2 nm
Photometric Accuracy (Transmittance)±0.5% T
Photometric Repeatability (Transmittance)0.2% T
Transmittance Range0.0–125% T
Absorbance Range−0.031 to 3.0 A
Concentration Display Range0–1999
Stray Light≤0.05% T at 220 nm and 340 nm
Baseline Flatness±0.002 A (200–1000 nm)
Drift±0.001 A/h (at 500 nm, after 2 h warm-up)
Noise±0.001 A (at 500 nm, after 30 min warm-up)
RS232 InterfaceYes
Printer SupportIntegrated
Software CompatibilityPC-based data acquisition and analysis software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChuDing
OriginShanghai, China
ModelUV1900
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability0.2 nm
Spectral Bandwidth2 nm
Stray Light≤0.05% T (at 220 nm, NaI solution)
Photometric Range–3 to +3 A
Photometric Accuracy±0.3% T (0–100% T)
Photometric Repeatability0.001 Abs (0–0.5 Abs)
Baseline Flatness≤±0.0005 A
Noise≤0.0003 Abs/h
Drift≤±0.0004 Abs/h
Display5.1-inch 320×240 dot-matrix LCD
Power SupplyAC 220 V/50 Hz or AC 110 V/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding
ModelUV762
Wavelength Range190–1100 nm
Spectral Bandwidth2 nm
Wavelength Accuracy≤ ±0.3 nm (auto-calibrated at startup)
Wavelength Repeatability≤ 0.2 nm
Photometric Accuracy±0.5% T
Photometric Repeatability≤ 0.2% T
Transmittance Range0–200% T
Absorbance Range−0.301 to 3.000 A
Stray Light≤ 0.15% T (at 220 nm, measured with NaI)
Baseline Drift≤ 0.004 A/h (at 500 nm)
Noise≤ 0.15% T (100% line), ≤ 0.10% T (0% line)
Scan Speed ModesFast / Medium / Slow
Light SourceAutomatically Switching Deuterium & Tungsten Lamps
DisplayLarge-Screen LED-Based Chinese GUI Interface
Data ProcessingMulti-wavelength (1–3 λ), Kinetic Analysis, Polynomial Curve Fitting (1st–3rd order), Derivative Spectra (1st–4th order), Spectral Storage/Export/Print
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Technology
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelUV752N
PriceUSD 1,400 (FOB Shanghai)
Optical SystemCzerny-Turner monochromator with 1200 lines/mm grating
Wavelength Range195–1020 nm
Spectral Bandwidth4 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability≤1.0 nm
Photometric Range0–199.0% T, –0.3–1.999 A, 0–1999 C
Photometric Accuracy±0.5% T
Photometric Repeatability±0.3% T
Optical Path Length10 mm (standard cuvette)
Stray Light≤0.5% T at 220 nm
Baseline Stability±0.004 A/h at 500 nm (after 60-min warm-up)
Display4-digit LCD
Data InterfaceRS-232C serial port
Light Sources6 V/10 W halogen tungsten lamp (Philips) and deuterium lamp (long-life imported)
Power Supply110–220 V AC, 50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Technology
OriginShanghai, China
ModelUV759CRT / UV759
Wavelength Range190–1100 nm
Spectral Bandwidth1.8 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.2 nm
Photometric Accuracy±0.3% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A)
Photometric Repeatability≤0.2% T (0–100% T), ±0.001 A (0–0.5 A), ±0.002 A (0.5–1 A)
Stray Light≤0.05% T @ 220 nm and 360 nm
Baseline Flatness±0.002 A
Drift±0.002 A/h @ 500 nm
Noise±0.001 A
DetectorImported silicon photodiode
Light SourcesLong-life imported deuterium lamp and tungsten-halogen lamp
Display128 × 64 dot-matrix LCD
Measurement ModesTransmittance (T), Absorbance (A), Concentration (C)
Wavelength SettingAutomatic
Optical PathSingle-beam with automatic source switching
Data InterfaceUSB port
Print InterfaceParallel port
Power SupplyAC 220 V / 50 Hz or AC 110 V / 60 Hz
Net Weight14 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Tech
OriginShanghai, China
Model7230G
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range320–1100 nm
Wavelength Accuracy±0.5 nm
Spectral Bandwidth2 nm
Stray Light≤0.05% T @ 360 nm
Wavelength Repeatability0.2 nm
Photometric Accuracy±0.3% T
Photometric Repeatability±0.2% T
Baseline Linearity≤0.2% T
Drift≤0.001 A/h @ 500 nm
Noise≤0.1% T
Photometric Range0–200% T, −0.301–3.000 A
Light SourceImported Tungsten Lamp
Weight12 kg
InterfaceRS-232 (optional), USB, Parallel Port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Tech
OriginShanghai, China
Model722N
Wavelength Range320–1020 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability≤1 nm
Spectral Bandwidth4 nm
Photometric Accuracy±0.5% T
Transmittance Range0–100% T
Absorbance Range−0.097 to 1.99 A
Concentration Range0–1999 C (or F)
Stray Light≤0.3% T at 340 nm
Baseline Stability≤0.004 A/h at 500 nm (after 1 h warm-up)
Optical Path Length100 mm
Light Source6 V, 10 W imported tungsten lamp
Display4-digit LCD
Data InterfaceRS-232C standard port
Power Supply220 V / 110 V AC, 50–60 Hz
Net Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Technology
OriginShanghai, China
ModelUV754N
Optical DesignSingle-beam
Detector TypePhotomultiplier Tube (PMT)
Wavelength Range190–1100 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability0.5 nm
Spectral Bandwidth4 nm
Stray Light≤0.3% T at 220 nm and 360 nm
Photometric Accuracy±0.5% T
Photometric Repeatability±0.2% T
Absorbance Range–0.030 to 3.0 A
Transmittance Range0.0–200% T
Baseline Stability±0.002 A/h
Display128 × 64 dot-matrix LCD
InterfaceRS-232C serial port
Data OutputIntegrated thermal printer interface
Software SupportUV754PC quantitative analysis software suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding
OriginShanghai, China
ModelUV1900PC / UV1901PC
Wavelength Range190–1100 nm
Light SourceImported Tungsten Lamp & Deuterium Lamp
Optical SystemDual-Beam, 1200-line/mm Plane Grating
Wavelength Accuracy≤ ±0.3 nm
Wavelength Repeatability≤ 0.1 nm
Stray Light≤ 0.05 %T (at 220 nm, NaI solution)
Photometric Range–3 to +3 A
Noise≤ 0.0003 Abs/h
Baseline Flatness≤ ±0.0005 A
Spectral Bandwidth2 nm (UV1900PC), 1 nm (UV1901PC)
Drift≤ ±0.0004 Abs/h
Photometric Accuracy±0.3 %T (0–100 %T)
Photometric Repeatability0.001 Abs (0–0.5 Abs)
DetectorImported Silicon Photodiode
Power SupplyAC 220 V/50 Hz or AC 110 V/60 Hz
Dimensions658 × 468 × 264 mm
Weight30 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Technology
OriginShanghai, China
ModelV729
Optical SystemSingle-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range320–1100 nm
Wavelength Accuracy±0.5 nm
Spectral Bandwidth2 nm
Stray Light≤0.05% T
Wavelength Repeatability≤0.2 nm
Photometric Accuracy≤±0.3% T
Photometric Repeatability≤±0.1% T
Baseline Linearity±0.002 A
Noise0.001 A (at 500 nm)
Drift±0.001 A/h (at 500 nm)
Sample CompartmentAccepts Cuvettes from 5 mm to 100 mm Pathlength
Display320 × 240 Pixel High-Brightness LCD
Data InterfaceUSB 2.0
Lamp SourcesImported Tungsten and Deuterium Lamps
Power SupplyAC 220 V/50 Hz or AC 110 V/60 Hz
Net Weight16 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding
OriginShanghai, China
ModelUV755B
Wavelength Range190–1100 nm
Wavelength Accuracy±1 nm
Spectral Bandwidth2 nm
Wavelength Repeatability0.5 nm
Stray Light≤0.1%T at 220 nm and 360 nm
Photometric Accuracy±0.5%T
Photometric Repeatability±0.2%T
Baseline Stability±0.002 A/h at 500 nm
Measurement ModesTransmittance (T), Absorbance (A), Concentration (C)
Display128 × 64 dot-matrix LCD
Sample CompartmentAccommodates cuvettes from 5 mm to 100 mm pathlength
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelUV757CRT
PriceUSD 3,600 (FOB Shanghai)
Wavelength Range200–1100 nm
Light SourcesImported 12 V/20 W Tungsten-Halogen Lamp & Imported Deuterium Lamp
DetectorImported Photocell
Spectral Bandwidth3 nm
Wavelength Accuracy±0.3 nm (auto-calibrated at startup)
Wavelength Repeatability≤0.2 nm
Stray Light≤0.15% T (at 220 nm and 340 nm)
Transmittance Range0.0–200.0% T
Absorbance Range–0.301 to 4.000 A
Concentration Readout Range0000–9999 (arbitrary units)
Transmittance Accuracy±0.5% T (verified against NIST-traceable NBS 930D standard filter)
Transmittance Repeatability≤0.2% T
Noise≤0.5% T (100% T), ≤0.2% T (0% T)
Drift≤0.004 A / 30 min
Baseline Linearity±0.004 A
Power SupplyAC 220 V ±22 V, 50 Hz ±1 Hz
Dimensions520 × 410 × 200 mm (W × D × H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChu Ding Technology
OriginShanghai, China
ModelVIS-722N
Optical SystemAchromatic Czerny-Turner with 1200 lines/mm grating
Wavelength Range320–1020 nm
Wavelength Accuracy±2 nm
Spectral Bandwidth4 nm
Stray Light≤0.05% T at 360 nm
Photometric Accuracy±0.3% T
Photometric Repeatability±0.2% T
Baseline Drift≤0.1% T/h
Noise Level≤0.2% T
Stability±0.003 A/h at 500 nm
Wavelength DriveManual
Detector TypePhotodiode Array
Light SourceImported Tungsten Halogen Lamp
Net Weight8 kg
Beam TypeSingle-beam
Data OutputOptional RS-232 or USB print interface
Software SupportNone
Added to wishlistRemoved from wishlist 0
Add to compare
KeyOptical System: Czerny-Turner monochromator with 1200 lines/mm grating
Wavelength Range195–1020 nm
Spectral Bandwidth5 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability±1.0 nm
Photometric Range0–199.0% T, 0–1.999 A, 0–1999 C
Photometric Accuracy±0.5% T
Photometric Repeatability±0.3% T
Stray Light≤0.3% T at 220 nm
Baseline Stability±0.004 A/h at 500 nm (after 60-min warm-up)
Display4-digit LCD
Output InterfaceRS-232C
Light Sources6 V / 10 W halogen lamp and deuterium lamp
Power Supply110–220 V AC, 50–60 Hz
Standard Cuvette Pathlength10 mm (100 mm optional)
Show next