BrandHOGON
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC1860Ⅱ
Temperature Control Range4 °C to 450 °C
Ramp Rate0.1–39 °C/min (standard)
Cooling Rate40 °C/min
Carrier Gas Flow Range & Control0–500 mL/min
Carrier Gas Pressure Range & Control0–300 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–300 kPa
Injector Total Flow Setting Range200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC-1860
Temperature Control Range8 °C above ambient to 450 °C (1 °C increment, ±0.1 °C accuracy)
Ramp Rate0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed)
Cooling Rate~6 min (450 °C → 50 °C)
Carrier Gas Flow Control0–1200 mL/min (7 programmable segments)
Carrier Gas Pressure Control0–970 kPa (7 programmable segments)
Injector Max Temp450 °C
Injector Pressure Range0–970 kPa
Injector Total Flow Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC1860III
Temperature Control Range4 °C to 450 °C
Oven Ramp Rate0.1–39 °C/min
Oven Cooling Rate40 °C/min
Carrier Gas Flow Range & Control0–500 mL/min
Carrier Gas Pressure Range & Control0–300 kPa
Injector Max Operating Temperature450 °C
Injector Pressure Setpoint Range0–300 kPa
Injector Total Flow Setpoint Range200 mL/min
Temperature Zones6 independent zones
Max Programmed Temperature Steps16
Max Ramp Rate (with auxiliary heating)80 °C/min
Detector CompatibilityFID, TCD, ECD, FPD, NPD (up to 3 simultaneously)
Electronic Pressure Control (EPC)Yes, dual-mode (constant pressure / constant flow)
Supported GasesN₂, H₂, Air, He, Ar
Communication Interface10/100 M Adaptive Ethernet with embedded TCP/IP stack
Modbus/TCP & Profibus-DP Protocol SupportYes
SoftwareSTI-netChrom (supports up to 253 instruments, DCS integration via built-in Modbus/TCP server)
DisplayVacuum Fluorescent Display (VFD), bilingual (English/Chinese)
Auto-Start SchedulingYes
Auto-sampler InterfaceStandard RS-232 and TTL trigger support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Gas Chromatograph
Application FieldHigh-Purity Gas Analysis
Oven Temperature Range0–399 °C
Maximum Ramp Rate40 °C/min
Cooling Rate30 °C/min
Carrier Gas Flow Range & Control0–200 mL/min
Carrier Gas Pressure Range & Control0–0.4 MPa
Injector Maximum Operating Temperature399 °C
Injector Pressure Setting Range0–0.4 MPa
Injector Total Flow Setting Range0–200 mL/min
Detection Limit (FID)≤1×10⁻¹¹ g/s
Baseline Noise (FID)≤5×10⁻¹⁴ A
Drift (FID)≤1×10⁻¹³ A/30 min
Linear Dynamic Range≥10⁶
Programmable Temperature Steps8-stage
Relative Humidity Limit≤85%
Operating Ambient Temperature+5 °C to +35 °C
Power SupplyAC 220 V ±22 V, 50 Hz ±0.5 Hz, 10 A
Power Consumption≤1500 W
Dimensions (H×W×D)490×730×490 mm
Net Weight~48 kg