| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1860Ⅱ |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–39 °C/min (standard) |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–300 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–300 kPa |
| Injector Total Flow Setting Range | 200 mL/min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-1860 |
| Temperature Control Range | 8 °C above ambient to 450 °C (1 °C increment, ±0.1 °C accuracy) |
| Ramp Rate | 0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed) |
| Cooling Rate | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control | 0–970 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Range | 0–970 kPa |
| Injector Total Flow Range | 0–1200 mL/min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1860III |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Oven Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–300 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–300 kPa |
| Injector Total Flow Setpoint Range | 200 mL/min |
| Temperature Zones | 6 independent zones |
| Max Programmed Temperature Steps | 16 |
| Max Ramp Rate (with auxiliary heating) | 80 °C/min |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously) |
| Electronic Pressure Control (EPC) | Yes, dual-mode (constant pressure / constant flow) |
| Supported Gases | N₂, H₂, Air, He, Ar |
| Communication Interface | 10/100 M Adaptive Ethernet with embedded TCP/IP stack |
| Modbus/TCP & Profibus-DP Protocol Support | Yes |
| Software | STI-netChrom (supports up to 253 instruments, DCS integration via built-in Modbus/TCP server) |
| Display | Vacuum Fluorescent Display (VFD), bilingual (English/Chinese) |
| Auto-Start Scheduling | Yes |
| Auto-sampler Interface | Standard RS-232 and TTL trigger support |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 0–399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 30 °C/min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Detection Limit (FID) | ≤1×10⁻¹¹ g/s |
| Baseline Noise (FID) | ≤5×10⁻¹⁴ A |
| Drift (FID) | ≤1×10⁻¹³ A/30 min |
| Linear Dynamic Range | ≥10⁶ |
| Programmable Temperature Steps | 8-stage |
| Relative Humidity Limit | ≤85% |
| Operating Ambient Temperature | +5 °C to +35 °C |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz, 10 A |
| Power Consumption | ≤1500 W |
| Dimensions (H×W×D) | 490×730×490 mm |
| Net Weight | ~48 kg |