Empowering Scientific Discovery

Shanghai Hogon Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC1860Ⅱ
Temperature Control Range4 °C to 450 °C
Ramp Rate0.1–39 °C/min (standard)
Cooling Rate40 °C/min
Carrier Gas Flow Range & Control0–500 mL/min
Carrier Gas Pressure Range & Control0–300 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–300 kPa
Injector Total Flow Setting Range200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC-1860
Temperature Control Range8 °C above ambient to 450 °C (1 °C increment, ±0.1 °C accuracy)
Ramp Rate0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed)
Cooling Rate~6 min (450 °C → 50 °C)
Carrier Gas Flow Control0–1200 mL/min (7 programmable segments)
Carrier Gas Pressure Control0–970 kPa (7 programmable segments)
Injector Max Temp450 °C
Injector Pressure Range0–970 kPa
Injector Total Flow Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelHG-330
Instrument TypeFast Liquid Chromatography (FLC) Compatible Column Oven
Flow Rate Range0.001 mL/min
Maximum Pressure Rating40 MPa
Sample Vial Capacity100 positions (1.5 mL vials)
Injection Volume Range50 µL
Temperature Control Range10 °C to 60 °C
Wavelength Range700 nm
Data Acquisition Frequency100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC1860III
Temperature Control Range4 °C to 450 °C
Oven Ramp Rate0.1–39 °C/min
Oven Cooling Rate40 °C/min
Carrier Gas Flow Range & Control0–500 mL/min
Carrier Gas Pressure Range & Control0–300 kPa
Injector Max Operating Temperature450 °C
Injector Pressure Setpoint Range0–300 kPa
Injector Total Flow Setpoint Range200 mL/min
Temperature Zones6 independent zones
Max Programmed Temperature Steps16
Max Ramp Rate (with auxiliary heating)80 °C/min
Detector CompatibilityFID, TCD, ECD, FPD, NPD (up to 3 simultaneously)
Electronic Pressure Control (EPC)Yes, dual-mode (constant pressure / constant flow)
Supported GasesN₂, H₂, Air, He, Ar
Communication Interface10/100 M Adaptive Ethernet with embedded TCP/IP stack
Modbus/TCP & Profibus-DP Protocol SupportYes
SoftwareSTI-netChrom (supports up to 253 instruments, DCS integration via built-in Modbus/TCP server)
DisplayVacuum Fluorescent Display (VFD), bilingual (English/Chinese)
Auto-Start SchedulingYes
Auto-sampler InterfaceStandard RS-232 and TTL trigger support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelSTI5000
Instrument TypeConventional HPLC System
Flow Rate Range0.003–9.999 mL/min (adjustable in 0.001 mL/min increments)
Maximum Pressure5400 psi
Injection ModeManual (Reodyne 7725i injector)
Standard Injection Volume20 µL
Column Oven Temperature RangeAmbient to 60 °C
UV-Vis Wavelength Range190–700 nm (extendable to 850 nm)
Data Acquisition Rate20 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVERTEX
ModelSTI500
Instrument TypeIsocratic HPLC System
Flow Rate Range0.003–9.999 mL/min
Maximum Operating Pressure42 MPa
Injection Volume Range0.1–100 µL
Number of Injection Positions1
Wavelength Range (UV-Vis Detector)190–700 nm
Data Acquisition Rate100 Hz
Column Temperature ControlAmbient Only
ComplianceASTM D4294, ISO 13877, USP <621>, GLP/GMP-ready software architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVertex
OriginShanghai, China
ModelVERTEX VI500
Instrument TypeConventional HPLC System
Flow Rate Range0.001–9.999 mL/min
Max Operating Pressure40 MPa
Injection Volume Range1–5000 µL (1 µL increment
Column Oven Temperature Range4–85 °C
UV Detector Wavelength Range190–720 nm (D₂ lamp), up to 940 nm with optional W lamp
Data Acquisition Rate100 Hz
Baseline Noise (UV)≤ ±0.2 × 10⁻⁵ AU (empty cell)
Wavelength Accuracy±1 nm
Wavelength Precision< 0.1 nm
RI Detector Refractive Index Range1.00–1.75
RI Detector Noise≤ 2.5 nRIU
Sample Capacity2 × 48 vials (2 mL), optional 96-/384-well plates
Auto-sampler Cycle Time17 s (injection only), 60 s including needle wash
Injection Reproducibility (full-loop)RSD < 0.3%
Column Oven Temp Stability±0.1 °C
Power SupplyAC 110/220 V, 50/60 Hz
Dimensions (W×D×H)260 × 360 × 170 mm
Weight10.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHOGON
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Gas Chromatograph
Application FieldHigh-Purity Gas Analysis
Oven Temperature Range0–399 °C
Maximum Ramp Rate40 °C/min
Cooling Rate30 °C/min
Carrier Gas Flow Range & Control0–200 mL/min
Carrier Gas Pressure Range & Control0–0.4 MPa
Injector Maximum Operating Temperature399 °C
Injector Pressure Setting Range0–0.4 MPa
Injector Total Flow Setting Range0–200 mL/min
Detection Limit (FID)≤1×10⁻¹¹ g/s
Baseline Noise (FID)≤5×10⁻¹⁴ A
Drift (FID)≤1×10⁻¹³ A/30 min
Linear Dynamic Range≥10⁶
Programmable Temperature Steps8-stage
Relative Humidity Limit≤85%
Operating Ambient Temperature+5 °C to +35 °C
Power SupplyAC 220 V ±22 V, 50 Hz ±0.5 Hz, 10 A
Power Consumption≤1500 W
Dimensions (H×W×D)490×730×490 mm
Net Weight~48 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0