- All
- Favorite
- Popular
- Most rated
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1860Ⅱ |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–39 °C/min (standard) |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–300 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–300 kPa |
| Injector Total Flow Setting Range | 200 mL/min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-1860 |
| Temperature Control Range | 8 °C above ambient to 450 °C (1 °C increment, ±0.1 °C accuracy) |
| Ramp Rate | 0.1–39 °C/min (standard), 0.1–80 °C/min (high-speed) |
| Cooling Rate | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control | 0–970 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Range | 0–970 kPa |
| Injector Total Flow Range | 0–1200 mL/min |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HG-330 |
| Instrument Type | Fast Liquid Chromatography (FLC) Compatible Column Oven |
| Flow Rate Range | 0.001 mL/min |
| Maximum Pressure Rating | 40 MPa |
| Sample Vial Capacity | 100 positions (1.5 mL vials) |
| Injection Volume Range | 50 µL |
| Temperature Control Range | 10 °C to 60 °C |
| Wavelength Range | 700 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1860III |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Oven Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–300 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–300 kPa |
| Injector Total Flow Setpoint Range | 200 mL/min |
| Temperature Zones | 6 independent zones |
| Max Programmed Temperature Steps | 16 |
| Max Ramp Rate (with auxiliary heating) | 80 °C/min |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously) |
| Electronic Pressure Control (EPC) | Yes, dual-mode (constant pressure / constant flow) |
| Supported Gases | N₂, H₂, Air, He, Ar |
| Communication Interface | 10/100 M Adaptive Ethernet with embedded TCP/IP stack |
| Modbus/TCP & Profibus-DP Protocol Support | Yes |
| Software | STI-netChrom (supports up to 253 instruments, DCS integration via built-in Modbus/TCP server) |
| Display | Vacuum Fluorescent Display (VFD), bilingual (English/Chinese) |
| Auto-Start Scheduling | Yes |
| Auto-sampler Interface | Standard RS-232 and TTL trigger support |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | STI5000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.003–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Maximum Pressure | 5400 psi |
| Injection Mode | Manual (Reodyne 7725i injector) |
| Standard Injection Volume | 20 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–700 nm (extendable to 850 nm) |
| Data Acquisition Rate | 20 Hz |
| Brand | VERTEX |
|---|---|
| Model | STI500 |
| Instrument Type | Isocratic HPLC System |
| Flow Rate Range | 0.003–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Injection Volume Range | 0.1–100 µL |
| Number of Injection Positions | 1 |
| Wavelength Range (UV-Vis Detector) | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Column Temperature Control | Ambient Only |
| Compliance | ASTM D4294, ISO 13877, USP <621>, GLP/GMP-ready software architecture |
| Brand | Vertex |
|---|---|
| Origin | Shanghai, China |
| Model | VERTEX VI500 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | 40 MPa |
| Injection Volume Range | 1–5000 µL (1 µL increment |
| Column Oven Temperature Range | 4–85 °C |
| UV Detector Wavelength Range | 190–720 nm (D₂ lamp), up to 940 nm with optional W lamp |
| Data Acquisition Rate | 100 Hz |
| Baseline Noise (UV) | ≤ ±0.2 × 10⁻⁵ AU (empty cell) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Precision | < 0.1 nm |
| RI Detector Refractive Index Range | 1.00–1.75 |
| RI Detector Noise | ≤ 2.5 nRIU |
| Sample Capacity | 2 × 48 vials (2 mL), optional 96-/384-well plates |
| Auto-sampler Cycle Time | 17 s (injection only), 60 s including needle wash |
| Injection Reproducibility (full-loop) | RSD < 0.3% |
| Column Oven Temp Stability | ±0.1 °C |
| Power Supply | AC 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 260 × 360 × 170 mm |
| Weight | 10.0 kg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 0–399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 30 °C/min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Detection Limit (FID) | ≤1×10⁻¹¹ g/s |
| Baseline Noise (FID) | ≤5×10⁻¹⁴ A |
| Drift (FID) | ≤1×10⁻¹³ A/30 min |
| Linear Dynamic Range | ≥10⁶ |
| Programmable Temperature Steps | 8-stage |
| Relative Humidity Limit | ≤85% |
| Operating Ambient Temperature | +5 °C to +35 °C |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz, 10 A |
| Power Consumption | ≤1500 W |
| Dimensions (H×W×D) | 490×730×490 mm |
| Net Weight | ~48 kg |
Show next