| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HG-330 |
| Instrument Type | Fast Liquid Chromatography (FLC) Compatible Column Oven |
| Flow Rate Range | 0.001 mL/min |
| Maximum Pressure Rating | 40 MPa |
| Sample Vial Capacity | 100 positions (1.5 mL vials) |
| Injection Volume Range | 50 µL |
| Temperature Control Range | 10 °C to 60 °C |
| Wavelength Range | 700 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | STI5000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.003–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Maximum Pressure | 5400 psi |
| Injection Mode | Manual (Reodyne 7725i injector) |
| Standard Injection Volume | 20 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–700 nm (extendable to 850 nm) |
| Data Acquisition Rate | 20 Hz |
| Brand | VERTEX |
|---|---|
| Model | STI500 |
| Instrument Type | Isocratic HPLC System |
| Flow Rate Range | 0.003–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Injection Volume Range | 0.1–100 µL |
| Number of Injection Positions | 1 |
| Wavelength Range (UV-Vis Detector) | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Column Temperature Control | Ambient Only |
| Compliance | ASTM D4294, ISO 13877, USP <621>, GLP/GMP-ready software architecture |
| Brand | Vertex |
|---|---|
| Origin | Shanghai, China |
| Model | VERTEX VI500 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | 40 MPa |
| Injection Volume Range | 1–5000 µL (1 µL increment |
| Column Oven Temperature Range | 4–85 °C |
| UV Detector Wavelength Range | 190–720 nm (D₂ lamp), up to 940 nm with optional W lamp |
| Data Acquisition Rate | 100 Hz |
| Baseline Noise (UV) | ≤ ±0.2 × 10⁻⁵ AU (empty cell) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Precision | < 0.1 nm |
| RI Detector Refractive Index Range | 1.00–1.75 |
| RI Detector Noise | ≤ 2.5 nRIU |
| Sample Capacity | 2 × 48 vials (2 mL), optional 96-/384-well plates |
| Auto-sampler Cycle Time | 17 s (injection only), 60 s including needle wash |
| Injection Reproducibility (full-loop) | RSD < 0.3% |
| Column Oven Temp Stability | ±0.1 °C |
| Power Supply | AC 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 260 × 360 × 170 mm |
| Weight | 10.0 kg |