BrandLabsphere
OriginUSA
ModelSpectralon®
MaterialPTFE-based sintered polymer
Spectral Range250–2500 nm
Reflectance Options2%, 5%, 10%, 20%, 25%, 40%, 50%, 60%, 75%, 80%, 99%
Spectral Flatness±1% (400–1500 nm), ±4% (250–2500 nm)
Lambertian Character>99.9%
Calibration TraceabilityNIST-traceable
Physical FormCircular disk (1.25″ or 2.00″ diameter)
PackagingPolyoxymethylene (POM) protective case with lid
ComplianceASTM E259, ISO 13468-2, USP <857>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabsphere
OriginUSA
ModelSpectralon
Reflectance>99% (400–1500 nm), >95% (250–2500 nm)
Lambertian CharacterExcellent
Chemical StabilityInert
Thermal StabilityHigh
UV ResistanceCertified for Space-Grade Exposure
ComplianceNASA/JPL, GSFC, TRW, CSEM Qualified
Form FactorCustom-Machinable Solid PTFE-Based Material
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabsphere
ModelSPECTRAFLECT
OriginUSA
Base MaterialBarium Sulfate (BaSO₄) with Proprietary Binder System
Spectral Range300–2400 nm
Average Diffuse Reflectance (400–700 nm)96–98%
Lambertian Character>99.5% (cosine angular response)
Thermal StabilityUp to 100 °C
Laser Damage Threshold1.7 J/cm² (at 1064 nm, 10 ns pulse)
Application MethodAir-spray or HVLP spray
Substrate CompatibilityAluminum, stainless steel, anodized metals, ceramics, and machined polymers
ComplianceRoHS-compliant, non-toxic, solvent-based formulation (proprietary low-VOC carrier)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabsphere
OriginUSA
ModelAUX
Component CategoryLight Source
Compatible Power SupplyAdjustable Labsphere Power Supply
Software CompatibilityLightMtrx®
Nominal Current RatingsAUX-35 (3.07 A), AUX-50 (4.17 A), AUX-100 (8.33 A)
Mounting1-inch flange interface
Replacement LampsOC-03150-000 (AUX-35), OC-03161-000 (AUX-100)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabsphere
OriginUSA
ModelLPM
CoatingInfragold (700 nm – 20 µm)
Max Incident Power Density2 kW/cm² @ 10.6 µm (CW)
CoolingWater-cooled (NPT 0.25", max 15 psi operating, 35 psi safety relief)
Detector PortsTwo standard SMA or flanged ports
Spectral RangeUV–Vis–NIR–MIR (compatible with Labsphere calibrated detectors)
Target PlateIntegrated energy-diffusing plate
ComplianceASTM E275, ISO/IEC 17025-aligned calibration traceability, GLP-ready documentation support