- All
- Favorite
- Popular
- Most rated
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GPS |
| Pricing | Upon Request |
| Brand | LabSphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LF Human Eye Safety Testing Solution |
| Pricing | Available Upon Request |
| Spectralon Transmittance | 25% or 50% |
| Spectralon Target Size | 30 cm × 50 cm (customizable) |
| Spectralon Spectral Flatness | ±1.5% |
| Wavelength Range | 400–1000 nm |
| DUT-to-Target Distance | 5–30 cm |
| Maximum DUT Divergence Angle | 80° (customizable up to 120°) |
| Eye Safety Aperture | 7 mm |
| Measurement Modes | Total Radiant Power, Per-Spot Radiant Power, Spatial Distribution, Angular Emission Profile, MPE (Maximum Permissible Exposure) Compliance Assessment |
| Data Output Formats | .txt, .csv |
| Software Features | Pixel-level spot detection & centroid localization, intensity calibration with NIST-traceable reference, real-time MPE calculation per IEC 62471 and ANSI Z136.1 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RTC |
| Price Range | USD $0 – $50,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Zenith Polymer® |
| Thickness Options | 100 µm, 250 µm, 500 µm, 1 mm, 2 mm |
| Spectral Range | 250–2500 nm |
| Transmittance | 4–50% (wavelength-dependent) |
| Surface Characteristics | Lambertian diffusion |
| Compliance | ASTM E308, ISO/CIE 11664-4, NIST-traceable reflectance calibration available |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CSTM-VCSEL-PW-060-LIVT |
| Pricing | Available Upon Request |
| Integrating Sphere Material | Spectralon® / Spectraflect® / Permaflect® |
| Sphere Diameter | 6 in (customizable) |
| Input Port Diameter | 1.5 in (customizable) |
| Spectrometer Wavelength Range | 800–980 nm |
| Spectral Resolution (FWHM) | 0.1–0.16 nm |
| Wavelength Accuracy | ±0.1 nm |
| Maximum Sampling Rate | 200 kHz |
| Optical Power Range (Spectralon®, 940 nm) | 1 mW – 200 W |
| High-Speed Detector Linearity | ±0.5% |
| Detector Measurement Accuracy | ±1% |
| Detector Effective Digits | 5 |
| VCSEL Temperature Control Range | 1–85 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | INFRAGOLD® |
| Laser Damage Threshold | ≥19.3 J/cm² @ 10.6 µm (CO₂, 10 ns pulse) |
| Substrate Compatibility | Aluminum, Nickel, Iron, Copper, Tungsten |
| Application Range | 250 nm – 25 µm (peak performance: 1000 nm – 12 µm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LMS-3M |
| Diameter | 3 m |
| Compliance | IESNA LM-79, LM-80, ENERGY STAR® Thermal Test Requirements |
| Internal Coating | Spectraflect® (≥98% diffuse reflectance, 400–700 nm) |
| Measurement Geometry | Configurable 4π or 2π via optional baffle & port reducer |
| Detector Compatibility | Multiple photometric and spectroradiometric sensors simultaneously |
| Mounting Flexibility | Upward, downward, or axial lamp orientation |
| Temperature Control | Integrated thermal monitoring module with inlet/outlet baffles |
| Structural Assembly | Field-installed modular design (wedge segments, base frame, fasteners) |
| Dimensions (packed) | ~3.3 × 2.3 × 1.6 m per crate |
| Required Site Conditions | Level floor, structural load capacity ≥500 kg/m² |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFC |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SPECTRA-QT |
| Pricing | Available Upon Request |
| Spectral Irradiance Range | 375–1100 nm |
| Spectral Bandwidth | 5–10 nm |
| Wavelength Accuracy | ±0.6 nm |
| Aperture Diameters | 22 mm, 23.9 mm, 26.2 mm, 29 mm |
| Max Spectral Irradiance (400 nm) | 12 μW/cm²/nm |
| Max Spectral Irradiance (600 nm) | 21 μW/cm²/nm |
| Max Spectral Irradiance (800 nm) | 5 μW/cm²/nm |
| Max Spectral Radiance (400 nm) | 32 μW/cm²·sr·nm |
| Max Spectral Radiance (600 nm) | 54 μW/cm²·sr·nm |
| Max Spectral Radiance (800 nm) | 11 μW/cm²·sr·nm |
| UV-VIS Stability (550 nm) | <1.5% over 5 s |
| VIS-NIR Stability (750 nm) | <0.05% over 5 s |
| NIST-Traceable Calibration | Yes |
| Software Development Kit (SDK) | Included |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF, RT-060-IG, RTC-060-SF, RTC-060-IG |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (RT) |
| Detector Port | 0.5-inch (top-mounted for RT, bottom-mounted for RTC) |
| Mirror Trap | Integrated specular beam trap |
| Sample Mounting | Adjustable center-stage (RTC), dual 1-inch sample holders (RT), optional jaw-type / clamp-type / slot-type fixtures |
| Compliance | Designed for ASTM E1331, ISO 9050, CIE No. 15, USP <857>, and GLP/GMP-aligned measurement workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | ILT2400-UVC |
| Detector Type | SED270C/W SiC Photodiode |
| Spectral Range | 230–280 nm |
| Peak Sensitivity | 265 nm |
| Irradiance Range | 100 nW/cm² to 1 W/cm² |
| Dose Range | 100 nJ/cm² to >1 MJ/cm² |
| Calibration | ISO/IEC 17025 Accredited, NIST-Traceable |
| Display | Integrated Touchscreen Interface |
| Connectivity | USB Mini & Micro (Data Transfer + Charging) |
| Software | Datalight III (macOS & Windows Compatible) |
| Enclosure | Rugged Carry Case with Integrated Stand |
| Detector Cable Length | 2.1 m (7 ft) |
| Optical Element | Fused Silica Diffuser |
| Filter | Built-in UVC Bandpass Filter |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS System |
| Spectral Range | 350–1700 nm (Si & InGaAs detectors) |
| Integrating Sphere Diameters | 2", 4", 6" |
| Coating Options | Spectraflect®, Spectralon®, Infragold® |
| Detector Options | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Power Range | ~1 nW to >100 W (configuration-dependent) |
| Input Port Angle | 45° off-axis |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia®Plus2-2600 |
| Integrating Sphere Diameter | 165 cm or 195 cm |
| Spectral Range | 325–1050 nm |
| Temperature Control Range | 15–80°C |
| Typical Ramp Rate (20→80°C) | 52 min |
| Detector | TE-cooled, back-illuminated CCD array |
| Exposure Time | 8 ms – 900 s |
| Compliance | IES LM-79-19, LM-82-12, LM-78-15, ISO/CIE S 025:2015 |
| Software | Integral® v5.x with automated stability assessment and CFR 21 Part 11-ready audit trail |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COLOSUS System |
| Price Range | USD $65,000 – $105,000 |
| Spectral Range | 0.3–14 µm |
| Calibration Traceability | NIST-traceable radiance/irradiance |
| Dynamic Range | >1×10¹⁰ |
| Uniformity | >98% (spatial) |
| Blackbody Temperature Range | −40 °C to +175 °C |
| Blackbody Emissivity | >0.998 |
| Temperature Stability | ±0.01 °C |
| Aperture Size | 4 in (102 mm) |
| Software Platform | IRWindows™ 4 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ILT2400 UVG |
| Pricing | Available Upon Request |
| Spectral Range | 240–310 nm |
| Irradiance Range | 10 nW/cm² to 500 µW/cm² |
| Radiant Exposure (Dose) Range | 10 nJ/cm² to >1 MJ/cm² |
| Calibration | NIST-Traceable, ISO/IEC 17025:2017 Accredited |
| Detector Type | UVGI-Optimized SED240/WBS320/W Filtered Photodiode |
| Display | 4.3″ VGA Capacitive Touchscreen |
| Current Measurement Range | 50 pA – 1 mA |
| Dynamic Range | 8 decades |
| Bias Voltage | 5 V Reverse Bias |
| Internal Storage | 4 GB |
| Operating Temperature | 0–40 °C |
| Interfaces | USB Micro (data download), USB Mini (charging & remote logging via DataLight III) |
| Dimensions | 1.6″ H × 3.0″ W × 6.0″ L |
| Weight | 0.95 kg |
| Enclosure | Rugged Portable Carry Case |
| Compliance | CE (EMC Class B, no RF emissions interference) |
| Software | DataLight III (macOS & Windows compatible) |
| Sensor Connector | 15-pin D-sub |
| Application Scope | Non-pulsed UV-C sources only — low-pressure & medium-pressure mercury lamps, UVC LEDs, excimer lamps |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PFT |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | CSTM-CM-PD |
| Price Range | USD 1,400 – 140,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia® Pro3-UV |
| Integrating Sphere Diameter | 15 cm |
| Spectral Range (Calibrated) | 200–400 nm |
| Wavelength Accuracy | ±0.4 nm |
| Integration Time | 8 ms – 900 s |
| Spectrometer | CDS-2600-UV |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | CSTM-RTC |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (sample & 9° specular-reflected beam), 0.5-inch top detector port, bottom detector port (RTC), integrated central sample mount |
| Geometry | 9°/h reflectance, variable-angle incidence capability (RTC), specular trap included |
| Internal Baffle Design | Low-profile, minimized obstruction to maximize wall visibility |
| Aperture Edge | Knife-edge for wide-angle scatter collection |
| Compliance | ASTM E1331, ISO 13468, ISO 13469, USP <857>, compatible with GLP/GMP data integrity workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectra-PT |
| Type | Integrating Sphere-Based Uniform Light Source for Photometric and Radiometric Calibration |
| Compliance | NIST-traceable calibration options available |
| Control Interface | Analog 0–10 V and digital RS-232/USB |
| Dynamic Range | >10⁶:1 (typical, dependent on detector and configuration) |
| Spectral Range | 350–1000 nm (standard halogen/tungsten-halogen lamp configuration) |
| Uniformity | ≥98% spatial uniformity over output port (per ISO 9050 and CIE S 023) |
| Stability | <0.2% RMS over 30 min (thermal + power supply stabilized) |
| Port Diameter | 4", 6", or 8" (configurable) |
| Lamp Life | ≥2000 h (rated at nominal voltage) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Spectralon® Target Board |
| Calibration Range | 250–2500 nm (NIST-traceable) |
| Reflectance Options | 2% to 99% |
| Standard Mounting Frame | Anodized Aluminum (Rough Surface Finish) |
| Dimensions Available | 2×2 in to 24×24 in |
| Thickness | 0.65 in |
| Thermal & Chemical Stability | High |
| Cleanability | Water-rinsable |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PERMAFLECT® |
| Price Range | USD $0–$7,200 (est.) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Illumia Pro3 |
| Sphere Diameter | 50 cm |
| Spectral Range (Calibrated) | 350–1000 nm |
| Wavelength Accuracy | ±0.3 nm |
| Integration Time | 40 µs – 5 s |
| Measurement Geometry | 2π |
| Coating | Spectralect® White Diffuse Reflectance Coating |
| Software | Integral™ v5.x (with Temperature, Current & Voltage Control, Real-Time LIVT Synchronization, and GLP-Compliant Data Logging) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | SF |
| Wavelength Range | 300–2400 nm |
| Reflectance | >99% (400–1100 nm, ≥0.5 mm thickness) |
| Lambertian Characteristic | Near-perfect |
| Thermal Stability | Up to 100°C |
| Laser Damage Threshold | 1.7 J/cm² @ 532 nm, Q-switched Nd:YAG |
| Composition | Barium sulfate–based aqueous formulation |
| Application Method | Air-spray only |
| Substrate Compatibility | Universal (metal, plastic, ceramic, composites) |
| Toxicity | Non-toxic |
| Solvent | Water-based |
| Re-coatability | Yes |
| Adhesion Prep | Degreasing + grit blasting |
Show next