| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | CCS |
| Operating Mode | Steady-State |
| Spectral Range | 350–2400 nm |
| Correlated Color Temperature | 5250 K |
| Beam Divergence | <3° |
| Illuminated Area Diameter at 3 m | 20 cm |
| Irradiance Uniformity | ≥98% |
| Typical Irradiance at 3 m | ~1000 W/m² (AM1.5G equivalent) |
| Control Interface | Software-Driven Digital Control System |
| Light Source Technology | Multi-Lamp Plasma-Based Architecture |
| Compliance | Designed to meet ASTM E927-23, IEC 60904-9 Ed. 3, ISO 9276-2 for spectral match and spatial uniformity requirements |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GPS |
| Pricing | Upon Request |
| Brand | LabSphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LF Human Eye Safety Testing Solution |
| Pricing | Available Upon Request |
| Spectralon Transmittance | 25% or 50% |
| Spectralon Target Size | 30 cm × 50 cm (customizable) |
| Spectralon Spectral Flatness | ±1.5% |
| Wavelength Range | 400–1000 nm |
| DUT-to-Target Distance | 5–30 cm |
| Maximum DUT Divergence Angle | 80° (customizable up to 120°) |
| Eye Safety Aperture | 7 mm |
| Measurement Modes | Total Radiant Power, Per-Spot Radiant Power, Spatial Distribution, Angular Emission Profile, MPE (Maximum Permissible Exposure) Compliance Assessment |
| Data Output Formats | .txt, .csv |
| Software Features | Pixel-level spot detection & centroid localization, intensity calibration with NIST-traceable reference, real-time MPE calculation per IEC 62471 and ANSI Z136.1 |
| Brand | Labsphere |
|---|---|
| Model | RSA-FO-150-800-S |
| Wavelength Range | 360–1000 nm |
| Configuration | Dual-beam reflectance & transmittance measurement system with fiber-optic illumination and spectrometer integration |
| Integral Sphere Type | Dual-beam reflectance & transmittance sphere (150 mm diameter, barium sulfate coating, FO port configuration) |
| Compliance | ASTM E275, ASTM E903, ISO 9050, ISO 13468, ISO 14782, CIE S 014 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RTC |
| Price Range | USD $0 – $50,000 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Zenith Polymer® |
| Thickness Options | 100 µm, 250 µm, 500 µm, 1 mm, 2 mm |
| Spectral Range | 250–2500 nm |
| Transmittance | 4–50% (wavelength-dependent) |
| Surface Characteristics | Lambertian diffusion |
| Compliance | ASTM E308, ISO/CIE 11664-4, NIST-traceable reflectance calibration available |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CSTM-VCSEL-PW-060-LIVT |
| Pricing | Available Upon Request |
| Integrating Sphere Material | Spectralon® / Spectraflect® / Permaflect® |
| Sphere Diameter | 6 in (customizable) |
| Input Port Diameter | 1.5 in (customizable) |
| Spectrometer Wavelength Range | 800–980 nm |
| Spectral Resolution (FWHM) | 0.1–0.16 nm |
| Wavelength Accuracy | ±0.1 nm |
| Maximum Sampling Rate | 200 kHz |
| Optical Power Range (Spectralon®, 940 nm) | 1 mW – 200 W |
| High-Speed Detector Linearity | ±0.5% |
| Detector Measurement Accuracy | ±1% |
| Detector Effective Digits | 5 |
| VCSEL Temperature Control Range | 1–85 °C |
| Temperature Stability | ±0.1 °C |
| Brand | Labsphere |
|---|---|
| Model | FOL-150-S |
| Light Source Type | Quartz-Tungsten-Halogen (QTH) |
| Output Power | 150 W |
| Spectral Range | 350 nm – 1000 nm (QTH core), extended usable range 400 nm – 1600 nm via fiber transmission |
| Fiber Interface | SMA 905 connector |
| Integrated Hot Mirror | Yes |
| Compatibility | Designed for Labsphere integrating spheres (e.g., RSA, UV-VIS-NIR series) |
| Cooling | Forced-air convection |
| Dimensions (H×W×D) | 140 × 220 × 320 mm |
| Weight | 4.8 kg |
| Regulatory Compliance | CE, RoHS, UL-listed power supply |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | INFRAGOLD® |
| Laser Damage Threshold | ≥19.3 J/cm² @ 10.6 µm (CO₂, 10 ns pulse) |
| Substrate Compatibility | Aluminum, Nickel, Iron, Copper, Tungsten |
| Application Range | 250 nm – 25 µm (peak performance: 1000 nm – 12 µm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS-1 |
| Detector Type | Calibrated Photodiode or Thermopile Sensor |
| Spectral Range | Customizable (e.g., 190–1100 nm or 800–1800 nm) |
| Power Range | 100 µW to 100 W (CW), up to 1 kW peak (pulsed, with appropriate attenuation) |
| Input Port Diameter | 25 mm, 50 mm, or 100 mm (configurable) |
| Coating | Spectralon® or custom diffuse reflectance coating (≥99% uniform reflectance) |
| Calibration Traceability | NIST-traceable |
| Compliance | ISO/IEC 17025 accredited calibration available |
| Software Interface | USB 2.0, compatible with Windows-based LPMS Control & Analysis Suite |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LMS-3M |
| Diameter | 3 m |
| Compliance | IESNA LM-79, LM-80, ENERGY STAR® Thermal Test Requirements |
| Internal Coating | Spectraflect® (≥98% diffuse reflectance, 400–700 nm) |
| Measurement Geometry | Configurable 4π or 2π via optional baffle & port reducer |
| Detector Compatibility | Multiple photometric and spectroradiometric sensors simultaneously |
| Mounting Flexibility | Upward, downward, or axial lamp orientation |
| Temperature Control | Integrated thermal monitoring module with inlet/outlet baffles |
| Structural Assembly | Field-installed modular design (wedge segments, base frame, fasteners) |
| Dimensions (packed) | ~3.3 × 2.3 × 1.6 m per crate |
| Required Site Conditions | Level floor, structural load capacity ≥500 kg/m² |
| Brand | Labsphere |
|---|---|
| Model | UV1800F |
| Wavelength Range | 250–450 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth (FWHM) | < 4 nm |
| Wavelength Step | 1 nm |
| Optical Geometry | d/0 (diffuse illumination / 0° viewing) with integrating sphere |
| Sphere Port Diameter | 1.27 cm |
| Sample Illuminated Area | 1.26 cm² |
| Light Source | Pulsed Xenon Lamp |
| UV Dose per Measurement | < 0.2 J/cm² |
| Transmittance Range | 0–100% |
| Absorbance Range | 0–2.2 AU |
| UPF Range | 1–200+ |
| Compliance Standards | AS/NZS 4399:2017, EN 13758-1:2007, AATCC TM183:2020, GB/T 18830:2009, JIS L 1925:2019 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFC |
| Pricing | Upon Request |
| Brand | Labsphere |
|---|---|
| Model | RSA-REF-50-DB |
| Illumination Geometry | 8°/h (8° illumination, hemispherical detection) |
| Sphere Diameter | 50 mm |
| Light Source | Integrated Tungsten-Halogen or Optional LED Module |
| Fiber Optic Interface | SMA 905 |
| Compliance | ISO/CIE Compliant Optical Design |
| Origin | Shanghai, China |
| Distribution Status | Authorized Distributor |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SPECTRA-QT |
| Pricing | Available Upon Request |
| Spectral Irradiance Range | 375–1100 nm |
| Spectral Bandwidth | 5–10 nm |
| Wavelength Accuracy | ±0.6 nm |
| Aperture Diameters | 22 mm, 23.9 mm, 26.2 mm, 29 mm |
| Max Spectral Irradiance (400 nm) | 12 μW/cm²/nm |
| Max Spectral Irradiance (600 nm) | 21 μW/cm²/nm |
| Max Spectral Irradiance (800 nm) | 5 μW/cm²/nm |
| Max Spectral Radiance (400 nm) | 32 μW/cm²·sr·nm |
| Max Spectral Radiance (600 nm) | 54 μW/cm²·sr·nm |
| Max Spectral Radiance (800 nm) | 11 μW/cm²·sr·nm |
| UV-VIS Stability (550 nm) | <1.5% over 5 s |
| VIS-NIR Stability (750 nm) | <0.05% over 5 s |
| NIST-Traceable Calibration | Yes |
| Software Development Kit (SDK) | Included |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Blue Sun |
| Light Source Type | Xenon-based broadband solar simulator |
| Illumination Mode | External illumination |
| Spectral Range | 400–2500 nm |
| Output Stability | <0.5% RMS over 8 hours |
| Spectral Smoothness | <1.5% spectral gradient in visible range |
| Calibration Interval | ≥12 months (under recommended operating conditions) |
| Lifetime | ≥2000 hours (xenon arc lamp, typical) |
| Brand | Labsphere |
|---|---|
| Model | ACR |
| Origin | Shanghai, China |
| Light Source Type | Tunable Integrating Sphere Source (Xenon/Mercury-Hybrid Capable) |
| Illumination Geometry | Internal Illumination |
| Color Temperature Range | 2000 K – 10000 K (CCT-adjustable) |
| Spectral Output | Programmable to CIE Standard Illuminants (A, D50, D65, D75, etc.) |
| Luminance Range | 0.01 – 100,000 cd/m² (adjustable) |
| Viewing Angles | 0°, 15°, 30°, 45° (symmetrical left/right ports |
| Detector Platform | Motorized Linear Rail with Sub-millimeter Positioning Accuracy |
| Compliance Standards | ICDM, VESA DisplayHDR™, NIST IR 6738, ISO 9241-307, CIE S 023/E:2022 |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF, RT-060-IG, RTC-060-SF, RTC-060-IG |
| Coating Options | Spectraflect® (300–2400 nm), Infragold® (0.7–20 µm) |
| Port Configuration | Five 1-inch ports (RT) |
| Detector Port | 0.5-inch (top-mounted for RT, bottom-mounted for RTC) |
| Mirror Trap | Integrated specular beam trap |
| Sample Mounting | Adjustable center-stage (RTC), dual 1-inch sample holders (RT), optional jaw-type / clamp-type / slot-type fixtures |
| Compliance | Designed for ASTM E1331, ISO 9050, CIE No. 15, USP <857>, and GLP/GMP-aligned measurement workflows |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | ILT2400-UVC |
| Detector Type | SED270C/W SiC Photodiode |
| Spectral Range | 230–280 nm |
| Peak Sensitivity | 265 nm |
| Irradiance Range | 100 nW/cm² to 1 W/cm² |
| Dose Range | 100 nJ/cm² to >1 MJ/cm² |
| Calibration | ISO/IEC 17025 Accredited, NIST-Traceable |
| Display | Integrated Touchscreen Interface |
| Connectivity | USB Mini & Micro (Data Transfer + Charging) |
| Software | Datalight III (macOS & Windows Compatible) |
| Enclosure | Rugged Carry Case with Integrated Stand |
| Detector Cable Length | 2.1 m (7 ft) |
| Optical Element | Fused Silica Diffuser |
| Filter | Built-in UVC Bandpass Filter |
| Brand | LabSphere |
|---|---|
| Model | LFUSS |
| Coating | Spectraflect® or Spectralon® |
| Internal Diameter Options | 15 cm – 200 cm |
| Spectral Range | 350–2500 nm |
| Calibrated Radiance Range | 0–40,000 nit |
| Uniformity | ≥98% |
| Stability | ±0.1% |
| Light Source Type | Tungsten-halogen (150 W external + multiple internal options: 35/75/100/150 W) |
| Illumination Method | Internal illumination |
| Motorized Attenuator | ≥35,000 steps |
| Calibration Traceability | NIST and NIM (China National Institute of Metrology) |
| Operating Temperature | 20–40 °C |
| Detector Type | Silicon photodiode |
| Validated Spectral Calibration Range | 360–1100 nm |
| Color Temperature | 2856 ± 50 K |
| Aperture Configurations | Dual detector ports + variable source access ports |
| Software Compatibility | LabSphere Uniform Source Measurement Software (customizable) |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LCA-XXXXX-XXX |
| Price | Upon Request |
| Wavelength Range | 300–1100 nm |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LFPMS |
| Pricing | Available Upon Request |
| Power Range | 100 nW – 100 W |
| Wavelength Range | 350 nm – 1800 nm |
| Calibration Traceability | National Institute of Metrology (NIM), China |
| Integrating Sphere Diameters | 2″ (5 cm), 4″ (10 cm), 6″ (15 cm), 8″ (20 cm) |
| Input Aperture | 0.5″ (12.7 mm) for LFPMS-020 |
| Coating Reflectance | ≥98% (Spectralon®-type diffuse reflectance coating) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPMS System |
| Spectral Range | 350–1700 nm (Si & InGaAs detectors) |
| Integrating Sphere Diameters | 2", 4", 6" |
| Coating Options | Spectraflect®, Spectralon®, Infragold® |
| Detector Options | Silicon (Si), Indium Gallium Arsenide (InGaAs) |
| Power Range | ~1 nW to >100 W (configuration-dependent) |
| Input Port Angle | 45° off-axis |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | illumia®Plus2-2600 |
| Integrating Sphere Diameter | 165 cm or 195 cm |
| Spectral Range | 325–1050 nm |
| Temperature Control Range | 15–80°C |
| Typical Ramp Rate (20→80°C) | 52 min |
| Detector | TE-cooled, back-illuminated CCD array |
| Exposure Time | 8 ms – 900 s |
| Compliance | IES LM-79-19, LM-82-12, LM-78-15, ISO/CIE S 025:2015 |
| Software | Integral® v5.x with automated stability assessment and CFR 21 Part 11-ready audit trail |
Show next