Empowering Scientific Discovery

Shanghai Mass Spectrometry Peak Technology Co., Ltd. (SunnyHengping Instruments)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPOTOP
OriginShanghai, China
ModelDO6401
Measurement Range0.00–40.00 mg/L and 0.0–400.0% saturation
Resolution0.01 mg/L, 0.1%
Accuracy±1.5% F.S.
Temperature Range−5.0 to 120.0 °C (23.0 to 248.0 °F)
Temp. Resolution0.1 °C / 0.1 °F
Temp. Accuracy±0.3 °C / ±0.5 °F
Salinity Compensation0.0–45.0 ppt
Pressure Compensation450–800 mmHg or 0.500–1.100 bar
Pipe Pressure Compensation0.00–1.00 kg
Depth Compensation0.0–10.0 m
IP RatingIP67
Data Storage100 sets
Auto Power-OffConfigurable (default: 10 min inactivity)
Display3.2-inch multi-line LCD with anti-scratch coating
Power2 × 1.5 V AA batteries
Electrode DiagnosticsOffset & Slope display, self-diagnostic status
ConnectivityOptional USB interface
SoftwareOptional data acquisition software with PC compatibility
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOP TOP
ModelDO35
TypePortable Electrochemical Dissolved Oxygen Meter
Measurement PrincipleClark-type Polarographic Membrane Electrode
DisplayMulti-line LED with backlight (22 × 32 mm)
Protection RatingIP67
Power Supply1 × AA alkaline battery (1.5 V)
Auto-off6 min inactivity with data retention
Data Storage10 measurement records
Operating Temperature0–60.0 °C (32–140.0 °F)
DO Range0.00–20.00 mg/L and 0.0–200.0 % saturation
Resolution0.01 mg/L, 0.1 %, 0.1 °C, 1 °F
Accuracy±1.5 % of full scale
Temperature CompensationAutomatic or manual
Atmospheric Pressure Compensation600–1100 mbar
Salinity Compensation0.0–140.0 ppt
Calibration1-point or 2-point (air-saturated water or zero-oxygen solution)
Hold FunctionYes
Low-Battery IndicatorYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOP TOP
OriginShanghai, China
ModelDO6400
Measurement Range0.00–40.00 mg/L, 0.0–400.0%
Resolution0.01 mg/L, 0.1%
Accuracy±1.5% F.S.
Temperature Range−5.0–120.0 °C (23.0–248.0 °F)
Temp. Resolution0.1 °C/°F
Temp. Accuracy±0.3 °C, ±0.5 °F
Salinity Compensation0.0–45.0 ppt
Pressure Compensation450–800 mmHg (0.500–1.100 bar)
Pipeline Pressure Compensation0.00–1.00 kg
Depth Compensation0.0–10.0 m
Data Storage100 sets
Auto-offConfigurable (default: 10 min idle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOP TOP
ModelCON6301
Conductivity Range0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm
TDS Range0–500 ppt
Salinity Range0–325 ppt
Conductivity Resolution0.001–1 µS/cm, 0.01 mS/cm
Conductivity Accuracy±1% of Full Scale
Resistivity Range0.00–18.30 MΩ·cm
Resistivity Resolution0.01 MΩ·cm
Temperature Range−5.0–120.0 °C (23.0–248.0 °F)
Temperature Accuracy±0.3 °C, ±0.5 °F
Temperature Resolution0.1 °C / 0.1 °F
Temp. CompensationAuto/Manual
Reference Temp.15.0–30.0 °C (factory set at 25.0 °C)
Temp. Coefficient0.00–9.99% (factory default 2.00%)
TDS Factor0.40–1.00 (factory default 0.50)
Salinity Factor0.65
Cell Constant Options0.01, 0.1, 1.0, 10.0 cm⁻¹
IP RatingIP67
Data Storage100 measurement records
Power2 × 1.5 V AA batteries
Auto-OffConfigurable (default: 10 min idle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOP TOP
ModelION6500
TypeBenchtop Ion-Selective Electrode (ISE) Meter
Measurement PrinciplePotentiometric Ion-Selective Electrode Detection
pH Range−2.000 to 20.000
mV Range−2000.0 to +2000.0 mV
Ion Concentration Range0.000–9999 mg/L
Temperature Range−10.0 to 120.0 °C (14.0–248.0 °F)
Resolution0.001 pH / 0.1 mV / 0.001 mg/L / 0.1 °C / 0.1 °F
Accuracy±0.001 pH / ±0.2 mV / ±0.005 mg/L / ±0.3 °C / ±0.5 °F
CalibrationUp to 5-point pH, up to 7-point ISE
Data Storage1000 measurement records
InterfaceUSB-B port for PC connectivity
PowerInternal rechargeable 3.7 V Li-ion battery (battery not included)
Display5-inch LED, 120° viewing angle
ComplianceDesigned per IEC 61010-1 for laboratory electrical safety
SoftwareIncluded Windows-compatible data acquisition software with audit trail logging capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPTOP
OriginShanghai, China
ModelCON35
Measurement Range0–200.0 µS/cm (ppm), 0–50.0 mS/cm (ppt)
Temperature Range0–60.0 °C / 32–140.0 °F
Temperature CompensationAutomatic or Manual
Resolution0.1 / 1 µS/cm (ppm), 0.1 / 1 mS/cm (ppt), 0.1 °C, 1 °F
Accuracy±1% F.S.
Temperature Coefficient Adjustment0.00–10.00%
TDS Conversion Factor0.40–1.00
Salinity Factor0.65
Electrode MaterialPPS-encapsulated graphite conductivity sensor
CalibrationSingle-point auto-ranging calibration
Data Storage10 measurement records
Ingress ProtectionIP67
DisplayMulti-line LED, 22 × 32 mm active area with energy-efficient backlight
Power Supply1 × AA alkaline battery (1.5 V)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOP TOP
ModelCON6300
Conductivity Range0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm
TDS Range0–500 ppt
Salinity Range0–325 ppt
Conductivity Resolution0.001–1 µS/cm, 0.01 mS/cm
Conductivity Accuracy±1% of Full Scale
Resistivity Range0.00–18.30 MΩ·cm
Resistivity Resolution0.01 MΩ·cm
Temperature Range−5.0–120.0 °C (23.0–248.0 °F)
Temperature Accuracy±0.3 °C, ±0.5 °F
Temperature Resolution0.1 °C / 0.1 °F
Temp. CompensationAuto/Manual
Reference Temp.15.0–30.0 °C (default 25.0 °C)
Temp. Coefficient0.00–9.99% (default 2.00%)
TDS Factor0.40–1.00 (default 0.50)
Salinity Factor0.65
Cell Constant Options0.01, 0.1, 1.0, 10.0 cm⁻¹
Data Storage100 memory slots
PowerRechargeable 3.7 V Li-ion battery (base-integrated, battery not included)
InterfaceUSB port for PC connectivity
Display5-inch multi-line LCD with high-brightness backlight
FeaturesAuto-hold, electrode diagnostics, temperature offset adjustment, key beep, programmable auto-off (default 10 min idle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOP TOP
ModelION6501
TypePortable Electrochemical Ion Analyzer
Measurement PrinciplesPotentiometric Ion-Selective Electrode (ISE) Method
pH Range−2.000 to 20.000 pH
mV Range−2000.0 to +2000.0 mV
Ion Concentration Range0.000–9999 mg/L (ion-specific, dependent on calibrated ISE)
Temperature Range−10.0 to 120.0 °C (14.0 to 248.0 °F)
Temperature CompensationAutomatic or Manual
Resolution0.001 pH / 0.1 mV / 0.001 mg/L / 0.1 °C / 0.1 °F
Accuracy±0.001 pH / ±0.2 mV / ±0.005 mg/L / ±0.3 °C / ±0.5 °F
CalibrationUp to 5-point pH calibration
Calibration RemindersConfigurable interval (0–60 days)
Data Storage1000 measurement records with timestamp, user ID, instrument ID, and calibration metadata
Power Supply2 × 1.5 V AA alkaline batteries
Display3.2-inch multi-line LCD with anti-scratch coating and adjustable high-brightness backlight
Communication InterfaceUSB 2.0 compliant port
SoftwareWindows-compatible data acquisition software with audit trail logging capability
Auto-Power-OffProgrammable (default: 10 min idle timeout)
User Authentication4-digit password protection
Instrument & User ID Customization4-digit serial number + 2-digit user code
Date/Time Format OptionsYY/MM/DD, MM/DD/YY, DD/MM/YY
Reading Lock FunctionEnable/disable
Temperature Offset Adjustment±5.0 °C (±9.0 °F)
Real-time Calibration DiagnosticsSlope (%), offset (mV), and calibrated point count displayed during/after calibration
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0