- All
- Favorite
- Popular
- Most rated
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | GC1120 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +7 °C to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 250 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.3 MPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | LC1620A |
| Instrument Category | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 45 MPa |
| Autosampler Capacity | 0–120 positions |
| Injection Volume Range | 0–120 µL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | IC1800 |
| Instrument Type | Laboratory Benchtop System |
| Pump Pressure Range | 0–25 MPa |
| Flow Rate Range | 0.000–9.999 mL/min |
| Eluent Flow Rate Range | 0.000–9.999 mL/min |
| Maximum Operating Pressure | 25 MPa |
| Column Oven Temperature Range | Ambient to 60 °C |
| Temperature Reproducibility | ±0.1 °C within ambient +2 °C to 100 °C |
| Eluent Concentration Range | 0–100 mmol/L (expressed as OH⁻) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-Made) |
| Model | GC1290 |
| Instrument Category | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5°C to 420°C |
| Ramp Rate | 0–80°C/min |
| Cool-Down Time | <2.5 min (from 350°C to 100°C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Injector Maximum Operating Temperature | 420°C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–250 µL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC1620APlus |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤ ±0.3% RSD |
| Wavelength Range (UV-Vis Detector) | 190–680 nm |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | LC1620A |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 45 MPa |
| Autosampler Capacity | Up to 120 positions |
| Injection Volume Range | 0.1–120 μL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV Detector Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Flow Accuracy | ≤±0.5% (at 1 mL/min, water) |
| Flow Precision (RSD) | ≤0.08% (at 1 mL/min, water) |
| UV Wavelength Accuracy | ±1 nm |
| UV Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤±0.8×10⁻⁵ AU |
| Baseline Drift | ≤1×10⁻⁴ AU/h |
| LOD (UV) | 0.4×10⁻⁸ g/mL (naphthalene in methanol) |
| Linear Dynamic Range (UV) | ≥10⁴ |
| RI Detector Refractive Index Range | 1.00–1.75 |
| ELSD Evaporator Temp Range | Ambient to 130°C |
| ELSD Detection Limit | <1 ng (glucose, direct injection) |
| Autosampler Precision (RSD) | <0.5% |
| Carryover | <0.01% |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GC1120 NMHC-Dedicated Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | Ambient +7 °C to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cooling Rate | 250 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.3 MPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | IC1820 |
| Instrument Type | Laboratory Benchtop |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 1.5 mL/min |
| Max Operating Pressure | 15 MPa |
| Column Oven Temperature Range | 25–60 °C |
| Temperature Stability | ±0.5 °C |
| Eluent Concentration Range | 0–100 mM (OH⁻ or CO₃²⁻/HCO₃⁻) |
Show next