Add to compare
BrandSunny Hengping Instrument
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-made)
ModelGC1120
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature RangeAmbient +7 °C to 400 °C
Oven Ramp Rate0–40 °C/min
Oven Cool-down Rate250 °C to 50 °C in ≤7 min
Carrier Gas Flow Range & Control0–200 mL/min
Carrier Gas Pressure Range & Control0–0.3 MPa
Injector Maximum Operating Temperature420 °C
Injector Pressure Setting Range0–0.3 MPa
Injector Total Flow Setting Range0–200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunny Hengping Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional OriginDomestic (China)
ModelLC1620A
Instrument CategoryConventional HPLC System
Flow Rate Range0.001–9.999 mL/min
Maximum Pressure45 MPa
Autosampler Capacity0–120 positions
Injection Volume Range0–120 µL
Column Oven Temperature RangeAmbient +5°C to 100°C
UV-Vis Wavelength Range190–700 nm
Data Acquisition Frequency1 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunny Hengping Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelIC1800
Instrument TypeLaboratory Benchtop System
Pump Pressure Range0–25 MPa
Flow Rate Range0.000–9.999 mL/min
Eluent Flow Rate Range0.000–9.999 mL/min
Maximum Operating Pressure25 MPa
Column Oven Temperature RangeAmbient to 60 °C
Temperature Reproducibility±0.1 °C within ambient +2 °C to 100 °C
Eluent Concentration Range0–100 mmol/L (expressed as OH⁻)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunny Hengping Instrument
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-Made)
ModelGC1290
Instrument CategoryLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient + 5°C to 420°C
Ramp Rate0–80°C/min
Cool-Down Time<2.5 min (from 350°C to 100°C)
Carrier Gas Flow Range & Control0–200 mL/min
Carrier Gas Pressure Range & Control0–100 psi
Injector Maximum Operating Temperature420°C
Injector Pressure Setpoint Range0–100 psi
Injector Total Flow Setpoint Range0–250 µL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunny Hengping Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelLC1620APlus
Price RangeUSD 7,000–14,000 (FOB Shanghai)
Instrument TypeConventional HPLC System
Application ScopeGeneral-Purpose Analytical HPLC
Flow Rate Range0.000–10.000 mL/min
Maximum Operating Pressure42 MPa
Flow Accuracy≤ ±0.3% RSD
Wavelength Range (UV-Vis Detector)190–680 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPOTOP
OriginShanghai, China
ModelLC1620A
Instrument TypeConventional High-Performance Liquid Chromatograph (HPLC)
Flow Rate Range0.001–9.999 mL/min
Maximum Operating Pressure45 MPa
Autosampler CapacityUp to 120 positions
Injection Volume Range0.1–120 μL
Column Oven Temperature RangeAmbient +5°C to 100°C
UV Detector Wavelength Range190–700 nm
Data Acquisition Frequency1 Hz
Flow Accuracy≤±0.5% (at 1 mL/min, water)
Flow Precision (RSD)≤0.08% (at 1 mL/min, water)
UV Wavelength Accuracy±1 nm
UV Wavelength Repeatability0.1 nm
Baseline Noise≤±0.8×10⁻⁵ AU
Baseline Drift≤1×10⁻⁴ AU/h
LOD (UV)0.4×10⁻⁸ g/mL (naphthalene in methanol)
Linear Dynamic Range (UV)≥10⁴
RI Detector Refractive Index Range1.00–1.75
ELSD Evaporator Temp RangeAmbient to 130°C
ELSD Detection Limit<1 ng (glucose, direct injection)
Autosampler Precision (RSD)<0.5%
Carryover<0.01%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunny Hengping Instrument
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
ModelGC1120 NMHC-Dedicated Gas Chromatograph
Instrument TypeLaboratory Gas Chromatograph
Application FieldEnvironmental Monitoring
Oven Temperature RangeAmbient +7 °C to 400 °C
Oven Ramp Rate0–40 °C/min
Oven Cooling Rate250 °C to 50 °C in ≤7 min
Carrier Gas Flow Range & Control0–200 mL/min
Carrier Gas Pressure Range & Control0–0.3 MPa
Injector Maximum Operating Temperature420 °C
Injector Pressure Setting Range0–0.3 MPa
Injector Total Flow Setting Range0–200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunny Hengping Instrument
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelIC1820
Instrument TypeLaboratory Benchtop
Maximum Pump Pressure35 MPa
Flow Rate Range0–9.999 mL/min
Eluent Flow Rate1.5 mL/min
Max Operating Pressure15 MPa
Column Oven Temperature Range25–60 °C
Temperature Stability±0.5 °C
Eluent Concentration Range0–100 mM (OH⁻ or CO₃²⁻/HCO₃⁻)