- All
- Favorite
- Popular
- Most rated
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | GC1120 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +7 °C to 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 250 °C to 50 °C in ≤7 min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.3 MPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.3 MPa |
| Injector Total Flow Setting Range | 0–200 mL/min |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | LC1620A |
| Instrument Category | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 45 MPa |
| Autosampler Capacity | 0–120 positions |
| Injection Volume Range | 0–120 µL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | DO6401 |
| Measurement Range | 0.00–40.00 mg/L and 0.0–400.0% saturation |
| Resolution | 0.01 mg/L, 0.1% |
| Accuracy | ±1.5% F.S. |
| Temperature Range | −5.0 to 120.0 °C (23.0 to 248.0 °F) |
| Temp. Resolution | 0.1 °C / 0.1 °F |
| Temp. Accuracy | ±0.3 °C / ±0.5 °F |
| Salinity Compensation | 0.0–45.0 ppt |
| Pressure Compensation | 450–800 mmHg or 0.500–1.100 bar |
| Pipe Pressure Compensation | 0.00–1.00 kg |
| Depth Compensation | 0.0–10.0 m |
| IP Rating | IP67 |
| Data Storage | 100 sets |
| Auto Power-Off | Configurable (default: 10 min inactivity) |
| Display | 3.2-inch multi-line LCD with anti-scratch coating |
| Power | 2 × 1.5 V AA batteries |
| Electrode Diagnostics | Offset & Slope display, self-diagnostic status |
| Connectivity | Optional USB interface |
| Software | Optional data acquisition software with PC compatibility |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | IC1800 |
| Instrument Type | Laboratory Benchtop System |
| Pump Pressure Range | 0–25 MPa |
| Flow Rate Range | 0.000–9.999 mL/min |
| Eluent Flow Rate Range | 0.000–9.999 mL/min |
| Maximum Operating Pressure | 25 MPa |
| Column Oven Temperature Range | Ambient to 60 °C |
| Temperature Reproducibility | ±0.1 °C within ambient +2 °C to 100 °C |
| Eluent Concentration Range | 0–100 mmol/L (expressed as OH⁻) |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1–1000 amu |
| Mass Resolution (FWHM) | ≥1200 (at m/z 502) |
| Sensitivity | ≥200:1 (Signal-to-Noise Ratio, S/N, for 1 pg OFN in Full Scan Mode) |
| Scan Speed | ≥10,000 u/s |
| Oven Ramp Rate | ≥80 °C/min |
| Pressure Control Accuracy | ±0.01 psi (EPC-controlled) |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | ESH Series (ESH122 / ESH123 / ESH124) |
| Heating Source | 600 W Quartz Halogen Lamp |
| Weighing Range | 120 g |
| Readability | 5 mg / 1 mg / 0.1 mg |
| Moisture Readability | 0.01% / 0.01% / 0.001% |
| Repeatability | ±0.5% / ±0.25% / ±0.1% (at 2 g) |
| Display | 4.3″ TFT Touchscreen |
| Temperature Range | 40–180 °C |
| Heating Modes | Standard / Progressive / Step |
| Measurement Modes | Auto / Manual / Timer / Loss-on-Drying |
| Data Storage | 36 test records |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Max Power Consumption | 800 W |
| Operating Ambient | 5–40 °C |
| Sample Pan Diameter | Φ100 mm |
| Dimensions (W×D×H) | 380 × 200 × 210 mm |
| Net Weight | 5.8 kg |
| Gross Weight | 7.8 kg |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | pH6220 |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH/mV/Temperature) |
| pH Range | -2.00 to 16.00 pH |
| mV Range | -2000 to +2000 mV |
| Temperature Range | -5.0 to 120.0 °C |
| Temperature Compensation | Automatic or Manual |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| pH Accuracy | ±0.01 pH |
| mV Accuracy | ±0.2 mV |
| Temperature Accuracy | ±0.3 °C / ±0.5 °F |
| Calibration Points | Up to 5-point NIST-traceable calibration (China-specific NIST-type buffers) |
| Data Storage | 100 measurement records |
| Auto-Power-Off | Configurable (default: 10 min inactivity) |
| Display | 5-inch LED, 120° viewing angle |
| Power | USB-powered base with integrated rechargeable 3.7 V Li-ion battery compartment (battery not included) |
| Interface | USB communication port |
| Software | Included data acquisition software (CD-based) |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Domestic |
| Model | 722 |
| Price Range | USD 0–750 |
| Optical Design | Single-Beam |
| Detector | Silicon Photocell |
| Wavelength Range | 325–1000 nm |
| Wavelength Scanning | Motorized Auto-Positioning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1.0 nm (330–1000 nm) |
| Stray Light | ≤0.5% T at 360 nm |
| Display | Backlit LCD |
| Zero Adjustment | Automatic T=0% Calibration |
| Concentration Mode | Direct C-mode with User-Defined Factor Input |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 470 × 350 × 200 mm |
| Weight | 8 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SHP8400PMS-LD |
| Pricing | Available Upon Request |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | 7230G / 723PC |
| Optical Design | Single-Beam |
| Detector Type | Photocell |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Spectral Bandwidth | 4 nm (7230G) / 2 nm (723PC) |
| Display | 4.3-inch Color Touchscreen (480 × 272 resolution) |
| Data Interface | USB |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz, 75 W |
| Net Weight | 10.0 kg |
| Dimensions (W × D × H) | 470 × 380 × 225 mm |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI-500 Series |
| Detector Type | Refractive Index Detector (RID) |
| Compatible Systems | HPLC |
| Flow Cell Volume | 2.5–8 µL |
| Linear Range | 600–6000 µRIU |
| Noise | 2.5–5 nRIU (H₂O, 1.5 s response) |
| Drift | 0.2–2 µRIU/h |
| Response Time | 0.1–6 s (adjustable) |
| Temperature Control | 30–55 °C (dual-zone) |
| Max Backpressure | 50 kPa |
| Interface | LAN |
| Power | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions | 260 W × 420 D × 165 H mm |
| Weight | 12.5 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | UV2800 / UV2800S |
| Optical System | Dual-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm (UV2800) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Photometric Accuracy | ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A), ±0.3 %T (0–100 %T) |
| Photometric Repeatability | ±0.001 A (0–0.5 A), ±0.002 A (0.5–1 A), ±0.15 %T (0–100 %T) |
| Stray Light | ≤0.03 %T at 220 nm & 360 nm |
| Baseline Flatness | ±0.001 A (200–1000 nm) |
| Scan Speed | 10–3000 nm/min (adjustable) |
| Display | 320 × 240 pixel LCD (6-inch) |
| Interface | USB 2.0 |
| Power Supply | 220 V ±10 %, 50 Hz or 110 V ±10 %, 60 Hz |
| Dimensions (W × D × H) | 545 × 450 × 235 mm |
| Net Weight | 17.0 kg |
| Gross Weight | 26.0 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-Made) |
| Model | GC1290 |
| Instrument Category | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5°C to 420°C |
| Ramp Rate | 0–80°C/min |
| Cool-Down Time | <2.5 min (from 350°C to 100°C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Injector Maximum Operating Temperature | 420°C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–250 µL/min |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | FCL35 |
| Detection Parameter | Free Chlorine (Single-Parameter) |
| Form Factor | Pen-Type Portable Analyzer |
| Measurement Range | 0.05–10.00 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±1% F.S. |
| Temperature Range | 0.0–60.0 °C |
| Calibration | Two-Point (0 ppm + User-Selectable Standard) |
| Display | 22 × 32 mm Multi-Line LCD with Energy-Saving Backlight |
| Data Storage | 10 Sets |
| IP Rating | IP67 |
| Power Supply | 1 × AA Alkaline Battery (1.5 V) |
| Auto-Power-Off | After 6 min of inactivity with data retention |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | V2200 Visible Spectrophotometer |
| Optical Design | Single-beam |
| Detector Type | Silicon photodiode |
| Wavelength Range | 325–1100 nm (0.1 nm step increment) |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | Auto-wavelength positioning |
| Display | 4.3-inch color TFT touchscreen (480 × 272 pixels) |
| Data Interface | USB |
| Light Source | Imported 20 W / 12 V halogen lamp |
| Power Supply | 220 V ±10%, 50 Hz / 110 V ±10%, 60 Hz |
| Net Weight | 10.0 kg |
| Dimensions (W × D × H) | 470 × 380 × 225 mm |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC1620APlus |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤ ±0.3% RSD |
| Wavelength Range (UV-Vis Detector) | 190–680 nm |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | SHP8400PMS-I |
| Price Range | USD 140,000 – 280,000 |
| Certifications | Ex d IIB T4 Gb / IP66 |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | 1–100 amu (standard), up to 300 amu (optional) |
| Resolution | Unit mass resolution (M/ΔM ≥ 100 at 10% valley) |
| Detection Limit | <1 ppm (for N₂, O₂, CH₄, CO, CO₂, H₂, Ar, etc.) |
| Sampling Channels | Up to 16 independent gas inlets with sequential auto-switching |
| Vacuum System | Dual-stage: Turbo-molecular pump (≥ 300 L/s) + Dry scroll backing pump |
| Operating Temperature | −10 °C to +50 °C ambient |
| Response Time | <3 s per component (typical), <30 s for full 16-channel cycle |
| Data Output | Modbus TCP, OPC UA, 4–20 mA analog outputs (configurable) |
| Compliance | IEC 60079-0/-1/-11, GB 3836.1/2/4, ISO/IEC 17025 (when operated per validated SOP) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ESH31 |
| Price | USD 780 (FOB Shanghai) |
| Heating Method | Quartz Halogen Lamp |
| Weighing Range | 110 g |
| Readability | 10 mg |
| Display | High-Resolution LCD (Backlight Optional) |
| Sensor Type | Strain-Gauge Load Cell |
| Sample Pan Diameter | Φ90 mm |
| Net Weight | 5.8 kg |
| Dimensions (L×W×H) | 200 × 180 × 380 mm |
| Operating Temperature | 5–40 °C |
| Temperature Range | 40–199 °C (1 °C increments) |
| Moisture Range | 0.00–100.00 % |
| Moisture Readability | 0.01 % |
| Drying Range | 100.00–0.00 % |
| Drying Readability | 0.01 % |
| Timer Setting | 3–99 min |
| Data Storage | 15 test history entries |
| Calibration Standard | Class F2 Stainless Steel Weights |
| Heating Power | 450 W |
| Lamp Lifetime | ≥5000 h |
| Cooling System | Low-Noise Fan (<20 dB) + Multi-Channel Airflow |
| Interface | RS232 Serial Port |
| Housing Material | Die-Cast Aluminum + High-Temp Polymer (250 °C continuous rating) |
| Chamber | Dual-Layer 304 Stainless Steel, Mirror-Finished Interior |
| Viewing Window | Frosted Tempered Glass |
| Sample Height Clearance | 22 mm |
| Leveling | Precision Bubble Level + Adjustable Feet |
| Standard Accessories | 50 × Aluminum Sample Pans |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-Made) |
| Model | UV2900 |
| Price Range | USD 7,000–10,000 (FOB Shanghai) |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm (extendable to 185 nm) |
| Wavelength Drive | Motorized Auto-Scanning |
| Spectral Bandwidth | 0.1–5.0 nm continuously variable |
| Default Discrete Bandwidth Settings | 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 nm |
| Data Output | Digital via USB 2.0 |
| Power Supply | 220 V ±10%, 50 Hz, 200 W |
| Net Weight | 30.0 kg |
| Dimensions (L×W×H) | 620 × 510 × 245 mm |
| Packaging Dimensions (L×W×H) | 745 × 635 × 400 mm |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | SHP8400PMS-Li |
| Pricing | Upon Request |
| Brand | SOP TOP |
|---|---|
| Model | DO35 |
| Type | Portable Electrochemical Dissolved Oxygen Meter |
| Measurement Principle | Clark-type Polarographic Membrane Electrode |
| Display | Multi-line LED with backlight (22 × 32 mm) |
| Protection Rating | IP67 |
| Power Supply | 1 × AA alkaline battery (1.5 V) |
| Auto-off | 6 min inactivity with data retention |
| Data Storage | 10 measurement records |
| Operating Temperature | 0–60.0 °C (32–140.0 °F) |
| DO Range | 0.00–20.00 mg/L and 0.0–200.0 % saturation |
| Resolution | 0.01 mg/L, 0.1 %, 0.1 °C, 1 °F |
| Accuracy | ±1.5 % of full scale |
| Temperature Compensation | Automatic or manual |
| Atmospheric Pressure Compensation | 600–1100 mbar |
| Salinity Compensation | 0.0–140.0 ppt |
| Calibration | 1-point or 2-point (air-saturated water or zero-oxygen solution) |
| Hold Function | Yes |
| Low-Battery Indicator | Yes |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | SHP8400PMS |
| Operating Principle | Electron Ionization (EI) coupled with Quadrupole Mass Analysis |
| Response Time | 16 ms per amu |
| Mass Range | 1–100 amu (standard configuration) |
| Mass Stability | < ±0.1 amu over 72 h |
| Sampling Channels | 16 independent channels with temperature-controlled capillary lines |
| Detection System | Faraday Cup Detector |
| Ion Source | Dual-filament EI source with enhanced water/oxygen tolerance |
| Flow Control | Integrated temperature-compensated electronic mass flow controller (MFC) |
| Data Output Format | OPC UA, Modbus TCP, ASCII CSV |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible logging |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | LC1620A |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 45 MPa |
| Autosampler Capacity | Up to 120 positions |
| Injection Volume Range | 0.1–120 μL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV Detector Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Flow Accuracy | ≤±0.5% (at 1 mL/min, water) |
| Flow Precision (RSD) | ≤0.08% (at 1 mL/min, water) |
| UV Wavelength Accuracy | ±1 nm |
| UV Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤±0.8×10⁻⁵ AU |
| Baseline Drift | ≤1×10⁻⁴ AU/h |
| LOD (UV) | 0.4×10⁻⁸ g/mL (naphthalene in methanol) |
| Linear Dynamic Range (UV) | ≥10⁴ |
| RI Detector Refractive Index Range | 1.00–1.75 |
| ELSD Evaporator Temp Range | Ambient to 130°C |
| ELSD Detection Limit | <1 ng (glucose, direct injection) |
| Autosampler Precision (RSD) | <0.5% |
| Carryover | <0.01% |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | UV2400 |
| Price Range | USD 1,400 – 2,800 (FOB Shanghai) |
| Optical Design | Proportional-monitoring double-beam |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Scanning Step | 0.1 nm |
| Display | 128 × 64 dot-matrix LCD |
| Sample Holder | Automated 8-cell rotating cuvette holder (10 mm pathlength) |
| Data Interface | USB 2.0 |
| Power Supply | 220 V ±10%, 50 Hz or 110 V ±10%, 60 Hz |
| Dimensions (L×W×H) | 545 × 450 × 235 mm |
| Net Weight | 17.0 kg |
| Gross Weight | 26.0 kg |