| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | OxiTop Control AN6/AN12 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Differential Pressure Method |
| Pressure Range | 0–1500 hPa |
| Compliance | Designed for ISO 11734, ISO 10634, OECD 311, ASTM D5210, and EU Regulation (EC) No. 1069/2009 Annex VI biodegradability testing protocols |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | OxiTop®-IDS B6/B6M/B6M2.5 |
| Measurement Principle | Pressure Differential Method |
| Application | Soil Respiration, Biodegradability Testing, BOD Analysis (Lab-Based) |
| Compliance | DIN EN ISO 16072:2011-09 |
| Sample Volumes | 500 mL / 1.0 L / 2.5 L (B6M2.5) |
| Pressure Range | –500 to 1350 hPa (up to 1500 hPa with OxiTop®-IDS/B sensor head) |
| Data Logging Interval | 0.5 h to 180 days |
| CO₂ Absorbent Included | Yes |
| Nitrification Inhibitor Included | Yes (B6/B6M/AN series) |
| Stirring Base | IS 6 / IS 12 / IS 6-Var / IS 12-Var |
| Required Controller | Multi 3620 IDS Set WL or Multi 3630 IDS Set WL (except OxiTop®-IDS Set 6/12, which operates autonomously) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | OxiTop-i IS 6 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Pressure-Difference Method |
| BOD Range | 0–4000 mg/L |
| Sample Channels | 6 per system |
| Compliance | CE, EMC |
| Operating Temperature Compensation | Automatic (1–3 h delay based on sample temperature) |
| Pressure Measurement Range | 500–1250 hPa |
| Data Logging Interval | 0.5 h to 180 days |
| Bottle Volume | Fixed (standard 250 mL or 500 mL brown glass bottles) |
| Stirring Base | Integrated, continuous magnetic stirring |
| Display & Interface | 3-button operation, LED status indicator per measurement head |
| Optional Controller | Multi 3620/3630 IDS SET WL for remote configuration and real-time curve visualization |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | OxiTop® Control B/BM Soil Respiration Analyzer |
| Measurement Principle | Pressure-based CO₂ consumption/respiration monitoring via headspace oxygen depletion |
| Container Options | MG 1.0 (1000 mL) or PF 45/500 (500 mL) sealed vials with integrated OxiTop®-C stoppers or AD/SK adapters |
| Data Logging | Autonomous, battery-powered, up to 60 days continuous measurement per cycle |
| Output | mg O₂/L·d or µmol CO₂/g soil·h (calculated) |
| Compliance | Designed for ISO 11274, ISO 17402, OECD 207, ASTM D5988, and EU Regulation (EC) No 1107/2009 biodegradation testing protocols |