- All
- Favorite
- Popular
- Most rated
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | P 700IQ |
| Measurement Principle | Vanadomolybdate Photometric Colorimetry (PO₄–P) |
| Range 1 | 0.05–15.00 mg/L PO₄–P |
| Range 2 | 1–50 mg/L PO₄–P |
| Resolution | 0.05 mg/L (Range 1), 1 mg/L (Range 2) |
| Accuracy | ±2% or ±0.05 mg/L (Range 1), ±2% or ±1 mg/L (Range 2) |
| t₉₀ Response Time | <5 min |
| Minimum Measurement Interval | Adjustable to <5 min |
| Sample Temperature | 4–45 °C |
| pH Range | 5–9 |
| Operating Temperature | –20–40 °C |
| Storage Temperature | –20–50 °C |
| Reagent Consumption | 2500 mL per 8 months (Range 1), 2500 mL per 4 months (Range 2), 1000 mL cleaning solution per 4 months |
| Power Supply | 115/230 V AC |
| Dimensions | 678 × 780 × 395 mm |
| Weight | ~30 kg (excl. reagents) |
| Outputs | Analog (4–20 mA), IQ SENSOR NET 2020XT interface |
| Certifications | CE, cETLus |
| Enclosure Rating | IP65 (integrated cabinet) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | SensoLyt 700IQ |
| Part Number | 109170 |
| Sensor Type | Intelligent In-Line pH/ORP Electrode with Integrated Preamp & NTC Temperature Sensor |
| Output Signal | 4–20 mA / RS-485 (Modbus RTU) |
| Housing Material | PVDF or Titanium (depending on variant) |
| Pressure Rating | Up to 10 bar (SensoLyt SEA-HP), 6 bar standard |
| Operating Temperature | −5 to +60 °C (standard), up to +80 °C (SEA-HP) |
| IP Rating | IP68 |
| Compliance | EN 61326-1 (EMC), EN 61000-6-2/-6-4, ATEX/IECEx Zone 1 optional |
| Lightning Protection | Integrated transient voltage suppression circuit |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | FDO 700IQ |
| Part Number | 201650 |
| Measurement Principle | Green-light-based fluorescence quenching |
| Range (25°C) | 0–20.00 mg/L O₂, 0.0–200.0% saturation |
| Resolution | 0.01 mg/L O₂, 0.1% saturation |
| Accuracy | ±0.05 mg/L (<1 mg/L), ±0.1 mg/L (≥1 mg/L) |
| Repeatability | ±0.05 mg/L |
| Response Time (t₉₀) | <150 s |
| Temperature Range | –5°C to +60°C (sensor), –5°C to +50°C (compensation) |
| Pressure Rating | 10 bar (including cable) |
| Enclosure Rating | IP68 |
| Materials | POM/PVC/silicone membrane head, stainless steel body |
| Power Consumption | 0.7 W |
| Compliance | CE, cETLus, EN 61326 Class B, FCC Class A |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | TriOxmatic 700IQ |
| Sensor Type | Clark-type polarographic membrane electrode with potentiostatic 3-electrode system |
| Membrane Thickness | 50 µm hydrophobic Teflon® |
| Minimum Flow Rate | ≥0.5 cm/s |
| Response Time (t₉₀) | <180 s |
| Accuracy | ±1% of reading across full range |
| Operating Temperature | 0–50 °C |
| Output Signal | Digital (IQ Sensor Net protocol) |
| Compliance | EN ISO 5814, ASTM D888, USP <731>, GLP/GMP-ready data logging |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | TetraCon 700IQ |
| Electrode Configuration | Four-electrode (tetrapolar) |
| Measurement Principle | AC-driven four-pole conductivity measurement with automatic temperature compensation (ATC) |
| Conductivity Range | 0.01 µS/cm to 2 S/cm (typical, dependent on cell constant) |
| Temperature Range | 0–60 °C |
| Cell Constant | 0.475 cm⁻¹ (standard) |
| Output Signal | Analog 4–20 mA or digital Modbus RTU / SDI-12 (configurable) |
| Housing Material | PEEK + stainless steel 316L |
| IP Rating | IP68 |
| Compliance | EN ISO 7888, ASTM D1125, USP <645>, GLP-compliant data logging |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Distribution Status | Authorized Distributor |
| Import Status | Imported |
| Model | SENSORNET Online |
| Price Range | USD 25,000 – 125,000 |
Show next