Empowering Scientific Discovery

Shanghai Muchen Electronic Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelPhotoLab 6100 (VIS), PhotoLab 6600 (UV-VIS)
Optical DesignPseudo-Double-Beam
Wavelength Range320–1100 nm (PhotoLab 6100), 190–1100 nm (PhotoLab 6600)
Light SourceTungsten Halogen Lamp (6100), Xenon Flash Lamp (6600)
Wavelength Accuracy±1 nm
Spectral Bandwidth4 nm
Absorbance Range–3.3 to +3.3 A
Absorbance Resolution0.005 A (at A = 2.0) or 0.5% of reading
Photometric Repeatability±0.002 A (at A = 1.0)
Photometric Accuracy±0.003 A (A < 0.600 A), ±0.5% of reading (0.600–2.000 A)
Linearity<1% deviation (0–2.000 A, 340–900 nm)
Stray Light<0.1% (at 340 nm and 408 nm)
Cuvette RecognitionAutomatic (16 mm round, 10/20/50 mm square)
Data Storage1000 measurement records, 100 spectra (300–900 nm), 400 dynamic test series (150 values each)
Built-in Methods200 preprogrammed, 100 user-defined, 20 photometric analysis methods
InterfaceUSB-A (for USB drive, printer, barcode scanner), USB-B (PC connection), RS232 (PC/printer)
ComplianceCE, UL, IP30
Operating Temperature10–35 °C
Dimensions404 × 197 × 314 mm (W × H × D)
Weight~4.5 kg (without power supply)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelSenTix® 980
Measurement Range0–14.00 pH
Accuracy±0.004 pH
Temperature SensorNTC 30 kΩ
Reference Electrolyte3 mol/L KCl
Membrane Resistance< 600 MΩ
Shaft Length120 mm
Shaft Diameter12 mm
ConnectionIntegrated 1.5 m waterproof digital cable with IDS connector
Tip GeometryConical glass membrane
Electrolyte SystemLiquid-filled
Internal Signal ProcessingYes
QSC (Quality Sensor Control)Yes
Calibration Data StorageOn-board memory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelpHotoFlex STD
Wavelengths436, 517, 557, 594, 610, 690 nm
Wavelength Repeatability≤ 0.005 nm
Wavelength Accuracy±2 nm
Photometric Range−2.000 A to +2.000 A
Protection RatingIP67
Dimensions236 × 86 × 117 mm
Weight0.6 kg (without batteries)
Power Supply4 × AA alkaline batteries (up to 3,000 measurements)
Data Storage100 measurement sets
InterfaceRS232
Software UpgradeFree internet-based method updates
User-Defined MethodsUp to 50
Built-in Calibration Curves>140 pre-programmed for common water quality parameters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelpHotoFlex Turb
Wavelength Range436, 517, 557, 594, 610, 690, and 860 nm
Wavelength Repeatability≤ 0.005 nm
Wavelength Accuracy±2 nm
Photometric Range−2.000 A to +2.000 A
pH Range−2.00 to +16.00
ORP Range−1000 to +1000 mV
Turbidity Range0.01–1100 NTU/FNU
Temperature Range−5 °C to +100 °C
Data Storage Capacity1000 measurements
Protection RatingIP67
Power Supply4 × AA alkaline batteries (≈5000 measurements)
Dimensions236 × 86 × 117 mm
Weight0.6 kg (without batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelpH 3110
Instrument TypePortable
Parameter TypeSingle-Parameter (pH/mV/°C)
Measurement PrinciplePotentiometric (Glass Electrode / Reference Electrode System)
Resolution0.001 pH / 0.1 mV / 0.1 °C
Accuracy±0.005 pH (at 25 °C, range –2.000 to +19.999), ±0.1 mV (–1200.0 to +1200.0 mV), ±0.1 °C (–5.0 to +105.0 °C)
CalibrationAutomatic 1-/2-/3-point with buffer recognition (DIN/NIST/USA buffers)
Response Time≤15 s (t₉₀)
Repeatability<0.02 pH
Auto-Off DelayConfigurable from 10 min to 24 h
Battery LifeUp to 2500 h (4 × AA alkaline)
Enclosure RatingIP67
Operating Temperature–10 °C to +55 °C
Storage Temperature–25 °C to +65 °C
Dimensions180 × 80 × 55 mm
Weight0.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
Model2CA301 Cond 3310 SET 1
PortabilityPortable
Application EnvironmentLaboratory & Field
Conductivity Range0.0–1000 mS/cm
Accuracy±0.5%
Measurement ParametersConductivity, Resistivity, Salinity, TDS, Temperature
Calibration Points1–5-point
Temperature CompensationAutomatic (ATC), selectable reference temp (20 °C/25 °C)
Data Storage5000 automatic + 200 manual entries
IP RatingIP66/IP67
Response Time≤10 s
Electrode CompatibilityMulti-k-value (0.01–25.00 cm⁻¹), TetraCon 325 included
USB InterfaceFully waterproof
Battery LifeUp to 1000 h (backlight off), 100 h (backlight on)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelPH/ION 3310
Instrument TypePortable
Parameter TypeSingle-Parameter
Measurement ModespH, ORP, ISE, Temperature
CalibrationpH (1–5 points), ISE (2–7 points)
DisplayBacklit LCD
Data StorageManual (500 entries), Automatic (5000 entries)
GLP ComplianceYes
USB InterfaceUSB 1.1 (Type-B), cable length ≤ 3 m
Power4 × 1.5 V AA alkaline (800 h operation) or 4 × 1.2 V AA NiMH rechargeable
IP RatingIP67
Dimensions180 × 80 × 55 mm
Weight0.4 kg (without adapter)
Operating Temp.+5 °C to +55 °C
Storage Temp.−25 °C to +65 °C
pH Range−2.000 to +19.999 (res. 0.001, acc. ±0.005)
ORP−2500 to +2500 mV (res. 1 mV, acc. ±1 mV)
Temp.−5.0 to +105.0 °C (res. 0.1 °C, acc. ±0.1 °C)
ISE0.000–999999 in multiple units (mg/L, µmol/L, mmol/L, mg/kg, ppm, %) with resolution down to 0.001 and accuracy per NIST-traceable calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelSenTix 41
Instrument TypePortable
Parameter TypeSingle-Parameter (pH)
pH Range0–14
Temperature Range−5 to +80 °C
Glass Membrane Impedance300 MΩ at 25 °C
Reference SystemGelified Internal Buffer (pH 7.0 ± 0.25)
Junction TypeFibrous Diaphragm
Electrode Body MaterialNoryl
Electrode DimensionsØ12 mm × 120 mm
Cable Length1 m
Connector OptionsDIN or BNC
Integrated Temperature SensorNTC thermistor (30 kΩ)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
Instrument CompatibilityphotoFlex STD, photoFlex pH, photoFlex Turb, photoLab S6, photoLab S12, photoLab 6100, photoLab 6600, photoLab 7100, photoLab 7600
Test ParametersCOD, Ammonia-N, Total Nitrogen, Total Phosphorus, Heavy Metals (e.g., Cr, Cu, Ni, Zn, Pb)
FormatPre-filled Ready-to-Use Cuvettes & Reagent Kits
Calibration & QCCertified Standard Solutions & Reference Water Samples
Regulatory AlignmentCompliant with DIN EN ISO 15586, DIN 38405, DIN 38414, and EPA Method 410.4 (COD), EPA 350.1 (Ammonia), EPA 365.4 (Phosphate)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPinnacle
ModelCD-30
TypePocket-Sized Conductivity Meter
OriginUSA
Measurement Range0–1999 µS/cm and 0–19.99 mS/cm
Resolution1 µS/cm / 0.01 mS/cm
Accuracy±2% of reading
Temperature CompensationAutomatic, 0–50 °C
CalibrationAuto- or manual 1–2-point with buffer recognition
Electrode Diameter8 mm
DisplayLCD with auto-hold
Power2×CR2032 (3 V)
Battery Life~200 hours
Auto-OffAfter 8 min inactivity
Dimensions236 × 46 × 33 mm
Weight140 g
IP RatingIP66+
Standard KitMeter, replaceable electrode, calibration solutions, batteries, manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelCond 3110
PortabilityPortable
ApplicationLaboratory & Field Use
Conductivity Range0.0–1000 mS/cm
Accuracy±0.5% of reading
Temperature Range–5.0 to +105.0 °C
Temp. Accuracy±0.1 °C
Cell ConstantsFixed 0.475 cm⁻¹ or 1.0 cm⁻¹
Salinity Range0.0–70.0 ppt (IOT)
TDSCalculated
Auto-Temperature Compensation (ATC)Yes
Reference Temp20 °C / 25 °C
Calibration TimerBuilt-in
Display7-segment LCD with high-contrast, large-font digits
IP RatingIP66/IP67
Battery4 × 1.5 V AA or 4 × 1.2 V NiMH
Data StorageNone
InterfaceNone
ComplianceDesigned for GLP-compliant field and lab workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelpH 3310
Instrument TypePortable
Parameter TypeSingle-Parameter (pH/mV/Temperature)
pH Range–2.000 to 19.999
pH Accuracy±0.005
mV Range±2500 mV
mV Accuracy±1 mV
Temperature Range–5.0 to 105.0 °C
Temp. Accuracy±0.1 °C
Data Storage5000 automatic records
IP RatingIP66/IP67
Calibration1–5 point, auto-buffer recognition (DIN/NIST/WTW TEC, 16 buffers)
ATCYes
CMC (Continuous Measurement Control)Yes
DisplayBacklit graphical LCD
Power4 × AA alkaline or NiMH batteries (1000 h typical life)
InterfaceWaterproof USB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPONSEL (France)
OriginFrance
ModelPHEHT
Measurement PrincipleComposite Glass Electrode (pH), Platinum Redox Electrode (ORP), NTC Thermistor (Temperature)
pH Range0–14
pH Resolution0.01
pH Accuracy±0.1
ORP Range−1000 to +1000 mV
ORP Resolution0.1 mV
ORP Accuracy±2 mV
Temperature Range0.00–50.00 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.5 °C
Response Time<5 s
IP RatingIP68
Output InterfaceModbus RTU over RS-485 (standard), SDI-12 (optional)
Supply Voltage5–12 V DC
Standby Current25 µA
Active Current (1 Hz, RS-485)3.9 mA
Active Current (1 Hz, SDI-12)6.8 mA
Pulse Current500 mA
Dimensions (Ø × L)27/21 mm × 207 mm
Weight (sensor + 3 m cable)350 g
Housing MaterialsPVC, Delrin®, specialty pH glass, platinum, polyamide
Max Pressure Rating5 bar
CableArmored coaxial polyurethane cable, bare leads or Fischer connector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelSenTixSur
Instrument TypePortable
Parameter TypeSingle-Parameter (pH)
Membrane TypeFlat
Reference SystemReferid® Polymer Electrolyte (Maintenance-Free)
Junction TypeOpen-Ring
Membrane Resistance< 1 GΩ
pH Range2–13
Temperature Range0–50 °C
Shaft Length120 mm
Shaft Diameter12 mm
ConnectorS7 (Cable Not Included)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSM
OriginGermany
ModelTM39
Measurement RangespH 0–14, mV −1999 to +1999, Temperature −70 to +250 °C
Resolution0.01 pH, 1 mV, 0.1 °C
Temperature CompensationAutomatic (Pt100) or Manual
CalibrationAuto 2-/3-point pH calibration
DisplayLCD, 2-line × 4-digit
Power9 V battery (IEC 6F22)
InterfaceRS-232 (TM39-D variant)
Operating Environment0–50 °C
Dimensions (H×W×D)142 × 71 × 26 mm
Weight~145 g
Electrode ConnectionBNC (pH/ORP), Mini-DIN (temperature)
Compatible ElectrodeEGA142/TM39 (pH/Temp composite, Ø12 mm, 120 mm immersion, Pt1000 sensor, Ag/AgCl reference, 3 mol/L KCl gel electrolyte, max. 6 bar)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelSenTix 940
Measurement Range0.00–14.00 pH
Resolution0.01 pH
Temperature Range0–80 °C
Input Impedance>1 GΩ (at 25 °C)
Cable Length1.5 m
Connector Type4-pin IDS plug
Reference ElectrolytePolymer gel
Junction TypeFiber junction
NTC Temperature SensorIntegrated
Housing MaterialPPE/PS composite
Shaft Diameter4.3 mm
Minimum Bending Radius (fixed)20 mm
Minimum Bending Radius (flexible use)60 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelF 800DIN
Instrument TypePortable
Parameter TypeSingle-Parameter
Electrode Series800 Series ISE
Measured IonFluoride (F⁻), also compatible with Al³⁺, PO₄³⁻, Li⁺
pH Range5–7
Internal Reference ElectrodeIntegrated Ag/AgCl
Membrane TypeLanthanum Fluoride (LaF₃) crystalline membrane
Calibration Standard10 g/L NaF solution
ComplianceDIN EN ISO 10304-1, ASTM D1179, EPA Method 300.0
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelSenTixMic
Instrument TypePortable
Parameter TypeSingle-Parameter (pH)
Membrane Diameter3 mm or 5 mm
Reference System3 mol/L KCl aqueous electrolyte
Junction TypeCeramic or Platinum Wire
Temperature Range0–100 °C (ceramic), –5–100 °C (Pt wire)
Shaft Dimensions40/80 mm length × 12/5 mm diameter (Model 103647)
ConnectorS7 plug (no cable)
Re-fillableYes
Response Time<15 s (typical, per ISO 9712)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
TypePortable
Measurement ModeSingle-Parameter
Electrode Architecture500-Series (Half-Cell, Requires Separate Reference Electrode) / 800-Series (Integrated Reference Electrode, Composite Design)
Compatible IonsNH₄⁺, Pb²⁺, Br⁻, Cd²⁺, Ca²⁺, Cl⁻, CN⁻, F⁻, I⁻, K⁺, Cu²⁺, Na⁺, NO₃⁻, Ag⁺, S²⁻
Concentration Range (Typical)10⁻⁸–10⁻¹ mol/L (e.g., Cu²⁺) to saturation (e.g., F⁻)
Connector OptionsBNC or DIN
ComplianceDesigned for ASTM D6919, ISO 10304-2, USP <781>, and GLP/GMP-relevant measurement traceability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelphotoLab S6
Optical DesignPseudo-Double-Beam
Wavelength Range340–690 nm (6 fixed interference filters)
Cuvette Compatibility16 mm and 28 mm round cuvettes
Auto-Method SelectionYes (AutoSelect)
MemoChip SupportYes
ComplianceDesigned for ISO/IEC 17025-aligned routine analysis, supports GLP data integrity requirements
Software InterfaceStandalone operation with on-device method execution and result display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelSenTix 940-3
Measurement Range0.000–14.000 pH
Accuracy±0.004 pH
Temperature Range0–80 °C
Cable Length3 m
ElectrolytePolymer Gel (Gel-Filled)
Input Impedance>1 GΩ at 25 °C
Connector Type4-pin IDS (Intelligent Digital Sensor)
Housing MaterialPPE/PS Composite
Shaft Length120 mm
Shaft Diameter4.3 mm
Minimum Bending Radius20 mm (fixed), 60 mm (flexible use)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelSensoLyt® 900-P
Measurement Range0.000–12.000 pH
Accuracy±0.004 pH
Temperature SensorNTC 30 kΩ
Membrane Resistance< 400 MΩ at 25 °C
Operating Temperature0–80 °C
Electrode Length120 mm
Electrode Diameter12 mm
ConnectionDigital IDS interface (AS/IDS-x or IDS WLM-S compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelCond 7310
Measurement ParametersConductivity, Resistivity, Salinity, TDS, Temperature
Conductivity Range0.000 µS/cm to 1000 mS/cm
Accuracy±0.5% of reading ±1 digit
Electrode Constant Adjustment Range0.01 to 62.5 cm⁻¹
Temperature CompensationLinear, Non-Linear (nLF), or None
CalibrationUp to 10 stored calibration records
Data Storage500 manual + 5000 auto-stored readings
InterfaceUSB (with CSV export)
OptionalIntegrated thermal printer (58 mm width)
Power4×AA batteries or universal AC adapter
DisplayBacklit LCD with 7-segment numeric and status icons
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelphotoLab 7100 VIS
Optical DesignSingle-beam
DetectorCCD (Charge-Coupled Device)
Wavelength Range320–1100 nm
Wavelength Accuracy±1.0 nm
Wavelength Repeatability< 0.5 nm
Spectral Bandwidth4 nm
Stray Light≤0.01% T
Display7″ backlit color touchscreen
Sample HoldersAuto-identifying 16 mm round, 10/20/50 mm rectangular cuvettes with barcode recognition
Data Storage5,000 measurement values, 500 spectra, 400 kinetic curves
Built-in Methods>230 preprogrammed test protocols (e.g., free chlorine, nitrate, phosphate, COD)
Custom MethodsUp to 1,000 user-defined calibration curves
Reagent-Free Tests>50 methods requiring no chemical reagents
Interface1× USB-A, 1× USB-B, 1× Ethernet
ComplianceDesigned for GLP/GMP-aligned workflows
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0