| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | ADP600 |
| Type | Benchtop Polarimeter |
| Temperature Control | Peltier-based |
| Display | High-resolution 7.4" color touchscreen |
| Wavelength Options | Single, dual, or up to six discrete wavelengths (325 nm, 365 nm, 405 nm, 436 nm, 546 nm, 589 nm) |
| Measurement Range | ±89°A (extendable to –355°A to +355°A via method selection) |
| Resolution | 0.0001°A |
| Accuracy | ±0.003°A (@546 nm and 589 nm) |
| Temperature Range | 15–35 °C |
| Temp. Control Precision | ±0.2 °C |
| Temperature Setpoints | 20 °C and 25 °C (user-adjustable within 20–30 °C range per method) |
| Sample Cell Length | 5–200 mm |
| Cell Diameter | 3–8 mm |
| Optical Density Range | 0.0–3.0 OD |
| Calibration Modes | Sucrose, quartz, user-defined, or no compensation |
| Measurement Modes | Specific rotation, concentration (% w/w), invert sugar %, differential (A–B) % |
| Readout Time | 15–60 s (@546/589 nm, 20/20 °C instrument/sample) |
| Light Source | UV–Vis lamp (6 V, 2 A) with narrow-band interference filters |
| Interfaces | 4 × USB, 1 × Ethernet, 1 × RS232 |
| Power Supply | 100–250 V~, 50–60 Hz, <6 A |
| Regulatory Compliance | FDA 21 CFR Part 11, USP <781>, EP 2.2.7, JP XVI |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM300+ |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Prism Material | Synthetic Sapphire |
| Light Source | LED (≥100,000 hr lifetime) |
| Data Storage | >700 measurements |
| Compliance | GLP/GMP, USP <731>, Ph. Eur., BP |
| Interface | RS232 |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DR Series Digital Handheld |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes |
| Product Type | Handheld Refractometer |
| Construction | Full-metal body with thermal-insulating rubber grip |
| Prism cover | Slide-action flip cover |
| Sample application | Drop-on method |
| Sample temperature range | Compatible with both chilled and heated samples |
| Key Specifications (DR103L) | Brix 0–45%, resolution 0.1%, accuracy ±0.2% |
| Key Specifications (DR112) | Brix 28–65%, resolution 0.1%, accuracy ±0.2% |
| Key Specifications (DR122) | Brix 60–92%, resolution 0.1%, accuracy ±0.2% |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | Eclipse |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| IP Rating | IP66 |
| Construction | All-metal body with insulated rubber ergonomic grip |
| Prism Cover | Spring-loaded push-to-close mechanism |
| Zero Adjustment | Lockable fine-tuning screw |
| Sample Volume | < 1 mL |
| Compliance | Fully traceable serial-numbered units with calibration certificate supplied |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | OPTi Life Sciences Digital |
| Type | Handheld Refractometer |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes |
| IP Rating | IP65 |
| Construction | Stainless steel prism housing, ultrasonically welded waterproof enclosure |
| Calibration | Pure water zero-point calibration |
| Ergonomics | Human-centered design |
| Compliance | Designed for clinical, veterinary, and sports science applications per ISO 21748 (Refractometry — Guidance for the estimation of measurement uncertainty) and aligned with CLSI EP10-A3 (Preliminary Evaluation of Quantitative Clinical Laboratory Measurement Procedures) |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM960-C |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, ±0.03 °C accuracy |
| Display | 4-inch high-resolution color touchscreen |
| Resolution | 0.0001 RI / 0.1 °Brix |
| Measurement Range | 1.3000–1.7000 RI / 0–100 °Brix |
| Data Storage | 4,000 readings with full audit trail |
| Compliance | FDA 21 CFR Part 11, USP/EP/BP/JP, ASTM D2140, HACCP |
| Connectivity | 3× USB-A, 1× USB-B, 1× Ethernet, 1× RS232 |
| Sample Interface | Sapphire prism, 316 stainless steel & PEEK housing, Kalrez® seals |
| Light Source | LED at 589 nm (≥100,000 h lifetime) |
| Temperature Range | 10–80 °C (ambient-dependent), stability detection ±0.02 °C |
| Custom Scales | >20 preloaded (e.g., HFCS-3, Sucrose SG-3, Urea, PHR-MEAN), user-definable via PC software |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | OPTi Industrial Digital |
| Type | Handheld Refractometer |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes |
| IP Rating | IP65 |
| Construction | Stainless-steel prism housing, ultrasonically welded waterproof enclosure |
| Calibration | Pure water zero-point calibration |
| Prism Design | Shallow-depth prism plate for rapid cleaning |
| Ergonomics | Optimized handheld form factor |
| Compliance | Designed for GLP-compliant field and lab use in regulated industrial environments |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | OPTi RI 1.42 |
| Measurement Range | RI 1.33–1.42 |
| Resolution | 0.0001 RI |
| Accuracy | ±0.0003 RI |
| Temperature Compensation | Automatic (ATC) |
| IP Rating | IP65 |
| Display | Digital LCD |
| Prism Chamber | Shallow-profile, easy-clean design |
| Calibration | Pure water zero-point calibration |
| Form Factor | Handheld, ergonomic |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Type | Benchtop Refractometer |
| Model | E-Line |
| Temperature Control | Yes (Automatic Temperature Compensation) |
| Digital Display | Yes |
| Construction | All-metal body with heat-insulating rubber grip |
| Compliance | Designed to meet ISO 21748 and ASTM D1218 standards for refractive index measurement |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | OPTi Saline 28 |
| Type | Digital Handheld Refractometer |
| Measurement Scale | Salinity (% NaCl) |
| Range | 0–28% |
| Resolution | 0.1% |
| Accuracy | ±0.2% |
| Temperature Compensation | Automatic (ATC) |
| IP Rating | IP65 |
| Prism Material | Stainless-steel integrated prism plate |
| Housing | Ultrasonically welded, waterproof enclosure |
| Calibration | Pure water zero-point calibration |
| Compliance | Designed to meet ISO 2173 and ASTM D1152 standards for refractive index-based salinity determination |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | OPTi |
| Type | Handheld Refractometer |
| Temperature Compensation | Automatic (ATC) |
| Display | Digital LCD |
| IP Rating | IP65 |
| Construction | Stainless steel prism, ultrasonically welded waterproof housing |
| Calibration | Pure water zero-point calibration |
| Sample Compatibility | Aqueous solutions, juices, wines, worts, musts, syrups |
| Compliance | Designed and manufactured in accordance with ISO 21748 (Refractometry — Guidance for the use of refractometers), ASTM D1152 (Standard Test Method for Ethanol Content of Denatured Fuel Ethanol), and EU Regulation No. 1308/2013 (Wine sector standards) |