| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JHg2 |
| Price Range | USD 4,200 – 7,000 |
| Functionality | Single-Analyte Detection (Mercury Only) |
| Sample Format | Single-Sample Dedicated Use |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 min |
| Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JT-108JY |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Versatility | Grain, Legume, Leaf, and Processed Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Optical Reproducibility (CV) | ≤ 0.3% |
| Detection Channels | 10 parallel lateral-flow immunoassay (LFIA) readers |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BH2 |
| Price | USD 1,080 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Type | Dedicated Single-Sample Format |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 minutes |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | SZ-CY2 |
| Price | USD 530 (approx.) |
| Functionality | Single-Analyte Detection |
| Sample Type | Dedicated to Aqueous Samples |
| Wavelength Range | 380–630 nm |
| Analysis Time | ≤ 3 min |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SZ-LS2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-analyte Quantitative Detection |
| Sample Format | Single-sample, discrete measurement |
| Wavelength Range | 380–630 nm |
| Analysis Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (at fixed wavelength, n=6) |
| Optical Channels | 1 |
| Absorbance Range | 0.000–4.000 AU |
| Absorbance Resolution | 0.001 AU |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Baseline Stability | ≤0.3% drift over 3 min |
| Measurement Range (SO₄²⁻) | 5.0–250.0 mg/L as sulfate |
| Communication Interfaces | RS-232, USB 2.0 |
| Power Supply | AC 220 V ±10%, DC 5 V, or rechargeable Li-ion battery |
| Display | 4.5-inch color TFT-LCD touchscreen with full Chinese UI |
| Onboard Thermal Printer | Integrated embedded thermal printer |
| Data Storage | Internal non-volatile memory for ≥10,000 test records |
| Data Export | CSV via USB |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-1001AC |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Function Type | Multi-analyte Quantitative Detection System |
| Sample Compatibility | Solid and Liquid Extracts from Tea, Leafy Produce, and Herbal Matrices |
| Wavelength Range | 410–630 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability | ≤ 1.0% (Transmittance) |
| Optical Channels | 8 independent photometric channels |
| Absorbance Accuracy | ±2.0% T |
| Dark Current Drift | ≤0.5% over 3 min |
| Detection Limits | 5.0 mg/kg for all listed analytes |
| Linear Dynamic Range | 0–200 mg/kg (pyrethroids, organophosphates) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-102M |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Reader |
| Sample Format | Single-strip lateral flow assay (LFA) |
| Optical Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time per Test | ≤ 180 s |
| Photometric Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JCX-JC10 |
| Price | USD 495 (FOB Shanghai) |
| Function Type | Multi-analyte Screening System |
| Sample Compatibility | Liquid Alcoholic Beverages, Distillates, Blended Spirits, Fermented Liquors |
| Wavelength Range | 400–680 nm |
| Detection Time | <120 seconds per sample |
| Coefficient of Variation (CV) | <5% |
| Optical Channels | Single-beam photometric detection |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | JT-102DY |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Format | Single-strip, Lateral Flow Assay (LFA) Cartridge |
| Optical Wavelengths | 410 nm, 510 nm, 630 nm |
| Detection Time | ≤ 180 s per test |
| Repeatability (CV) | ≤ 0.3% |
| Detection Channels | 1 |
| Measurement Speed | < 0.5 s per image capture |
| Quantitative Precision | CV < 1% (using certified reference lateral flow strips) |
| Sensitivity Threshold | ≤ 0.001 OD unit (optical density) |
| Output Modes | Colorimetric analysis, C/T ratio calculation, Test line (T) and Control line (C) intensity quantification |
| Data Storage | 32 GB internal flash memory (≥100,000 assay records with full-image archiving) |
| Operating System | Windows 10 IoT Enterprise |
| Processor | Intel quad-core, 14 nm architecture |
| Display | 8.3-inch capacitive touchscreen (1280 × 800) |
| Connectivity | USB 2.0, Wi-Fi 802.11ac, Bluetooth 5.0, optional 4G LTE module |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Internal Battery | Rechargeable Li-ion, ≥24 h standby |
| Power Consumption | <10 W (operational) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | JT-108SC |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte Immunoassay Platform |
| Sample Compatibility | Universal for Aquatic Products (e.g., shrimp, fish, crab, mollusks) |
| Wavelength Range | 380–680 nm |
| Detection Time per Test | ≤ 180 s |
| Repeatability (CV) | ≤ 0.3% |
| Number of Detection Channels | 6 |
| Measurement Speed per Strip | < 1 s |
| Precision | CV < 1% (certified control strips), Inter-batch Variability < 3% |
| Sensitivity | LOD ≤ 0.001 µg/kg (matrix-dependent, per analyte-specific validation) |
| Output Modes | Colorimetric Intensity, C/T Ratio, Test Line (T), Control Line (C) Quantification |
| Interface | USB 2.0 |
| Network | Wi-Fi (802.11 b/g/n), RJ45 Ethernet, Optional 4G LTE Module |
| Power Supply | AC 220 V ±10%, 50 Hz (with optional Li-ion battery pack for field use) |
| Compliance | Designed to support ISO/IEC 17025-aligned laboratory workflows |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HYG-16YB |
| Price | USD 16,500 (approx.) |
| Function Type | Multi-analyte Detection Platform |
| Sample Compatibility | Universal for Animal Tissues, Blood, Oral Fluids, Swabs, and Processed Food Matrices (e.g., Dumpling Fillings) |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤60 min (including nucleic acid extraction and amplification) |
| Repeatability | CV ≤0.2% |
| Detection Channels | 16 independent optical channels |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LG2 |
| Function Type | Single-Analyte Dedicated Analyzer |
| Sample Type | Rapeseed Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Repeatability (RSD) | ≤0.2% |
| Optical Channels | 1 |
| Absorbance Display Range | 0.000–4.000 |
| Transmittance Display Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Baseline Stability (3 min) | ≤0.3% |
| Limit of Detection (LOD) | 10 µmol/g |
| Interface | USB |
| Power Supply | 220 V AC |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JS2 |
| Function Type | Single-Analyte Dedicated Analyzer |
| Sample Type | Rapeseed Only |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min |
| Repeatability | ≤0.2% |
| Optical Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Stability (3 min) | ≤0.3% |
| Limit of Detection (Erucic Acid) | 0.5% (w/w) |
| Interface | USB |
| Power Supply | AC 220 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JC2 |
| Price | USD 790 (FOB Shanghai) |
| Functionality | Single-Analyte Detection |
| Sample Format | Single-Sample Dedicated |
| Wavelength | 540 nm |
| Assay Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SPb-YS2 |
| Price | USD 1,380 (FOB Shanghai) |
| Function Type | Single-Analyte Detection |
| Sample Type | Single-Sample Dedicated |
| Wavelength | 540 nm |
| Detection Time | ≤ 3 min |
| Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Stability (3-min drift) | ≤0.3% |
| LOD (Nitrite) | 2.0 mg/kg |
| Measurement Range (Nitrite) | 0–200 mg/kg |
| Communication Interfaces | RS232, USB |
| Power Supply | Integrated Li-ion Battery, AC 220 V, DC 5 V |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SP-801SC |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-analyte Rapid Detection System |
| Sample Format | Single-sample per test cycle |
| Wavelengths | 410 nm, 510 nm, 630 nm |
| Assay Time | ≤ 180 s per sample |
| Photometric Repeatability | ≤ 0.2% (Transmittance), ≤ 0.3% (Absorbance) |
| Detection Channels | 8 parallel optical paths |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-LL2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Dedicated Single-Sample Cartridge/Well |
| Optical Wavelength | 630 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JCX-3SL |
| Price | USD 495 (FOB Shanghai) |
| Function Type | Multi-analyte (Clenbuterol, Ractopamine, Salbutamol) |
| Sample Compatibility | Urine, animal tissue, feed |
| Wavelength Range | 400–680 nm |
| Detection Time per Test | <2 min (instrument-assisted readout) |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 3 |
| Sensitivity | Clenbuterol — urine (3 ppb), tissue (5 ppb), feed (10 ppb) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JCX-105 |
| Price | USD 630 (FOB) |
| Function Type | Multi-analyte Screening Platform |
| Sample Compatibility | Universal for Liquid & Semi-solid Food Matrices |
| Optical Range | 400–680 nm |
| Assay Time per Test | <2 minutes |
| Coefficient of Variation (CV) | <5% |
| Detection Channels | 10 simultaneous visual/semi-quantitative assays |
| Kit Capacity | 14 validated food safety parameters with defined reagent yields |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-BJ2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-Analyte Dedicated Instrument |
| Sample Format | Single-Sample Mode |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds |
| Photometric Repeatability | ≤ 0.2% (at 540 nm) |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SP-Z2 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Type | Dedicated to Milk Powder & Liquid/Processed Dairy Matrices |
| Wavelength | 540 nm (Fixed-Channel Photometric Detection) |
| Assay Time | ≤180 seconds per sample |
| Photometric Repeatability | ≤0.2% CV |
| Optical Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-FM2 |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Functionality | Single-analyte Quantitative Detection |
| Sample Type | Dedicated to Honey Matrix Only |
| Optical Wavelength | 540 nm |
| Assay Time | ≤ 180 seconds per sample |
| Photometric Repeatability | ≤ 0.2% CV |
| Detection Channels | 1 |
| Display | 4.3-inch Color TFT Touchscreen |
| Absorbance Range | 0.000–4.000 (Resolution: 0.001) |
| Transmittance Range | 0.00–100.00% (Resolution: 0.01%) |
| Photometric Accuracy | ±2.0% T |
| Photometric Stability | ≤0.3% drift over 3 min |
| Detection Limits & Ranges | Fructose + Glucose — LOD 12.0%, Range 0–95.0% w/w |
| Interface | RS-232, USB 2.0 |
| Power Options | Internal Rechargeable Li-ion Battery, DC 5 V Input, AC 220 V ±10% 50/60 Hz |
| Dimensions & Weight | 220 × 160 × 85 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPb-JQ2 |
| Price | USD 1,380 (FOB Shanghai) |
| Functionality | Single-Analyte Quantitative Detection |
| Sample Format | Single-Sample Dedicated System |
| Optical Wavelength | 410 nm |
| Detection Time | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% |
| Detection Channels | 1 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP-NH2 |
| Price | USD 780 (FOB Shanghai) |
| Functionality | Single-Analyte Detection System |
| Sample Format | Single-sample cuvette-based assay |
| Wavelength Range | 400–680 nm |
| Analysis Time | <120 s per sample |
| Relative Standard Deviation (RSD) | <5% |
| Detection Channels | 1 |
| Detection Limit | 200.0 mg/kg |
| Quantification Range | 0–15,000 mg/kg |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability | ≤1.0% |
| Dark Current Drift | ≤0.5% over 3 min |
| Power Supply | AC 220 V / DC 12 V (with rechargeable 12 V Li-ion battery) |