- All
- Favorite
- Popular
- Most rated
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1217C |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interfaces | RS-232 and USB |
| Power Supply | 220 V ±10% AC |
| Dimensions (W×D×H) | 410 × 290 × 150 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RXHGZ-V1.0 |
| Detection Method | Rapid Colorimetric Assay |
| Measurement Range | 0–100% (Relative Inhibition) |
| Number of Channels | Multi-channel |
| Measurement Error | ±10% |
| Limit of Detection (LOD) | 0.05 ppm |
| Printing Medium | Thermal Adhesive Label Paper |
| Connectivity | Bluetooth 4.2 |
| Paper Width | 25–80 mm |
| Printable Width | 72 mm |
| Max Roll Diameter | 50 mm |
| Print Speed | 70 mm/s (Receipt), 40 mm/s (Label) |
| Power Supply | Rechargeable Built-in Lithium-ion Battery |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218ZF |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric) |
| Measurement Range | 0–100% Inhibition |
| Number of Spectrophotometric Channels | 12 |
| Number of Colloidal Gold Lateral Flow Channels | 3 |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (Transmittance) | ±2.0% T |
| Photometric Repeatability (Transmittance) | ≤0.2% T |
| Photocurrent Drift | ≤0.2% (over 3 min) |
| Measurement Accuracy | ±5% |
| LOD for Organophosphates & Carbamates | 0.2 ppm |
| Power Supply | AC 220 V ±10% |
| Display | 10.1-inch Capacitive Touchscreen (Android OS) |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, Optional 4G LTE Module |
| Internal Storage | ≥32 GB |
| Battery | Integrated Rechargeable Li-ion (up to 6 h operation) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-K100 |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Range | 0.5–1000 ppb |
| Number of Test Lines | 1 |
| Quantitative Accuracy (CV) | ≤1% |
| Limit of Detection (LOD) | 0.5 ppb |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218DJ |
| Detection Methods | Spectrophotometry & Colloidal Gold Immunochromatography |
| Measurement Range | 0–100% (Relative Inhibition or Signal Intensity) |
| Number of Channels | 12 (Spectrophotometric) + 3 (Colloidal Gold, expandable to 10) |
| Measurement Accuracy | ±5% |
| Absorbance Resolution | 0.001 A |
| Transmittance Resolution | 0.01% T |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Detection Limit | 0.2 ppm (for representative organophosphates and carbamates) |
| Display | 10.1-inch TFT-LCD touchscreen (1024 × 600), IP65-rated front panel, 400 cd/m² brightness |
| Operating System | Android 7.0, Quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage |
| Connectivity | Dual-band Wi-Fi, RJ45 Ethernet, Bluetooth 4.2, optional 3G/4G/5G module |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Export | USB 2.0 ×2, Cloud API support for real-time upload and traceability |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-3217C |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Detection Channels | 24 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 7-inch Color TFT Touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ≤2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interfaces | RS-232 and USB |
| Power Supply | AC 220 V ±10% |
| Dimensions (L×W×H) | 410 × 290 × 150 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JT-108NY |
| Detection Method | Colloidal Gold Immunochromatography with Spectrophotometric Quantification |
| Measurement Range | 0–100% relative signal intensity |
| Number of Channels | 10 |
| Measurement Error | <10% CV (at mid-range concentration) |
| Limit of Detection (LOD) | 0.2 ppm (matrix-dependent, typical for organophosphates and carbamates) |
| Measurement Speed | <1 s per test strip |
| Precision | Intra-assay CV <1% (standard reference strips), Inter-assay CV <3% |
| Output Parameters | Colorimetric intensity, C/T ratio, Test line (T) signal, Control line (C) signal |
| Power Supply | AC 220 V ±10%, 50 Hz (optional integrated Li-ion battery) |
| Connectivity | Wi-Fi (IEEE 802.11 b/g/n), RJ45 Ethernet, USB 2.0, optional 4G/LTE module |
| Display | 10.1-inch capacitive touchscreen, Android OS |
| Data Storage | Internal eMMC + microSD slot (up to 512 GB), >1 million records |
| Compliance | Designed to support traceability requirements aligned with China’s *Pilot Program for Edible Agricultural Product Qualification Certificate* (2020), QR code generation compliant with GB/T 38137–2019 (Traceability Code for Agricultural Products) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | JT-DB10B |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Range | 0.00–1000 ppb |
| Detection Limit (LOD) | 0.01 ppm |
| Accuracy | ±5% |
| Channel Count | 1 |
| Measurement Speed | <2 s per test |
| Display | 5-inch capacitive touchscreen (Android OS) |
| Power Supply | Built-in rechargeable lithium battery |
| Data Output | C/T line intensity, CT ratio, colorimetric quantification |
| Connectivity | Wi-Fi, Bluetooth, USB 2.0 |
| Compliance | Aligns with MOA Notice No. 102 (2022), “Three-Year Action Plan for Residue Control in Edible Agricultural Products”, and Technical Guidance for Cowpea, Leek & Celery Quality Safety Management |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-2418C |
| Price | USD 2,500 (approx.) |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 10.1-inch TFT-LCD touchscreen (1024×600), IP65-rated front panel |
| Operating System | Android 7.0 (Quad-core, 1.8 GHz, 2 GB RAM, 16 GB internal storage + microSD expansion) |
| Photometric Range | 0.000–4.000 A / 0.00–100.00% T |
| Photometric Resolution | 0.001 A / 0.01% T |
| Photometric Accuracy | ±1.5% T |
| Photometric Repeatability | ≤0.2% T |
| Dark Current Drift | ≤0.2% (3 min) |
| Power Supply | AC 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-815C |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Number of Channels | 8 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 4.5-inch high-resolution color LCD touchscreen |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ≤2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Wavelength | 410 nm |
| Data Storage Capacity | 10,000 test records |
| Communication Interfaces | RS232 and USB |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-2417C |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–99.00% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interface | USB |
| Power Supply | 220 V ±10% AC |
| Dimensions (L×W×H) | 410 × 290 × 150 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1618C |
| Detection Method | Enzyme Inhibition (Spectrophotometric) |
| Measurement Range | 0–100% Inhibition |
| Number of Channels | 16 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 10.1-inch TFT LCD Touchscreen (1024×600), IP65-rated front panel |
| Operating System | Android 7.0 (Quad-core, 1.8 GHz, 2 GB RAM, 16 GB internal storage + microSD expansion) |
| Optical Performance | Absorbance range 0.000–4.000 A |
| Throughput | Up to 180 samples/hour |
| Connectivity | Dual USB 2.0 ports, Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 3G/4G/5G module, GPS/AGPS |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Compliance | Designed per GB 5009.199–2003 and NY/T 448–2001 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-1217LS |
| Detection Method | Enzyme Inhibition (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift (3 min) | ≤0.3% |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Interface | RS232 & USB |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | CNY-8S |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Channels | 8 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 7-inch Color TFT Touchscreen |
| Wavelength | 410 nm (±2 nm) |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (Transmittance) | ±2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Repeatability | ≤5% |
| Power Supply | AC 220 V ±10% / Built-in Rechargeable Lithium Battery |
| Communication Interfaces | RS-232, USB |
| Compliance | GB 5009.199–2003, NY/T 448–2001 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-100C |
| Detection Method | Enzyme Inhibition (Test Strip-Based) |
| Measurement Range | 0–99.9% inhibition rate |
| Detection Limit | 0.05 ppm |
| Accuracy | ±10% |
| Repeatability | ≤5% |
| Channel Count | 1 |
| Display | Color LCD |
| Power Supply | Integrated Lithium Battery (8 h continuous operation) |
| Dimensions | 175 × 100 × 85 mm |
| Connectivity | Bluetooth 4.0 |
| Data Output | Wireless transmission to regulatory platforms & mobile app integration for traceability and certificate generation |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1618 |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition |
| Number of Channels | 16 |
| Measurement Error | ±10% |
| Limit of Detection (LOD) | 5% Inhibition |
| Display | 10.1-inch TFT LCD Touchscreen (1024×600) |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±1.5% T |
| Photometric Repeatability | ≤0.2% T |
| Dark Current Drift | ≤0.2% (3 min) |
| Power Supply | AC 220 V ±10% |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, Optional 3G/4G/5G Module, GPS/AGPS |
| Operating System | Android 7.0 (Quad-Core, 1.8 GHz, 2 GB RAM, 16 GB Storage) |
| IP Rating | IP65 (Front Panel) |
| Data Export | Excel via USB or SD card |
| Throughput | Up to 180 samples/hour |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218C |
| Detection Method | Enzyme Inhibition Rate (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±1.5% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (3 min) |
| Power Supply | AC 220 V ±10% |
| Display | 10.1-inch capacitive touchscreen (1024 × 600), IP65-rated front panel, 400 cd/m² brightness |
| OS | Android 7.0, quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage + microSD expansion |
| Connectivity | Dual USB 2.0, Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 3G/4G/5G module, GPS/AGPS |
| Data Export | Excel (.xlsx) via USB drive |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-12K |
| Detection Method | Enzyme Inhibition Rate Method |
| Measurement Range | 0–100% |
| Number of Channels | 12 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Temperature Control Range | 30–50 °C ±0.5 °C |
| Preheating Time Setting | 1–99 min |
| Reaction Time Setting | 1–99 min |
| Power Supply | AC 220 V / DC 12 V / Internal Rechargeable Battery (3.6 V / 1400 mAh) |
| Dimensions | 325 × 100 × 40 mm |
| Weight | ~600 g |
| Carrying Case Dimensions | 400 × 290 × 120 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JT-DB10NY |
| Price | USD 1,050 (FOB Shanghai) |
| Measurement Range | 0–1000 ppm |
| Number of Detection Channels | 1 |
| Detection Method | Colloidal Gold Immunochromatography |
| Measurement Accuracy | ±5% |
| Limit of Detection (LOD) | 0.01 ppm |
| Detection Time | <2 s per test |
| Display | 5-inch capacitive touchscreen (Android OS) |
| Power Supply | Rechargeable Li-ion battery (operational autonomy ≥8 h) |
| Data Output | C/T line intensity ratio, chromaticity value, qualitative/quantitative result classification |
| Connectivity | Wi-Fi, Bluetooth 4.2, USB 2.0 |
| Data Management | Cloud synchronization, local storage (≥10,000 records), CSV export |
| Compliance | Aligned with MOA Notice No. 102 (2022), “Three-Year Action Plan for Illegal Drug Control and Residue Reduction in Edible Agricultural Products”, and Technical Guidance for Quality & Safety Control of Cowpea, Leek, and Celery (MOA, 2023) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1218D |
| Detection Method | Enzyme Inhibition Rate (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Spectrophotometric Channels | 12 |
| Number of Colloidal Gold Lateral Flow Channels | 3 (expandable to 10) |
| Measurement Accuracy | ±5% |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (over 3 min) |
| LOD for Organophosphates & Carbamates | 0.2 ppm |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1617C |
| Price | USD 2,500 (FOB Shanghai) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Channels | 16 |
| Measurement Error | ≤ ±10% |
| Limit of Detection (LOD) | 0.3 ppm for organophosphates and carbamates |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–99.99% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤ ±2.0% |
| Photometric Repeatability (Transmittance) | ≤ ±0.2% |
| Photocurrent Drift | ≤ ±0.2% (within 3 min) |
| Inhibition Rate Display Range | 0.00–99.99% |
| Inhibition Rate Repeatability | ≤ ±5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interface | USB |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 410 × 290 × 150 mm |
| Display | 7-inch color TFT LCD touchscreen with full Chinese GUI |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-4S |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Channels | 8 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 4.3-inch Color TFT Touchscreen |
| Wavelength | 410 nm (±2 nm) |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Photometric Repeatability | ≤0.2% T |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Power Supply | AC 220 V ±10% and Rechargeable Li-ion Battery |
| Communication Interfaces | RS-232 and USB |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CNY-96 |
| Price | USD 7,800 (FOB Shanghai) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 96-well microplate format |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm (for organophosphates & carbamates) |
| Optical Wavelengths | 410 nm, 450 nm, 540 nm, 630 nm |
| Bandwidth | 8 nm ±1 nm |
| Absorbance Read Range | 0.000–3.500 Abs |
| Max Absorbance Range | 0.000–4.500 Abs |
| Resolution | 0.001 Abs (display), 0.0001 Abs (internal ADC) |
| Linearity (r) | ≥0.995 |
| Repeatability | ±1.0% or ±0.007 Abs |
| Accuracy | ±0.5% or ±0.005 Abs |
| Calibration Modes | Two-point, Linear Regression, Logarithmic, Exponential, Power, and Multi-point % Inhibition |
| Measurement System | 8-channel optical fiber array with simultaneous 96-well scanning |
| Detection Time | 5 sec/wavelength (single), 7 sec/wavelength (dual) |
| Plate Shaking | Adjustable speed and duration |
| Display | 7-inch color TFT capacitive touchscreen (with stylus support |
| Input Language | Chinese & English (full IME support for Chinese sample/unit names) |
| Data Storage | Internal 16 GB SD card — supports ≥1,000 assay protocols and ≥1,000,000 test records |
| Print Output | Integrated thermal printer (Chinese-language report templates) |
| Connectivity | RS-232, RJ-45 Ethernet, dual USB-A, SD card slot |
| Optional Modem Module | PSTN-based remote diagnostics, firmware update, and encrypted data transmission |
| Operating Environment | 10–40 °C, 20–85% RH (non-condensing) |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-817C |
| Price | USD 1,350 (FOB Shanghai) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Number of Channels | 8 |
| Measurement Error | ≤ ±10% |
| Limit of Detection (LOD) | 0.3 ppm (for common organophosphates and carbamates) |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Absorbance Resolution | 0.001 |
| Photometric Accuracy (Transmittance) | ≤ ±2.0% |
| Photometric Repeatability (Transmittance) | ≤ ±0.2% |
| Photocurrent Drift | ≤ ±0.2% (within 3 min) |
| Inhibition Rate Display & Measurement Range | 0–100% |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤ ±5% |
| Internal Data Storage Capacity | 10,000 test records |
| Display | 7.0-inch color TFT-LCD touchscreen (800 × 480 resolution) |
| Communication Interfaces | RS-232, USB 2.0 |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W × D × H) | 410 × 290 × 150 mm |
| Weight | 4.2 kg |
Show next