BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionD₂ Lamp + Self-Absorption Method
Spectral Resolution0.2 nm
Sensitivity≤0.025 µg/mL for 1% absorption
RSD (Precision)≤0.5%
Cu Detection Limit≤0.006 µg/mL
Wavelength Range190–900 nm
Wavelength Accuracy±0.2 nm across full range
Wavelength Repeatability±0.1 nm
Spectral Bandwidth Options0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm
Baseline Drift (Static)≤0.002 ABS/30 min (Cu)
Baseline Drift (Dynamic, Ignition)≤0.004 ABS/30 min (Cu)
Mn Doublet ResolutionResolves 279.5/279.8 nm with valley-to-peak energy ratio <30% at 0.2 nm SBW
Lamp Holder4-lamp turret (6-lamp optional)
Flame Burner Heads100 mm air–acetylene
Safety InterlocksAutomatic gas cutoff on low pressure, power failure, flameout, or burner mismatch
Dimensions700 × 500 × 430 mm
Weight80 kg
Grating Density1800 lines/mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Spectral Resolution0.2 nm
Sensitivity (Cu)>0.3 A at 5 ppm
RSD (Precision)<0.3%
Detection Limit (Cu)<0.004 µg/mL
Wavelength Range190–900 nm
Slit Widths0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability0.1 nm
Baseline Drift0.002 A / 30 min
Background CorrectionD₂ Lamp & Self-Reversal
Characteristic Concentration (Cu)≤0.025 µg/mL / 1%
Weight65 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeGraphite Furnace AAS
ModelAA6810 (Visual Graphite Furnace)
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionD₂ Lamp + Self-Reversal Method
Resolution0.2 nm
Sensitivity≤0.5% (Cu, Absorbance >0.8 ABS)
Precision (RSD)≤0.5%
Detection Limit (Cd, GF-AAS)<0.3 pg
Max Ramp Rate≥3000 °C/s
Temperature RangeAmbient to 3000 °C
Characteristic Mass (Cd)≤0.4×10⁻¹² g
(Cu)≤10×10⁻¹² g
Temperature Control Accuracy≤1%
Dimensions700 × 550 × 440 mm
Weight80 kg
Power Requirement6000 W (peak)
Safety FeaturesOvercurrent Protection, Argon Pressure Monitoring, Overtemperature Cut-off
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame AAS
ModelAA6810 (Single-Flame Configuration)
Optical SystemSingle-Beam
MonochromatorPlane Grating
DetectorPhotomultiplier Tube (PMT)
Spectral Resolution0.2 nm
SensitivityCu 5 ppm, Absorbance > 0.3 A
Precision (RSD)< 0.3%
Detection Limit (Cu)< 0.004 µg/mL
Wavelength Range190–900 nm
Slit Widths0.1, 0.2, 0.7, 2.0 nm (motorized selection)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability0.2 nm
Baseline Drift≤0.0035 A / 30 min
Background CorrectionD₂ Lamp & Self-Reversal Methods
Characteristic Concentration (Cu)≤0.025 µg/mL / 1%
Precision (Cu)≤0.5%
Weight65 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeManufacturer
Instrument TypeFlame AAS
ModelAA3510
Wavelength Range190–900 nm
Light Source4/6-lamp turret
Wavelength Repeatability±0.1 nm
Wavelength Accuracy±0.2 nm across full range
Spectral Bandwidth Options0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm
Resolution0.2 nm (resolves Mn doublet at 279.5/279.8 nm, valley-to-peak energy ratio <30%)
MonochromatorPlane grating (1800 lines/mm)
Optical SystemSingle-beam
DetectorPhotomultiplier tube (PMT)
Background CorrectionD₂ lamp + self-absorption method
Background Correction Capacity≥50× at 1 ABS background signal
Static Baseline Drift≤0.002 ABS/30 min (Cu)
Dynamic Baseline Drift (ignition)≤0.004 ABS/30 min (Cu)
Sensitivity≤0.025 µg/mL for 1% absorption
Detection Limit (Cu)≤0.006 µg/mL
Precision (RSD)≤0.5% (Cu, A > 0.8 ABS)
Flame SystemsAir–acetylene (100 mm burner head)
Safety FeaturesAutomatic gas cutoff on low pressure, power interruption, flameout, or burner mismatch
Dimensions700 × 500 × 430 mm
Weight80 kg
Power Supply220 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal Method
Spectral Resolution0.2 nm
SensitivityCu 5 ppm → Absorbance > 0.3 A
Repeatability (RSD)< 0.3%
Detection LimitCu < 0.004 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (China-made)
ModelAA6810
Instrument TypeHydride Generation Accessory for Atomic Absorption Spectrometry
Monochromator ElementPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Spectral Resolution0.2 nm
SensitivityCu 5 ppm → Absorbance > 0.3 A
Repeatability (RSD)< 0.3%
Detection Limit (Cu)< 0.004 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame + Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal
Resolution0.2 nm
Sensitivity≤0.5% (Cu, Absorbance >0.8 AU)
Repeatability (RSD)<0.5%
Detection Limit (Cu)<0.004 µg/L
Detection Limit (Cd)<0.3 pg
Characteristic Mass (Cd)≤0.4×10⁻¹² g
Characteristic Mass (Cu)≤10×10⁻¹² g
Temperature Control Accuracy≤1%
Max Ramp Rate≥3000 °C/s
Furnace Temp RangeRoom Temp to 3000 °C
Dimensions700 × 550 × 440 mm
Weight80 kg
Power Supply220 V AC
Peak Power6000 W
Safety FeaturesOvercurrent Protection, Argon Pressure Monitoring, Overtemperature Cut-off