BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionD₂ Lamp + Self-Absorption Method
Spectral Resolution0.2 nm
Sensitivity≤0.025 µg/mL for 1% absorption
RSD (Precision)≤0.5%
Cu Detection Limit≤0.006 µg/mL
Wavelength Range190–900 nm
Wavelength Accuracy±0.2 nm across full range
Wavelength Repeatability±0.1 nm
Spectral Bandwidth Options0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm
Baseline Drift (Static)≤0.002 ABS/30 min (Cu)
Baseline Drift (Dynamic, Ignition)≤0.004 ABS/30 min (Cu)
Mn Doublet ResolutionResolves 279.5/279.8 nm with valley-to-peak energy ratio <30% at 0.2 nm SBW
Lamp Holder4-lamp turret (6-lamp optional)
Flame Burner Heads100 mm air–acetylene
Safety InterlocksAutomatic gas cutoff on low pressure, power failure, flameout, or burner mismatch
Dimensions700 × 500 × 430 mm
Weight80 kg
Grating Density1800 lines/mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
ModelCary Eclipse Fluorescence Spectrophotometer
Light SourcePulsed Xenon Lamp
Wavelength Scan Speed24,000 nm/min
Data Acquisition RateUp to 80 points/sec (steady-state)
Detection RangeExtended to 900 nm
DetectorRed-Sensitive Photomultiplier Tube (PMT)
Excitation/Emission ModesFluorescence, Phosphorescence, Chemiluminescence/Bioluminescence, Time-Resolved Phosphorescence
Sample CompartmentAmbient-light-immune design (open-lid operation supported)
Optional AccessoriesMicroplate Reader (384-well), Rapid Mixing Unit, BioMelt Thermal Denaturation System
Minimum Sample Volume< 0.5 mL (sub-picomolar fluorescein detection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model5975T
Mass Range1.8–1050 amu
Dynamic Range6 orders of magnitude
Mass ResolutionUnit mass resolution (tunable via tuning)
Maximum Scan Rate12,500 amu/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Spectral Resolution0.2 nm
Sensitivity (Cu)>0.3 A at 5 ppm
RSD (Precision)<0.3%
Detection Limit (Cu)<0.004 µg/mL
Wavelength Range190–900 nm
Slit Widths0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability0.1 nm
Baseline Drift0.002 A / 30 min
Background CorrectionD₂ Lamp & Self-Reversal
Characteristic Concentration (Cu)≤0.025 µg/mL / 1%
Weight65 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional OriginDomestic (China)
ModelGMA3610
Price RangeUSD 42,000 – 56,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeGraphite Furnace AAS
ModelAA6810 (Visual Graphite Furnace)
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionD₂ Lamp + Self-Reversal Method
Resolution0.2 nm
Sensitivity≤0.5% (Cu, Absorbance >0.8 ABS)
Precision (RSD)≤0.5%
Detection Limit (Cd, GF-AAS)<0.3 pg
Max Ramp Rate≥3000 °C/s
Temperature RangeAmbient to 3000 °C
Characteristic Mass (Cd)≤0.4×10⁻¹² g
(Cu)≤10×10⁻¹² g
Temperature Control Accuracy≤1%
Dimensions700 × 550 × 440 mm
Weight80 kg
Power Requirement6000 W (peak)
Safety FeaturesOvercurrent Protection, Argon Pressure Monitoring, Overtemperature Cut-off
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame AAS
ModelAA6810 (Single-Flame Configuration)
Optical SystemSingle-Beam
MonochromatorPlane Grating
DetectorPhotomultiplier Tube (PMT)
Spectral Resolution0.2 nm
SensitivityCu 5 ppm, Absorbance > 0.3 A
Precision (RSD)< 0.3%
Detection Limit (Cu)< 0.004 µg/mL
Wavelength Range190–900 nm
Slit Widths0.1, 0.2, 0.7, 2.0 nm (motorized selection)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability0.2 nm
Baseline Drift≤0.0035 A / 30 min
Background CorrectionD₂ Lamp & Self-Reversal Methods
Characteristic Concentration (Cu)≤0.025 µg/mL / 1%
Precision (Cu)≤0.5%
Weight65 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeManufacturer
Instrument TypeFlame AAS
ModelAA3510
Wavelength Range190–900 nm
Light Source4/6-lamp turret
Wavelength Repeatability±0.1 nm
Wavelength Accuracy±0.2 nm across full range
Spectral Bandwidth Options0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm
Resolution0.2 nm (resolves Mn doublet at 279.5/279.8 nm, valley-to-peak energy ratio <30%)
MonochromatorPlane grating (1800 lines/mm)
Optical SystemSingle-beam
DetectorPhotomultiplier tube (PMT)
Background CorrectionD₂ lamp + self-absorption method
Background Correction Capacity≥50× at 1 ABS background signal
Static Baseline Drift≤0.002 ABS/30 min (Cu)
Dynamic Baseline Drift (ignition)≤0.004 ABS/30 min (Cu)
Sensitivity≤0.025 µg/mL for 1% absorption
Detection Limit (Cu)≤0.006 µg/mL
Precision (RSD)≤0.5% (Cu, A > 0.8 ABS)
Flame SystemsAir–acetylene (100 mm burner head)
Safety FeaturesAutomatic gas cutoff on low pressure, power interruption, flameout, or burner mismatch
Dimensions700 × 500 × 430 mm
Weight80 kg
Power Supply220 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelGMA3710
Price RangeUSD 42,000 – 56,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
ModelP200
Detection PrincipleGC-FID (Gas Chromatography with Flame Ionization Detection)
Sample Path Temperature120–200 °C (adjustable, full-path heated)
DetectorMicro-FID with 10⁷ dynamic linear range
Column Oven Max Temp200 °C
Analysis Cycle for NMHC30 s
Detection Range0–50,000 ppm
LOD≤0.03 mg/m³
RepeatabilityRSD ≤0.5%
Accuracy±1% of full scale
Dimensions410 × 280 × 235 mm
Weight≤9 kg
Battery Life>6 h
Operating Ambient−15 to 50 °C, 10–90% RH
Carrier Gas ControlElectronic Pressure Control (EPC), pressure resolution 0.001 psi
ComplianceHJ 1012–2018, HJ 38–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
ModelGMA3660
OriginShanghai, China
ManufacturerSynpec Instrument Co., Ltd.
Price RangeUSD 42,000 – 56,000 (FOB Shanghai)
ComplianceGB/T 42027-2022, HJ 195-2023, HJ 200-2023, HJ/T 198-2005, HJ/T 197-2005, HJ 199-2023
Detection ModesNH₃-N, S²⁻, NO₃⁻-N, NO₂⁻-N, TN, Kjeldahl-N
Light SourceDeuterium Lamp (with optional Hg lamp for mercury analysis)
DetectorCCD Diode Array
Key FeaturesAutomated Flow Injection Sampling, Integrated UV Digestion-Dilution Module for Total Nitrogen, On-line Oxidation for Ammonia-N, Cold Trap + Auto-Dehydration System, Closed Reaction-Separation Cell, TCS (Temperature-Controlled Separation) System, Electronic Pressure Monitoring & Alarm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal Method
Spectral Resolution0.2 nm
SensitivityCu 5 ppm → Absorbance > 0.3 A
Repeatability (RSD)< 0.3%
Detection LimitCu < 0.004 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
ModelM3000 Micro GC
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Detection PrincipleMicro-Electro-Mechanical Systems (MEMS)-Based Thermal Conductivity Detection (μTCD)
Detector Pool Volume200 nL
Detection Limit0.5 ppm (for H₂, CO, CH₄, etc., in N₂ carrier)
Analysis Time< 30 s per channel (multi-channel parallel operation)
Column TypeCapillary micro-column (ID ≤ 0.15 mm)
Power SupplyInternal rechargeable Li-ion battery (8 h continuous operation)
Carrier GasIntegrated miniature high-pressure gas cylinder (N₂ or He)
Communication InterfacesRS-485, MODBUS RTU, digital/analog I/O
SoftwareOnboard embedded OS with method editor, real-time data processing, and automated report generation
ComplianceDesigned to support GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Region of OriginDomestic (China)
ModelP200GC
Price RangeUSD 14,000 – 43,000
Dimensions410 mm (L) × 280 mm (W) × 235 mm (H)
Weight≤10 kg
Analysis CycleNMHC: ≥1 min
BTEX≥5 min
Measurement Range0–50,000 ppm
LOD0.05 ppm
RepeatabilityRSD ≤1%
Accuracy±1% of full scale
Power SupplyIntegrated rechargeable battery, >6 h runtime
Operating Temperature10–45 °C
Detection PrincipleFlame Ionization Detection (FID) with capillary column separation
Sample PathFully heated from inlet to detector (up to 220 °C)
ConnectivityIndustrial-grade Wi-Fi, USB, Ethernet, optional thermal printer interface
ComplianceDesigned for field deployment in accordance with EPA Method 25A, ASTM D6348, and ISO 11843-2 for trace hydrocarbon quantification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelN300-VOCS
Price RangeUSD 14,000 – 70,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGMA3760
Price RangeUSD 42,000 – 56,000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model8454
Instrument ArchitectureDual-Wavelength
Detector TypePhotodiode Array (PDA)
Wavelength Range190 nm – 1100 nm
Automation LevelAutomatic Wavelength Scanning
Spectral BandwidthNot Specified
Wavelength AccuracyNot Specified
Stray LightNot Specified
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
ModelUV6010
Software CategoryUV-Vis Spectroscopy Data Acquisition & Analysis
Supported OSWindows 98/2000/NT/XP
Calibration Equations6 types (Linear, Quadratic, Cubic, Logarithmic, Exponential, Polynomial)
Data Export Formats.dat and .txt
Wavelength CalibrationBuilt-in reference-based correction
Sample Re-read FunctionEnabled
On-screen Help SystemContext-sensitive, integrated
Report OutputComprehensive summary reports, calibration curves, signal time traces, and acquisition parameters
Printer CompatibilityUniversal Windows driver support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
ModelCary 660 FTIR
Instrument PrincipleFourier Transform Infrared (FTIR)
Spectral RangeStandard Mid-IR (4000–400 cm⁻¹)
Spectral Resolution≤ 0.25 cm⁻¹ (user-selectable down to 0.1 cm⁻¹)
Signal-to-Noise Ratio≥ 45,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak)
DetectorHigh-performance DTGS or optional MCT
BeamsplitterKBr or ZnSe (mid-IR optimized)
InterferometerPrecision-machined, dynamically aligned Michelson with HeNe laser reference
Scan SpeedUp to 20 kHz mirror velocity
Data FormatCompatible with ASTM E1421, JCAMP-DX v6.0, and ISO 14153
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (China-made)
ModelAA6810
Instrument TypeHydride Generation Accessory for Atomic Absorption Spectrometry
Monochromator ElementPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Spectral Resolution0.2 nm
SensitivityCu 5 ppm → Absorbance > 0.3 A
Repeatability (RSD)< 0.3%
Detection Limit (Cu)< 0.004 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelAA6810
PriceUSD 420 (est.)
Software TypeAtomic Absorption Spectroscopy (AAS) – Hydride Generation Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
ModelP200OEM
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
Price RangeUSD 14,000 – 42,000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelAA4510 (Hydride Generation Workstation)
PriceUSD 1,250 (excl. tax & licensing)
Software TypeAtomic Absorption Spectroscopy (AAS) – Hydride Generation Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSynpec
ModelSP7210
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Measurement PrinciplePotassium Permanganate Titrimetric Oxidation (COD<sub>Mn</sub>)
Measurement Range0–6 mg/L as O<sub>2</sub>
RepeatabilityRSD ≤ 2.5%
Sample Capacity54 positions
Digestion Time30 min at boiling temperature (100 °C)
Digestion ModeAutomated water bath with constant temperature and liquid level control
Titration Delivery PrecisionAdjustable single-dose volume from 0.01 to 0.07 mL
Titration Endpoint DetectionColorimetric endpoint recognition
Sample ThroughputOne sample per 5 minutes
Sample IntroductionThree-axis robotic arm (X/Y/Z) with basket-style tray loading
Reagent DeliveryHigh-accuracy peristaltic pump for KMnO<sub>4</sub>, H<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>OX solutions
ComplianceGB 11892–1989