| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Spectral Resolution | 0.2 nm |
| Sensitivity | ≤0.025 µg/mL for 1% absorption |
| RSD (Precision) | ≤0.5% |
| Cu Detection Limit | ≤0.006 µg/mL |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm across full range |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm |
| Baseline Drift (Static) | ≤0.002 ABS/30 min (Cu) |
| Baseline Drift (Dynamic, Ignition) | ≤0.004 ABS/30 min (Cu) |
| Mn Doublet Resolution | Resolves 279.5/279.8 nm with valley-to-peak energy ratio <30% at 0.2 nm SBW |
| Lamp Holder | 4-lamp turret (6-lamp optional) |
| Flame Burner Heads | 100 mm air–acetylene |
| Safety Interlocks | Automatic gas cutoff on low pressure, power failure, flameout, or burner mismatch |
| Dimensions | 700 × 500 × 430 mm |
| Weight | 80 kg |
| Grating Density | 1800 lines/mm |
| Brand | Agilent Technologies |
|---|---|
| Model | Cary Eclipse Fluorescence Spectrophotometer |
| Light Source | Pulsed Xenon Lamp |
| Wavelength Scan Speed | 24,000 nm/min |
| Data Acquisition Rate | Up to 80 points/sec (steady-state) |
| Detection Range | Extended to 900 nm |
| Detector | Red-Sensitive Photomultiplier Tube (PMT) |
| Excitation/Emission Modes | Fluorescence, Phosphorescence, Chemiluminescence/Bioluminescence, Time-Resolved Phosphorescence |
| Sample Compartment | Ambient-light-immune design (open-lid operation supported) |
| Optional Accessories | Microplate Reader (384-well), Rapid Mixing Unit, BioMelt Thermal Denaturation System |
| Minimum Sample Volume | < 0.5 mL (sub-picomolar fluorescein detection) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5975T |
| Mass Range | 1.8–1050 amu |
| Dynamic Range | 6 orders of magnitude |
| Mass Resolution | Unit mass resolution (tunable via tuning) |
| Maximum Scan Rate | 12,500 amu/s |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity (Cu) | >0.3 A at 5 ppm |
| RSD (Precision) | <0.3% |
| Detection Limit (Cu) | <0.004 µg/mL |
| Wavelength Range | 190–900 nm |
| Slit Widths | 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Drift | 0.002 A / 30 min |
| Background Correction | D₂ Lamp & Self-Reversal |
| Characteristic Concentration (Cu) | ≤0.025 µg/mL / 1% |
| Weight | 65 kg |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GMA3610 |
| Price Range | USD 42,000 – 56,000 |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Graphite Furnace AAS |
| Model | AA6810 (Visual Graphite Furnace) |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Resolution | 0.2 nm |
| Sensitivity | ≤0.5% (Cu, Absorbance >0.8 ABS) |
| Precision (RSD) | ≤0.5% |
| Detection Limit (Cd, GF-AAS) | <0.3 pg |
| Max Ramp Rate | ≥3000 °C/s |
| Temperature Range | Ambient to 3000 °C |
| Characteristic Mass (Cd) | ≤0.4×10⁻¹² g |
| (Cu) | ≤10×10⁻¹² g |
| Temperature Control Accuracy | ≤1% |
| Dimensions | 700 × 550 × 440 mm |
| Weight | 80 kg |
| Power Requirement | 6000 W (peak) |
| Safety Features | Overcurrent Protection, Argon Pressure Monitoring, Overtemperature Cut-off |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | AA6810 (Single-Flame Configuration) |
| Optical System | Single-Beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Precision (RSD) | < 0.3% |
| Detection Limit (Cu) | < 0.004 µg/mL |
| Wavelength Range | 190–900 nm |
| Slit Widths | 0.1, 0.2, 0.7, 2.0 nm (motorized selection) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Drift | ≤0.0035 A / 30 min |
| Background Correction | D₂ Lamp & Self-Reversal Methods |
| Characteristic Concentration (Cu) | ≤0.025 µg/mL / 1% |
| Precision (Cu) | ≤0.5% |
| Weight | 65 kg |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Flame AAS |
| Model | AA3510 |
| Wavelength Range | 190–900 nm |
| Light Source | 4/6-lamp turret |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm across full range |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm |
| Resolution | 0.2 nm (resolves Mn doublet at 279.5/279.8 nm, valley-to-peak energy ratio <30%) |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | D₂ lamp + self-absorption method |
| Background Correction Capacity | ≥50× at 1 ABS background signal |
| Static Baseline Drift | ≤0.002 ABS/30 min (Cu) |
| Dynamic Baseline Drift (ignition) | ≤0.004 ABS/30 min (Cu) |
| Sensitivity | ≤0.025 µg/mL for 1% absorption |
| Detection Limit (Cu) | ≤0.006 µg/mL |
| Precision (RSD) | ≤0.5% (Cu, A > 0.8 ABS) |
| Flame Systems | Air–acetylene (100 mm burner head) |
| Safety Features | Automatic gas cutoff on low pressure, power interruption, flameout, or burner mismatch |
| Dimensions | 700 × 500 × 430 mm |
| Weight | 80 kg |
| Power Supply | 220 V AC |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GMA3710 |
| Price Range | USD 42,000 – 56,000 |
| Brand | Synpec |
|---|---|
| Model | P200 |
| Detection Principle | GC-FID (Gas Chromatography with Flame Ionization Detection) |
| Sample Path Temperature | 120–200 °C (adjustable, full-path heated) |
| Detector | Micro-FID with 10⁷ dynamic linear range |
| Column Oven Max Temp | 200 °C |
| Analysis Cycle for NMHC | 30 s |
| Detection Range | 0–50,000 ppm |
| LOD | ≤0.03 mg/m³ |
| Repeatability | RSD ≤0.5% |
| Accuracy | ±1% of full scale |
| Dimensions | 410 × 280 × 235 mm |
| Weight | ≤9 kg |
| Battery Life | >6 h |
| Operating Ambient | −15 to 50 °C, 10–90% RH |
| Carrier Gas Control | Electronic Pressure Control (EPC), pressure resolution 0.001 psi |
| Compliance | HJ 1012–2018, HJ 38–2017 |
| Brand | Synpec |
|---|---|
| Model | GMA3660 |
| Origin | Shanghai, China |
| Manufacturer | Synpec Instrument Co., Ltd. |
| Price Range | USD 42,000 – 56,000 (FOB Shanghai) |
| Compliance | GB/T 42027-2022, HJ 195-2023, HJ 200-2023, HJ/T 198-2005, HJ/T 197-2005, HJ 199-2023 |
| Detection Modes | NH₃-N, S²⁻, NO₃⁻-N, NO₂⁻-N, TN, Kjeldahl-N |
| Light Source | Deuterium Lamp (with optional Hg lamp for mercury analysis) |
| Detector | CCD Diode Array |
| Key Features | Automated Flow Injection Sampling, Integrated UV Digestion-Dilution Module for Total Nitrogen, On-line Oxidation for Ammonia-N, Cold Trap + Auto-Dehydration System, Closed Reaction-Separation Cell, TCS (Temperature-Controlled Separation) System, Electronic Pressure Monitoring & Alarm |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm → Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu < 0.004 µg/mL |
| Brand | Synpec |
|---|---|
| Model | M3000 Micro GC |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Principle | Micro-Electro-Mechanical Systems (MEMS)-Based Thermal Conductivity Detection (μTCD) |
| Detector Pool Volume | 200 nL |
| Detection Limit | 0.5 ppm (for H₂, CO, CH₄, etc., in N₂ carrier) |
| Analysis Time | < 30 s per channel (multi-channel parallel operation) |
| Column Type | Capillary micro-column (ID ≤ 0.15 mm) |
| Power Supply | Internal rechargeable Li-ion battery (8 h continuous operation) |
| Carrier Gas | Integrated miniature high-pressure gas cylinder (N₂ or He) |
| Communication Interfaces | RS-485, MODBUS RTU, digital/analog I/O |
| Software | Onboard embedded OS with method editor, real-time data processing, and automated report generation |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | P200GC |
| Price Range | USD 14,000 – 43,000 |
| Dimensions | 410 mm (L) × 280 mm (W) × 235 mm (H) |
| Weight | ≤10 kg |
| Analysis Cycle | NMHC: ≥1 min |
| BTEX | ≥5 min |
| Measurement Range | 0–50,000 ppm |
| LOD | 0.05 ppm |
| Repeatability | RSD ≤1% |
| Accuracy | ±1% of full scale |
| Power Supply | Integrated rechargeable battery, >6 h runtime |
| Operating Temperature | 10–45 °C |
| Detection Principle | Flame Ionization Detection (FID) with capillary column separation |
| Sample Path | Fully heated from inlet to detector (up to 220 °C) |
| Connectivity | Industrial-grade Wi-Fi, USB, Ethernet, optional thermal printer interface |
| Compliance | Designed for field deployment in accordance with EPA Method 25A, ASTM D6348, and ISO 11843-2 for trace hydrocarbon quantification |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | N300-VOCS |
| Price Range | USD 14,000 – 70,000 |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GMA3760 |
| Price Range | USD 42,000 – 56,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8454 |
| Instrument Architecture | Dual-Wavelength |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 nm – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | Not Specified |
| Wavelength Accuracy | Not Specified |
| Stray Light | Not Specified |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | UV6010 |
| Software Category | UV-Vis Spectroscopy Data Acquisition & Analysis |
| Supported OS | Windows 98/2000/NT/XP |
| Calibration Equations | 6 types (Linear, Quadratic, Cubic, Logarithmic, Exponential, Polynomial) |
| Data Export Formats | .dat and .txt |
| Wavelength Calibration | Built-in reference-based correction |
| Sample Re-read Function | Enabled |
| On-screen Help System | Context-sensitive, integrated |
| Report Output | Comprehensive summary reports, calibration curves, signal time traces, and acquisition parameters |
| Printer Compatibility | Universal Windows driver support |
| Brand | Agilent Technologies |
|---|---|
| Model | Cary 660 FTIR |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Spectral Range | Standard Mid-IR (4000–400 cm⁻¹) |
| Spectral Resolution | ≤ 0.25 cm⁻¹ (user-selectable down to 0.1 cm⁻¹) |
| Signal-to-Noise Ratio | ≥ 45,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak) |
| Detector | High-performance DTGS or optional MCT |
| Beamsplitter | KBr or ZnSe (mid-IR optimized) |
| Interferometer | Precision-machined, dynamically aligned Michelson with HeNe laser reference |
| Scan Speed | Up to 20 kHz mirror velocity |
| Data Format | Compatible with ASTM E1421, JCAMP-DX v6.0, and ISO 14153 |
| Compliance | Designed for GLP/GMP environments |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AA6810 |
| Instrument Type | Hydride Generation Accessory for Atomic Absorption Spectrometry |
| Monochromator Element | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm → Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit (Cu) | < 0.004 µg/mL |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AA6810 |
| Price | USD 420 (est.) |
| Software Type | Atomic Absorption Spectroscopy (AAS) – Hydride Generation Module |
| Brand | Synpec |
|---|---|
| Model | P200OEM |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Price Range | USD 14,000 – 42,000 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | AA4510 (Hydride Generation Workstation) |
| Price | USD 1,250 (excl. tax & licensing) |
| Software Type | Atomic Absorption Spectroscopy (AAS) – Hydride Generation Module |
| Brand | Synpec |
|---|---|
| Model | SP7210 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Principle | Potassium Permanganate Titrimetric Oxidation (COD<sub>Mn</sub>) |
| Measurement Range | 0–6 mg/L as O<sub>2</sub> |
| Repeatability | RSD ≤ 2.5% |
| Sample Capacity | 54 positions |
| Digestion Time | 30 min at boiling temperature (100 °C) |
| Digestion Mode | Automated water bath with constant temperature and liquid level control |
| Titration Delivery Precision | Adjustable single-dose volume from 0.01 to 0.07 mL |
| Titration Endpoint Detection | Colorimetric endpoint recognition |
| Sample Throughput | One sample per 5 minutes |
| Sample Introduction | Three-axis robotic arm (X/Y/Z) with basket-style tray loading |
| Reagent Delivery | High-accuracy peristaltic pump for KMnO<sub>4</sub>, H<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>OX solutions |
| Compliance | GB 11892–1989 |