| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE300B + AKTA Prime |
| Power Supply | 220 V ± 20 V, 50 Hz ± 0.5 Hz |
| Motor Power | 200 W |
| Total Column Capacity | 260 mL |
| Sample Loop Volume | 20 mL |
| Dimensions (W×D×H) | 563 × 638 × 368 mm |
| Rotation Speed Range | 0–1000 rpm |
| Optimal Separation Speed | 700–900 rpm (stepless frequency-controlled) |
| Flow Rate Range | 0.1–30 mL/min |
| Typical Separation Flow Rate | 1.5–2.0 mL/min |
| Maximum System Pressure | 2 MPa |
| UV Detection Wavelengths | 254 nm & 280 nm (Hg lamp + fixed filters) |
| optional filters | 313, 365, 405, 436, 546 nm |
| Temperature Control Module | 15–40 °C (±0.5 °C accuracy), external recirculating water bath required (flow rate: 1–10 L/min) |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-300B |
| Configuration | Vertical triple-column HSCCC system with dual six-port valves |
| Separation Capacity | mg–g scale |
| Column Volume | 280 mL |
| Sample Loop | 20 mL |
| Rotation Speed Range | 0–1000 rpm (stepless frequency-controlled) |
| Optimal Separation Speed | 700–1000 rpm |
| Flow Rate Range | 0.1–30 mL/min |
| Recommended Separation Flow Rate | 2.0–4.0 mL/min |
| Temperature Control | 15–40 °C (±0.5 °C), external water bath interface, circulation flow 1–10 L/min |
| Power Supply | 220 V ±20 V, 50 Hz ±0.5 Hz |
| Max Operating Pressure | 2 MPa |
| Dimensions (W×D×H) | 330 × 600 × 550 mm |
| Power Consumption | 300 W |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-300V |
| Column Capacity | 300 mL |
| Sample Injection Volume | 20 mL |
| Dimensions (W×D×H) | 330 × 600 × 550 mm |
| Rotation Speed Range | 0–1000 rpm |
| Separation Speed Range | 700–900 rpm (stepless frequency-controlled) |
| Flow Rate Range | 0.1–30 mL/min |
| Separation Flow Rate | 0.5–4.0 mL/min |
| Maximum System Pressure | 2 MPa |
| UV Detection Wavelengths | 214, 254, 280, 340, 365, 405 nm (optional full-spectrum detector available) |
| Temperature Control Range | 15–40 °C (±0.5 °C accuracy |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-300A HSCCC |
| Power Supply | 220 V ± 20 V, 50 Hz ± 0.5 Hz |
| Motor Power | 200 W |
| Column Configuration | Triple-spiral coiled column assembly |
| Rotational Speed Range | 700–900 rpm (infinitely variable frequency control) |
| Flow Rate Range | 0.1–30 mL/min (adjustable in 0.1 mL/min increments) |
| Maximum System Pressure | 2 MPa |
| Tubing Volume | 260 mL |
| Injection Volume | 20 mL |
| UV Detector Wavelengths | 254 nm & 280 nm (dual fixed-wavelength) |
| Temperature Control Module | 15–40 °C (±0.5 °C accuracy), compatible with external recirculating chiller (flow rate: 1–10 L/min) |
| Dimensions (W×D×H) | 563 × 638 × 368 mm |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-1000A |
| Power Supply | 220 V ± 20 V, 50 Hz ± 0.5 Hz |
| Motor Power | 750 W |
| Column Configuration | Triple-spiral coiled column assembly (patented) |
| Rotational Speed Range | 400–600 rpm (infinitely variable frequency-controlled) |
| Pump Flow Rate | 0.1–90 mL/min |
| UV Detector Wavelengths | 254 nm & 280 nm |
| Temperature Control Range | 15–40 °C (±0.5 °C accuracy |
| Temperature Control Flow Rate | 1–20 L/min |
| Tubing Volume | 1000 mL |
| Sample Injection Volume | 80 mL |
| Dimensions (W×D×H) | 830 × 570 × 1050 mm |
| Compliance | Designed for GLP-compliant natural product isolation workflows |
| Software Interface | RS-232/USB-enabled data logging and instrument control |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-200V |
| Column Capacity | 200 mL |
| Sample Injection Volume | 20 mL |
| Dimensions (W×D×H) | 330 × 600 × 550 mm |
| Rotation Speed Range | 0–1000 rpm |
| Separation Speed | 700–900 rpm (stepless frequency-controlled) |
| Flow Rate Range | 0.1–30 mL/min |
| Separation Flow Rate | 1.5–2.0 mL/min |
| Maximum System Pressure | 2 MPa |
| UV Detector Wavelengths | 254 nm & 280 nm (dual fixed-wavelength) |
| Temperature Control Range | 15–40 °C (±0.5 °C accuracy) |
| Circulating Cooling Fluid Flow | 1–10 L/min |
| Column Configuration | Three serially connected helical separation columns |
| Valve System | Dual six-port switching valves |
| Detection Mode | Real-time online UV detection |
| Instrument Orientation | Vertical architecture |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-300C |
| Separation Column | Triple-column with patented switching valve |
| Switching Valve Configuration | Quad-channel, dual six-port valves |
| Total System Capacity | 300 mL |
| Sample Loop Volume | 20 mL |
| Typical Separation Scale | mg to 10 g |
| Rotation Speed Range | 0–1000 rpm (infinitely variable frequency-controlled) |
| Optimal Separation Speed | 700–900 rpm |
| Flow Rate Range | 0.1–50.0 mL/min |
| Recommended Separation Flow Rate | 5.0–30.0 mL/min |
| Maximum System Pressure | 2 MPa |
| Temperature Control Range | 5–40 °C |
| Dimensions (W×D×H) | 500 × 760 × 830 mm |
| Power Consumption | 500 W |
| Net Weight | 180 kg |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-5000A |
| Power Supply | 220 V ±20 V, 50 Hz ±0.5 Hz |
| Host Power | 1500 W |
| Total Column Capacity | 4800 mL |
| Sample Injection Volume | 200 mL |
| Dimensions (W×D×H) | 730 × 1100 × 1122 mm |
| Rotational Speed Range | 0–600 rpm |
| Optimal Separation Speed | 400–550 rpm (infinitely variable frequency control) |
| Mobile Phase Flow Rate | 0.1–180 mL/min |
| Typical Separation Flow Rate | 20–50 mL/min |
| System Pressure Limit | 0–2 MPa |
| UV Detector Wavelengths | 254 nm & 280 nm |
| Temperature Control Module (external chiller required) | 15–40 °C, ±0.5 °C accuracy, coolant flow rate 1–20 L/min |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-20A |
| Separation Capacity | µg–mg scale |
| Column Capacity | 20 mL |
| Injection Volume | 20 µL (standard), optional loops: 5 µL–2 mL |
| Injector Valve | Rheodyne 7725i |
| Rotation Speed Range | 0–2000 rpm |
| Operational Separation Speed | 1400–2000 rpm (stepless frequency-controlled) |
| Flow Rate Range | 0.1–5.0 mL/min |
| Recommended Separation Flow Rate | 0.5–1.5 mL/min |
| System Pressure Rating | 0–2 MPa |
| UV Detector Wavelengths | 254 nm & 280 nm (optional full-spectrum detector) |
| Temperature Control Range | 15–40 °C (via external recirculating chiller), accuracy ±0.5 °C, coolant flow rate 1–10 L/min |
| Power Supply | 220 V ±10%, 50/60 Hz, 300 W |
| Dimensions (W×D×H) | 330 × 600 × 550 mm |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-30A |
| Column Capacity | 30 mL |
| Injection Loop Volume | 1 mL |
| Rotational Speed Range | 0–1400 rpm (infinitely variable frequency control) |
| Recommended Operating Speed | 1300 rpm |
| Flow Rate Range | 0.1–10.0 mL/min |
| Separation Flow Rate | 0.5–5.0 mL/min |
| Maximum System Pressure | 2 MPa |
| UV Detection Wavelengths | 214, 254, 280, 340, 365, 405 nm (optional full-spectrum detector available) |
| Temperature Control Range (via external circulator) | 15–40 °C (±0.5 °C accuracy) |
| Circulating Fluid Flow Rate | 1–10 L/min |
| Dimensions (W×D×H) | 330 × 600 × 550 mm |
| Power Supply | 220 V ±20 V, 50 ±0.5 Hz |
| Power Consumption | 200 W |
| Brand | Tongtian |
|---|---|
| Origin | Shanghai, China |
| Model | TBE-1000A |
| Column Capacity | 1000 mL |
| Sample Injection Volume | 80 mL |
| Dimensions (W×D×H) | 628 × 918 × 1048 mm |
| Rotation Speed Range | 0–600 rpm |
| Separation Speed | 400–550 rpm (stepless frequency-controlled) |
| Flow Rate Range | 0.1–90 mL/min |
| Separation Flow Rate | 5.0–10 mL/min |
| Maximum System Pressure | 2 MPa |
| UV Detector Wavelengths | 254 nm, 280 nm |
| Temperature Control Module (external water bath interface) | 15–40 °C, ±0.5 °C accuracy, coolant flow rate 1–20 L/min |