BrandTongtian
OriginShanghai, China
ModelTBP5002T
Flow Range0.1–50.0 mL/min
Pressure Range0–2.0 MPa
Wetted MaterialsPure Titanium (Grade 2), Sapphire, Zirconia Ceramic
ComplianceGLP-ready architecture, RS232/USB communication interface, audit-trail-capable software logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP-5002F
Flow Range0.1–50.0 mL/min
Pressure Range0–2.0 MPa
Pressure Pulsation≤ 0.10 MPa
Pressure Accuracy≤ 0.05 MPa
Flow Setting Error≤ 1%
Flow Repeatability≤ 1%
Wetted MaterialsSapphire, PTFE, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 260 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelFlash 200
Pressure Range0–5.0 MPa
Flow Rate Range0.1–200.0 mL/min
Pressure Pulsation≤ 0.08 MPa
Flow Accuracy≤ ±1%
Flow Precision (RSD)≤ 1%
Pressure Accuracy≤ ±0.05 MPa
Wetted MaterialsSapphire, 316L Stainless Steel, Zirconia Ceramic
InterfaceRS232
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBE300B + AKTA Prime
Power Supply220 V ± 20 V, 50 Hz ± 0.5 Hz
Motor Power200 W
Total Column Capacity260 mL
Sample Loop Volume20 mL
Dimensions (W×D×H)563 × 638 × 368 mm
Rotation Speed Range0–1000 rpm
Optimal Separation Speed700–900 rpm (stepless frequency-controlled)
Flow Rate Range0.1–30 mL/min
Typical Separation Flow Rate1.5–2.0 mL/min
Maximum System Pressure2 MPa
UV Detection Wavelengths254 nm & 280 nm (Hg lamp + fixed filters)
optional filters313, 365, 405, 436, 546 nm
Temperature Control Module15–40 °C (±0.5 °C accuracy), external recirculating water bath required (flow rate: 1–10 L/min)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP-1010T
Flow Range0.1–10.0 mL/min
Pressure Range0–10.0 MPa
Pressure Pulsation≤ 0.08 MPa
Pressure Accuracy≤ ±0.05 MPa
Flow Setting Error≤ ±1%
Flow Repeatability≤ ±1%
Wetted MaterialsPure Titanium, Sapphire, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 260 × 160 mm
Weight12 kg
Communication InterfaceRS232 (standard), PLC-compatible (customizable)
DisplayBacklit LCD
Safety FeaturesBuilt-in Overpressure Protection, Automatic Flow Calibration, Integrated Degassing System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP5002K
Pressure Range0–2.0 MPa
Flow Rate Range0.1–50.0 mL/min
Pressure Pulsation≤ 0.08 MPa
Pressure Accuracy≤ ±0.05 MPa
Flow Setting Error≤ ±1%
Flow Precision (RSD)≤ 1%
Wetted MaterialsPEEK, Sapphire, Zirconia Ceramic
InterfaceRS232
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP-5020
Pressure Range0–20.0 MPa
Flow Rate Range0.1–50.0 mL/min
Pressure Pulsation≤ 0.10 MPa
Pressure Accuracy≤ ±0.05 MPa
Flow Setting Error≤ ±1%
Flow Repeatability≤ ±1%
Wetted MaterialsSapphire, 316L Stainless Steel, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 260 × 160 mm
Weight12 kg
Communication InterfaceRS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP1010
Pressure Range0–10.0 MPa
Flow Rate Range0.1–10.0 mL/min
Pressure Pulsation≤ 0.08 MPa
Pressure Accuracy≤ ±0.05 MPa
Flow Setting Error≤ ±1%
Flow Precision (RSD)≤ 1%
Wetted MaterialsSapphire, 316L Stainless Steel, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Communication InterfaceRS232 (standard), optional PLC integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelGrad50
Pressure Range0–5.0 MPa
Flow Rate Range0.1–50.0 mL/min
Gradient Accuracy±1%
Flow Increment Resolution0.1 mL/min
Mixing Ratio Range0.0–100%
Pressure Pulsation≤0.10 MPa
Pressure Accuracy≤±0.05 MPa
Flow Rate Accuracy≤±1% (0.1–10 mL/min), ≤±2% (10–50 mL/min)
Flow Precision (RSD)≤1%
Wetted MaterialsSapphire, 316L Stainless Steel, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP1002S
Flow Range0.1–10.0 mL/min
Pressure Range0–2.0 MPa
Pressure Pulsation≤0.01 MPa
Flow Accuracy≤±0.5%
Flow Repeatability≤±0.5%
Pressure Accuracy≤±0.10 MPa
Wetted MaterialsSapphire Ball Valves, Ceramic Plungers
Input Voltage220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions (W×D×H)270 × 400 × 190 mm
Weight17 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP-5010T
Flow Range0.1–50.0 mL/min
Pressure Range0–10.0 MPa
Pressure Pulsation≤ 0.10 MPa
Pressure Accuracy≤ 0.05 MPa
Flow Setting Error≤ 1%
Flow Repeatability≤ 1%
Wetted MaterialsPure Titanium, Sapphire, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 260 × 160 mm
Weight12 kg
Communication InterfaceRS232 (standard), PLC-compatible (customizable)
Safety FeaturesBuilt-in Overpressure Protection, Automatic Flow Calibration, Integrated Air-Elimination System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
ModelFlash 300
OriginShanghai, China
ConstructionDual-piston positive displacement
Flow Range0.1–300.0 mL/min
Pressure Range0–2.0 MPa
Pressure Pulsation≤ 0.08 MPa
Flow Accuracy≤ ±1%
Flow Precision (RSD)≤ 1%
Pressure Accuracy≤ ±0.05 MPa
Wetted MaterialsSapphire, 316L stainless steel, zirconia ceramic
Communication InterfaceRS232
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP5010S
Flow Rate0.1–50.0 mL/min
Maximum Pressure0–10.0 MPa
Pressure Pulsation≤ 0.02 MPa
Flow Accuracy≤ ±0.5%
Flow Repeatability≤ ±0.5%
Pressure Accuracy≤ ±0.20 MPa
Wetted Materials Options316L SS / Titanium / PEEK / PTFE
Drive SystemSealed Dual-Piston Mechanism with Microprocessor Control
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions (W×D×H)270 × 400 × 190 mm
Weight17 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBE-300B
ConfigurationVertical triple-column HSCCC system with dual six-port valves
Separation Capacitymg–g scale
Column Volume280 mL
Sample Loop20 mL
Rotation Speed Range0–1000 rpm (stepless frequency-controlled)
Optimal Separation Speed700–1000 rpm
Flow Rate Range0.1–30 mL/min
Recommended Separation Flow Rate2.0–4.0 mL/min
Temperature Control15–40 °C (±0.5 °C), external water bath interface, circulation flow 1–10 L/min
Power Supply220 V ±20 V, 50 Hz ±0.5 Hz
Max Operating Pressure2 MPa
Dimensions (W×D×H)330 × 600 × 550 mm
Power Consumption300 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP-1002K
Flow Range0.1–10.0 mL/min
Pressure Range0–2.0 MPa
Pressure Pulsation≤ 0.08 MPa
Pressure Accuracy≤ ±0.05 MPa
Flow Setting Error≤ ±1%
Flow Repeatability≤ ±1%
Wetted MaterialsPEEK, Sapphire, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 260 × 160 mm
Weight12 kg
Communication InterfaceRS232 (standard), PLC-compatible (customizable)
Safety FeaturesBuilt-in Overpressure Protection, Automatic Flow Calibration, Integrated Air-Elimination System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
ModelTBD-3000
Detection Wavelengths214, 230, 260, 280 nm (customizable)
Noise Level≤ 0.0004 A
Drift≤ 0.002 A/h (at constant ambient temperature)
Optical Path Length3 mm
Flow Cell Volume212 µL
Display128 × 32 LCD
Power Consumption≤ 25 W
Input Voltage220 V ± 10%, 50 Hz
Operating Temperature0–40 °C
Relative Humidity≤ 70 % RH
Dimensions (W × H × D)360 × 160 × 255 mm
Weight4 kg
Beam ConfigurationDual-beam optical design
ComplianceDesigned for integration into GMP/GLP-compliant chromatography workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBE-300V
Column Capacity300 mL
Sample Injection Volume20 mL
Dimensions (W×D×H)330 × 600 × 550 mm
Rotation Speed Range0–1000 rpm
Separation Speed Range700–900 rpm (stepless frequency-controlled)
Flow Rate Range0.1–30 mL/min
Separation Flow Rate0.5–4.0 mL/min
Maximum System Pressure2 MPa
UV Detection Wavelengths214, 254, 280, 340, 365, 405 nm (optional full-spectrum detector available)
Temperature Control Range15–40 °C (±0.5 °C accuracy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP1H05S
Pressure Range0–5.0 MPa
Flow Rate Range1–100 mL/min
Pressure Pulsation≤0.05 MPa
Pressure Accuracy≤±0.20 MPa
Flow Setting Error≤±2% (1–50 mL/min), ≤±1.5% (50–100 mL/min)
Flow Repeatability≤±1.5% (1–50 mL/min), ≤±1% (50–100 mL/min)
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions270 × 400 × 190 mm
Weight17 kg
Wetted MaterialsSapphire ball valves, ceramic plungers, 316L stainless steel or pure titanium pump head & fluid path
Communication InterfaceRS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
ModelTBP1002T
Construction MaterialGrade 2 Pure Titanium (ASTM B348)
Pressure Range0–2.0 MPa
Flow Rate Range0.1–10.0 mL/min
Pressure Pulsation≤ 0.08 MPa
Flow Accuracy±1% of setpoint
Flow Precision (RSD)≤ 1%
Pressure Accuracy±0.05 MPa
Wetted MaterialsCP-Ti (Grade 2), Sapphire Balls, Zirconia Ceramics
Communication InterfaceRS232
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP-1002
Pressure Range0–2.0 MPa
Flow Rate Range0.1–10.0 mL/min
Pressure Pulsation≤ 0.08 MPa
Pressure Accuracy≤ ±0.05 MPa
Flow Setting Error≤ ±1%
Flow Precision (RSD)≤ 1%
Wetted MaterialsSapphire, 316L Stainless Steel, Zirconia Ceramic
InterfaceRS232
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP-2H02K
Flow Range1–200 mL/min
Pressure Range0–2.0 MPa
Pressure Pulsation≤ 0.2 MPa
Pressure Accuracy≤ 0.1 MPa
Flow Setting Error≤ 2% (1–50 mL/min), ≤ 1.5% (50–200 mL/min)
Flow Repeatability≤ 1.5% (1–50 mL/min), ≤ 1% (50–200 mL/min)
Wetted MaterialsPEEK, Sapphire, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 260 × 160 mm
Weight12 kg
Communication InterfaceRS232
Safety FeaturesBuilt-in Overpressure Protection, Flow Calibration System
DisplayLarge LCD Screen
Optional IntegrationPLC-compatible (custom configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
ModelGrad10
Pressure Range0–5.0 MPa
Flow Rate Range0.1–10.0 mL/min
Flow Increment0.1–10.0 mL/min
Gradient Mixing Range0.0–100%
Gradient Accuracy±1%
Pressure Pulsation≤0.08 MPa
Pressure Accuracy≤0.05 MPa
Flow Setting Error≤1%
Flow Precision (RSD)≤1%
Wetted MaterialsSapphire, 316L Stainless Steel, Zirconia Ceramic
Power Supply220 V ±10%, 50/60 Hz
Power Consumption75 W
Dimensions360 × 255 × 160 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelTBP5H02S
Pressure Range0–2.0 MPa
Flow Rate Range1–500 mL/min
Pressure Pulsation≤0.05 MPa
Pressure Accuracy≤0.10 MPa
Flow Setting Error≤3% (1–100 mL/min), ≤1.5% (100–500 mL/min)
Flow Repeatability≤1.5% (1–100 mL/min), ≤1% (100–500 mL/min)
Power Supply220 V ±10%, 50/60 Hz
Power Consumption1 kW
Weight48 kg
Dimensions380 × 560 × 230 mm
Flow Path MaterialsSapphire ball valves, ceramic plungers
pump head options316L stainless steel (L), pure titanium (T), PEEK (K), PTFE (F)
Communication InterfaceRS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTongtian
OriginShanghai, China
ModelS2000
Application LevelLaboratory Grade
Instrument TypeMedium-Low Pressure Preparative LC System
Flow Rate Range1–200 mL/min
Flow Accuracy≤ ±2%
Flow RSD≤ 1%
Max Operating Pressure20 MPa
Wavelength Range±1 nm
Wavelength Repeatability0.2 nm
Baseline Noise1 × 10⁻⁵ AU
Data Acquisition Frequency20 Hz